Corona Current-Voltage Characteristics in Wire-Duct Electrostatic Precipitators Theory versus Experiment

Similar documents
Development of Measuring and Computer Interface System for an Industrial Electrostatic Precipitator

Generation of Sub-nanosecond Pulses

OPTICAL EMISSION CHARACTERISTICS OF HELIUM BREAKDOWN AT PARTIAL VACUUM FOR POINT TO PLANE GEOMETRY

Conductance switching in Ag 2 S devices fabricated by sulphurization

Study of DBD electrostatic precipitator under different high voltage waveforms

Partial Discharge Patterns in High Voltage Insulation

Simulation Model of Partial Discharge in Power Equipment

Lecture 36 Measurements of High Voltages (cont) (Refer Slide Time: 00:14)

Experimental study of corona discharge generated by a triode electrode system

High Voltage Engineering

CHAPTER 2 ELECTROMAGNETIC FORCE AND DEFORMATION

MAHALAKSHMI ENGINEERING COLLEGE

Corona Points Discharge Current Measurement on Atmospheric Electric Field

Simplified Approach to Calculate the Back Flashover Voltage of Shielded H.V. Transmission Line Towers

Modeling and analysis along with experimental investigation of the Ground Effect in rod-plate air gaps with or without barrier.

Evaluation and Limitations of Corona Discharge Measurements An Application Point of View

High-Voltage Test Techniques

Experimental and Numerical Study of Corona Discharge Generated by a Wire- Type Dual Electrode Located Between Parallel Grounded Strips

CHAPTER 2 D-Q AXES FLUX MEASUREMENT IN SYNCHRONOUS MACHINES

Physics 4C Chabot College Scott Hildreth

Study of the Effect of Dissipation Points on the Lightning Protection

Measurement Of Partial Discharge (PD) In High Voltage Power Equipment

SCATTERING POLARIMETRY PART 1. Dr. A. Bhattacharya (Slide courtesy Prof. E. Pottier and Prof. L. Ferro-Famil)

9. How is an electric field is measured?

Study and Analysis of Wire Antenna using Integral Equations: A MATLAB Approach

SUPPLEMENTARY INFORMATION

Math 2321 Review for Test 2 Fall 11

Visualization of the Ionization Phenomenon in Porous Materials under Lightning Impulse

Exercise 12. Semiconductors EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Introduction to semiconductors. The diode

Pre-Laboratory Assignment

Summary of Research Activities on Microwave Discharge Phenomena involving Chalmers (Sweden), Institute of Applied Physics (Russia) and CNES (France)

PULSED BREAKDOWN CHARACTERISTICS OF HELIUM IN PARTIAL VACUUM IN KHZ RANGE

Partial Discharge Classification Using Acoustic Signals and Artificial Neural Networks

Experiment 2. Ohm s Law. Become familiar with the use of a digital voltmeter and a digital ammeter to measure DC voltage and current.

Sound source localization accuracy of ambisonic microphone in anechoic conditions

LABORATORY PROJECT NO. 1 ELECTROMAGNETIC PROJECTILE LAUNCHER. 350 scientists and engineers from the United States and 60 other countries attended

Design and construction of double-blumlein HV pulse power supply

EARLY DETECTION OF WEAK POINTS IN MEEC ELECTRICAL POWER NETWORK

Countermeasure for Reducing Micro-pressure Wave Emitted from Railway Tunnel by Installing Hood at the Exit of Tunnel

Picture perfect. Electromagnetic simulations of transformers

Design and Fabrication of Tesla Coil

Calculation of Transients at Different Distances in a Single Phase 220KV Gas insulated Substation

Environmental & Interference Effects of HVDC Converters & Lines

High Voltage Generation

Simulation of Ferroresonance Phenomena in Power Systems

Lab E2: B-field of a Solenoid. In the case that the B-field is uniform and perpendicular to the area, (1) reduces to

CHAPTER 3 SHORT CIRCUIT WITHSTAND CAPABILITY OF POWER TRANSFORMERS

Ferroresonance Experience in UK: Simulations and Measurements

Experiment 3. Ohm s Law. Become familiar with the use of a digital voltmeter and a digital ammeter to measure DC voltage and current.

