Sunlight Supply, Inc.

Similar documents
Sunlight Supply, Inc.

Stimwave Technologies, Inc.

Honeywell, Automation and Control Solutions

Honeywell, Automation and Control Solutions

Veris Industries, Inc.

DRAFT. Element Materials Technology. UltraTEV Plus2 FCC : MHz Radio. Report # ELEM NVLAP LAB CODE:

Onity Inc., A Division of UTCFS

Honeywell, Automation and Control Solutions

Electric Imp, Inc. IMP003-FCC FCC :2014. Report # ELIM NVLAP Lab Code:

Payrange. Blukey Module FCC :2016 FCC :2016 Bluetooth Low Energy Radio. Report # PAYR NVLAP Lab Code:

Sunlight Supply, Inc.

Intermec Technologies Corporation

Impinj, Inc. xspan RFID reader system. FCC :2016 FCC :2016 Bluetooth Low Energy Module. Report # IMPI NVLAP Lab Code:

Roche Diabetes, Inc.

FUJIFILM Sonosite Manufacturing, LLC

Measurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob

Itron, Inc. TEST REPORT FOR. RF Telemetry Device Model: CCU100. Tested To The Following Standards:

FCC 47 CFR PART 15 SUBPART B

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 CERTIFICATION TEST REPORT FOR. Dolphin CT50

Medtronic MiniMed TEST REPORT FOR. GST3 Glucose Sensor Transmitter, MMT-7763A. Tested To The Following Standards:

Masimo Corporation RDS7A/ROOT V2 FCC :2014 FCC :2014. Report # MASI0237 Rev. 1. NVLAP Lab Code:

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020

FCC Part 15 Subpart B

Frequency Range Peak Data Quasi-Peak Data Average Data (khz) (khz) (khz)

HID GLOBAL CORPORATION

FCC CLASS B COMPLIANCE REPORT (DoC)

QI HARDWARE INC. Ben NanoNote. Model: Ben NanoNote September Report No.: (This report supersedes NONE)

FCC PART 15 Subpart C EMI MEASUREMENT AND TEST REPORT

C-Tick EMC TEST REPORT. For. AC/DC Switching Power Supply

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-247 ISSUE 1 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR

TRANSMITTER MODEL: KAS-2030M

Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2

No. 620 HuaYuan Commercial Center, No. 347 XiXiang Road,XiXiang Town, Bao An District, ShenZhen City Tel : Fax:

OUTDOOR SOUND MODULE/TRANSMITTER MODEL: THE BANDIT

Test Report. Applicant ASUSTeK COMPUTER INC. 4F, No. 150, Li-Te Rd., Peitou, Taipei, Taiwan. Date of Receipt Jan. 28, Issued Date Mar.

TEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C

(b) The device is an FCC device. The Vertical Antenna, Part Number The Horizontal Antenna, Part Number

HID GLOBAL CORPORATION

Measurement of RF Interference from a Canopy 900MHz Access Point and Subscriber Module Using A Yagi Antenna

Palstar, Inc. EMC TEST REPORT FOR. HF LDMOS Amplifier Model: LA-1K. Tested To The Following Standard: FCC Part 97 Subpart D. Report No.

416 Maetan 3-Dong, Yeongtong-Gu, Suwon-Si, Gyeonggi-Do, Korea,

FCC CFR47 PART 15 SUBPART C CERTIFICATION TEST REPORT FOR THE FUEL WEB, INC. GATEWAY MODULE MODEL: GWM-P-SHRF-1 FCC ID: PX5-GWM1001

FCC CFR47 PART 15 SUBPART C CERTIFICATION TEST REPORT FOR DUAL RADIO OUTDOOR ACCESS POINT MODEL NUMBER: AP-ONE FCC ID: SWX-AP1R2

HID GLOBAL CORPORATION

TEST REPORT. Table of Contents

FCC 47 CFR PART 15 SUBPART B CERTIFICATION TEST REPORT FOR a/b/g/n/ac 3X3 WLAN + Bluetooth Combo PCI-E Mini Card MODEL NUMBER: BCM94360CS

