Contactors & Relays. Contactors & Relays Manual Motor Starters Miniature Circuit Breakers Earth Leakage Isolators. Pg

Similar documents
3RA13, 3RA14 Contactor Assemblies

3/4/2015. Basic relay construction. Shading coil in AC relays. Timothy L. Skvarenina and William E. DeWitt Electrical Power and Controls, 2e

3 - Protection components Circuit-breakers

ELECTRICAL POWER TRANSMISSION TRAINER

Page 4-6. STAR-DELTA STARTERS OPEN FRAME Suitable for three-phase motor control, 16A...690A 440V / 7.5kW...375kW 400V ratings in IEC AC3 duty.

Electrical And Electronics Engg

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Switching Devices Contactors and Contactor Assemblies for Switching Motors

Block Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4

Technical catalogue. Emax Low voltage air circuit-breakers. Hotline:

Industrial Controls. SIRIUS 3R_1* in sizes S00/S0 to S12. Catalog Add-On IC 10 AO 2012 SIRIUS. Answers for industry.

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Page 13-2 Page Page 13-7

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

NIRAPOD 1. High performance circuit breaker mcb and combined mcb with remote controls. LV Distribution Products 2-63A

AC-3 AC-1 230V 400/415V 500V 690V 115V 230V 200V 230V 460V 575V N.O. N.C. Qty. Cat. No. Screw Terminals. Spring Clamp Terminals. 40 C Pkg.

T e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7

Capacitor Switching Contactors

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

DPX TM MCCBs LP* Description Cat. nos. ` / Pack Unit

Maintenance/Connection/Installation Service life C/O cyclesx1000

Enclosed product range

Modeion OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

DPX³ 250 Electronic 4P - ModbusTable LGR EN v1.01.xls

UTE100 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTE100 NT FMU 100A 3P LL LSIS UL MCCB

FINAL - EST Electrical Service Technician Answer Schedule

04 Page. MCCBs characteristics 94. MCCBs & accessories selection guide 96. MCCBs x MCCBs x MCCBs h

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors.

Electrical Protection System Design and Operation

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

PKZ 2 Manual Motor Protectors Technical Data

Item Number No. Poles NO/NC V DC 50/60 Hz. Aux Contactor NO/NC Resistive/ Inductive Amps Price. AF Series

For Immediate Delivery call KMParts.com at (866)

Motor Protection Circuit Breaker Series 8146/5-V27

FIB / FIC. r with Overcurrent Protection (RCBO) Doepke. » effi cient. » reliable. » fl exible. » future-oriented

FINAL - ET 60 - Electrician Theory Examination Marking Schedule

ELECTRICAL INDUSTRIAL INSTALLATIONS

Type: DILEM 10 G(24VDC) Article No.:

Open Type Without Enclosure

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

from 0.5 to 125 A Electrical characteristics Sensitivity type (ma) a AC Electrical auxiliaries Auxiliary and alarm switches (OF-SD)

Power System Protection Manual

technical information


Miniature circuit breakers. Residential current circuit breakers. Busbar systems. Comfort functions/energy control. Residential enclosures

Open Type Without Enclosure

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

Controls Contactors and Contactor Assemblies Special Applications

Installation / Monitoring Technique

Universal Protective Relay Test Set

SHORT FORM. Product Catalog. (800) time-mark.com

MV network design & devices selection EXERCISE BOOK

ELECTRICAL POWER ENGINEERING

J7M-AM/-BM. Motor--protective circuit--breaker system. J7M -BM System IEC 947, EN IEC 947, EN 60947

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Curves TeSys Model U 0 Starter-controllers

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

Modeion MOULDED CASE CIRCUIT BREAKERS BL1000S

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

Protective Relays Digitrip 3000

XT IEC Power Control Miniature Controls

Timers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web: -

Electronic Circuit Breaker ESS1 for System SVS1

Siemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads)

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)

For non-electrical quantities

ELECTRICIAN S THEORY EXAMINATION 20 November 2010 QUESTION AND ANSWER BOOKLET

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Power Electronics. POWERSWITCH Semiconductor Contactor BF 9250, BH 9250

2 or 4 pole changeover contact Plug-in/Faston 187

Modular timers A

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

Circuit protection devices

General Requirements. Technical Specification LVAC Systems

200ADM-P. Current Injection System with Phase Shift A 3.000s 2.000A 50.00Hz 0.0. Features

Motor Control V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87

Protection of Electrical Networks. Christophe Prévé

150 C 30 F B D 8L 152H C 30 F BD 43 8L

Electronic Circuit Breaker ESS1 for System SVS1

Solid-state Contactor Specifications

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

page 2 of 86 Report reference No:

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)

Introduction Characteristics and performance of Compact NSX circuit breakers from 100 to 250 A up to 690 V

Integration between the MV protection and control unit REF542 and the LV protection trip unit PR123: selectivity and earth fault 1SDC007402G0201

# - - Internal * On Line Examination

BUS2000 Busbar Differential Protection System

Relay interface modules A

INDEX. Micro-ohmmeter MH-10 Page 3. MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4

AEG Low Voltage Component

Motor starters. TeSys E. Designed for the essential

CI-tronic Soft start motor controller

Residual Current Operated Circuit-Breakers (RCCBs)

(1,5 modules per pole)

~=E.i!=h. Pre-certification Transformers

3RH1 contactor relays, 4- and 8-pole

Transcription:

Contactors & Relays Contactors & Relays Manual Motor Starters Miniature Circuit Breakers Earth Leakage Isolators Pg 223 230 231 232 232

Contactors & Relays Contactor - GMC Series 3 Pole (240V) AC 1 Rati ng A C3 Rating 380-440V G00010/2/25 AC Operating G00040/2/55 G00070/2/85 G00100/15/20 G00120/30/60 G00140/5/75 G000/90/205 G00220/35 G00250/65 G00280/95 E00010/25 AC/DC Common E00040 Operating E00070/85 E00100/5/15 E00130/45 E00160/75 E00190/205 E00220/35 E00250/65 EA00010< DC Operating EA00030< EA00050< EA00080< EA00120< GMC-9 GMC-12 GMC- GMC-22 GMC-32 GMC-40 GMC-50 GMC-65 GMC-75 GMC-85 GMC-100 GMC-125 GMC-150 GMC-0 GMC-220 GMC-300 GMC-400 GMC-600 GMC-800 GMD-9 GMD-12 GMD- GMD-22 GMD-32 25A 25A 40A 40A 50A 60A 80A 100A 110A 135A 150A 150A 200A 250A 300A 350A 420A 660A 900A 25A 25A 40A 40A 50A 4kW 9A 5.5kW 12A 7.5kW A 11kW 22A 15kW 32A.5kW 40A 22kW 50A 30kW 65A 37kW 75A 45kW 85A 55kW 100A 60kW 120A 75kW 150A 90kW 0A 132kW 250A 160kW 300A 220kW 400A 330kW 630A 440kW 800A 4kW 9A 5.5kW 12A 7.5kW A 11kW 22A 15kW 32A EA00150< GMD-40 60A.5kW 40A EA000< GMD-50 80A 22kW 50A EA00210< GMD-65 100A 30kW 65A EA00240< GMD-75 110A 37kW 75A EA00270< GMD-85 135A 45kW 85A GMC-40 GMC-600 Industrial Electrical Distributor 223 POWER PRODUCTS

Contactors & Relays Mini Contactor - GMC-M Series 3 Pole D00200< D00230< D00295< D00330< AC1 Rating AC3 Rating 500-550V AC Operating DC Operating Screw clamp GMC-6M type GMC-9M GMC-12M GMC-16M Screw clamp GMD-9M GMD-12M 20A 20A 3kW 5A 3.7kW 6A 4kW 7A 5.5kW 9A 3.7kW 6A 4kW 7A Contactor - GMC Series 4 Pole AC 1 Rati ng AC3 Rating 380-440V 20A 20A 25A 32A 50A 60A 4kW 9A 5.5kW 12A 7.5kW A 11kW 22A 15kW 32A.5kW 40A GMC-50/4 80A 22kW 50A GMC-65/4 100A 30kW 65A GMC-75/4 110A 37kW 75A GMC-85/4 GMC-100/4 GMC-125/4 GMC-150/4 GMC-0/4 GMC-220/4 GMC-300/4 GMC-400/4 GMC-600/4 GMC-800/4 135A 150A 155A 200A 230A 260A 350A 420A 660A 900A 45kW 85A 55kW 105A 60kW 120A 75kW 150A 90kW 0A 132kW 250A 160kW 300A 220kW 400A 330kW 630A 440kW 800A AC Operating AC/DC Common Operating GMC-9/4 GMC-12/4 GMC-/4 GMC-22/4 GMC-32/4 GMC-40/4 Industrial Electrical Distributor 224 POWER PRODUCTS

Contactors & Relays Enclosed Motor Starters (380V) Code Model Thermal AC3 Rating Overload 380-440V relay E00274 No push button GMW-12M GTH-22 5.5kW 12A E00281 < Plastic enclosure GMW-M 7.5kW A E00264 < With push button GMW-9B GTH-22/3 4kW 9A E00271 < Steel enclosure GMW-12B 5.5kW 12A E00277 < GMW-B 7.5kW A E00288 < GMW-22B 11kW 22A E00298 < GMW-32B 15kW 32A E00335 < GMW-40B GTH-40/3.5kW 40A E00355 GMW-42B.5kW 40A E00269A < With push button GMW-9MB 4kW 9A E00275/6 Plastic enclosure GMW-12MB 5.5kW 12A E00283 < GMW-MB GTH-22/3 7.5kW A E00294 GMW-22MB 11kW 22A Steel enclosure GMW Without push button steel enclosure GMWB With push button steel enclosure Star Deltas (380V / 3 Phase / 4 Wire) Code Model kw Rating Metered Description IP Rating LS-SD11KW 11kW None LS-1SD11KW Ammeter LS-SD15KW 15kW None LS-1SD15KW Ammeter Star Delta Complete IP65 LS-SDKW.5kW None LS-1SDKW Ammeter LS-SD22KW 22kW None LS-1SD22KW Ammeter * Larger sizes are available on request Contactor Relays (240V) Code Model Composition E00360 < AC operating for GMC GMR-4 4a,3a1b,2a2b,1a3b,4b E00425 < DC operating for GMC GMR-4D 4a,3a1b,2a2b,1a3b,4b Auxiliary Contact Blocks Code Model Composition Application to Q00025 Front mount AU-2 2NO,2NC,1NO+1NC GMC(D)-9-85 Q00040 AU-4 4NO,4NC,2NO+2NC,3NO+1NC, 1NO+3NC Q00085 AU-2M 2NO,2NC,1NO+1NC GMC(D)-6M-16M Q00070 AU-4M 4NO,4NC,2NO+2NC,3NO+1NC, 1NO+3NC Q00010 Side mount AU-1 1NO+1NC GMC(D)-9-85 AU-1M 1NO+1NC GMC(D)-6M-16M Q00055 AU-100 1NO+1NC GMC-100-800 Industrial Electrical Distributor 225 POWER PRODUCTS

Contactors & Relays Spare Coils C ode Model C oil V oltage Application to AC Operating AOM6/16 AC 24,48,110,220,240,380V GMC-9M-16M AOC9/22 AC 24,48,110,220 GMC-9-40 AOC50/85 240,380,415V GMC-50-85 L00070 < AOC100/150 GMC-100-150 AOC0/220 AC/DC 24,48,100-240V GMC-0-220 AOC300-400 AC 300V, AC400V, AC500V GMC-300-400 AOC600/800 GMC-600/800 LIK00010 < DC Operating AOD9/40 DC12V, 24V, 60V, 80V, 100V GMD-9-40 LIL00250 < AOD50/85 125V, 200V, 220V, 250V GMD-50-85 Pneumatic Timer Delay type and Setting range Applicatio n to Q00190 AT-12M/1N AC/DC24-48V ON Delay (0.1 to 30 sec) Q00205 AT-12M/1F AC/DC24-48V OFF Delay (0.1 to 30 sec) Q00220 AT-12M/2N AC100-220V ON Delay (0.1 to 30 sec) GMC(D)-6M-16M Q00235 AT-12M/2F AC100-220V OFF Delay (0.1 to 30 sec) Surge Absorber Unit C ode Model O perating voltage Application to R00190 < AS-12M AC24V-240V, DC12-250V GMC(D)-6M-16M R00100 < Varister AS-11 AC/DC 24-48V R00130 < AS-12 AC/DC 100-125V GMC(D)-9 to 800 R00160 AS-13 AC/DC 200-240V R00175 AS-14 AC380-440V R00010 CR+Varister AS-1 AC24-48V R00025 AS-2 AC100-125V R00040 AS-3 AC200-240V GMD-9 to 85 R00055 AS-4 DC24-48V R00070 AS-5 DC100-125V R00085 AS-6 DC200-220V Industrial Electrical Distributor 226 POWER PRODUCTS

Contactors & Relays Mechanical Interlock Unit AR-12M AR-9 AR-100 AR-0 AR-600 Appl i cati o n to GMC(D)-9M-16M GMC(D)-9-85 GMC-100-150 GMC-0-400 GMC-600,800 Separate Mounting Unit Appl i cati o n to D00115 AZ-12H GTK-12M D00130 AZ-22H GTH-22 D00145 AZ-40H GTH-40 D00160 AZ-85H GTH-85 Capacitor Unit Appl i cati o n to AC-9 GMC(D)-9 to 40 AC-50 GMC(D)-50 to 85 Thermal Overload Relays (Differential Type) H00370 < GTK-12M H00010 < H000780E< H00085 H00220 F00010 < F00100 < F00190 < F00265 < F00355 < GTK-22 GTK-40 GTK-85 GTK-100 GTK-150 GTK-220 GTK-400 GTK-600 No mi nal C urrent [A] 0.14, 0.21, 0.33, 0.52, 0.82, 1.3, 2.1, 3.3, 5, 6.5, 7.5, 8.5, 11, 14 1.6-2.5, 2.5-4 4-6, 6-9, 9-13, 12-, 16-22 -26, 28-40 34-50, 45-65, 63-85 65-100 85-125, 100-150 80, 107, 130, 150, 200 260-400 600-800 Industrial Electrical Distributor 227 Appl icatio n to GMC-6M, 9M, 12M, 16M GMC-9,12,,22 GMC-32,40 GMC-50, 65,75,85 GMC-100,125 GMC-150 GMC-0,220 GMC-300,400 GMC-600,800 POWER PRODUCTS

Contactors & Relays GMP Series - Electronic Motor Protection Relay Tunnel (Definit) Direct (Inverse) J00010/25/40 J00100/15 J00055/70 J00130/45 Screw (Inverse) J00160 GMP60T GMP22-3T(R ) GMP22-3P(R ) GMP40-3P(R ) GMP22-3S GMP40-3S(R ) GMP80-3S Amper e Rati ng Kw (at 440V AC 3) 0.5-6A, 3-30A, 5-60A 0.3-1.5, 1-5, 4.4-22A 0.3-1.5, 1-5, 4.4-22A 4-20, 8-40A 0.3-1.5, 1-5, 4.4-22A 4-20, 8-40A 16-80A up to 22kW 0.12-11kW 0.12-11kW 2.2-15kW 0.12-11kW 2.2-15kW 7.5-37kW DMP Series - Digital Motor Protection Relay M o de l Ampe r e Rati ng Kw (at 4 4 0 V AC 3 ) I00300 < Screw/Unit DMP06-S 0.5-6A 0.12-2.2kW I00360 < (Tunnel type + DMP60-S 5-60A 3-22kW I00380 < Screw terminal) DMP06-SZ 0.5-6A (Ground fault) 0.12-2.2kW DMP60-SZ 5-60A (Ground fault) 3-22kW I00400 < DMP Accessories ZCT Appl i cati o n to LZT-030(Ö30) LZT-050(Ö50) DMP Series Ground fault type LZT-065(Ö65) LZT-080(Ö80) Contactor SMC - 2 Pole M o de l SMC-20P2 AC 1 Rati ng 30A AC 3 Rati ng 2 0 0-2 2 0 V 3 8 0-4 4 0 V 20A 17A Industrial Electrical Distributor 228 POWER PRODUCTS

Contactors & Relays Contactor - GMC Series Reversing C ode Model AC 1 Rating AC 3 Rating 380-440V D00220 AC Operating GMC-9R 25A 4kW 9A D00287 GMC-12R 25A 5.5kW 12A D00285 GMC-R 40A 7.5kW A D00470 GMC-22R 40A 11kW 22A E00004 GMC-32R 50A 15kW 32A E00005 GMC-40R 60A.5kW 40A E00007 GMC-50R 80A 22kW 50A D00495 GMC-65R 100A 30kW 65A D00510 GMC-75R 110A 37kW 75A D00525 GMC-85R 135A 45kW 85A E00015 AC/DC Common GMC-100R 150A 55kW 100A E00017 Operating GMC-125R 150A 60kW 120A E00075 GMC-150R 200A 75kW 150A E00120 GMC-0R 250A 90kW 0A E00150 GMC-220R 300A 132kW 250A E000 GMC-300R 350A 160kW 300A E00195 GMC-400R 420A 220kW 400A GMC-600R 660A 330kW 630A GMC-800R 900A 440kW 800A Mini Contactor - GMC - M Series Reversing 3 Pole C ode Model AC 1 Rating AC 3 Rating 380-440V 500-550V D00200I GMC-6MR 20A 2.2kW 6A 3kW 5A D00230J AC Operating Screw clamp GMC-9MR 4kW 9A 3.7kW 6A D00300L type GMC-12MR 5.5kW 12A 4kW 7A D00330K GMC-16MR 7.5kW 16A 5.5kW 9A DC Operating Screw clamp GMD-6MR 20A 2.2kW 6A 3kW 5A type GMD-9MR 4kW 9A 3.7kW 6A GMD-12MR 5.5kW 12A 4kW 7A GMD-16MR 7.5kW 16A 5.5kW 9A Mini Contactor - GMC - M Series Reversing 4 Pole Code Model AC1 Rating AC3 Rating 380-440V 500-550V GMC-6MR/4 20A 2.2kW 6A 3kW 5A AC Operating Screw clamp GMC-9MR/4 4kW 9A 3.7kW 6A type GMC-12MR/4 5.5kW 12A 4kW 7A GMC-16MR/4 7.5kW 16A 5.5kW 9A DC Operating Screw clamp GMD-6MR/4 20A 2.2kW 6A 3kW 5A type GMD-9MR/4 4kW 9A 3.7kW 6A GMD-12MR/4 5.5kW 12A 4kW 7A GMD-16MR/4 7.5kW 16A 5.5kW 9A Industrial Electrical Distributor 229 POWER PRODUCTS

Manual Motor Starters Manual Motor Starters (MMS) C00010 C00025 C00040 C00055 C00070 C00085 C00100 C00115 C00130 C00145 C00160 B00175 C00190 C00205 C00220 C00235 C00250 C00265 C00280 C00295 C00310 C00325 Frame Type B reaki ng C apaci ty [Icu at 415V ] Adj us tment Range [A] 100kA 32AF High capacity 50kA 63AF Standard 25kA 100AF Standard 50kA 0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.63 0.63-1 1-1.6 1.6-2.5 2.5-4 4.0-6 5.0-8 6.0-10 9.0-13 11.0-17 14.0-22.0-26 22.0-32 28.0-40 34.0-50 45.0-63 55.0-75 70.0-90 80.0-100 Ampere MMS-63S MMS-63S MMS-63S MMS-100S MMS-100S MMS-100S Manual Motor Starter Accessories Q00100 < Q00145 < P00595 < P00655 < Des cri pti o n Auxiliary switch for front mounting Auxiliary switch for front side mounting on the left Any trip alarm switch for side mounting on the left Magnetic trip alarm switch for side mounting on the left Shunt release for side mounting on the right Undervoltage release for side mounting on the right Undervoltage release for side mounting on the right Industrial Electrical Distributor 230 FX LX LA LAM RS RU RUX POWER PRODUCTS 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6 8 10 13 17 22 26 32 40 50 63 75 90 100

Miniature Circuit Breakers Miniature Circuit Breakers (BKN/BKH/BKP) Code Model Pole Ampere Character- Breaking Capacity (Icu) In (A) Frame istics 220V 460V S00010 < 1pole (-) 1,2,3,4 6kA 6,10,16,20,25,32 S00445 < 1pole+N B (3In-5In) 1,2,3,4,6,10,16,20,25,32 S00535 < BKN 2pole C (5In-10In) 6kA 1,2,3,4,6,10,16,20,25,32 S00670 < 3pole D (10In-20In) 6kA 1,2,3,4,6,10,16,20,25,32 S00015 < 3pole+N 1,2,3,4,6,10,16,20,25,32 S00020 < 4pole 63AF 1,2,3,4,6,10,16,20,25,32 S00091-1 < 1pole (-) 1,2,3,4,6,10,16,20,25,32 S00151-1 < 1pole+N B (3In-5In) 1,2,3,4,6,10,16,20,25,32 S000200 < BKN-b 2pole C (5In-10In) 10kA 1,2,3,4,6,10,16,20,25,32 S000600 < 3pole D (10In-20In) 10kA 1,2,3,4,6,10,16,20,25,32 S001000 < 3pole+N 1,2,3,4,6,10,16,20,25,32 S00098 < 4pole 1,2,3,4,6,10,16,20,25,32 S00310 < 1pole B (3In-5In) (-) S00343 < BKH 2pole 125AF C (5In-10In) 10kA 63,80,100,125 S00355 < 3pole D (10In-20In) 10kA 4pole S01020 < BKP 1pole+N 63AF B (3In-5In) 3kA 3kA 1,2,3,4,6,10,16,20,25,32, C (5In-10In) D (10In-20In) BKN-1P-C10 BKN-1P-D32 BKN-2P-C2 BKN-2P-C63 BKN-3P-C32 BKN-B-2P-C32 BKH-1P-C125 BKH-3P-C100 Busbar for MCB Code Model Description Type Auxiliary switch (AX) K00415 Accessories for Bus bar For 1-pole device I Type BK Type U Type K00430 For 2-pole device I Type U Type K00445 For 3-pole device I Type U Type For 4-pole device I Type U Type Industrial Electrical Distributor 231 POWER PRODUCTS

Earth Leakage & Isolator Residual Circuit Breakers (Earth Leakage) Code Model Pole Ampere Protection I (Ma) Icu 220V In (A) Frame S01130 25 S01135 6kA 32 S00970 2P 40 S00985 RKN 63AF 6kA 63 25 6kA 32 4P 40 S01000 6kA 63 15 32KGRa 2P 30AF 1.5kA 20 30 2 4 6 RKP 1P+N32AF 30mA 4.5kA 10 16 S01110 20 S01115 32 Switch Disconnector (Isolator) Code Model Pole In (A) 1P 63 80 100 S00640 2P 63 80 S00655 100 S00790 BKD 3P 63 S00805 80 S00820 100 S00940 125 4P 63 80 100 Industrial Electrical Distributor 232 POWER PRODUCTS