Analysis of Propagation Paths of Partial Discharge Acoustic Emission Signals

(c) In the process of part (b), must energy be supplied to the electron, or is energy released?

Loss prophet. Predicting stray losses in power transformers and optimization of tank shielding using FEM

Impedance of a Short Dipole Antenna in a Cold Plasma

THE MEASUREMENT OF ATMOSPHERIC ELECTRIC FIELDS USING POLE MOUNTED ELECTROSTATIC FIELDMETERS. John Chubb

AC BARRIER PIN-PLANE CORONA: SIMILARITIES AND DISTINCTIONS TO DC POSITIVE AND NEGATIVE CORONAS AND DIELECTRIC BARRIER DISCHARGE

DC Circuits and Ohm s Law

DIELECTRIC HEATING IN INSULATING MATERIALS AT HIGH DC AND AC VOLTAGES SUPERIMPOSED BY HIGH FREQUENCY HIGH VOLTAGES

UW IEC Group 2011: Continuing Preparations for 300 kv Operation Device Switching

DESIGN OF A 45 CIRCUIT DUCT BANK

Multi-band material loaded Low-SAR antenna for mobile handsets

Influences of a Beam-Pipe Discontinuity on the Signals of a Nearby Beam Position Monitor (BPM)

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

Review Energy Bands Carrier Density & Mobility Carrier Transport Generation and Recombination

K1200 Stripper Foil Mechanism RF Shielding

Design and Construction of a150kv/300a/1µs Blumlein Pulser

Single-turn and multi-turn coil domains in 3D COMSOL. All rights reserved.

Accuracy of Microwave Cavity Perturbation Measurements

Correlation between time and frequency domain polarisation measurements for transformer moisture assessment

DC and AC Circuits. Objective. Theory. 1. Direct Current (DC) R-C Circuit

CONDITION ASSESSMENT OF XLPE MV CABLE JOINTS BY USING AN INSULATION TESTER

Design and Construction of 2.45 GHz Microwave Plasma Source at Atmospheric Pressure

Over-voltage Trigger Device for Marx Generators

Analysis of lightning performance of 132KV transmission line by application of surge arresters

VSD cables in. Working with. industrial & automation applications

Modeling of a Single Pulse Electric Discharge at Sphere/flat Interface by Coupling Contact Multiphysics and Phase Transformations

Influence Of Lightning Strike Location On The Induced Voltage On a Nearby Overhead Line

Internal Model of X2Y Chip Technology

Investigation of ion toroidal rotation induced by Lower Hybrid waves in Alcator C-Mod * using integrated numerical codes

PES & IAS NY Chapter And NY LMAG June 23 rd, 2015

Design and Fabrication of Plasma Array Antenna with Beam Forming

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

GAIN COMPARISON MEASUREMENTS IN SPHERICAL NEAR-FIELD SCANNING

Electromagnetic Field Simulation for ICRF Antenna and Comparison with Experimental Results in LHD

ELECTRICAL CHARACTERIZATION OF ATMOSPHERIC PRESSURE DIELECTRIC BARRIER DISCHARGE IN AIR

3.2 Measurement of high voltages

The Effect of Lightning Parameters on Induced Voltages Caused by Nearby Lightning on Overhead Distribution Conducting Line.

Underwater Spark Sources: Some experimental information.

Groundwave Propagation, Part One

ANALYSIS OF TRANSIENT ACTIONS INFLUENCE IN POWER TRANSFORMER

LABORATORY Experiment 1

Magnetic Field of the Earth

PHYSICS EXPERIMENTS (ELECTRICITY)

Duke Energy Seminar September 3 5, 2008 Concord, NC

Chapter 1: DC circuit basics

Projects in microwave theory 2009

Optimal Voltage Control using Singular Value Decomposition of Fast Decoupled Load Flow Jacobian

A Numerical Study of Depth of Penetration of Eddy Currents

936 IEEE TRANSACTIONS ON POWER DELIVERY, VOL. 22, NO. 2, APRIL /$ IEEE

Winding Function Analysis Technique as an Efficient Method for Electromagnetic Inductance Calculation

A2 WAVES. Waves. 1 The diagram represents a segment of a string along which a transverse wave is travelling.

