Safety Technique. Emergency Stop Module With Time Delay BH 5928, BI 5928

Similar documents
Safety Technique. SAFEMASTER Emergency Stop Module With Time Delay BH 5928, BI 5928

Safety Technique. SAFEMASTER Emergency Stop Module LG 5925

Safety Technique. SAFEMASTER Emergency Stop Module With Time Delay LG 5928

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

Power Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250

02/11/2015

Power Electronics. POWERSWITCH Semiconductor Contactor BF 9250, BH 9250

02/11/2015

Installation / Monitoring Technique

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

02/11/2015

Installation- / Monitoring technique

02/11/2015

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/020

ET M3792_a. DC 6, 12, 15, 20, 24 V AC 12, 24, 42, 230 V Voltage range U N

Type CP-S, CP-C & CP-A Switch mode

E-STOP relays, safety gate monitors

Safety relays Protecting the user and the equipment.

E-STOP relays, safety gate monitors

Transformers, Power Supply Units and Socket Outlets

MINI-PS AC/2X15DC/1

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

E-STOP relays, safety gate monitors

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

CP-T range Product group picture

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

CP-E range Benefits and advantages

PSR-SCP- 24DC/ESD/5X1/1X2/300

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Installation- / Monitoring Technique

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Power supply CP-E 24/0.75

Electronic timer CT-SDD.22

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

CP-T range Benefits and advantages

MINI-PS AC/24DC/1.3

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Datasheet - PROTECT-IE-02

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

Three-phase monitoring relay CM-PVE

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Three-phase monitoring relay CM-PFS

Electronic timer CT-TGD.22

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Switching power supplies CP range, Linear power supplies CP-L range. Content

Power supply CP-E 24/2.5

QUINT-PS/ 3AC/24DC/10

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Power supply CP-E 24/20.0

For Immediate Delivery call KMParts.com at (866)

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Thermistor motor protection relays

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

Three-phase monitoring relays

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

QUINT-PS AC/24DC/40

Electronic timer CT-SDS.22

QUINT-PS/ 3AC/24DC/40

Three-phase monitoring relay

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Three-phase monitoring relays CM-PFE and CM-PFE.2

PNOZ X3. } Safety relays. Operating Manual EN-08

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Power supply CP-E 24/2.5

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Circuit diagram. Applications. Function. Function (Continued) Page 23 SNO 4062K /K-A /KM /KM-A

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Electronic timer CT-MFS.21

Power supply CP-T 24/20.0 Primary switch mode power supply

Primary switch mode power supplies Product group picture

Power supply CP-T 24/10.0 Primary switch mode power supply

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Power supply CP-T 24/40.0 Primary switch mode power supply

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

62 Series - Power relays 16 A. Features / /

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

QUINT-PS-24DC/24DC/10

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Power supply CP-D 24/1.3

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Control module CP-A CM

Power supply CP-T 48/20.0 Primary switch mode power supply

Analog signal converters CC-E I/I

Liquid level monitoring relay CM-ENS.2x

38 Series - Relay interface modules A

Power supply CP-T 48/5.0 Primary switch mode power supply

Transcription:

Safety Technique safemaster Emergency Stop Module With Time Delay BH 5928, BI 5928 0226419 BH 5928 BI 5928 Function Diagram According to - Performance Level (PL) e and category 4 to E ISO 13849-1 2008 - SIL Claimed Level (SIL CL) 3 to IEC/E 62061 - Safety Integrity Level (SIL 3) to IEC/E 61508 - Category 4 to E 954-1 Output 3 O or 2 O, 1 C instantaneous contacts and 3 O release delayed contacts Single and 2-channel operation Line fault detection on -button, when -button is connected to - Manual restart with button on - or automatic restart with bridge between - With or without cross fault monitoring in the loop LED indication for supply, channel 1/2 and release delayed contacts Removable terminal strips Wire connection also 2 x 1.5 mm 2 stranded ferruled (isolated), DI 46 228-1/-2/-3/-4 or 2 x 2.5 mm 2 stranded ferruled DI 46 228-1/-2/-3 Width BH 5928 45 mm BI 5928 67.5 mm Approvals and Marking 1) * 1) pending; * see variants Applications Protection of people and machines Emergency stop circuits on machines, stop category 1 can be realised Monitoring of safety gates Indication Canada / USA LED power LEDs, on, when supply connected on, when relay and resp. t and t energized Block Diagram A2 13 23 31 47 57 67 Overvoltage and short circuit prot. Monitoring logic Timer release delay 24V t etz t t 24 32 48 58 68 M7072_c All technical data in this list relate to the state at the moment of edition. We reserve the right for technical improvements and changes at any time. 1 24.10.12 en / 275

