TFZ Programmable FOUNDATION Fieldbus Temperature Transmitter

Similar documents
Isolated, Scaleable 4-20mA with HART Superimposed

TIY Programmable, Isolated Thermocouple Transmitter combines

FDY PC-Programmable Frequency-to-DC Transmitter with Display

THZ DH & WL. Features. Smart HART and WirelessHART Temperature Solutions

Rosemount 148 Temperature Transmitter

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

The Rosemount 848T Wireless Temperature Transmitter

Model 3244MV MultiVariable Temperature Transmitter with Profibus-PA

Two-Wire Programmable Transmitter for:

ECT-DIN. Description. Features. Signal Isolator, Converter, Repeater, Booster and Splitter

Rosemount 148 Temperature Transmitter

ECT-DIN. Features. Signal Isolator, Converter, Repeater, Booster and Splitter. Isolate Signals to stop erratic measurements caused by ground loops.

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Head mounted Temperature Transmitter TF02/TF02-Ex

0 2 1 â Ó. itemp HART TMT182. Technical Information

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

SPT. Description. Features. Site-Programmable, Isolated Temperature Transmitter

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

Model 3244MV. MultiVariable Temperature Transmitter with Profibus PA. Product Data Sheet

Rosemount 148 Temperature Transmitter

Rosemount 248 Temperature Transmitter

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

General Specifications

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

Rosemount 248 Temperature Transmitter

Rosemount 148 Temperature Transmitter

Rosemount 644 Temperature Transmitter

STT 3000 Smart Temperature Transmitter

itemp PA TMT184 Technical information

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

HART Compatible Intelligent 2-wire DIN Rail Transmitters

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

Rosemount 644 Temperature Transmitter

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

0 2 1 â Ó. itemp HART TMT182. Technical Information

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

FC-33, DC SELECTABLE SIGNAL CONDITIONER

SEM210 SEM210X UNIVERSAL TEMPERATURE TRANSMITTER

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

itemp HART DIN rail TMT112

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

Temperature transmitter itemp PCP DIN rail TMT 121

Rosemount 644 Temperature Transmitter

HART Compatible Intelligent 2-wire In-head Transmitters

Multifunction Intelligent 4-wire Isolated Signal Conditioner

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

Temperature Measurement

E+H Model PT TMT184. Temperature head transmitter with PROFIBUS-PA -interface. Supply and digital communication using PROFIBUS-PA

General Specifications

Alphaline Temperature Transmitters

ATT2100/2200 SMART TEMPERATURE TRANSMITTER. Application Areas: ATT 2200 ATT2100

Temperature Transmitters - Head Mounted

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

Temperature Measurement Transmitters for mounting in sensor head

ABB MEASUREMENT & ANALYTICS DATA SHEET. TB82 2-wire conductivity transmitters

Universal Intelligent 2-wire DIN Rail Transmitters

Smart Pressure Transmitter

AI-1500 Smart, Two-Wire Temperature Transmitter with HART Communications

SMART TEMPERATURE TRANSMITTERS. smar

Temperature Transmitters - DIN Rail Mounted

Temperature Measurement

Universal Intelligent 2-wire DIN Rail Transmitters

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Temperature Measurement Transmitters for mounting in sensor head

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

Temperature head transmitter itemp PCP TMT 181

Rosemount 248 Wireless Temperature Transmitter

Mass and Volume Flow Transmitter

Temperature transmitter with local display RIT 261

Temperature head transmitter itemp PCP TMT 181

FieldIT Temperature Transmitter, head mounted TH02/TH02-Ex

Universal Intelligent 2-wire In-head Transmitters

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series

Rosemount 3101, 3102, and 3105

250T Loop-Powered (2-wire) Transmitter 250T. Input. Isolation. 350T DC-Powered (3-wire) Transmitter 350T. Input. Isolation