Transcription:

Ziedan et al. 154 Corona Current-Voltage Characteristics in Wire-Duct Electrostatic Precipitators Theory versus Experiment H. Ziedan 1, J. Tlustý 2, A. Mizuno 3, A. Sayed 1, and A. Ahmed 1 1 Department of Electrical Engineering, Assiut University, Egypt 2 Faculty of Electrical Engineering, Czech Technical University in Prague, Czech Republic 3 Department of Environmental and Life Sciences, Toyohashi University of Technology, Japan Abstract This paper is aimed at investigating how the corona current-voltage characteristics in an electrostatic precipitator (ESP) is influenced by the number of discharge wires, the wires radius and the spacing between wires and the collecting plates. The corona current-voltage characteristics are calculated for each wire. The corona current-voltage characteristics are measured for a laboratory model of a precipitator and calculated by simultaneous solution of Poisson s equation, current density equation and continuity equation for current density. The calculated corona current-voltage characteristics values agreed reasonably with those measured experimentally. Keywords Corona, current-voltage characteristics, wire-duct, electrostatic precipitator I. INTRODUCTION Electrostatic precipitators (ESP) are employed in electric power plants and many industries such as cement production, chemical processing, and domestic air cleaning. The basic processes of electrostatic precipitation are straightforward and well known [1]. A pure theoretical method was presented [2] for calculating the corona current in conductor-to-plane gaps representing unipolar dc transmission line configurations. This method is applied in the present work to investigate corona current-voltage characteristics in wire-duct electrostatic precipitators. An accurate knowledge of the electrostatic field distribution is requested for determining the corona current from discharge wires in precipitators [3, 4]. The onset voltage of corona is a prerequisite for calculating the corona current at a given voltage applied to the discharge wires. The onset voltage of corona from discharge wires in wire-duct precipitators was investigated before [5, 6]. This paper is aimed at investigating how the corona current-voltage characteristic in a wire-duct electrostatic precipitator is influenced by the number N of discharge wires, the wire radius r c and the spacing between the collecting plates 2H, Fig. 1. The corona current-voltage characteristics of an electrostatic precipitator were measured in the laboratory and calculated when the precipitator is stressed negatively. The calculated corona current-voltage characteristics agreed reasonably with those measured experimentally. II. GOVERNING EQUATIONS Poisson s equation relates the electric field intensity E to the space charge density ρ as: E (1) where ε is the permittivity of free space. At the same time, the continuity for the current density or ionic flow vector J is homogeneous: J (2) The ionic flow vector is determined by the electric field as: J k E (3) where k is the mobility of the ions. Defining the scalar potential, which is related to the electric field intensity by: E (4) All attempts in the literature were based on some simplifying assumptions [2, 4]. The most common ones are as follows: (a) The electrode spacing is filled with unipolar space charge like wires polarity. (b) The space charge affects only the magnitude not the direction of the electric field, i.e., E (5) where is a scalar point function of space coordinates depending on charge distribution and ξ is the space-charge-free field. The calculation of the space-charge-free-field within the inter-electrode spacing between the discharge wires and the collecting plates was reported before [6]. (c) The mobility of ions is constant. (d) Thermal diffusion is neglected. (e) The surface field of the discharge wires remains constant at the onset value E, which was calculated before [6]. Corresponding author: Hamdy Ziedan e-mail address: ziedan92@yahoo.com Received; March 2, 21