ECHOSTAR 54.0 BRISBANE VOICE REMOTE 2017 MODEL: URC-2027BC0-R

Test Report. Product Name: Wireless 11g USB Adapter Model No. : MS-6826, UB54G FCC ID. : DoC

Intel Corporation. Corporate Product Regulations. Ferrite Clamp/Tube Analysis CISPR/G/143/CDV. 22 December 1999

CERTIFICATE. Issued Date: Apr. 20, 2006 Report No.: 064L079-IT-US-P01V01

RADIO TEST REPORT. For MODEL NO FCC ID: C3K1703 IC ID: 3048A Test Report No. R-TR190-FCCIC-UNII-1 Issue Date: 14 September 2015

ICES-003, Issue 5, August Radiated and Conducted Emissions VCCI. Member #: 2649 Registration #: A-0170 R-3273 C-3642 T-1756 G-233

Medtronic MiniMed ADDENDUM TO TEST REPORT A. Carelink USB 2.4 Model: MMT-7306CL. Tested To The Following Standards:

FCC Certification Test Report for the MEI Cashflow RFID Reader Base FCC ID: QP8EASITRAXRB

TEST REPORT. Table of Contents

FCC Rules and Regulations / Intentional Radiators. Operational in the MHz, MHz, MHz, and

PAX Technology Limited

L.S. Compliance, Inc. W66 N220 Commerce Court Cedarburg, WI

FCC Test Report. Report No.: AGC FE01 2AAP6UB15MSKB. Attestation of Global Compliance (Shenzhen) Co., Ltd

FCC 47 CFR PART 15 SUBPART B TEST REPORT. For. External USB 2.0 HDD Enclosure

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-247 ISSUE 1 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR

FCC 47 CFR PART 15 SUBPART C CERTIFICATION TEST REPORT FOR. RF ID Reader MODEL NUMBER: A-405 FCC ID: WFQITCS-A-405 IC: 10717A-ITCSA405

EMC TEST REPORT for Repel-it. REPEL-IT ULTRASONIC PEST REPELLER Model No. : REPEL-IT/UPR/AN-B019

ELECTRONICS TESTING CENTER, TAIWAN

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-GEN AND RSS-210 CERTIFICATION TEST REPORT FOR BROADCOM BLUETOOTH MODULE MODEL NUMBER: BCM92046MD

ENGINEERING TEST REPORT

CERTIFICATE. Issued Date: Apr. 02, 2009 Report No.: R-ITUSP01V01

TEST REPORT. Report Number: MIN-001 Rev 1.1 Project Number: G Testing performed on the 2102 IPG

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Trade Name : Activision. Model Number: / FCC ID: XLU

FCC Test Report. Report No.: AGC FE08. Attestation of Global Compliance (Shenzhen) Co., Ltd

HID GLOBAL CORPORATION

Nemko-CCL, Inc West Alexander Street Salt Lake City, UT

Deon Dai Engineer Reviewer

FCC Verification TEST REPORT

UEI FUSION PLUS QWERTY KB REMOTE 2012 MODEL: URC-5110BC0-XXX-R

FCC PART 15B TEST AND MEASUREMENT REPORT. AOR USA Inc.

FCC Test Report. Report No.: AGC FE08 MODEL NAME : TH 9800,TH 9800D,TH 7800,TH 7900 CLIENT : TYT ELECTRONICS CO., LTD

FCC 47 CFR PART 15 SUBPART C CERTIFICATION TEST REPORT FOR. Bluetooth Remote Control for Video Set Top Box MODEL NUMBER: IPRC1000 FCC ID: 2ABTE-L3YJC9

Tested To The. and. Report. We strive to TESTING

COMCAST XFINITY HOME MOTION SENSOR MODEL: URC4470BC0-X-R

FCC DOC TEST REPORT. According to. 47 CFR, Part 2, Part 15, CISPR PUB. 22, ICES 003 Issue 6