Temperature Measurement

Fisher 646 Electro Pneumatic Transducer

FieldIT Temperature Transmitter, field mounted TH202/TH202-Ex

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER

Temperature Input Module for Zone 1 Series 9482/32

Field indicator for current loops with HART communication Models DIH50, DIH52

General Specifications

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

SITRANS T measuring instruments for temperature

Temperature head transmitter itemp TC TMT 188

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

Miniature Temptran RTD Transmitters

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Fisher 4200 Series Electronic Position Transmitters

Rosemount 248 Wireless Temperature Transmitter

High-precision process calibrator Model CED7000

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

HART field temperature transmitter Models TIF50, TIF52, TIF62

Rosemount 648 Wireless Temperature Transmitter

Transcription:

June 2013 Description The Programmable FOUNDATION Fieldbus saves wire and installation costs by allowing up to 32 field devices to be networked onto one, low cost FOUNDATION fieldbus H1 segment. The loop-powered (2-wire) offers dozens of input and operation choices. It sets up from the control room over segment wiring using a standard FOUNDATION fieldbus configuration tool to handle 14 RTD types, 9 thermocouple types, as well as direct millivolt and resistance/potentiometer inputs. It converts the input to a FOUNDATION fieldbus H1, two-way digital communication protocol ready for interface with an AMS, DCS or PLC. Easy-to-Order Temperature Assemblies One simple model number is all it takes to order our complete temperature assemblies. They include your choice of general location or hazardous area connection head, RTD or T/C sensors, thermowell and process connection. Figure 1. Universal, programmable input with FOUNDATION fieldbus digital communication protocol. Rugged, Field-Mount Explosion-Proof Enclosure Universal Inputs RTD Thermocouple Millivolts Resistance Potentiometer 2013 Moore Industries-International, Inc. 238-710-00C FOUNDATION Fieldbus H1 Certifications (see Page 8 for details) IECEx ANZEx *All product names are trademarks of their respective companies. Large, Easy-to-Read Display Available in a variety of mounting styles, the installs on a pipe or surface in the field, or on a DIN-rail and relay track in a multi-unit enclosure or cabinet. Features Industry-standard FOUNDATION fieldbus communication. Featuring a bus connection in accordance with IEC 61158-2 and EN 50170, part 4, the can be installed in the same segment with all standard FOUNDATION fieldbus devices. Exceptional measurement accuracy. 20-bit input resolution delivers precise, industry-leading measurements. Easy-to-read, customizable local display. The large display features alphanumeric characters that can be read easily in the field. It can be customized to display the process variable or the output in user-selectable engineering units. Delivers valuable diagnostic information. Standard FOUNDATION fieldbus diagnostics provide indication of unwanted process and transmitter conditions. Remote configuration and diagnostics. The ideal universal plant standard, the offers versatile input and operation choices, and still can be configured and troubleshooted quickly over the segment, from the control room. Long-term stability. Provides up to 5 years between scheduled calibrations. Advanced RFI/EMI protection and ambient temperature compensation. Guard against environmental factors that can quickly degrade measurement accuracy. Page 1