155 International Journal of Plasma Environmental Science & Technology, Vol.4,.2, SEPTEMBER 21 y 2H 2r c x (a) One wire of ESP L3 L2 L1 Central R1 R2 R3 2H d d (b) Multi-wires of ESP Fig. 1. Configuration of wire-duct ESP. III. METHOD OF ANALYSIS A. Electric field and space charge distributions A method is developed based on mathematical manipulation of equations (1) through (5) which ends up with the following equations for the distributions of the charge density ρ and the scalar along the streamlines of the electric field between the discharge wires and the collecting plates: V 1 1 2 d 2 2 2 (6) e o e e V 2 2 e e d 2 e 2 (7) o where and (= V /V) are the values of and at the surface of discharge wires. V and V are the applied and corona - onset voltages. B. Corona current calculation For each of value of the applied voltage above the onset value V, the corona current is equal to the sum of the currents flowing in all flux-tubes extending between the discharge wires and the collecting plates. The corona current density J en at the surface of the discharge wire where the nth flux-line extending along the axis of the nth flux tube is obtained using eqn. (3), i.e., Jen kenen (3a) where n and E n correspond to the values of and E for the nth flux line. The corona current density J averaged over the wire periphery is calculated as: M J Jen M (8) n1 where M represents the flux tubes emanating from the discharge wire. Multiplying the average value of current density obtained by eqn. (8) by the surface area per unit length of the wire yields the value of the wire corona current. Summation of the corona current per wire for all ESP wires determines the corona current I at the applied voltage value V. IV. FLOW CHART OF THE COMPUTER PROGRAM Fig. 2 shows a flow chart describing the procedure based on MATLAB computer program for calculating the corona current per discharge wire. The corona currents are calculated for applied voltages starting at V s (> V ) and increased in steps ΔV up to a maximum voltage V M. Because of symmetry around both x- and y- axes, it is sufficient if the current distribution is calculated only for one half of ESP, Fig. 1. V. CALCULATED CORONA CURRENT-VOLTAGE CHARACTERISTICS AGAINST PREVIOUS CALCULATIONS The current-voltage characteristic for one-wire ESP (wire radius = 1 mm and wire-to-plate spacing = 11.43 cm) is shown in Fig. 3. It is clear from this figure that the proposed method predicts current values very close to those obtained before using boundary elements [3] and finite elements [4] for the same applied voltage. The proposed method is also applied for calculating the current-voltage characteristics of a three-wire ESP (wire radius =.521 mm, wire-to-wire separation = 2.32 cm, and wire-to-plate spacing = 1.16 cm) is shown in Fig. 4. It is quite satisfactory that the calculated corona current-voltage characteristics agreed well with those obtained before [4, 7]. VI. EXPERIMENTAL CHECK-UP OF CALCULATED CORONA CURRENT-VOLTAGE CHARACTERISTICS A. Experimental Set-up A wire-duct electrostatic precipitator (ESP) was setup in the HV laboratory of Czech Technical University in

Ziedan et al. 156 Start Input data: r c, d, H and N Compute V [6] V = V s ψ = n = 1 Compute ρ m, Eqn. (9) i = 1 ρ e1 = f 1 ρ m Is i = 1 ρ e2 = f 2 ρ m Is i = 2 Compute ρ ei, Eqn. (1) Compute ρ distribution along flux line, Eqn. (6) Compute mean charge density, ρ mi Is n M ψ = ψ + Δψ n = n + 1 Compute J en, Eqn. (3a) Is mi m i = i +1 Calculate average current density, Eqn. (8) Calculate current I, Print I, V Is V>V M V = V+ ΔV Stop Fig. 2. Flow chart for calculating the discharge-wire corona currents at different applied voltages. Prague, Czech Republic to compare the calculated and measured corona current-voltage characteristics for different ESP configurations, Fig. 1. A schematic diagram of the experimental set-up is shown in Fig. 5. The set-up consists of: A regulating transformer, whose input is 22 V, feeds the HV circuit through a contactor switch to connect or disconnect the supply. A HV transformer to step-up the output voltage of the regulating transformer. The output voltage of the HV transformer is rectified through a rectifier circuit being immersed in the transformer oil with a smoothing capacitor bank consisting of two series capacitors; each one is.25 µf, 1 kv. The generated DC voltage is variable in the range -2 kv and is applied to the investigated wire-duct ESP through an 8 kω resistance to limit the current in case a flash happens in ESP. Discharge wires of the ESP itself are steel conductors with radius r c of.26,.935 and 1.975 mm. The wires are hanged vertically between two collecting plates. Each wire is terminated at both ends by two smoothing steel spheres to avoid field intensification. The top ends of the wires are stressed through smooth steel strip. The wire-to-wire spacing d is adjusted to 14.5 cm. Two collecting plates forming the duct of the ESP are made of steel and hanged vertically from a steel support. The dimensions of each plate are 125 cm height and 25 cm length. The plate to plate spacing (2H) is adjusted to 3 cm and 4 cm. All edges of the collecting plates are curved outside to avoid field concentration at edges. A micro-ammeter is used for measuring the corona current from the discharge wire. The meter is shielded to avoid local corona effects. The reading of the micro-