INGEGNERIA DEI SISTEMI S.P.A

FCC PART MEASUREMENT AND TEST REPORT FOR. Guangzhou Walkera Technology CO., LTD

FCC CFR47 PART 15 SUBPART C CERTIFICATION TEST REPORT FOR PCMCIA RFID READER CARD MODEL NUMBER: MPR6000 FCC ID: NTTWJMPR6XXX REPORT NUMBER: 04U2954-3

C E R T I F I C A T I O N

Declaration of Conformity (DoC)

FCC CFR47 PART 15 SUBPART C BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. GSM/WCDMA/LTE Phone + BT/BLE, DTS/UNII a/b/g/n/ac, NFC and ANT+

Test Report. Product Name : IPC Model No.

T A B L E O F C O N T E N T S DESCRIPTION PAGE

FCC PART 15, SUBPART C TEST AND MEASUREMENT REPORT. CentraLite Systems Inc.

Global EMC Inc. Labs EMC & RF Test Report TVTXP916A04

VCCI TEST REPORT. According to. Class B ITE. Equipment : USB video camera

Quality Auditing Institute # Schoolhouse Street, Coquitlam, BC, V3K 4X9, Canada. ISO Accreditation:

TRANSMITTER Model: TX24

Test Report: 5R Champlain Street Dieppe, New Brunswick Canada E1A 1P6. Model Number: Verification

FCC PART 15 Subpart C EMI MEASUREMENT AND TEST REPORT

REVISION HISTORY. The revision history for this document is shown in table. HCT-EM-1801-FC037 January 22, 2018 Initial Release

FCC PART 15C IC RSS-210, ISSUE 7, JUNE 2007 TEST AND MEASUREMENT REPORT. SunPower Corporation

TEST REPORT CONCERNING THE COMPLIANCE OF PART 15 JBP

Itron, Inc. TEST REPORT FOR. AMR Transceiver Device for Endpoint Installation Model: 900 BCR. Tested To The Following Standards:

Transcription:

Sunlight Supply, Inc. Grow Amp 1000w Model: 902227 Report #: SNSY0009 Report Prepared By Northwest EMC Inc. NORTHWEST EMC (888) 364-2378 www.nwemc.com California Minnesota Oregon New York Washington

CERTIFICATE OF TEST WTD 12.5.23 Last Date of Test: July 14, 2014 Sunlight Supply, Inc. Grow Amp 1000w Model: 902227 Emissions Test Description Specification Test Method Pass/Fail Radiated Emissions FCC 18.305:2014 Consumer equipment MP-5:1986 Pass Conducted Emissions FCC 18.307:2014 Consumer equipment MP-5:1986 Pass Deviations From Test Standards None Approved By: Kyle Holgate, Operations Manager NVLAP Lab Code: 200630-0 This report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government of the United States of America. Product compliance is the responsibility of the client, therefore the tests and equipment modes of operation represented in this report were agreed upon by the client, prior to testing. This Report may only be duplicated in its entirety. The results of this test pertain only to the sample(s) tested. The specific description is noted in each of the individual sections of the test report supporting this certificate of test. Report No. SNSY0009 2/21

REVISION HISTORY REV 2012.08.02 Revision Number Description Date Page Number 00 None Barometric Pressure The recorded barometric pressure has been normalized to sea level. Report No. SNSY0009 3/21