Multidrop Networks Save Wiring Costs The is an H1 Basic Device that conforms to the H1 Standard (IEC61158-2, 31.25 kbits/s) and is implemented as a Group 3 (network configurable), Class 31* device. Acting as a Slave device within a FOUNDATION fieldbus H1 network, up to 32 transmitters connect in a fieldbus (Figure 2) segment. This means you can save time and money by using a single twisted pair, instead of individual loops, to transmit information from multiple devices. Function Blocks Resource Function Block (RB) Contains diagnostic information, hardware and electronics information (memory, manufacturer identification, device type, software tag) and display configuration parameters. Temperature Transducer Block (TB) Contains temperature measurement data, including sensor and terminal temperature. It also includes information about the sensor type, engineering units, linearization, re-ranging, damping, temperature compensation and diagnostics. Analog Input Block (AI) Processes measurements from a sensor and makes them available to other function blocks. The output value from the AI block is displayed in engineering units and contains a status indicating the quality of the measurement. Sets Up from a Hand-Held, DCS or Asset Management System (AMS) Using its Function Blocks, the can be remotely programmed in minutes, or interrogated at any time, over the segment using a standard FOUNDATION fieldbus configuration tool. Examples of programmable parameters include: Identification Information Product designation/ part number, tag, descriptor, installation date, slave address and FOUNDATION fieldbus identification number. Input/Output and Ranges Sensor type, span and zero values, lower/upper output ranges and alarm output status. * Class 31 indicates that the device might publish and/or subscribe data and/or is a client. Figure 2. The transmitter s data and configuration can be viewed, tested and changed from the control room using a HART hand-held configurator, DCS or AMS equipped with a standard FOUNDATION fieldbus configuration tool. Up to 32 THZ Transmitters per Segment FOUNDATION Fieldbus Host H1 Card T Auto Terminator MooreHawke Fieldbus Device Coupler Spur Length 120m (393ft) FOUNDATION FIELDBUS H1 Network 1900m (6233ft) Segment Length Terminator T MooreHawke Fieldbus Power Supply Fieldbus Device Couplers and Power Supplies MooreHawke, a division of Moore Industries, provides a complete line of FOUNDATION Fieldbus and PROFIBUS PA Device Couplers and Power Supplies. For more information, go to: www.miinet.com/moorehawke Page 2

Set Damping Time Eliminate imprecise readings caused by noise and other insignificant process fluctuations by setting a damping time between 1-30 seconds. View Real-Time Process Values View the existing process value (in the appropriate engineering unit), and lower and upper range values as a percentage of output span. Non-Volatile Memory If power to the transmitter is lost, the unit resumes normal operation with the parameters you ve configured upon reapplication of power. Total Sensor Diagnostics transmitters perform continuous sensor diagnostics. This patented Moore Industries feature can save you from costly lost production time and hours of troubleshooting. If the sensor breaks or otherwise stops sending a signal during operation, the transmitter instantly displays the type and location of the error on its display. Precise Linearization and RJC The uses an advanced linearization method to minimize conformance error. Its Reference (Cold) Junction Compensation techniques produce stable readings even in fluctuating ambient temperature conditions. For non-linear inputs, create custom linearization curves using the fieldbus configuration tool. Figure 3. The can be set to measure the segment most critical to the process. 100 98 C 27 20 1 0 Lower (Zero) Range IDEAL RTD CURVE (USED BY DEFAULT) CAPTURED 20 C-27 C UPPER TRIM POINT #2 LOWER TRIM POINT #1 ACTUAL SENSOR CURVE Full (High) Range Trims to Respond to Specific Sensor Curve Segments Most transmitters zero and span values can be calibrated to measure a specific range within a sensor s overall curve capability. However, for even greater measurement accuracy, our transmitter s trim capabilities go much further. The can be trimmed with two data points within the selected zero and span measurement range. This advantage allows a complete process range to be monitored, while placing measurement emphasis on a specific segment of the range most critical to the process. In Figure 3, the actual sensor curve is used in place of the ideal RTD curve between 20 C and 27 C. This provides incredible precision over a limited portion of the span, while measuring the remainder of the span with the s usual outstanding accuracy. Page 3