157 International Journal of Plasma Environmental Science & Technology, Vol.4,.2, SEPTEMBER 21.6.5 Present calculation Previous calculation [3] Previous calculation [4] steel supporting frame is about 12 kv. Therefore, the applied voltage can be increased safely up to 11 kv. D. Error currents /m.4.3.2.1 25 3 35 4 45 5 55 6 65 Fig. 3. Corona current-voltage characteristics for one-wire ESP (r c = 1 mm, H = 11.43 /m 1.9.8.7.6.5.4.3.2.1 Present calculation Previous calculation [7] Previous calculation [4] 1 15 2 25 3 35 4 45 5 55 6 Fig. 4. Corona current-voltage characteristics for central wire of three-wires ESP (r c =.521 mm, H = 1.16 cm and d = 2.32 ammeter is recorded by a digital camera which is connected to a computer to record the reading. B. Experimental technique To measure the corona current-voltage characteristics from each discharge wire, a shielded micro-ammeter is connected to the discharge wire and the corona current is recorded as described above with the increase of the applied voltage. C. Experimental check-up results and discussions The corona current-voltage characteristics were measured in the laboratory for each discharge wire of ESP. The corona currents of each discharge wires were measured for different voltage values applied to the discharge wires. Different values of wire radius (r c =.52, 1.87 and 3.95 mm) were used for one- and multidischarge wires (3, 5 and 7 wires) with plate-to-plate spacings (2H) adjusted for 3 and 4 cm. All the measurements are made in HV laboratory of pressure = 11.3 kpa and temperature = 22 C. The maximum voltage applied to the set-up circuit without flash-over between HV feeding terminals and Fig. 6 shows the currents flowing through the set-up when which the discharge wires were disconnected. These currents are in the micro-ampere range which is very small when compared with the milli-ampere range of the ESP corona currents in the presence of discharge wires. This confirms that the set-up connection is free from corona and corona takes place only at the discharge wires of the precipitator. E. Corona current-voltage characteristics Corona current-voltage characteristics were measured and calculated for wire-duct precipitators with different discharge wires (1, 3, 5 and 7) at varying wire radius and plate-to-plate spacing as shown in Figs. 8 through 28. The wire-to-wire spacing was kept constant at 14.5 cm. It is satisfying that the calculated characteristics agreed reasonably -within the experimental scatter- with those measured experimentally. E.1. Effect of wire radius (r c ) The smaller the wire radius, the smaller the onset voltage and the higher is the corona current at the same applied voltage and plate-to-plate spacing for a singlewire precipitator, Figs. 8-1. Also, the smaller the wire radius, the smaller the onset voltage and the higher is the central-wire corona current at the same applied voltage and plate-to-plate spacing for 3-wire precipitators, Figs. 11-13, 5-wire precipitators, Figs. 14-16 and 7-wire precipitators, Figs. 17-19. The decrease of the corona onset voltage with the decrease of the wire radius is attributed to the corresponding field enhancement at the wire surface [5, 6]. The corona current depends on how high the applied voltage above the onset value. This is why the corona current at the same applied voltage increases with the decrease of the onset voltage. E.2. Effect of plate-to-plate spacing (2H) The larger the plate-to-plate spacing, the higher the onset voltage and the smaller is the corona current at the same applied voltage and wire radius for a single-wire precipitator, Figs. 8-1. Also, the larger the plate-to-plate spacing, the higher the onset voltage and the smaller is the central-wire corona current at the same applied voltage and wire radius for 3-wire precipitators, Figs. 11-13, 5-wire precipitators, Figs. 14-16 and 7-wire precipitators, Figs. 17-19. It is quite clear that the corona current decreases with the increase of plate-to-plate spacing, Figs. 8-19, for the same applied voltage and wire radius. This is simply explained by the resulting