REV 2012.05.24 ACCREDITATIONS AND AUTHORIZATIONS United States FCC - Designated by the FCC as a Telecommunications Certification Body (TCB). Certification chambers, Open Area Test Sites, and conducted measurement facilities are listed with the FCC. A2LA - Accredited by A2LA to ISO / IEC Guide 65 as a product certifier. This allows Northwest EMC to certify transmitters to FCC and IC specifications. NVLAP - Each laboratory is accredited by NVLAP to ISO 17025 Canada IC - Recognized by Industry Canada as a Certification Body (CB). Certification chambers and Open Area Test Sites are filed with IC. European Union European Commission Validated by the European Commission as a Conformity Assessment Body (CAB) under the EMC directive and as a Notified Body under the R&TTE Directive. Australia/New Zealand ACMA - Recognized by ACMA as a CAB for the acceptance of test data. Korea Japan KCC / RRA - Recognized by KCC s RRA as a CAB for the acceptance of test data. VCCI - Associate Member of the VCCI. Conducted and radiated measurement facilities are registered. Taiwan BSMI Recognized by BSMI as a CAB for the acceptance of test data. NCC - Recognized by NCC as a CAB for the acceptance of test data. Singapore IDA Recognized by IDA as a CAB for the acceptance of test data. Hong Kong OFTA Recognized by OFTA as a CAB for the acceptance of test data. Vietnam MIC Recognized by MIC as a CAB for the acceptance of test data. Russia GOST Accredited by Certinform VNIINMASH, CERTINFO, SAMTES, and Federal CHEC to perform EMC and Hygienic testing for Information Technology products to GOST standards. SCOPE For details on the Scopes of our Accreditations, please visit: http://www.nwemc.com/accreditations/ Report No. SNSY0009 4/21

EMISSIONS MEASUREMENTS REV 2013.12.13 Measurement Uncertainty When a measurement is made, the result will be different from the true or theoretically correct value. The difference is the result of tolerances in the measurement system that cannot be completely eliminated. To the extent that technology allows us, it has been our aim to minimize this error. Measurement uncertainty is a statistical expression of measurement error qualified by a probability distribution. A measurement uncertainty estimation has been performed for each test per our internal quality document WP 342. The estimation is used to compare the measured result with its "true" or theoretically correct value. The expanded measurement uncertainty (K=2) can be found included as part of the applicable test description page. Our measurement data meets or exceeds the measurement uncertainty requirements of the applicable specification; therefore, the test data can be compared directly to the specification limit to determine compliance. The calculations for estimating measurement uncertainty are based upon ETSI TR 100 028 (or CISPR 16-4-1 as applicable), and are available upon request. Measurement Bandwidths Frequency Range Peak Data Quasi-Peak Data Average Data (MHz) (khz) (khz) (khz) 0.01-0.15 1.0 0.2 0.2 0.15-30.0 10.0 9.0 9.0 30.0-1000 100.0 120.0 120.0 Above 1000 1000.0 N/A 1000.0 Measurements were made using the bandwidths and detectors specified. No video filter was used. Sample Calculations Radiated Emissions: Field Strength Measured Level Antenna Factor Cable Factor Amplifier Gain Distance Adjustment Factor External Attenuation 33.5 = 42.6 + 28.6 + 3.1-40.8 + 0.0 + 0.0 Conducted Emissions: Adjusted Measured Transducer Cable External Level Level Factor Factor Attenuation 47.1 = 26.7 + 0.3 + 0.1 + 20.0 Report No. SNSY0009 5/21

FACILITIES REV 2013.06.28 Oregon Labs EV01-12 22975 NW Evergreen Pkwy Hillsboro, OR 97124 (503) 844-4066 California Labs OC01-13 41 Tesla Irvine, CA 92618 (949) 861-8918 New York Labs NY01-04 4939 Jordan Rd. Elbridge, NY 13060 (315) 685-0796 VCCI Minnesota Labs MN01-08 9349 W Broadway Ave. Brooklyn Park, MN 55445 (763) 425-2281 A-0108 A-0029 A-0109 A-0110 Industry Canada 2834D-1, 2834D-2 2834B-1, 2834B-2, 2834B-3 2834E-1 2834F-1 NVLAP Washington Labs NC01-05,SU02,SU07 19201 120 th Ave. NE Bothell, WA 98011 (425) 984-6600 NVLAP Lab Code: 200630-0 NVLAP Lab Code: 200676-0 NVLAP Lab Code: 200761-0 NVLAP Lab Code: 200881-0 NVLAP Lab Code: 200629-0 Report No. SNSY0009 6/21

