ASPHALT T E C H N O L O G I E S

Similar documents
ROOFING APPLICATION STANDARD (RAS) No. 130 INSTALLATION CRITERIA FOR WOOD SHINGLES AND SHAKES APPLICATION

ROOFING APPLICATION STANDARD (RAS) No. 130

Asphalt Shingle Installation at Roof Edges, Intersections and Valleys

Turada Hardwood Shingles and Shakes Installation instructions

eco-shake INSTALLATION INSTRUCTION

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Hatteras Shingles. CertainTeed Shingle Applicator s Manual. YOUR OBJECTIVE: To learn the correct procedures for installing Hatteras shingles

9Upgrades to Windproof Your Roof

HERITAGE LAMINATED ASPHALT SHINGLES Frederick, MD

PROJECT INSTRUCTIONS Roofing

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

EVALUATION REPORT GAF Materials Corporation 1361 Alps Road, Building 7-3 Wayne, NJ 07470

AIA Specification. Section Slate Shingles PART 1 GENERAL

SG-30 A P P L I C A T I O N I N S T R U C T I O N S. Directions For Application

4. Metal roof jacks at penetrations and attachments

StormMaster Slate General Instructions 1.) GENERAL INSTRUCTIONS 2.) ROOF DECK VENTILATION 3.) ROOF DECK

ESR-1129 Reissued June 1, 2011 This report is subject to renewal in two years.

Improving the Wind Resistance of Roof Systems: Asphalt Shingle Roofs

SECTION PVC THATCH SHINGLE ROOFING SYSTEM PART 1 GENERAL 1.01 SUMMARY

Cambridge English Application Instructions

DIRECTIONS FOR APPLICATION

DIRECTIONS FOR APPLICATION

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

A P P L I C A T I O N I N S T R U C T I O N S

PREMIUM LAMINATED ASPHALT SHINGLES Frederick, MD

SECTION ASPHALT SHINGLES

GlassMaster General Instructions - Ardmore, OK & Hampton, GA <br /> Atlas Roofing

DIRECTIONS FOR APPLICATION

SECTION SLATE SHINGLES. 1.1 SUMMARY A. Section Includes: 1. Slate shingles over underlayment nailed to roof sheathing.

Ekoroof LiteTile Dimensions

Slate Shingle Specifications

1.04 QUALITY ASSURANCE

Installation Instructions

IRONSTONE SLATE & FLASHING SPECIFICATIONS IRONSTONE SLATE

LAMINATED SHINGLES CERTAINTEED SHINGLE APPLICATOR S MANUAL SUPPLEMENT

The proposal includes the replacement of the roof on the entire house (historic massing and later additions) and detached garage.

Fastener Schedule. a, b, c. FASTENER Roof 3-8d (2 1 / ) / ) 3-10d. 3-10d ( ) 3-16d box nails. (3 1 2 toe nails on one side

B. Related Sections: The following Sections contain requirements that relate to this Section:

SECTION WOOD SHINGLES

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: IKO INDUSTRIES LIMITED

C e r t a i n T e e d S h i n g l e A p p l i c a t o r s M a n u a l. and Carriage House STEEP. Slope Application. (over 21/12)

Tuff Rib Panel Installation Specifications

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER:

The better way to build TM. Installation Manual ROOF SIPs

ROOFING City of Grand Rapids Building Safety Division

6 STEP INSTALLATION GUIDE BY DCI

STORMMASTER SHAKE GENERAL INSTRUCTIONS

DECRA Shingle Installation Guidelines

Grand Manor Carriage House and Centennial Slate 16 YOUR OBJECTIVE: To learn the correct method of installing each of these roofing products.