Ziedan et al. 158 Contactor switch Regulating Transformer Rectifier circuit 22 V C V 8 KΩ resistance µa Measuring resistance Shielded microammeter µa HV Transformer ESP Fig. 5. Schematic diagram of the experimental set-up. Shielded microammeter Recording camera Support steel frame HV feeding terminals HV transformer Collecting plate edges Curved edges of collecting plate Grounding connection Fig. 6. ESP experimental model in HV lab. decrease of the electric field along the flux lines, where the corona ions are convicting between the discharge wires and the collecting plates. The more of plate-toplate spacing the more is the decrease of the electric field along the flux lines with subsequent decease of the corona current for the same applied voltage in agreement with Fig. 8-19. E.3. Effect of number of discharge wires (N) The larger the number of discharge wires, the more is the shielding effect imposed on the central wire with a subsequent increase of the corona onset voltage and decrease of corona current emitted from the central wire at the same applied voltage and plate to-plate spacing, Figs. 8, 11, 14 and 17 for N = 1, 3, 5 and 7 at r c =.26 mm, Figs. 9, 12, 15 and 18 for N = 1, 3, 5 and 7 at r c =.935 mm and Figs. 1, 13, 16 and 19 for N = 1, 3, 5 and 7 at r c = 1.975 mm. Figs. 2-22 show the corona current-voltage characteristics of central and outer wires of 3-wire precipitator as influenced by the wire radius at the same plate-to-plate spacing. Figs. 23-25 show the corona current-voltage characteristics of central and the two outer wires to the right of the central one of 5-wire precipitator as influenced by the wire radius at the same plate-to-plate spacing. Similarly, Figs. 26-28 show the corona current-voltage characteristics of central and the three outer wires to the right of the central one of 7-wire precipitator as influenced by the wire radius at the same plate-to-plate spacing. It is quite clear that the corona current-voltage characteristics is the lowest for the central wire and moves up for outer wires in the direction toward the end of the collecting plates. This is because the central wire is fully shielded by the other wires with a subsequent decrease of the field at its surface and increase of onset voltage [5, 6]. At the central wire, the

159 International Journal of Plasma Environmental Science & Technology, Vol.4,.2, SEPTEMBER 21 4 3.5 3.25.2 Error Current, µa 2.5 2 1.5 1.15.1.5 2H = 3 cm 2H = 4 cm.5 2 4 6 8 1 12 Fig. 7. Error currents versus applied voltage. 15 2 25 3 35 4 45 Fig. 11. Effect of plate-to-plate spacing on current-voltage characterristics of central wire of three-wire ESP (r c =.26 mm, d = 14.5.18.16.14.16.14.12.12.1.8.6.4 2H = 3 cm 2H = 4 cm.1.8.6.4 2H = 3 cm 2H = 4 cm.2.2 14 16 18 2 22 24 26 28 3 32 Fig. 8. Effect of plate-to-plate spacing on current-voltage characteristics of one-wire ESP (r c =.26 mm). 35 4 45 5 55 6 65 7 75 Fig. 12. Effect of plate-to-plate spacing on current-voltage characterristics of central wire of three-wire ESP (r c =.935 mm, d = 14.5.16.14.12.16.14.12.1.8.6.4 2H = 3 cm 2H = 4 cm.1.8.6.4 2H = 3 cm 2H = 4 cm.2.2 3 35 4 45 5 55 6 Fig. 9. Effect of plate-to-plate spacing on current-voltage characteristics of one-wire ESP (r c =.935 mm). 55 6 65 7 75 8 85 9 95 1 Fig. 13. Effect of plate-to-plate spacing on current-voltage characterristics of central wire of three-wire ESP (r c = 1.975 mm, d = 14.5.16.14.12.18.16.14.1.8.6.4 2H = 3 cm 2H = 4 cm.12.1.8.6.4 2H = 3 cm 2H = 4 cm.2.2 45 5 55 6 65 7 75 8 85 Fig. 1. Effect of plate-to-plate spacing on current-voltage characteristics of one-wire ESP (r c = 1.975 mm). 15 2 25 3 35 4 45 Fig. 14. Effect of plate-to-plate spacing on current-voltage characteristics of central wire of five-wire ESP (r c =.26 mm, d = 14.5