PRODUCT DESCRIPTION WTD 12.5.23 Client and Equipment Under Test (EUT) Information Company Name: Sunlight Supply, Inc. Address: 5408 NE 88th Street, Bldg A City, State, Zip: Vancouver, WA 98665 Test Requested By: Ken Garver Model: Grow Amp 1000w Model: 902227 First Date of Test: July 14, 2014 Last Date of Test: July 14, 2014 Receipt Date of Samples: July 14, 2014 Equipment Design Stage: Production Equipment Condition: No Damage Information Provided by the Party Requesting the Test Functional Description of the EUT (Equipment Under Test): 1000W Grow Amp Testing Objective: These tests were selected to satisfy the EMC requirements requested by the client. EUT Photo Report No. SNSY0009 7/21

CONFIGURATIONS WTD 12.5.23 Configuration SNSY0009-1 EUT Description Manufacturer Model/Part Number Serial Number 1000W Grow Amp Sunlight Supply, Inc. 902227 None Peripherals in test setup boundary Description Manufacturer Model/Part Number Serial Number Reflector Sunlight Supply Inc. Sun System Yield Master II 904665 None Cables Cable Type Shield Length (m) Ferrite Connection 1 Connection 2 AC Power No 2m No AC Mains Digital Ballast AC Power No 4.5m No Digital Ballast Reflector PA = Cable is permanently attached to the device. Shielding and/or presence of ferrite may be unknown. Report No. SNSY0009 8/21

MODIFICATIONS WTD 12.5.23 Equipment Modifications Item Date Test Modification Note Disposition of EUT Tested as No EMI suppression EUT remained at Conducted 1 7/14/2014 delivered to devices were added or Northwest EMC Emissions Test Station. modified during this test. following the test. 2 7/14/2014 Radiated Emissions Tested as delivered to Test Station. No EMI suppression devices were added or modified during this test. Scheduled testing was completed. Report No. SNSY0009 9/21

RADIATED EMISSIONS WTD.2013.07.23, PSA-ESCI 2014.06.19, EmiR5 2014.03.06 TEST DESCRIPTION Using the mode of operation and configuration noted within this report, a final radiated emissions test was performed. The frequency range investigated (scanned), is also noted in this report. Radiated emissions measurements were made at the EUT azimuth and antenna height such that the maximum radiated emissions level was detected. This required the use of a turntable and an antenna positioner. The preferred method of a continuous azimuth search was utilized for frequency scans of the EUT field strength with both polarities of the measuring antenna. A calibrated, linearly polarized antenna was positioned at the specified distance from the periphery of the EUT. Tests were made with the antenna positioned in both the horizontal and vertical planes of polarization. The antenna was varied in height above the conducting ground plane to obtain the maximum signal strength. Though specified in the report, the measurement distance was 3 meters or 10 meters. At any measurement distance, the antenna height was varied from 1 meter to 4 meters. These height scans apply for both horizontal and vertical polarization, except that for vertical polarization the minimum height of the center of the antenna was increased so that the lowest point of the bottom of the antenna cleared the ground surface by at least 25 cm. The EUT arrangement is configured as equivalent to that occurring in normal use. Tabletop equipment is placed on a 0.8 meter high non-conductive table & for Floor-standing equipment, it is placed on, but insulated from a ground reference plane by the use of its own rollers or stand-off supports. If measurements above 1 GHz were required, the test setup was modified to meet the regulatory requirements for higher frequency measurements. If required, RF absorber was placed on the floor between the measurement antenna and EUT. The diameter of the illumination area is the dimension of the line tangent to the EUT formed by 3 db beamwidth of the measurement antenna at the measurement distance. At a 3 meter test distance, the diameter of the illumination area was 3.8 meters at 1 GHz and greater than 2.1 meters up to 6 GHz. Above 1 GHz, when required by the measurement standard, the antenna is pointed for both azimuth and elevation to maintain the receive antenna within the cone of radiation from the EUT. The specified measurement detectors were used for comparison of the emissions to the peak and average specification limits. TEST EQUIPMENT Description Manufacturer Model ID Last Cal. Interval Spectrum Analyzer Agilent E4443A AFB 02/12/2014 12 mo Antenna, Biconilog EMCO 3141 AXE 03/07/2012 36 mo Pre-Amplifier Miteq AM-1551 AOY 09/03/2013 12 mo EV11 Cables N/A 10m Test Distance Cables EVL 09/03/2013 12 mo MEASUREMENT UNCERTAINTY Description Expanded k=2 4.3 db -4.3 db FREQUENCY RANGE INVESTIGATED 30 MHz TO 1000 MHz POWER INVESTIGATED 277VAC/60Hz CONFIGURATIONS INVESTIGATED SNSY0009-1 MODES INVESTIGATED Set to 1000W Report No. SNSY0009 10/21