Specifications Performance Input Accuracy: Refer to Table 4 Overall Accuracy: The overall accuracy of the unit is the input accuracy. It includes the combined effects of linearity, hysteresis, repeatability and adjustment resolution. It does not include ambient temperature effect. For T/C input, add the RJC error. Reference Junction Compensation: ±0.45 C (±0.81 F) Stability: Refer to Table 1 Isolation: 500Vrms between input, output and case continuous, and will withstand a 500Vac dielectric strength test for one minute (with no breakdown) Step Response Time: 500msec, maximum, 256msec typical from the time an input is applied until the time the corresponding floating point processed variable is available to be read by other FOUNDATION Fieldbus devices Over-voltage Protection: Input, ±5Vdc peak, maximum Digital Input Filter: 50/60Hz (user-selectable) Performance (Continued) Display Power Supply Requirement: 9-32Vdc, 10.5mA typical 12.07mA maximum under normal operation; 18mA maximum under fault conditions Supply Range: 9-32V, Foundation Fieldbus Approved Load Effect: N/A T/C Input Impedance: 40Mohms, nominal Excitation Current: RTD and Ohms, 250 microamps, ±10% RTD Lead Wire Resistance Maximum: RTD resistance + 2X lead wire resistance <4000 ohms; Recommended lead wire resistance for three wire connections: <35 ohms/wire; 10 ohm copper sensor <5 ohms Sensor Lead Resistance Effect: 1.0 ohm in reading/ ohm of lead resistance for 2-wire sensors; 1.0 ohm in reading/ohm of lead of unbalanced resistance for 3-wire sensors; no effect on 4-wire sensors Resolution: Input, 20-bit Type: Top Row, 10mm (0.4 in) high black digits on a reflective background; Bottom Row, 6mm (0.225 in) high digits on a reflective background; Display (Continued) Ambient Temperature Weight Two-digit FOUNDATION Fieldbus address indicator Format: Two rows of five alphanumeric characters Decimal Points: Automatically adjusted decimal point with a user selectable maximum up to four places Range: -99999 to 99999 Minimum Display Span: 1.00 Operating and Storage Range: -40 C to +85 C (-40 F to +185 F) Relative Humidity: 0-95%, non-condensing Ambient Temperature Effect: Refer to Table 2 Effect on Reference Junction Compensation: ±0.005 C of input span/ C change of ambient temperature RFI/EMI Immunity: 20V/m@80-1000MHz, 1kHz AM when tested according to IEC 1000-4- 3-1995 with 0.5% of span or less Startup Time: Performance falls within specification 8 seconds after power is applied Noise Rejection: Common mode, 100dB@50/60Hz; Normal Mode: Refer to Table 3 210g (7.4 oz) Table 1. Long-Term Stability Table 2. Ambient Temperature Effects Stability (% of Max. Span) T/C, mv RTD, Ohm, Pot Table 3. Normal Mode Rejection Ratio Sensor Type Resistance 1-4kohms 0.25-1kohms 0.125-0.25kohms Input to FOUNDATION Fieldbus H1 1 yr 0.008 0.047 3 yrs 0.014 0.081 T/C: J, K, N, C, E T/C: T, R, S, B Pt RTD: 100, 200, 300 ohms Pt RTD: 400, 500, 1000 ohms Ni: 120 ohms Cu: 9.03 ohms mv 250-1000 62.5-250 31.25-62.5 5 yrs 0.019 0.104 Max. p-p Voltage Injection for 70dB at 50/60Hz 150mV 80mV 250mV 1V 500mV 100mV 1V 250mV 100mV Sensor Type RTD T/C Millivolt Ohm Digital Accuracy per 1 C (1.8 F) Change in Ambient 0.003 C 0.003 C + 0.005% of reading 0.005mV + 0.005% of reading 0.002 ohms + 0.005% of reading Page 4 Specifications and information subject to change without notice.

Table 4. Input and Accuracy Input Type α Ohms 0.003850 100 200 300 Platinum 400 500 1000 100 Conformance Range -200 to 850 C -328 to 1562 F Minimum Span 10 C (18 F) Input Accuracy ±0.1 C (±0.18 F) Maximum Range -240 to 960 C -400 to 1760 F Sensor-to- Transmitter Matching Up to ±0.014 C (±0.025 F) system accuracy*. *High-accuracy measurements are achieved by using a 4-wire, 1000 ohm platinum RTD with a span of 100 F (50 F minimum) calibrated in our 200 0.003902 400-100 to 650 C -148 to 1202 F -150 to 720 C -238 to 1328 F 500 1000 Nickel Copper 0.003916 0.00672 0.00427 100 120 9.035-200 to 510 C -328 to 950 F -80 to 320 C -112 to 608 F -50 to 250 C -58 to 482 F 100 C ±0.85 C (±1.53 F) -240 to 580 C -400 to 1076 F -100 to 360 C -148 to 680 F -65 to 280 C -85 to 536 F Ohms Direct Resistance Potentiometer 0-4000 ohms 125, 250, 500, 1k, 2k, 4k ohms 0-4000 ohms 0-100% 10 ohms 10% ±0.4 ohms ±0.1% 0-4095 ohms 0-100% J -180 to 760 C -292 to 1400 F 35 C 63 F ±0.25 C (±0.45 F) -210 to 770 C -346 to 1418 F K -150 to 1370 C -238 to 2498 F 40 C 72 F ±0.3 C (±0.54 F) -270 to 1390 C -454 to 2534 F E -170 to 1000 C -274 to 1832 F 35 C 63 F ±0.2 C (±0.36 F) -270 to 1013 C -454 to 1855.4 F T -170 to 400 C -274 to 752 F 35 C 63 F ±0.25 C (±0.45 F) -270 to 407 C -454 to 764.6 F R 0 to 1760 C 32 to 3200 F 50 C 90 F ±0.55 C (±0.99 F) -50 to 1786 C -58 to 3246.8 F S 0 to 1760 C 32 to 3200 F 50 C 90 F ±0.55 C (±0.99 F) -50 to 1786 C -58 to 3246.8 F B 400 to 1820 C 752 to 3308 F 75 C 135 F ±0.75 C (±1.35 F) 200 to 1836 C 392 to 3336.8 F N -130 to 1300 C -202 to 2372 F 45 C 81 F ±0.4 C (±0.72 F) -270 to 1316 C -454 to 2400.8 F C 0 to 2300 C 32 to 4172 F 100 C 180 F ±0.8 C (±1.44 F) 0 to 2338 C 32 to 4240.4 F Millivolts DC -50 to 1000mV 4mV 15 microvolts -50 to 1000mV Page 5

Ordering Information Unit Programmable FOUNDATION Fieldbus Transmitter Input Output Power Options Housing TPRG Programs to accept RTD, T/C, ohm and mv inputs H1 FOUNDATION Fieldbus H1 9-32DC for General Location and Non-Incendive Applications 9-30DC for Intrinsically-Safe Applications 9-24DC for FISCO Applications (10.5mA typical; 12.07mA maximum under normal operation; 18mA maximum under fault condition) -VTD Factory calibration with NIST traceable test report -VTB* Factory calibration using Sensor-to- Transmitter Trimming with NIST traceable test report * The -VTB option applies to units ordered with sensors and complete temperature assemblies only HP Hockey puck housing and spring clips DN Snap-in mounting for HP case on TS-32 DIN-rail FL Mounting flanges on HP for relay track or screw mounting FLD Mounting flanges on HP for 3½ relay track mounting BH2NG Explosion-Proof enclosure with two 1/2-inch NPT entry ports and a glass cover BH2TG Explosion-Proof enclosure with two 3/4-inch NPT entry ports and a glass cover BH2MG Explosion-Proof enclosure with two M20 x 1.5 NPT entry ports and a glass cover BH3NG Explosion-Proof enclosure with three 1/2-inch NPT entry ports BH3TG Explosion-Proof enclosure with two 3/4-inch side-entry NPT ports, one 1/2 bottom port, and a glass cover BH3MG Explosion-Proof enclosure with two, M20 x 1.5 side-entry ports, one 1/2 bottom-entry port, and a glass cover D2LC 2-Hub, low base, clear cover, IP66/NEMA 4X enclosure SB2NG 2-Hub, Explosion-Proof enclosure with two, ½-inch NPT entry ports and a glass cover SB2MG 2-Hub, Explosion-Proof enclosure with two, M20 x 1.5 entry ports and a glass cover A suffix with BH or SB indicates ANZEx/TestSafe (Ex d) Flame-Proof approvals; 2 pipe-mount kit is included (i.e., BH2MGA or SB2MGA) E suffix with BH or SB indicates ATEX Flame-Proof enclosures; 2 pipe-mount kit is included (i.e., BH2MGE, SB2NGE) P suffix indicates enclosure is equipped with 2 pipe-mount hardware kit (i.e., BH2NGP) To order, specify: Unit / Input / Output / Power / Options [Housing] Model number example: / TPRG / H1 / 9-32DC [BH2NG] Figure 4. Sensor/input connections + Thermocouple and Millivolt Input 2-Wire RTD or Decade Resistance Box 3-Wire RTD or Decade Resistance Box 4-Wire RTD or Decade Resistance Box Potentiometer Input Page 6

Figure 5. Dimensions for in HP (hockey-puck) housing with flanges (FL) 77mm (3.00 in) 66mm (2.58 in) 18mm (0.70 in) 63mm (2.45 in) 83mm (3.25 in) 61mm (2.40 in) 44mm (1.70 in) 64mm (2.53 in) FRONT VIEW SIDE VIEW Figure 6. Dimensions for the in BH field-mount enclosure SIDE VIEW 102mm (4.00 in) GND 119mm (4.70 in) 57mm (2.25 in) 25mm (1.00 in) 1/2 NPT 77mm (3.00 in) TOP VIEW 10mm (0.38 in) 64mm (2.53 in) 102mm (4.00 in) 84mm (3.31 in) 68mm (2.69 in) 63mm (2.45 in) 124mm (4.90 in) 25mm (1.00 in) Page 7

Figure 7. Dimensions for in D-BOX field-mount enclosure 130mm (5.12 in) 116mm (4.56 in) Cover Body Bezel Conduit Fitting 118mm (4.65 in) 112mm (4.40 in) 83mm (3.25 in) 64mm (2.50 in) Interior Diameter 81mm (3.20 in) C L Instrument Tag 84mm (3.30 in) 27mm (1.05 in) Certifications C US IECEx Factory Mutual (US/Canada) Intrinsically-Safe & Non-Incendive Class I, Divisions 1 & 2, Groups A, B, C & D Class I, Zone 0, AEx ia IIC T4 ATEX Directive 94/9/EC: Intrinsically-Safe & Type n II 1G Ex ia IIC, T4@85 C max II 3G Ex na IIC, T4@85 C max IECEx: Intrisically-Safe & Type n Ex ia IIC T4 Ga Ex na nl IIC T4 GA CE Conformant EMC Directive 2004/108/EC EN 61326 ANZEx -HP in BH/SB2 Housing Factory Mutual: Explosion-Proof & Dust-Ignition Proof Class I, Division 1, Groups A*, B, C & D Class II & III, Division 1, Groups E, F & G Environmental Protection: Type 4X &IP66 T6 @60 C Maximum Operating Ambient * For Group A applications, seal all conduits within 18 Canadian Standards Association Explosion-Proof Class I, Division 1, Groups A*, B, C & D Class II & III, Division 1, Groups E, F & G Environmental Protection: Type 4X &IP66 T6 @60 C Maximum Operating Ambient * For Group A applications, seal all conduits within 18 ATEX Directive 94/9/EC: Explosion/Flame-Proof II 2 G Ex d IIC T6 (Tamb 60 C) II 2 D Ex td A21 IP66 T85 C ANZEx (TestSafe): Explosion/Flame-Proof Ex d IIC T6 (Tamb 60 C) United States info@miinet.com Tel: (818) 894-7111 FAX: (818) 891-2816 Australia sales@mooreind.com.au Tel: (02) 8536-7200 FAX: (02) 9525-7296 Belgium info@mooreind.be Tel: 03/448.10.18 FAX: 03/440.17.97 The Netherlands sales@mooreind.nl Tel: (0)344-617971 FAX: (0)344-615920 China sales@mooreind.sh.cn Tel: 86-21-62491499 FAX: 86-21-62490635 United Kingdom sales@mooreind.com Tel: 01293 514488 FAX: 01293 536852 Page 8