Circuit Diagrams 13 23 33 41 57 13 23 37 47 t 13 23 33 41 57 t 13 23 37 47 24 38 48 24 34 42 58 A2 M7277_b 24 38 48 A2 M8076 24 34 42 58 BH 5928.47 BH 5928.91 13 23 31 47 57 67 13 23 33 47 57 67 t 13 23 31 47 57 67 t 13 23 33 47 57 67 24 32 48 58 68 24 34 48 58 68 A2 M7278_c A2 M7279_c 24 32 48 58 68 24 34 48 58 68 BH 5928.92 BH 5928.93 13 23 33 41 57 t 13 23 33 41 57 A2 24 34 42 58 24 34 42 58 A2 M8081_c BI 5928.47/100 2 24.10.12 en / 275

otes To select automatic restart terminals - must be bridged, - must be opened. Open terminals - select manual restart, the button must then be connected to -. Line fault detection on -button The line fault detection is only active when the time delayed relais t and t have released and then (channel A) and (channel B) are switched simultaneously. If the -button is closed before,, is connected to voltage (also when line fault across -button), the output contacts will not close. The unit will not restart before the time delay is finished. A line fault across the -button which occurred after activation of the relay, will be detected with the next activation and the output contacts will not close. If a line fault occurs after the voltage has been connected to,,, the unit will be activated because this line fault is similar to the normal -function. The unit can be operated with single channel and 2-channel operation with cross fault monitoring. For connection please refer to application examples. The gold plated contacts of the BH 5928 mean that this module is also suitable for switching small loads of 1 mva - 7 VA, 1 mw - 7 W in the range 0.1-60 V, 1-300 ma. The contacts also permit the maximum switching current. However since the gold plating will be burnt off at this current level, the device is no longer suitable for switching small loads after this. The terminal permits the operation of the device in IT-systems with insulation monitoring, serves as a reference point for testing the control voltage and is used to connect the loop when cross fault monitoring is selected. Connecting the terminal to the protective ground bridges the internal short-circuit protection of Line. The short-circuit protection of line remains active. ATTETIO - AUTOMATIC START! According to IEC/E 60 204-1 part 9.2.5.4.2 it is not allowed to restart automatically after emergency stop. Therefore the machine control has to disable the automatic start after emergency stop. - must be closed to have timed outputs. By opening the bridge between and the time delay can be interrupted immediately. Without bridge the contacts switch without delay. The time setting has to be sealed by the user after test. Technical Data Input ominal voltage U BH 5928 DC 24 V, AC/DC 24 V BH 5928.92/900, DC 24 V Voltage range DC AC/DC at 10% residual ripple 0.9... 1.1 U 0.95... 1.1 U at 48% residual ripple 0.8... 1.1 U 0.8... 1.1 U ominal consumption AC approx. 6.0 VA DC approx. 3.5 W ominal frequency 50 / 60 Hz Min. Off-time 1 s Control voltage on DC 23 V at U Control current over, 40 ma at U each Min. voltage on, DC 21 V when relay activated Short-circuit protection Internal PTC Overvoltage protection Internal VDR Output Contacts BH 5928.47, BH 5928.91 BH 5928.92 BH 5928.93 Operate delay typ. at U Manual start 40 ms Automatic start 500 ms Release delay typ. at U Disconnecting the supply 40 ms Disconnecting,, and 15 ms Time delay tv (release delayed) Repeat accuracy Contact type ominal output voltage Max switching current Switching of low loads (Contact 5 µ Au) Thermal current I th in 1 contact path 3 O, 1 C contacts instantaneous and 1 O contact release delayed 2 O contacts instantaneous, and 2 O contacts release delayed 2 O, 1 C contacts instantaneous and 3 O contacts release delayed 3 O contacts instantaneous and 3 O contacts release delayed The not delayed O contacts are safety contacts. ATTETIO! The C contacts 31-32 or 41-42 can only be used for monitoring. Auxilary supply must be connected for time delay Time ranges 0.1... 1 s 3.0... 30 s 0.3... 3 s 6.0... 60 s 0.5... 5 s 30... 300 s 1.0... 10 s Other ranges or values on request Fixed values 1 s, 3 s, 5 s, 10 s, 300 s ± 1 % of setting value forcibly guided AC 250 V DC see limit curve for arc-free operation DC see limit curve for arc-free operation 100 mv 1 ma max. 5 A (see quadratic total current limit curve) Switching capacity to AC 15 O contact AC 3 A / 230V IEC/E 60 947-5-1 C contact AC 2 A / 230 V IEC/E 60 947-5-1 to DC 13 O contact 1 A / DC 24 V IEC/E 60 947-5-1 C contact 1 A / DC 24 V IEC/E 60 947-5-1 Electrical life to AC 15 at 2 A, AC 230 V 10 5 switching cycles IEC/E 60 947-5-1 Permissible operating frequency max. 1200 switching cycles / h with manual restart and short release delay time Short circuit strength max. fuse rating 6 A gl IEC/E 60 947-5-1 line circuit breaker C 8 A Mechanical life 10 x 10 6 switching cycles 3 24.10.12 en / 275