RADIATED EMISSIONS WTD.2013.07.23, PSA-ESCI 2014.06.19, EmiR5 2014.03.06 EUT: Grow Amp 1000w Model: 902227 Work Order: SNSY0009 Serial Number: None Date: 07/14/2014 Customer: Sunlight Supply, Inc. Temperature: 25.4 C Attendees: None Relative Humidity: 47.5% Customer Project: None Bar. Pressure: 1020.3 mb Tested By: Cole Ghizzone Job Site: EV11 Power: 277VAC/60Hz Configuration: SNSY0009-1 TEST SPECIFICATIONS Specification: Non-consumer equipment FCC 18.305:2014 Method: MP-5:1986 TEST PARAMETERS Run #: 1 Test Distance (m): 10 Ant. Height(s) (m): 1 to 4(m) COMMENTS Allowed 15 minutes to warm up. EUT OPERATING MODES Set to 1000W DEVIATIONS FROM TEST STANDARD None 80 70 60 50 dbuv/m 40 30 20 10 0 10 100 1000 MHz Run #: 1 Report No. SNSY0009 11/21

RADIATED EMISSIONS WTD.2013.07.23, PSA-ESCI 2014.06.19, EmiR5 2014.03.06 RESULTS - Run #1 Freq (MHz) Amp. (dbuv) Factor Ant. Height (m) Azimuth (deg.) Test Dist. (m) Ext. Atten. Polar. Trans. Type Detect. Dist. Adjust. Adj. (dbuv/m) Spec. Limit (dbuv/m) 48.675 60.6-26.1 1.0 120.0 10.0 0.0 Vert QP -9.5 25.0 30.0-5.0 64.788 62.4-28.0 3.8 179.0 10.0 0.0 Horz QP -9.5 24.9 30.0-5.1 82.488 60.4-28.1 4.0 223.0 10.0 0.0 Horz QP -9.5 22.7 30.0-7.3 114.738 61.7-26.8 3.8 127.0 10.0 0.0 Horz QP -9.5 25.3 33.5-8.2 99.016 56.6-26.5 3.8 67.0 10.0 0.0 Horz QP -9.5 20.6 33.5-12.9 327.233 42.3-18.7 2.7 148.0 10.0 0.0 Horz QP -9.5 14.0 36.0-22.0 324.780 38.8-18.8 2.0 346.0 10.0 0.0 Horz QP -9.5 10.5 36.0-25.5 CONCLUSION Pass Margin. Tested By Report No. SNSY0009 12/21

RADIATED EMISSIONS WTD.2013.07.23, PSA-ESCI 2014.06.19, EmiR5 2014.03.06 Report No. SNSY0009 13/21

RADIATED EMISSIONS WTD.2013.07.23, PSA-ESCI 2014.06.19, EmiR5 2014.03.06 Report No. SNSY0009 14/21

CONDUCTED EMISSIONS WTD.2013.07.23, PSA-ESCI 2014.06.19, EmiR5 2014.07.09 TEST DESCRIPTION Using the mode of operation and configuration noted within this report, conducted emissions tests were performed. The frequency range investigated (scanned), is also noted in this report. Conducted power line measurements are made, unless otherwise specified, over the frequency range from 150 khz to 30 MHz to determine the line-to-ground radio-noise voltage that is conducted from the EUT power-input terminals that are directly (or indirectly via separate transformer or power supplies) connected to a public power network. Equipment is tested with power cords that are normally used or that have electrical or shielding characteristics that are the same as those cords normally used. Typically those measurements are made using a LISN (Line Impedance Stabilization Network), the 50 Ω measuring port is terminated by a 50 Ω EMI meter or a 50 Ω resistive load. All 50 Ω measuring ports of the LISN are terminated by 50Ω. TEST EQUIPMENT Description Manufacturer Model ID Last Cal. Interval Receiver Rohde & Schwarz ESCI ARH 02/05/2014 12 mo High Pass Filter TTE H97-100K-50-720B HHD 01/22/2014 12 mo Attenuator Fairview Microwave SA6B10W-20 RKA 10/24/2013 12 mo EV07 Cables N/A Conducted Cables EVG 03/07/2014 12 mo LISN (3 Phase) Fischer Custom Communications FCC-LISN-50-200-4-02 LIU 04/10/2014 12 mo MEASUREMENT UNCERTAINTY Description Expanded k=2 2.94 db -2.94 db CONFIGURATIONS INVESTIGATED SNSY0009-1 MODES INVESTIGATED Set to 1000W Report No. SNSY0009 15/21

CONDUCTED EMISSIONS WTD.2013.07.23, PSA-ESCI 2014.06.19, EmiR5 2014.07.09 EUT: Grow Amp 1000w Model: 902227 Work Order: SNSY0009 Serial Number: None Date: 07/14/2014 Customer: Sunlight Supply, Inc. Temperature: 24.3 C Attendees: None Relative Humidity: 47.1% Customer Project: None Bar. Pressure: 1020.3 mb Tested By: Cole Ghizzone Job Site: EV07 Power: 277VAC/60Hz Configuration: SNSY0009-1 TEST SPECIFICATIONS Specification: Non consumer equipment FCC 18.307:2014 Method: MP-5:1986 TEST PARAMETERS Run #: 4 Line: High Line Ext. Attenuation : 20 COMMENTS Allowed 15 minutes to warm up. EUT OPERATING MODES Set to 1000W DEVIATIONS FROM TEST STANDARD None Quasi Peak Data - vs - Quasi Peak Limit Average Data - vs - Average Limit 100 100 90 90 80 80 70 70 60 60 dbuv 50 40 dbuv 50 40 30 30 20 20 10 10 0 0 1 10 100 MHz 0 0 1 10 100 MHz Report No. SNSY0009 16/21

CONDUCTED EMISSIONS WTD.2013.07.23, PSA-ESCI 2014.06.19, EmiR5 2014.07.09 RESULTS - Run #4 Quasi Peak Data - vs - Quasi Peak Limit Spec. Limit (() Average Data - vs - Average Limit Freq (MHz) Amp. (dbuv) Factor Adjusted (() Margin Freq (MHz) Amp. (dbuv) Factor Adjusted (() Margin 7.575 30.9 19.5 50.4 69.5-19.1 7.575 24.3 19.5 43.8 69.5-25.7 7.380 30.8 19.5 50.3 69.5-19.2 7.500 24.2 19.5 43.7 69.5-25.8 7.500 30.7 19.5 50.2 69.5-19.3 7.380 23.9 19.5 43.4 69.5-26.1 7.241 30.5 19.5 50.0 69.5-19.5 7.782 23.6 19.5 43.1 69.5-26.4 7.782 30.1 19.5 49.6 69.5-19.9 7.241 23.4 19.5 42.9 69.5-26.6 7.095 29.4 19.5 48.9 69.5-20.6 8.113 22.8 19.5 42.3 69.5-27.2 7.958 29.1 19.5 48.6 69.5-20.9 16.538 22.2 19.8 42.0 69.5-27.5 8.113 29.1 19.5 48.6 69.5-20.9 7.095 22.5 19.5 42.0 69.5-27.5 8.439 27.9 19.5 47.4 69.5-22.1 7.958 22.2 19.5 41.7 69.5-27.8 16.538 27.2 19.8 47.0 69.5-22.5 8.439 21.4 19.5 40.9 69.5-28.6 CONCLUSION Pass Spec. Limit (() Tested By Report No. SNSY0009 17/21

