Safety Light Curtain Orion1 Extended

Similar documents
series. Safety sensor for Palletisers. Features. For Palletiser. 3 Different types available. Active - Passive system and Plug and play

Emergency stops and safety stops

Safety detection solutions Preventa

SAFETY LIGHT CURTAINS

SAFETY LIGHT CURTAINS

Multiple Light Beam Safety Device. New MLD

MiniSafe Light Curtains

Options M-12 quick-disconnect connector. MTS (Machine Test Signal) Muting through RM-3 module Explosion-proof versions available

APPLICATIONS. Automotive

PD140FNT60QMU-02C. Through Beam. Main features. Description

General-Purpose Photoelectric Sensor

F3SJ-B. Safety Light Curtain. Basic Type with a combination of performance and functionality. Ordering Information. Main Units Safety Light Curtain

F3SN-A & F3SH-A. Safety Light Curtain & Multiple-beam Safety Sensor

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission

Standard Micro 400 safety light curtains are factory assembled in IP69K polycarbonate enclosures with Delrin end caps.

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation

SMARTSCAN 8000 SERIES LIGHT CURTAIN Series Safety Light Curtain Installation Sheet (CD159/030210)

Original operating instructions Fail-safe inductive sensor GM705S

W 23-2: Focussing on what is essential and economic

Acceleration sensors With relay output for limit monitoring Analog / CANopen

Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global

Emergency stops and safety stops

SF4-AH SERIES. Small Light Curtain Type 4. Compact size of mm in Type 4 light curtain ORDER GUIDE.

JANUS MI / MM / ML / MT TRX JANUS MI TRX L / J TRX L

Emergency Stops. Shut down all machine functions! Protect machine during breakdown! Meet emergency stop regulations!

8000 Series Safety Light Curtain Installation Sheet ( CD159/ )

Distance-setting Photoelectric Sensor

RM-3 Mute Module Installation and Operating Manual

DATAVS2 series.

Incremental encoders Blind or through hollow shaft ø12 mm pulses per revolution

panasonic-electric-works.net/sunx Type 2 safety solution International regulations for safety measures at reasonable cost

A Super trainer with advanced hardware and software features only found in very expensive equipment.

ORIGINAL INSTRUCTIONS

Pressure transmitter for mobile hydraulic applications With output signals CANopen and J1939

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

D-LAS Series D-LAS2-LC-... Design. D-LAS Series Laser Digital Light Barriers. Product name: Transmitter: D-LAS2-LC-T.

DATAVS2 series.

Distance-setting Photoelectric Sensor

Distance Sensors BOD 26K.... with optional Master-Slave-Mode

Product Information. RCN 2000 RCN 5000 RCN 8000 Absolute Angle Encoders for Safety-Related Applications

Process/Mini. English IMPORTANT NOTE. Installation and Operation Manual. General Purpose Light Curtain with 30 mm resolution

Safety Light Curtains

Grundfos Direct Sensor

INSPECTION SENSORS SVS2 SERIES VISION SENSORS HIGHLIGHTS APPLICATIONS

Example: ZX-BGS-DS300P-2M ZX Series - Diffuse Background Suppression Type - Distance Settable, 300mm Sensing Distance, PNP - 2m Cable

PHOTOELECTRIC S300 MAXI SENSORS APPLICATIONS.

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

Incremental Encoder Model: FOI58

Original operating instructions Fail-safe inductive sensor GG507S

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

No-wear isolation of potentials in terminal block design

UNIVERSAL MINIATURE SENSORS

1000 SERIES INSTALLATION SUPPLEMENT Rev. 7/1/10

MLV40 Series Miniature Sensors

Specifications. Safety Ratings. Standards. Safety Classification

Online data sheet ISD ISD400 OPTICAL DATA TRANSMISSION

1000 SERIES INSTALLATION SUPPLEMENT Rev

Incremental encoders With blind or through hollow shaft pulses per revolution programmable

Online data sheet AFS60A-BJPA AFS/AFM60 SSI ABSOLUTE ENCODERS

Safety Light Curtain / Multi-beam Safety Sensor. Sense the Difference, Make a Difference!

Temposonics. Magnetostrictive Linear Position Sensors. EP2 Analog Data Sheet

Temposonics. E-Series Model ER. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. Analog and Start/Stop Outputs.

INTRODUCTION 提夫自控技术 ( 上海 ) 有限公司 LAS laser sensors cover measurement ranges from 1 to mm. The integrated micro-controller delivers an accur

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

E3Z-LS. Distance-settable Photoelectric Sensor. Ordering Information. Sensors. Accessories (Order Separately)

FF-SB Series. Type 4 self-contained light curtain For the protection of operators in Industry FF-SB

Online data sheet UE43-3AR3D2 UE43-3AR SAFETY RELAYS

Assembly Instructions

Integrated servo motor

Product Information ECI 1319S EQI 1331S. Absolute Rotary Encoders without Integral Bearing and with DRIVE-CLiQ Interface.

PHOTOELECTRIC SAFETY BARRIER ADMIRAL INSTALLATION USE AND MAINTENANCE INTRODUCTION... 2 OPERATION... 3 INSTALLATION... 4

IBV 100/EXE 100 Interpolation and Digitizing Electronics

I am the new generation. Temposonics. Magnetostrictive Linear Position Sensors. R-Series V RP Profinet RT & IRT Data Sheet

Parallel Beam Linear Sensor

Incremental encoders With blind or through hollow shaft pulses per revolution programmable

MSI-MD-FB Muting Controller

A-LAS Series A-LAS-F12. Design. A-LAS Series Analog Laser Light Barriers. Product name: Accessories: (cf. page 5) A-LAS-F12-(aperture)*-(fork size)**

Online data sheet. DBS60E-TECJD1024 DBS60 Core INCREMENTAL ENCODERS

CCD-array with RTSC. Laserdiode. Multi-lens optics. Filter

Temperature Input Module for Zone 1 Series 9482/32

Absolute encoders - SSI

Online data sheet UE48-3OS2D2 UE48-3OS SAFETY RELAYS

Class II. Sensing method Appearance Connection Sensing distance Output function Model method NPN output PNP output mm.

E L E V A T O R S ELEVATORS Impaginato_2009_UK.indd :34:14

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T Analog Data Sheet

Inductive Linear Position Sensor LI800P0-Q25LM0-LIU5X3-H1151

SMARTSCAN INFORMATION

UNIVERSAL MINIATURE SENSORS

E3S-CR62/67. Ideal for detecting transparent glass and plastic containers. Transparent bottle sensor. Features

NAT Applications. Features

Electronic Circuit Breaker ESS1 for System SVS1

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T SSI Data Sheet

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

Online data sheet UE48-2OS2D2 UE48-2OS SAFETY RELAYS

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

SALES SERVICE +358 (0)

Valve Island with Electronic I/O

Transcription:

Safety Light Curtain Orion1 Extended pprovals: pplication: For finger and hand detection When the light guard should be close to the hazardous zone When muting or blanking are necessary When several devices should be connected in series (cascading) When space is an issue (no dead zone) Features: Finger and hand detection 7 m and 20 m operating distances (finger and hand detection) Compact dimensions Local reset and EDM Muting and lanking Cascading No dead zone The Orion1 Extended light curtains are used for finger or hand detection, usually quite close to the dangerous machine, when advanced functions like muting or cascading are necessary. Easy to use Muting sensors are connected directly to the light curtain, with no need for a remote extra muting module. No dead zone: the resolution is guaranteed along the whole length of the light curtain with no need for extra mechanical guard. Cascading with the standard units, no separate slave or master units. Faster installation lignment help and a wide angle within the limits of a Type 4 device facilitate alignment. M connectors speed up cabling. Less downtime Since the alignment level is displayed on the unit, the alignment can be improved before an unwanted stop occurs. Coding protects against mutual interferences. Extensive error indication reduces troubleshooting time. Protective tubes and lens shields protect the devices in harsh environments. Muting: the machine stops when a person goes through but not when the cases go through. Floating blanking: a hand through the detection zone will stop the machine and the moving wire will not.

Technical data Functional Safety Data EN ISO 13849-1:2008 PL e, Cat 4 EN 6108-1..4:2010 SIL3; PFH d = 2.64 0-9 ; HFT = 1; Mission time = 20 years EN 62061:200/1:2013 SIL CL 3 Power supply +24 VDC ± 20 % Power consumption Transmitter 3 W max Receiver W max (without load) Outputs 2 PNP Short-circuit protection: 1.4 max Output current: 0. max / output Output voltage ON: Vdd -1 V min Output voltage OFF: 0.2 V max Capacitive load: 2.2 μf at +24 VDC max Current for external lamp 20 m min; 300 m max Connectors with specific cables Transmitter with M-C02PT2T: M- pole male connector Receiver with M-C02PT6R: M- pole male connector Receiver with M-C02PT62RM: M- pole male connector + M- pole male connector Cable length (for power supply) 0 m max Light emission ( l ) Infrared, LED (90 nm) Resolution 14-30 mm Operating distance 0.2 20 m for 30 mm 0.2 7 m for 14 mm mbient light rejection ccording to IEC-61496-2:2013 Operating temperature 0 + 0 C Storage temperature - 2 + 70 C Humidity range 1 9 % (no condensation) Protection class IP6 (EN 6029:2000) Weight 1.3 kg / meter for each single unit Housing material Painted aluminium (yellow RL 1003) Front side material PMM Cap material PT Valox 08 Function settings at delivery The functions are configured with push-buttons on the units. No code Muting EDM enabled utomatic Reset T/X muting 10 min muting time-out Override trigger = level Long range * Two specific cables must be ordered with Orion1 Extended, one for the transmitter and one for the receiver. See next page.

Connection Connection transmitter (1) (2) Test (3) (4) Earth Grey () For the transmitter: M-C02PT2T Connection receiver with muting cable M-C02PT62RM M- connector (1) (2) (3) Reset/cknowledge/lign Green (4) Override1 Pink () OSSD2 Yellow (6) EDM (7) Muting selection Grey (8) Red (9) Violet (10) Grey-pink () Red-blue () OSSD1 Override2 Muting lamp Override status Earth For the receiver when muting: M-C02PT62RM M- connector (1) (2) (3) (4) Grey () Muting2 Muting1 Connection receiver with blanking cable M-C02PT6R, to be used whenever muting is not necessary. M- connector (1) (2) (3) Green (4) Pink () Yellow (6) (7) Grey (8) Red (9) Violet (10) Grey-pink () Red-blue () Reset/cknowledge/lign Teach in OSSD2 EDM OSSD1 Tolerance Lamp Earth For the receiver when no muting: M-C02PT6R * Colors according to standard cables Two specific cables must be ordered with Orion1 Extended, one for the transmitter and one for the receiver.

Connection examples Connection to a RT9 safety relay +24V +24V 1 Transmitter Receiver 1 +24V 2 TEST 2 3 RESET/CKN 3 ERTH 4 OVERRIDE1 4 Green OSSD2 Pink EDM 6 Yellow MUTING SELECTION 7 OSSD1 8 Grey OVERRIDE2 9 Red MUTING LMP 10 OVERRIDE STTUS Violett Grey / Pink K1 S14 S34 X1 X4 1 13 23 ERTH Red / RT9 1 - + 2 MUTING2 2 3 Muting sensors S13 S44 S24 Y14 14 24 MUTING1 4 ORION1 Extended 1 1 V2 V1 ORION1 Extended in muting mode with - manual reset - EDM deactivated Note: manual reset should be activated Connection to a Pluto 20 Safety PLC +24V +24V 1 Transmitter Receiver +24V 1 2 TEST 3 2 RESET/CKN 3 ERTH 4 OVERRIDE1 4 Green OSSD2 Pink EDM 6 Yellow MUTING SELECTION 7 OSSD1 8 Grey OVERRIDE2 9 Red MUTING LMP 10 Violett K10 OVERRIDE STTUS Grey / Pink CH CL I0 I1 I6 I7 +24V ERTH Red / Pluto bus Power Q3 Inputs, individual failsafe MUTING2 2 3 Muting sensors Pluto 20v2 MUTING1 4 Failsafe inputs / Indication outputs (not failsafe) / Dynamic outputs Relay output, individual failsafe ORION1 Extended I0 I1 I2 I7 Identifier input IDFIX Power 0L Q0 1L ID ORION1 Extended in muting mode with - manual reset - EDM deactivated 1 1 Note: manual reset should be activated V3 V4

Models and ordering information Orion1-4-14-030-E 2TL022301R0100 Orion1 Extended Transmitter + Receiver - R = 14 mm - H = 300 mm Orion1-4-14-04-E 2TL022301R0200 Orion1 Extended Transmitter + Receiver - R = 14 mm - H = 40 mm Orion1-4-14-060-E 2TL022301R0300 Orion1 Extended Transmitter + Receiver - R = 14 mm - H = 600 mm Orion1-4-14-07-E 2TL022301R0400 Orion1 Extended Transmitter + Receiver - R = 14 mm - H = 70 mm Orion1-4-14-090-E 2TL022301R000 Orion1 Extended Transmitter + Receiver - R = 14 mm - H = 900 mm Orion1-4-14-10-E 2TL022301R0600 Orion1 Extended Transmitter + Receiver - R = 14 mm - H = 100 mm Orion1-4-14-0-E 2TL022301R0700 Orion1 Extended Transmitter + Receiver - R = 14 mm - H = 00 mm Orion1-4-14-13-E 2TL022301R0800 Orion1 Extended Transmitter + Receiver - R = 14 mm - H = 130 mm Orion1-4-14-10-E 2TL022301R0900 Orion1 Extended Transmitter + Receiver - R = 14 mm - H = 100 mm Orion1-4-14-16-E 2TL022301R1000 Orion1 Extended Transmitter + Receiver - R = 14 mm - H = 160 mm Orion1-4-14-180-E 2TL022301R00 Orion1 Extended Transmitter + Receiver - R = 14 mm - H = 1800 mm Orion1-4-30-030-E 2TL022303R0100 Orion1 Extended Transmitter + Receiver - R = 30 mm - H = 300 mm Orion1-4-30-04-E 2TL022303R0200 Orion1 Extended Transmitter + Receiver - R = 30 mm - H = 40 mm Orion1-4-30-060-E 2TL022303R0300 Orion1 Extended Transmitter + Receiver - R = 30 mm - H = 600 mm Orion1-4-30-07-E 2TL022303R0400 Orion1 Extended Transmitter + Receiver - R = 30 mm - H = 70 mm Orion1-4-30-090-E 2TL022303R000 Orion1 Extended Transmitter + Receiver - R = 30 mm - H = 900 mm Orion1-4-30-10-E 2TL022303R0600 Orion1 Extended Transmitter + Receiver - R = 30 mm - H = 100 mm Orion1-4-30-0-E 2TL022303R0700 Orion1 Extended Transmitter + Receiver - R = 30 mm - H = 00 mm Orion1-4-30-13-E 2TL022303R0800 Orion1 Extended Transmitter + Receiver - R = 30 mm - H = 130 mm Orion1-4-30-10-E 2TL022303R0900 Orion1 Extended Transmitter + Receiver - R = 30 mm - H = 100 mm Orion1-4-30-16-E 2TL022303R1000 Orion1 Extended Transmitter + Receiver - R = 30 mm - H = 160 mm Orion1-4-30-180-E 2TL022303R00 Orion1 Extended Transmitter + Receiver - R = 30 mm - H = 1800 mm Cables M-C02PT2T 2TL02231R0100 Transmitter cable for Orion1 Extended M-C02PT6R 2TL02231R0200 Receiver cable for Orion1 Extended when no muting M-C02PT62RM 2TL02231R0300 Receiver cable for Orion1 Extended when muting PT-C1PT 2TL02231R1000 Cascade cable for Orion1 Extended, 1 m PT-C0PT 2TL02231R00 Cascade cable for Orion1 Extended, 0. m PT-C00PT 2TL02231R00 Cascade cable for Orion1 Extended, 0.0 m M-C61 2TL02006R0000 Straight M- female connector with 6 m shielded cable M-C101 2TL02006R1000 Straight M- female connector with 10 m shielded cable M-C201 2TL02006R1400 Straight M- female connector with 20 m shielded cable M-C6 2TL02006R7200 Straight M- female connector with 6 m shielded cable M-C10 2TL02006R7300 Straight M- female connector with 10 m shielded cable M-C20 2TL02006R700 Straight M- female connector with 20 m shielded cable Spare parts (delivered with products originally) JSM Orion01 2TL022310R0000 4 standard brackets for Orion1 & Orion2 ccessories Orion TP-14 2TL022310R200 Orion Test Piece 14 mm Orion TP-30 2TL022310R300 Orion Test Piece 30 mm Orion Laser 2TL022310R000 Orion Laser pointer JSM Orion01 2TL022310R0000 4 standard brackets for Orion1 & Orion2 JSM Orion06 2TL022310R0400 Kit for mounting of Orion1 & Orion2 in Stand (4 pieces) JSM Orion07 2TL022310R000 Kit for mounting of Orion1 & Orion2 in Stand (6 pieces) JSM Orion 2TL022310R0900 Kit for mounting of Orion1 Mirror in Stand Orion Stand Plate 2TL0223R000 Orion Plate kit for adjustment of protective stand Orion1 Mirror* Deviating mirror to be mounted in Orion Stand with 1 kit JSM Orion Orion Stand* Protective stand * These accessories are available in different sizes. More information on www.abb.com/jokabsafety.

Dimensions 2TLC17203L0201 ll dimensions in millimeters Model Lt (mm) L (mm) Orion1-4-xx-030-E 10 306.30 Orion1-4-xx-04-E 300 46.30 Orion1-4-xx-060-E 40 606.30 Orion1-4-xx-07-E 600 76.30 Orion1-4-xx-090-E 70 906.30 Orion1-4-xx-10-E 900 106.30 Orion1-4-xx-0-E 100 06.30 Orion1-4-xx-13-E 00 136.30 Orion1-4-xx-10-E 130 106.30 Orion1-4-xx-16-E 100 166.30 Orion1-4-xx-180-E 160 1806.30 xx = Resolution (14-30 mm) Varlabergsvägen SE-434 39 Kungsbacka Tel. +46 (0) 21-32 0 00 www.abb.com/jokabsafety