F-WAVE REVIA SYNTHETIC ROOFING SHINGLES

SECTION ASPHALT SHINGLES

2 ½ Corrugated Panel Installation Specifications

RESIDENTIAL ROOFS ADDENDUM NUMBER ONE. August 28, 2017

1 Exam Prep NRCA Roofing Manual: Steep-Slope Roof Systems 2013 Tabs and Highlights

3-Tab Shingle Instructions DURA-SEAL 20 DURA-SEAL 25

ICC-ES Evaluation Report Reissued September 1, 2012 This report is subject to renewal September 1, 2013.

IRONWOOD SHAKE & FLASHING SPECIFICATIONS

PBR Panel Installation Specifications

Installation Instructions

RED DIAMOND SHINGLES Roof Installation Introduction:

OWENS CORNING LAMINATE SHINGLES INSTALLATION INSTRUCTIONS

StormMaster Shake GENERAL INSTRUCTIONS For Spanish Instructions Click Here (Para las Instrucciones Españolas Haga Clic Aquí)

HERITAGE LAMINATED ASPHALT SHINGLES Tuscaloosa, AL

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

b) Symphony comes pre-packaged in color and width blends. There is no need to mix Symphony at the job site. Currently Symphony is available in the

Installation Instructions

METRO PANELS (EXPOSED

Installation Instructions

WOODGATE LAMINATED ASPHALT SHINGLES

Shingle Installation Guidelines

CREEK Technical Services, LLC

SECTION SHEET METAL FLASHING AND TRIM

1 Roof Substrate (Deck) OWENS CORNING BERKSHIRE SHINGLES INSTALLATION INSTRUCTIONS

A201 3 PROPOSED SOUTH ELEVATION SCALE: PROPOSED EAST ELEVATION SCALE: EXISTING EAST ELEVATION EXISTING SOUTH ELEVATION WEST WORKSHOP

Tuff-Rib Install Guide

Capstone Application Instructions

ICC-ES Evaluation Report Issued February 1, 2011 This report is subject to re-examination in one year.

TECHNICAL BULLETIN NEW ICC ES EVALUATION REPORT

BARDOLINE INSTALLATION INSTRUCTIONS

Installation Manual. For Gerard Shingle Products

Installation Instructions

How To Install Asphalt Shingles. Part 1 of 3: Preparing the Roof. Tutorial

Inspire Slate Starter Piece Hip and Ridge. 13 1/2" Height: 13 ½" Width: 12" Squares/ Pallet. Bundles/ Square

REPORT HOLDER: ISAIAH INDUSTRIES, INC. EVALUATION SUBJECT:

Table of Contents. Fasteners... 4 Venting Preparation Installation with Battens - DECRA Tile & DECRA Shake 1

Shapes Siding. Perfection Shingles. Chalk Line

SLATE & SHINGLE INSTALLATION

tamko.com PREMIUM LAMINATED ASPHALT SHINGLES Beauty that Performs.

INSTALLATION DETAILS

Installation Instructions for Standard Lap and Self-Aligning Lap Siding

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: GAF 1 CAMPUS DRIVE PARSIPPANY, NEW JERSEY 07054

ARMORTAB R SUPER TM Shingles Installation Instructions

Timberline and Sovereign Expanded Fastener Placement Area


Ash Brook Golf Course Scotch Plains, New Jersey

Inspire Aledora Slate Application Guidelines

ES Report GAF-Elk Shingle Roof Covering Systems ESR-1475

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.

Transcription:

ASPHALT T E C H N O L O G I E S Evaluation of Active Ventilation Products Inc. Aura-D (AV-24) Ventilator in Accordance With FLORIDA BUILDING CODE PROTOCOL TAS 100(A)-95 TEST PROCEDURE FOR WIND AND WIND DRIVEN RAIN RESISTANCE AND/OR INCREASED WINDSPEED RESISTANCE OF SOFFIT VENTILATION STRIP AND CONTINUOUS OR INTERMITTENT VENTILATION SYSTEM INSTALLED AT THE RIDGE AREA Metro-Dade Notification Number: September 30, 2003

TEST REPORT Dade County Building Code Compliance Office FLORIDA BUILDING CODE PROTOCOL TAS 100(A)-95 TEST PROCEDURE FOR WIND AND WIND DRIVEN RAIN RESISTANCE AND/OR INCREASED WINDSPEED RESISTANCE OF SOFFIT VENTILATION STRIP AND CONTINUOUS OR INTERMITTENT VENTILATION SYSTEM INSTALLED AT THE RIDGE AREA September 30, 2003 Client: Active Ventilation Products Metro-Dade Notification Number: P. O. Box 1521 Test Date: September 24, 2003 85 Clinton Street PRI Job No: AVP-005-02-01 Newburgh, NY 12551-1521 1.1 Description of Discontinuous Roof System: Vent System Product Type: Off Ridge Vent Product Name: Aura-D (AV-24) Dimensions: 15 1/2 high x 30 inch, diameter, with a 30 x 30 inch flange Manufacturer: Active Ventilation Products Prepared Roof Covering Manufacturer: Tamko Roofing Products Product Name: 25 yr Product Dimensions: 12 x 36 Product Type: Three tab strip shingle Felt Underlayment Manufacturer: Tamko Roofing Products Type: ASTM D 226, Type I (No. 15)

Page 3 of 13 Roof Cement/Mastic Manufacturer: Name: Type: Tin Caps: Tamko Roofing Products Heavy Bodied Flashing Cement ASTM D 4586, Type I 29 gauge, 1 7/8 inch, and diameter Primer Manufacturer: Tamko Roofing Products Name: Quick Dry Primer Type: ASTM D 41 Asphalt Coated (Open Mesh) Fabric, 6 in. Wide: Manufacturer: Gardner Other Materials: Caulk/Sealant: Urethane Nails: 1¼ X ⅜ inch Galvanized ring shank, roofing nails Edge Metal: 26 gauge, 2 X 2 inch X 10' Tin Caps: 29 gauge, 1⅝ inch diameter 1.2 Method of Roof Construction: PRI Asphalt Technologies constructed the deck used for this testing as described in the following and in accordance with the requirements of TAS 100-95 and the Florida Building Code: Section 1518. The plywood deck was constructed with 2 inch by 6 inch framing members, spaced 24 inches apart and 15/32-inch thick APA 32/16 span rated sheathing. The sheathing was attached with 8d common nails at 6 inches on center at the edges and 12 inches on center at intermediate supports. See Figure 1 from TAS 100(A)-95. Underlayment The underlayment for this deck, ASTM D 226, Type I (No. 15) felt, was installed in accordance with the minimum requirements set forth in Florida Building Code: Section 1518. The underlayment was applied in two layers by applying a 19 inch wide starter strip at the eave and then applying additional sheets to cover the deck with a 19 inch overlap and minimum 6 inch end laps. The underlayment was fastened to the deck using 1¼ X ⅜ inch Galvanized ring shank, roofing nails

Page 4 of 13 through 29 gauge 1⅝ inch diameter tin caps placed 6 inches on center at the edges and laps and 12 inches on center in the field. Metal Flashing Galvanized, 26 gauge, 2 inch X 2 inch metal drip edge was installed at the perimeter of the deck over the underlayment and then fastening 4 inches on center staggered using with 1¼ X ⅜ inch Galvanized annular ring shank, roofing nails. Any gaps and overlaps of the primed drip edge were sealed with roof cement. All corners were overlapped a minimum of 4 inches. The metal drip edge, after fastening, was primed with asphalt primer. Shingle Application The asphalt shingles were applied using a 7 inch width starter strip and at the eve edge of the test deck. Each starter strip was set in a 8 inches or wider bed of flashing cement and fastened with at least six 1¼ X ⅜ inch Galvanized annular ring shank, roofing nails. The shingles were applied at a 6 inch offset. The shingles were secured to the deck with 1¼ X ⅜ inch Galvanized annular ring shank, roofing nails at a rate of six nails per full shingle. Shingles at eave and rake edges were set in an ⅛ x 8 inch wide bed of roof cement. All shingle cutouts and end pieces were positioned such that no piece exceeded 2 inches distance from the nail fastener. At the rake edges of the deck, the singles were fastened with 1 1/4 inch X 3/8 inch galvanized ring shank nails and cemented. Vent Application Two vent openings 24 inches in diameter were centered between the deck joists and positioned so the vent was 18 inches from the ridge. A ⅜ continuous bead of Urethane sealant was placed between the shingle layer and the underlayment at the cut edge of the 24 inch vent openings. Two ⅜ continuous beads of Urethane sealant was placed beneath the flanges of the Aura off ridge vents 1 and 2 inches from the perimeter. The vents were centered over the 24 inch diameter openings and fastened to the roof deck with 1¼ X ⅜ inch Galvanized annular ring shank, roofing nails placed 1 inch from outer edge of the flange at the four corners and 9 inches on center between the corners. The upper half of the flange was slipped beneath and covered with 3 courses of shingles. The shingles were fastened through the vent flange with 1¼ X ⅜ inch Galvanized annular ring shank, roofing nails. All nail, heads were sealed with roof cement.

Page 5 of 13 1.3 Method of Conditioning The deck with roofing system applied was conditioned for sixteen hours. A recording thermocouple verified that the surface temperature of the shingles reached 135 F for the conditioning period. After vent installation no additional conditioning was required.

Page 6 of 13 1.4 Photographs of Top and Underside of Deck Immediately Prior and Subsequent to Commencement and Termination of Testing. TOP OF DECK IMMEDIATELY BEFORE COMMENCEMENT OF TEST

Page 7 of 13 UNDERSIDE OF DECK IMMEDIATELY BEFORE COMMENCEMENT OF TEST

Page 8 of 13 SOFFIT AREA BEFORE COMMENCEMENT OF TEST

Page 9 of 13 TOP OF DECK IMMEDIATELY AFTER END OF TEST

Page 10 of 13 UNDERSIDE OF DECK IMMEDIATELY AFTER END OF TEST

Page 11 of 13 SOFFIT AREA IMMEDIATELY AFTER END OF TEST 1.5 Absorptive Material Description The absorptive material used for the simulated rainfall calibration was 46 gauge organic felt. 1.6 Wind stream, Simulated Rain Fall, and Flow Meter Calibration Data and Calculations. See Appendix A.

Page 12 of 13 1.7 Detailed Observations. TAS 100(A) DATA AND OBSERVATIONS Active Ventilation Aura-D (AV-24) Ventilator September 24, 2002 Slope: 2" in 12" Air Temp: 86 F Deck Conditioning: Not Required Air Velocity Condition Simulated Rainfall Condition Duration 35 mph 0 mph 70 mph 0 mph 90 mph 8.8 in/hr Off 8.8 in/hr Off 8.8 in/hr 15 min 5 min 15 min 5 min 15 min 0 mph Off 5 min 110 mph 8.8 in/hr 5 min 0 mph Off 5 min Summary Observations: No Vent movement occurred during the test. No water infiltration was measured during the test. A total of 830,720 milliliters of water delivered to the 8 X 6 foot test area during 50 minutes of delivery. Maximum allowable infiltration is 0.05 percent or 415 milliliters.

Page 13 of 13 1.8 Volume of water, which infiltrated the vent openings. 0.0 milliliters = 0.0% of water applied to the test deck. 1.9 Water Infiltration Through Sheathing. None 1.10 Shingles Which Blow Off, Tear or Blow Upward Without Reseating: None 2.0 Result of Testing: PASS (No water applied infiltrated the vent system) The sample submitted for testing complies with all the requirements of Metro-Dade Protocol TAS 100-95, TEST PROCEDURE FOR WIND AND WIND DRIVEN RAIN RESISTANCE OF DISCONTINUOUS ROOF SYSTEMS. Signed: Gary H. Griswold Manager, Testing Services Date: Approved: Date: Charles L. Thomas Professional Engineer