CONDUCTED EMISSIONS WTD.2013.07.23, PSA-ESCI 2014.06.19, EmiR5 2014.07.09 EUT: Grow Amp 1000w Model: 902227 Work Order: SNSY0009 Serial Number: None Date: 07/14/2014 Customer: Sunlight Supply, Inc. Temperature: 24.3 C Attendees: None Relative Humidity: 47.1% Customer Project: None Bar. Pressure: 1020.3 mb Tested By: Cole Ghizzone Job Site: EV07 Power: 277VAC/60Hz Configuration: SNSY0009-1 TEST SPECIFICATIONS Specification: Non-consumer equipment FCC 18.307:2014 Method: MP-5:1986 TEST PARAMETERS Run #: 5 Line: Neutral Ext. Attenuation : 20 COMMENTS Allowed 15 minutes to warm up. EUT OPERATING MODES Set to 1000W DEVIATIONS FROM TEST STANDARD None Quasi Peak Data - vs - Quasi Peak Limit Average Data - vs - Average Limit 100 100 90 90 80 80 70 70 60 60 dbuv 50 40 dbuv 50 40 30 30 20 20 10 10 0 0 1 10 100 MHz 0 0 1 10 100 MHz Report No. SNSY0009 18/21

CONDUCTED EMISSIONS WTD.2013.07.23, PSA-ESCI 2014.06.19, EmiR5 2014.07.09 RESULTS - Run #5 Quasi Peak Data - vs - Quasi Peak Limit Spec. Limit (() Average Data - vs - Average Limit Freq (MHz) Amp. (dbuv) Factor Adjusted (() Margin Freq (MHz) Amp. (dbuv) Factor Adjusted (() Margin 7.441 31.2 19.5 50.7 69.5-18.8 7.441 24.4 19.5 43.9 69.5-25.6 7.571 31.1 19.5 50.6 69.5-18.9 7.571 24.3 19.5 43.8 69.5-25.7 7.300 30.9 19.5 50.4 69.5-19.1 7.712 24.1 19.5 43.6 69.5-25.9 7.384 30.9 19.5 50.4 69.5-19.1 7.789 23.9 19.5 43.4 69.5-26.1 7.712 30.8 19.5 50.3 69.5-19.2 7.300 23.8 19.5 43.3 69.5-26.2 7.789 30.5 19.5 50.0 69.5-19.5 7.384 23.8 19.5 43.3 69.5-26.2 7.171 30.4 19.5 49.9 69.5-19.6 16.409 23.2 19.8 43.0 69.5-26.5 7.234 30.4 19.5 49.9 69.5-19.6 7.919 23.5 19.5 43.0 69.5-26.5 7.919 30.1 19.5 49.6 69.5-19.9 7.234 23.4 19.5 42.9 69.5-26.6 8.079 29.0 19.5 48.5 69.5-21.0 7.171 23.0 19.5 42.5 69.5-27.0 8.328 28.7 19.5 48.2 69.5-21.3 8.328 22.2 19.5 41.7 69.5-27.8 16.409 28.3 19.8 48.1 69.5-21.4 8.079 21.6 19.5 41.1 69.5-28.4 CONCLUSION Pass Spec. Limit (() Tested By Report No. SNSY0009 19/21

CONDUCTED EMISSIONS WTD.2013.07.23, PSA-ESCI 2014.06.19, EmiR5 2014.07.09 Report No. SNSY0009 20/21

CONDUCTED EMISSIONS WTD.2013.07.23, PSA-ESCI 2014.06.19, EmiR5 2014.07.09 Report No. SNSY0009 21/21