Ziedan et al. 16.18.16.14.12.1.8.6.4.2 2H = 3 cm 2H = 4 cm 35 4 45 5 55 6 65 7 75 Fig. 15. Effect of plate-to-plate spacing on current-voltage characteristics of central wire of five-wire ESP (r c =.935 mm, d = 14.5.2.18.16.14.12.1.8.6.4.2 2H = 3 cm 2H = 4 cm 5 6 7 8 9 1 11 Fig. 19. Effect of plate-to-plate spacing on current-voltage characteristics of central wire of seven-wire ESP (r c = 1.975 mm, d = 14.5.18.16.14.25.2.12.1.8.6.4 2H = 3 cm 2H = 4 cm Current, m A.15.1.5 Outer wire.2 5 6 7 8 9 1 11 Fig. 16. Effect of plate-to-plate spacing on current-voltage characteristics of central wire of five-wire ESP (r c = 1.975 mm, d = 14.5 15 2 25 3 35 4 45 Fig. 2. Current-voltage characteristics of central- and outer- wires of three-wire ESP (r c =.26 mm, d = 14.5 cm, 2H = 4.16.14.16.14.12.12.1.8.6.4.2 15 2 25 3 35 4 Fig. 17. Effect of plate-to-plate spacing on current-voltage characteristics of central wire of seven-wire ESP (r c =.26 mm, d = 14.5.18.16.14.12.1.8.6.4.2 2H = 3 cm 2H = 3 cm 2H = 4 cm 2H = 4 cm 35 4 45 5 55 6 65 7 75 Fig. 18. Effect of plate-to-plate spacing on current-voltage characteristics of central wire of seven-wire ESP (r c =.935 mm, d = 14.5.1.8.6.4.2 35 4 45 5 55 6 65 7 75 Fig. 21. Current-voltage characteristics of central- and outer- wires of three-wire ESP (r c =.935 mm, d = 14.5 cm, 2H =4.18.16.14.12.1.8.6.4.2 Outer wire Outer wire 55 6 65 7 75 8 85 9 95 1 Fig. 22. Current-voltage characteristics of central- and outer- wires of three-wire ESP (r c = 1.975 mm, d = 14.5 cm, 2H =4

161 International Journal of Plasma Environmental Science & Technology, Vol.4,.2, SEPTEMBER 21.18.16.14.12.1.8.6.4.2 15 2 25 3 35 4 45 Fig. 23. Current-voltage characteristics of central-, R1- and outer (R2)-wires of five-wire ESP (r c =.26 mm, d = 14.5 cm, 2H = 4.2.18.16.14.12.1.8.6.4.2 R3 wire 15 2 25 3 35 4 Fig. 26. Current-voltage characteristics of central-, R1-, R2- and outer (R3)-wires of seven-wire ESP (r c =.26 mm, d = 14.5 cm, 2H = 4.18.16.14.12.1.8.6.2.18.16.14.12.1.8.6 R3 wire.4.2 35 4 45 5 55 6 65 7 75 Fig. 24. Current-voltage characteristics of central-, R1- and outer- (R2) wires of five-wire ESP (r c =.935 mm, d = 14.5 cm, 2H = 4.18.16.14.12.1.8.6.4.2 5 6 7 8 9 1 11 Fig. 25. Current-voltage characteristics of central-, R1- and outer- (R2) wires of five-wire ESP (r c = 1.975 mm, d = 14.5 cm, 2H = 4 onset voltage increases with the increase of the number of discharge wires, as the shielding effect becomes more pronounced with the increase of the number of discharge wires, Fig. 2-28. The shielding effect decreases in the direction toward the end of the collecting plates. This is why the current per discharge wire in a multi-wire precipitator increases toward the end of the collecting plates for the same applied voltage and same radius of the discharge wires, Fig. 2-28. VIII. CONCLUSIONS (1) Corona current-voltage characteristics of a.4.2 35 4 45 5 55 6 65 7 75 Fig. 27. Current-voltage characteristics of central-, R1-, R2- and outer- (R3) wires of seven-wire ESP (r c =.935 mm, d = 14.5 cm, 2H = 4.2.18.16.14.12.1.8.6.4.2 R3 wire 5 6 7 8 9 1 11 Fig. 28. Current-voltage characteristics of central-, R1-, R2- and outer- (R3) wires of seven-wire ESP (r c = 1.975 mm, d = 14.5 cm, 2H = 4 laboratory electrostatic precipitator with 1, 3, 5 and 7 discharge wires are calculated and measured for each wire in the laboratory. The calculated values agreed reasonably with those measured experimentally. (2) The smaller the wire radius, the smaller the onset voltage and the higher is the corona current at the same applied voltage and plate-to-plate spacing for single- and multi-discharge wire precipitators. (3) The larger the plate-to-plate spacing, the higher the onset voltage and the smaller is the corona current at the same applied voltage and wire radius for single- and multi-discharge wire precipitators. (4) The larger the number of discharge wires, the more is the shielding effect imposed on the central wire

