MDS-21 Absorbing Clamp, EZ-24 Ferrite Clamp

Similar documents
ENY81 Coupling Network

R&S ZV-Z5x Calibration Units Specifications

R&S ENV216 Two-Line V-Network For disturbance voltage measurements on single-phase EUTs

R&S ZV-Z5x Calibration Units Specifications

Vector Network Analyzers ZVB

Complimentary Reference Material

R&S CMU-Z10/-Z11 Antenna Coupler/ RF Shielding Cover Simple interference-free testing of all mobiles

R&S ZN-Z5x Calibration Units Specifications. Data Sheet V03.00

R&S ZN-Zxxx Calibration Units Specifications. Data Sheet V04.00

R&S RSC Step Attenuator Specifications

R&S ZVT Vector Network Analyzer Specifications

R&S ZV-Z3xx T-Checker Specifications

Voltage Sensors URV5-Z

HF Transmit/Receive Broadband System XB 2900

R&S ZVT Vector Network Analyzer Specifications

R&S ZV-Z135 Calibration Kit Specifications

Electromagnetic Compatibility

R&S FSC Spectrum Analyzer Specifications

R&S ZNC Vector Network Analyzer Specifications

R&S ZNB Vector Network Analyzer Specifications

Attenuators and Matching Pads, Terminations 75 mw to 1000 W, DC to 18 GHz

Spectrum Analyzer FSL

Application Firmware for Phase Noise Measurements FS-K40

R&S FU129 Antenna Filter Unit Antenna switching, rotator control and signal attenuation, amplification and filtering

R&S FSH4/8 Spectrum Analyzer Specifications

Radio Network Analyzer TSMU/TSMU-H

R&S ZVA-Zxx Millimeter-Wave Converters Network analysis up to 500 GHz

R&S NRPM Over-the-Air (OTA) Power Measurement Solution For 5G, WLAN IEEE ad and IEEE ay

ABSORBING CLAMP MDS. System Meyer de Stadelhofen / Lüthi

R&S ZNBT8 Vector Network Analyzer Specifications

R&S FSV Signal and Spectrum Analyzer Specifications

EMI Test Receivers ESIB

Coupling/Decoupling Networks (CDN)

Signal Generator SMA100A

Specification for Conducted Emission Test

Noise Figure Measurement Applications Specifications

R&S ESCI/ESCI7 EMI Test Receiver Specifications

Coupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC and CISPR 15 / CISPR 22 IEC

R&S EB500 Monitoring Receiver Specifications

ESU EMI Test Receiver

TEST REPORT... 1 CONTENT...

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

RF Signal Generator SM300

Analog Modulation Analysis (AM/FM/φM) Specifications

R&S FSV Signal Analyzer Specifications

Noise Figure Measurement in the 60 GHz Range Application Note

R&S ZVL Vector Network Analyzer Specifications

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 2.8GHz.

Measuring Receiver FSMR

Guide Version Five techniques for fast, accurate power integrity measurements

Coupling/Decoupling Networks (CDN)

Automation of a Clamp Mechanism for EMC Testing

R&S TS8997 Regulatory Test System for Wireless Devices

CENTRE OF TESTING SERVICE INTERNATIONAL

Power Added Efficiency Measurement with R&S ZNB/ R&S ZVA


HZ530 Near-Field Probe Set

ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 1GHz

R&S FS-K112PC NFC Measurement Software Specifications

R&S TS-EMF EMF Measurement System Easy, frequency-selective measurement of EMF emissions

Coupling / decoupling network (CDN) for screened or coaxial cables

Current Probes. User Manual

Spectrum Analyzer FSU

A Proposed Specification for RFI Ingress Limit in 802.3ch Automotive Links. Ramin Farjadrad Larry Cohen Aquantia Corp.

Signal Generator SMA 100A

R&S MNT100 RF Interference Locator Specifications

Handheld Spectrum Analyzer R&S FSH 3

FMU36 Baseband Signal Analyzer

Special testing of 100 ohm unshielded channel, Class E. Performed for HCS KABLOLAMA SISTEMLERI SAN.VE TIS.A.S.

Signal Generator SML

Test Systems. VSQ 3000/3002 Reference Radiation Source up to 3GHz

TSMU/TSMU-H Radio Network Analyzer

R&S ZVH Cable and Antenna Analyzer Specifications

Handheld Spectrum Analyzer R&S FSH3

Handheld Spectrum Analyzer R&S FSH3

Two Line V-Network GLN-5040A USER MANUAL GW INSTEK PART NO. 99 Washington Street Melrose, MA Phone Toll Free

R&S FPC Spectrum Analyzer Specifications

EMC TEST REPORT for Repel-it. REPEL-IT ULTRASONIC PEST REPELLER Model No. : REPEL-IT/UPR/AN-B019

Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission

R&S SMC100A Signal Generator Specifications

EFFECT OF SHIELDING ON CABLE RF INGRESS MEASUREMENTS LARRY COHEN

Advanced Test Equipment Rentals ATEC (2832)

COUPLING / DECOUPLING NETWORK (CDN) CDN AF TYPE, CDN CAN

SAC-10 Plus Triton Class

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

INTRODUCTION TO CONDUCTED EMISSION

Temposonics. Magnetostrictive Linear Position Sensors. EP2 Analog Data Sheet

R&S CBT/R&S CBT32 Bluetooth Tester Specifications

Handheld Spectrum Analyzer R&S FSH khz to 3 GHz

R&S ZNA Vector Network Analyzer Specifications

IST EMC LAB. EMISSION TEST REPORT. : DSP-4284GM Basic Alternate. : PDP(Plasma Display Panel) : Daewoo Electronics Corp. : Daewoo Electronics Corp.

IEC Electrical fast transient / Burst immunity test

Complimentary Reference Material

Ileana-Diana Nicolae ICMET CRAIOVA UNIVERSITY OF CRAIOVA MAIN BUILDING FACULTY OF ELECTROTECHNICS

EMC Test Report. Report Number: M030826

An Introduction to EMC Testing (what can be done with scopes) Vincent Lascoste EMC Product Manager - RSF

Narda DF Antennas - Datasheet. Datasheet

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

Transcription:

Version 06.00 MDS-21 Absorbing Clamp, EZ-24 Ferrite Clamp July 2007 Measurement of disturbance power and screening effectiveness on cables Reproducible measurements of disturbance field strength and disturbance power MDS-21 for 30 MHz to 1000 MHz EZ-24 for 1 MHz to 1000 MHz for improved reproducibility of disturbance field strength measurements Calibrated in accordance with CISPR Publ. 16-1-3 MDS-21 with ball bearing rollers for continuous use in automatic measurements Maximum diameter of cable 20 mm for MDS-21 22 mm for EZ-24 Clamps can be opened to put in cable to be tested

MDS-21 absorbing clamp, EZ-24 ferrite clamp The disturbance emitted by electrical appliances, machines, and systems must comply with the limits specified by national and international standards. Absorbing clamps (MDS clamps) in conjunction with EMI measuring receivers are used to measure the disturbance power on cables in accordance with CISPR 13 or EN 55013, in accordance with CISPR 14 1 or EN 55014-1, as well as in accordance with EN 50083-2. They can also be used in conjunction with twoport measuring devices to measure the screening effectiveness of cables in accordance with DIN 47250 Part 6, IEC 96 1, and EN 50083 2. The MDS clamps are also used to test the efficiency of disturbance suppression devices for high voltage ignition systems in accordance with CISPR 12 or EN 55012. Drafts on the measurement of radiated emission call for ferrite absorbers to load cables in order to improve the reproducibility of disturbance field strength measurements. Ferrite absorbers are also useful to improve the measurements of disturbance power and screening effectiveness. Measuring disturbance in the VHF/UHF range In the frequency range below 30 MHz, the interference stipulated in many standards is defined by measuring the disturbance voltage produced by the EUT at the terminals of a line-impedance stabilization network. This is important because disturbance in this frequency range is mainly propagated via cables. In the VHF/UHF range, where radiated disturbance is predominant, the interference is defined by the disturbance field strength at a certain distance. Small EUTs mainly emit disturbance via closed cables, e.g. power cables. For this reason and also to reduce extensive field strength measurements to a minimum, many standards stipulate the MDS clamp to measure the disturbance power. Measurement methods and test setups Disturbance power measurement A ferrite absorber provided in the MDS clamp surrounds the power cable and acts as resistance for the high-frequency RFI power. The incoming current is measured at the absorber input by using a current transformer and an EMI measuring receiver. Since there is no matching between the disturbance source, the cable, and the absorber in this setup, the MDS clamp is slid along the cable to obtain maximum current. By selecting suitable absorber material and correctly dimensioning the current transformer, the dbµv readout of an EMI measuring receiver is almost identical to a dbpw readout. A corresponding calibration certificate is part of the equipment supplied. 2 MDS-21 Absorbing Clamp, EZ-24 Ferrite Clamp

Screening effectiveness measurement The screening effectiveness of a cable is defined as the ratio of the disturbance power of the surface acoustic wave of an unshielded cable measured with the MDS clamp to the disturbance power of the surface acoustic wave on the cable screen. The shielded cable is terminated into its nominal impedance. Disturbing effects caused by standing waves are reduced by the ferrite absorber of the MDS clamp and by an additional ferrite absorber. Relevant standards on screening effectiveness measurements such as DIN 47250 Part 6, IEC 96-1 Amendment 2, and EN 50083-2 slightly differ from each other. Design The MDS clamp consists of a number of ferrite ring cores arranged in a row that surround the cable of the EUT. Some of these ring cores are part of the current transformer. The output voltage of this current transformer is taken to the measuring receiver via an internal RF cable also loaded by ferrite rings. With power cables, the measurement result is not affected by the magnitude of the current, since the currents of the forward and return leads cancel each other out. MDS clamps consist of a two-part plastic case that can be opened. Each part includes a set of ferrite ring core halves. The halves are arranged in spring-loaded holding devices to form a channel to surround the cable of the EUT to be inserted. By closing the upper part of the plastic case, the magnetic loop around the cable is completed. Practical eccentric catches provide the necessary contact pressure. To determine disturbance maxima, the clamp has ball bearing rollers rated for continuous use that is typical of automatic measurements. EZ-24 ferrite clamp The absorber material characteristics of the EZ-24 ferrite clamp correspond to those of the MDS-21 absorbing clamp. In a 50 W circuit, the clamp produces decoupling attenuation of more than 15 db in the range from 30 MHz to 1000 MHz. The ferrite clamp can be opened to insert the cable to be loaded. Test procedure To measure the disturbance power of an EUT, the EUT is put on a non-conductive surface (test table) so that it is at least 40 cm away from a conductive floor or wall. The cable is to be extended to l/2 + 60 cm depending on the lowest disturbance frequency (30 MHz) to be measured. The cable is inserted horizontally so that the absorbing clamp surrounding the cable can be easily slid along the cable. The current transformer faces the EUT. Test setup for disturbance power measurements The following example describes the test procedure (see figure on page 4). The EUT is first switched on and the measuring receiver is set to a frequency of the disturbance spectrum. The MDS clamp is then slid away from the disturbance source until the maximum is displayed on the measuring receiver. The operator should hold the MDS clamp at the end away from the EUT or slide the clamp along the cable by means of a traction line. Correction in db 5 4 3 2 1 0 50 system Measured Voltage power dbpw = readout dbµv + Correction db 21 19 17 Insertion loss in db Usually, the maximum near the disturbance source is measured. In the case of frequencies above 150 MHz, the maximum may occur in the handle of the EUT. If this is the case, the clamp must be slid along the cable to obtain the second maximum (distance L 2 ) provided that this yields a higher value than that with the MDS clamp slid close to the EUT. The disturbance level is now displayed at the measuring receiver. 1 2 15 3 4 13 5 30 100 1000 Frequency in MHz Characteristic calibration curve of an MDS-21 absorbing clamp MDS-21 Absorbing Clamp, EZ-24 Ferrite Clamp 3

L 1 L 2 1 3 6 4 2 5 f min 30 MHz 40 MHz 50 MHz L 1min 5.5 m 4.2 m 3.5 m 1 EUT 2 Power cable 3 Power plug/socket 4 MDS clamp 5 Measuring receiver 6 Ferrite clamp Test setup for measuring the disturbance power The following applies to readout in dbµv: disturbance power/dbpw = reading/dbµv + correction value/db Advanced measuring receivers allow a transducer factor to be entered. MDS absorbing clamp slideways are to be used to perform automatic measurements. Further applications In addition to measuring the disturbance emitted from small appliances and measuring the screening effectiveness of cable screens, the MDS 21 absorbing clamp can also be used for measuring the efficiency of disturbance suppression devices for high-voltage ignition systems in accordance with CISPR 12 or EN 55012. High-energy pulses are then coupled out and taken to the measuring receiver. This means that measuring receiver inputs must be thoroughly protected. The MDS clamps are also suitable for use as coupling clamps in order to test the immunity of electronic devices. 0 50 system Decoupling attenuation in db 10 20 30 40 50 60 70 80 1 10 100 1000 Frequency in MHz Characteristic decoupling attenuation of the EZ-24 ferrite clamp MDS-21 Absorbing Clamp, EZ-24 Ferrite Clamp 4

Compact, cost-efficient test set consisting of the ESCI EMI test receiver and the MDS 21 absorbing clamp for semiautomatic measurement of the disturbance power Specifications Ordering information Frequency range Typical insertion loss in accordance with CISPR 16-1-3 (individual calibration certificate supplied with clamp) Receiver input impedance Connector Permissible DC current or peak value of AC current Maximum permissible RF input power for susceptibility measurement Maximum cable diameter Supplied spacer (diameter) Rollers Overall dimensions (W H D) Weight MDS-21 30 MHz to 1000 MHz 17 db ± 4 db 50 W N female, 50 W 30 A 5 W 20 mm 10 mm ball bearing, dust-protected 610 mm 115 mm 80 mm (24.9 in 4.5 in 3.1 in) 6.3 kg (13.9 lb) Designation Type Order No. Absorbing Clamp MDS-21 0194.0100.50 Accessories supplied 1 coaxial connecting cable (for connecting the MDS-21 to the EMI measuring receiver), 5 m long with 2 N male; 6 db attenuator with 2 N female, elbow adapter Ferrite Clamp EZ-24 1107.2535.02 Frequency range Decoupling attenuation in the range from 30 MHz to 1000 MHz in 50 W circuit Maximum permissible skin current RF power Overall dimensions (W H D) Weight EZ-24 1 MHz to 1000 MHz >15 db (see typ. curve) 50 W 626 mm 57 mm 80 mm (24.6 in 2.2 in 3.1 in) 3.5 kg (7.7 lb) MDS-21 Absorbing Clamp, EZ-24 Ferrite Clamp 5

Certified Quality System ISO 9001 DQS REG. NO 1954 QM Certified Environmental System ISO 14001 DQS REG. NO 1954 UM More information at www.rohde-schwarz.com (search term: MDS-21, EZ-24) is a registered trademark of Rohde & Schwarz GmbH & Co. KG Trade names are trademarks of the owners Printed in Germany (ch) PD 5213.7919.32 Version 06.00 July 2007 MDS-21, EZ-24 Data without tolerance limits is not binding Subject to change www.rohde-schwarz.com Europe: +49 1805 12 4242, customersupport@rohde-schwarz.com USA and Canada: +1-888-837-8772, customer.support@rsa.rohde-schwarz.com Asia: +65 65 130 488, customersupport.asia@rohde-schwarz.com