Technical Data Technical Data General Data Operating mode Continuous operation Temperature range operation - 15... + 55 C storage - 25... + 85 C altitude < 2.000 m Clearance and creepage distances rated impuls voltage / pollution degree 4 kv / 2 (basis insulation) IEC 60 664-1 EMC Electrostatic discharge 8 kv (air) IEC/E 61 000-4-2 HF irradiation 10 V / m IEC/E 61 000-4-3 Fast transients 2 kv IEC/E 61 000-4-4 Surge voltages between wires for power supply 1 kv IEC/E 61 000-4-5 between wire and ground 2 kv IEC/E 61 000-4-5 HF-line-conducted 10 V IEC/E 61 000-4-6 Interference suppression Limit value class B E 55 011 Degree of protection Housing IP 40 IEC/E 60 529 Terminals IP 20 IEC/E 60 529 Housing Thermoplastic with V0 behaviour according to UL subject 94 Vibration resistance Amplitude 0.35 mm IEC/E 60 068-2-6 frequency 10... 55 Hz Climate resistance 15 / 055 / 04 IEC/E 60 068-1 Terminal designation E 50 005 Wire connection 1 x 4 mm 2 solid or 1 x 2.5 mm 2 stranded ferruled (isolated) or 2 x 1.5 mm 2 stranded ferruled (isolated) DI 46 228-1/-2/-3/-4 or 2 x 2.5 mm 2 stranded ferruled DI 46 228-1/-2/-3 Wire fixing Box terminal with wire protection, removable terminal strips Mounting DI rail IEC/E 60 715 Weight BH 5928 Dimensions Width x height x depth BH 5928 400 g 440 g 45 x 84 x 121 mm 67.5 x 84 x 121 mm Safety Related Data (only instantaneous contacts) Values according to E ISO 13849-1 Category 4 PL e MTTF d 240.5 a (year) 99.0 % d op 365 d/a (days/year) h op 24 h/d (hours/day) t Zyklus 3600 s/zyklus = 1 /h (hour) Values according to IEC/E 62061 / IEC/E 61508 SIL CL 3 IEC/E 62061 SIL 3 IEC/E 61508 HFT 1 99.0 % SFF 99.9 % PFH D 2.05E-10 h -1 T 1 20 a (year) Safety Related Data (only delayed contacts) Values according to E ISO 13849-1 Category 3 PL d MTTF d 219.4 a (year) 99.0 % d op 365 d/a (days/year) h op 24 h/d (hours/day) t Zyklus 3600 s/zyklus = 1 /h (hour) Values according to IEC/E 62061 / IEC/E 61508 SIL CL 2 IEC/E 62061 SIL 2 IEC/E 61508 HFT 1 99.0 % SFF 99.7 % PFH D 2.26E-10 h -1 T 1 20 a (year) *) HFT = Hardware-Failure Tolerance nfo UL-Data The safety functions were not evaluated by UL. Listing is accomplished according to requirements of Standard UL 508, general use applications ominal voltage U BH 5928 DC 24 V; AC/DC 24 V Ambient temperature -15 +55 C Switching capacity Ambient temperature 25 C Ambient temperature 55 C Wire connection nfo At delayed contacts Performance Level (PL) d, category 3 to E ISO 13849 and SIL CL 2 to IEC E 62061 for delays up to max. 30 s. For longer delays Performance Level (PL) c, category 1 and SIL CL 1. The values stated above are valid for the standard type. Safety data for other variants are available on request. The safety relevant data of the complete system has to be determined by the manufacturer of the system. Standard Type Pilot duty B300 5A 250Vac G.P. 5A 24Vdc Pilot duty B300 0,5A 250Vac G.P. 0,5A 24Vdc 60 C / 75 C copper conductors only AWG 20-12 Sol Torque 0.8 m AWG 20 - Str Torque 0.8 m Technical data that is not stated in the UL-Data, can be found in the technical data section. BH 5928.93 DC 24 V 0.5... 5 s Article number 0050369 Output 3 O contacts instantaneous and 3 O contacts release delayed ominal voltage U DC 24 V Time delay tv 0.5... 5 s Width 45 mm *) HFT = Hardware-Failure Tolerance 4 24.10.12 en / 275

Variants BH 5928. / _ /61 BH 5928. /001 BH 5928. /900 Ordering example for variants with UL approval with fix time delay fixed times 1 s, 3 s, 5 s, 10 s, 300s other times on request with adjustable time delay suitable for light curtains and reed contacts switches with adjustable time delay tolerates voltage drop up to 6 V in e-stop circuit B_ 5928. / _ DC 24 V 50/60 Hz 1... 10 s switching voltage U [ VDC ] Characteristics 250 200 150 100 50 M5834_a 0.1... 1 s 0.3... 3 s 0.5... 5 s 1... 10 s 30... 300 s for fixed time end of scale value, other ranges on request ominal frequency ominal voltage Variant, if required Contacts.47 = 3 O contacts, 1 C contact instantaneous and 1 O contact release delayed.91 = 2 O contacts instantaneous and 2 O contacts release delayed (only at BH 5928).92 = 2 O contacts, 1 C contact instantaneous and 3 O contacts release delayed.93 = 3 O contacts instantaneous and 3 O contacts release delayed H width 45 mm I width 67.5 mm 0 1 2 3 4 5 6 switchingcurrent I[A] safe breaking,no continuous arcing, max.1 switching cycle/s Arc limit curve for resistive load (instantaneous contact) Switching voltage U [ V ] 260 220 180 0 100 60 Switching current safe switch-off,no standing arc arc max. 1 switching cycle / s 7 8 20 0 0,2 0,4 0,7 2 4 6 8 10 I [A] M2871 Arc limit curve for resistive load (delayed contact) Quadratic total current limit curve 5 24.10.12 en / 275

Application Examples Off 13 13 23.. 24.. M7074_a M7077_b Single channel emergency stop circuit. This circuit does not have any redundancy in the emergency-stop control circuit Contact reinforcement by external contactors, 2-channel controlled. The output contacts can be reinforced by external contactors with forcibly guided contacts for switching currents > 5 A. Functioning of the external contactors is monitored by looping the C contacts into the closing circuit (terminals - or -) E- stop S1 13 13 M7075_a M7078_a 2-channel emergency stop circuit without cross fault monitoring autostart and interruption of time by S1 2-channel emergency stop circuit with cross fault detection 13 Sliding guard closed S1 S2 13 M7076_d auto start activated o contact (contact position closed) M7079_a Contact reinforcement by external contactors controlled by one contact path. - must be opened. 2-channel safety gate monitoring E. DOLD & SÖHE KG D-781 Furtwangen PO Box 1251 Telephone (+49) 77 23 / 654-0 Telefax (+49) 77 23 / 654-356 e-mail dold-relays@dold.com internet http//www.dold.com 6 24.10.12 en / 275