Ziedan et al. 162 with a subsequent increase of the corona onset voltage and decrease of corona current emitted from the central wire at the same applied voltage and plate to-plate spacing. (5) The current per discharge wire in a multidischarge wire precipitator increases toward the end of the collecting plates for the same applied voltage and same radius of the discharge wires. m m i1 e i1 ei 2 i=3, 4, 5, ei ei 1 mi 1 mi 2 (1) The corresponding value of mi is then calculated before proceeding to the next iteration. The procedure is continued until mi approaches m to the required precision. ACKNOWLEDGMENT The authors would like to thank Prof. Mazen Abdel- Salam of Assiut University, Egypt for his interest in this research work. REFERENCES [1] K. Parker, "Electrical Operation of Electrostatic Precipitators," The Institution of Engineering and Technology, London, United Kingdom, 27. [2] M. P. Sarma and W. Janischewskyj, "D.C. corona on smooth conductors in air. Steady-state analysis of the ionisation layer," Proceedings of the Institution of Electrical Engineers, vol. 116, pp. 161-166, 1969. [3] K. Adamiak, "Simulation of corona in wire-duct electrostatic precipitator by means of the boundary element method," IEEE Transactions on Industry Applications, vol. 3, pp. 381-386, 1994. [4] M. Abdel-Salam and A. Eid, "A finite element method for analysis of current-voltage characteristics of wire-duct precipitators," European Transactions on Electrical Power, vol. 16, pp. 647-66, 26. [5] H. Ziedan, J. Tlustý, A. Syed, A. Mizuno, and A. Ahmed, "Onset Voltage of Corona in Wire-Duct ESP's as Influenced by Precipitator Geometry," in Proc. the 5th International Scientific Symposium, Electroenergetika, Stara Lesna, Slovakia, pp. 23-25, 29. [6] H. Ziedan, A. Sayed, A. Mizuno, and A. Ahmed, "Onset voltage of corona discharge in wire-duct electrostatic precipitators," International Journal of Plasma Environmental Science and Technology, vol. 4, pp. 36-44, 21. [7] G. A. Kallio and D. E. Stock, "Flow visualization inside a wireplate electrostatic precipitator," IEEE Transactions on Industry Applications, vol. 26, pp. 53-514, 199. APPENDIX The procedure for determining the value of e at the surface of the discharge wire where a flux line emanates is explained as follows: (1) The mean charge density m along the flux line is computed along the flux line using the following equation: VV d m o V V d 2 (9) (2) Two values of e1 and e2 are arbitrarily chosen such that e2 > e1 > m. (3) For each value of e, the charge density distribution along the flux line (using eqn. (6)) and the corresponding mean charge density m1, m2 are evaluated. (4) Subsequent values ei are calculated using the following iteration function: