Cascaded Two Level Electrical Converter-Based Multilevel STATCOM for High Power Utilization

Similar documents
International Journal of Advance Engineering and Research Development CASCADED MULTILEVEL INVERTER BASED UNIFIED POWER FLOW CONTROLLER

SSRG International Journal of Electrical and Electronics Engineering ( SSRG IJEEE ) Volume 3 Issue 1 January 2016

Cascaded Two-Level Inverter using Fuzzy logic Based multilevel STATCOM for High Power Applications

SERIES AND SHUNT COMPENSATION IN UPFC USING CASCADED MULTILEVEL INVERTER- A TRANSFORMERLESS APPROACH

Power Quality Improvement Using Cascaded Multilevel Statcom with Dc Voltage Control

Power Quality Improvement Using Cascaded Multilevel Statcom with Dc Voltage Control

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

ANALYSIS OF SYNCHRONOUS-REFERENCE-FRAME-BASED CONTROL METHOD FOR UPQC UNDER UNBALANCED AND DISTORTED LOAD CONDITIONS Salava Nagaraju* 1

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Power Quality Improvement Using Hybrid Power Filter Based On Dual Instantaneous Reactive Power Theory With Hysteresis Current Controller

A New Control Scheme for Power Quality Improvement with STATCOM

Ripple Reduction Using Seven-Level Shunt Active Power Filter for High-Power Drives

MMC based D-STATCOM for Different Loading Conditions

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

Power-Quality Improvement with a Voltage-Controlled DSTATCOM

Modified Three-Phase Four-Wire UPQC Topology with Reduced DC-Link Voltage Rating

A SPWM CONTROLLED THREE-PHASE UPS FOR NONLINEAR LOADS

Power Quality Improvement By Using DSTATCOM Controller

TRANSFORMER LESS H6-BRIDGE CASCADED STATCOM WITH STAR CONFIGURATION FOR REAL AND REACTIVE POWER COMPENSATION

Power Quality Improvement of Unified Power Quality Conditioner Using Reference Signal Generation Method

MODELLING AND SIMULATION OF DIODE CLAMP MULTILEVEL INVERTER FED THREE PHASE INDUCTION MOTOR FOR CMV ANALYSIS USING FILTER

Size Selection Of Energy Storing Elements For A Cascade Multilevel Inverter STATCOM

Ripple Reduction Using Seven-Level Shunt Active Power Filter for High-Power Drives and Non- Linear Load System

Fuzzy-Pi Based Direct-Output-Voltage Control Strategy for Statcom Used In Utility Distribution System

I. INTRODUCTION ISSN: EDIGA MADHU BABU 1, MD.FIROZ ALI 2

A Novel Cascaded Multilevel Inverter Using A Single DC Source

Enhancement of Power Quality using active power filter in a Medium-Voltage Distribution Network switching loads

ISSN Vol.03,Issue.11, December-2015, Pages:

Bhavin Gondaliya 1st Head, Electrical Engineering Department Dr. Subhash Technical Campus, Junagadh, Gujarat (India)

Adaptive ANN based STATCOM and DVR for optimal integration of wind energy with grid using permanent magnet synchronous generator

Available online at ScienceDirect. Procedia Technology 21 (2015 ) SMART GRID Technologies, August 6-8, 2015

The unified power quality conditioner: the integration of series and shunt-active filters

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

Intelligence Controller for STATCOM Using Cascaded Multilevel Inverter

Designing Of Distributed Power-Flow Controller

SIMULATION OF D-Q CONTROL SYSTEM FOR A UNIFIED POWER FLOW CONTROLLER

Performance of Indirectly Controlled STATCOM with IEEE 30-bus System

Mitigation of Voltage Sag/Swell by Using Battery Energy Storage DVR for Induction Motor Drive Applications

Simulation of D-STATCOM for Power Quality Improvement With Fuzzy Based Phase Locked Loop Control Strategy

INTERLINE UNIFIED POWER QUALITY CONDITIONER: DESIGN AND SIMULATION

Improvement Voltage Sag And Swell Under Various Abnormal Condition Using Series Compensation

Power Quality enhancement of a distribution line with DSTATCOM

Investigation of negative sequence injection capability in H-bridge Multilevel STATCOM

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

MLI HYBRID STATCOM WITH WIDE COMPENSATION RANGE AND LOW DC LINK VOLTAGE

A THREE PHASE SHUNT ACTIVE POWER FILTER FOR HARMONICS REDUCTION

IMPROVEMENT OF POWER QUALITY USING CUSTOM POWER DEVICES

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

IJSTE - International Journal of Science Technology & Engineering Volume 2 Issue 12 June 2016 ISSN (online): X

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Simulation of Multi Converter Unified Power Quality Conditioner for Two Feeder Distribution System

Design of STATCOM for unbalanced Voltage Systems with Adaptive multilevel converter (AMC)

Simulation Study of PWM Techniques for Voltage Source Converters

Phase Shift Modulation of a Single Dc Source Cascaded H-Bridge Multilevel Inverter for Capacitor Voltage Regulation with Equal Power Distribution

OVERVIEW OF SVC AND STATCOM FOR INSTANTANEOUS POWER CONTROL AND POWER FACTOR IMPROVEMENT

Comparison of Three leg and Four Leg VSC DSTATCOM for Power Quality Assessment

Stability Enhancement for Transmission Lines using Static Synchronous Series Compensator

A Five Level DSTATCOM for Compensation of Reactive Power and Harmonics

Power Quality improvement of a three phase four wire system using UPQC

A Modified Control Method For A Dual Unified Power Quality Conditioner

Kalman Filter Based Unified Power Quality Conditioner for Output Regulation

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

Investigation of D-Statcom Operation in Electric Distribution System

Power Quality Enhancement of Grid Connected Non-Conventional Energy System using STATCOM with PI Controller

A Voltage Controlled Dstatcom for Power Quality Improvement

A Novel Approach to Simultaneous Voltage Sag/Swell and Load Reactive Power Compensations Using UPQC

ISSN: [Yadav* et al., 6(5): May, 2017] Impact Factor: 4.116

Development and Simulation of Dynamic Voltage Restorer for Voltage SAG Mitigation using Matrix Converter

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

REDUCTION OF THD IN POWER SYSTEMS USING STATCOM

Simulation and Comparison of DVR and DSTATCOM Used For Voltage Sag Mitigation at Distribution Side

PSPWM Control Strategy and SRF Method of Cascaded H-Bridge MLI based DSTATCOM for Enhancement of Power Quality

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

Downloaded from

Harmonic Immunity And Power Factor Correction By Instantaneous Power Control Of D-STATCOM

Enhanced Performance of Multilevel Inverter Fed Induction Motor Drive

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

VSC Based HVDC Active Power Controller to Damp out Resonance Oscillation in Turbine Generator System

ISSN Vol.04,Issue.08, July-2016, Pages:

Multi level DVR with Energy Storage System for Power Quality Improvement

Enhancement of Power Quality with Multifunctional D-STATCOM Operated under Stiff Source for Induction Motor Applications

PI-VPI Based Current Control Strategy to Improve the Performance of Shunt Active Power Filter

Compare Stability Management in Power System Using 48- Pulse Inverter, D-STATCOM and Space Vector Modulation Based STATCOM

Multilevel Converter for Ac Dc Harmonic Immunity in VSC Hvdc Transmission

A NOVEL APPROACH TO ENHANCE THE POWER QUALITY USING CMLI BASED CUSTOM POWER DEVICES

MODELING AND ANALYSIS OF IMPEDANCE NETWORK VOLTAGE SOURCE CONVERTER FED TO INDUSTRIAL DRIVES

Modeling and Simulation of SRF and P-Q based Control DSTATCOM

Feed-Forward System Control for Solid- State Transformer in DFIG

Three Phase Parallel Multilevel Inverter Fed Induction Motor Using POD Modulation Scheme

HYSTERESIS CONTROL FOR CURRENT HARMONICS SUPPRESSION USING SHUNT ACTIVE FILTER. Rajesh Kr. Ahuja

2020 P a g e. Figure.2: Line diagram of series active power filter.

Novel Technique For The Reduction in Wind Power Generation

ICCCES Application of D-STATCOM for load compensation with non-stiff sources

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

HYBRID ACTIVE FILTER WITH VARIABLE CONDUCTANCE FOR HARMONIC RESONANCE SUPPRESSION USING ANN

Mitigation of Flicker Sources & Power Quality Improvement by Using Cascaded Multi-Level Converter Based DSTATCOM

ISSN Vol.07,Issue.21, December-2015, Pages:

A Hybrid Cascaded Multilevel Inverter for Interfacing with Renewable Energy Resources

Key terms: Voltage, Phase Angle, FACTS, Multilevel Converter, Power Quality, STATCOM.

ISSN Vol.02,Issue.19, December-2013, Pages:

Transcription:

Cascaded Two Level Electrical Converter-Based Multilevel STATCOM for High Power Utilization D.Nagaraju M.Tech-PE, Vidya Bharathi Institute of Technology, T.S, India. L.Ramesh Associate Professor, Vidya Bharathi Institute of Technology, T.S, India. Abstract: In this project, a simple static var compensating scheme using a cascaded two-level inverter-based multilevel inverter is proposed. The topology consists of two standard two-level inverters connected in cascade through open-end windings of a three-phase transformer. The dc-link voltages of the inverters are regulated at different levels to obtain four-level operation. The simulation study is carried out in MATLAB/SIMULINK to predict the performance of the proposed scheme under balanced and unbalanced supply-voltage conditions. A laboratory prototype is developed to validate the simulation results. The control scheme is implemented using the TMS320F28335 digital signal processor. Further, stability behavior of the topology is investigated. The dynamic model is developed and transfer functions are derived. The system behavior is analyzed for various operating conditions. Introduction: There has been an extensive growth and quick development in the exploitation of wind energy in recent years. The individual units can be of large capacity up to 2 MW, feeding into distribution network, particularly with customers connected in close proximity. Today, more than 28,000 wind generating turbines are successfully operating all over the world. In the fixed-speed wind turbine operation, all the fluctuation in the wind speed are transmitted as fluctuations in the mechanical torque, electrical power on the grid and leads to large voltage fluctuations. During the normal operation, wind turbine produces a continuous variable output power. These power variations are mainly caused by the effect of turbulence, wind shear, and tower-shadow and of control system in the power system. Problem Definition: Thus, the network needs to manage for such fluctuations. The power quality issues can be viewed with respect to the wind generation, transmission and distribution network, such as voltage sag, swells, flickers, harmonics etc. However the wind generator introduces disturbances into the distribution network. One of the simple methods of running a wind generating system is to use the induction generator connected directly to the grid system. The induction generator has inherent advantages of cost effectiveness and robustness. However; induction generators require reactive power for magnetization. System Operation: The shunt connected STATCOM with battery energy storage is connected with the interface of the induction generator and non-linear load at the PCC in the grid system. The STATCOM compensator output is varied according to the controlled strategy, so as to maintain the power quality norms in the grid system. The current control strategy is included in the control scheme that defines the functional operation of the STATCOM compensator in the power system. A single STATCOM using insulated gate bipolar transistor is proposed to have a reactive power support, to the induction generator and to the nonlinear load in the grid system. The main block diagram of the system operational scheme is shown in Fig. 3.2. Page 1489

Fig 1: system operational scheme in grid system Control scheme: The control scheme approach is based on injecting the currents into the grid using bang-bang controller. The controller uses a hysteresis current controlled technique. Using such technique, the controller keeps the control system variable between boundaries of hysteresis area and gives correct switching signals for STATCOM operation. Fig 2: Control system scheme Cascaded two-level inverter-based Multilevel STATCOM: Fig.3 shows the power system model considered in this Fig. 2 shows the circuit topology of the cascaded two-level inverter-based multilevel STATCOM using standard two-level inverters. Fig 4: Cascaded two-level inverter-based multilevel STATCOM Fig 5: Equivalent circuit of the cascaded two-level inverter-based multilevel STATCOM. Control Strategy: The control block diagram is shown in Fig. 6. The unit signals and are generated from the phase-locked loop (PLL) using three-phase supply voltages [14]. The converter currents (( )) are transformed to the synchronous rotating reference frame using the unit signals. The switching frequency ripple in the converter current components is eliminated using a low-pass filter (LPF). From and loops, the controller generatesd q axes reference voltages, and for the cascaded inverter. With these reference voltages, the inverter supplies the desired reactive current ( ) and draws required active current ( ) regulate total dclink voltage( ). However, this will not ensure that individual dc-link voltages are controlled at their respective reference values. Hence, additional control is required to regulate individual dc-link voltages of the inverters. Fig.3: Power system and the STATCOM model. Page 1490

voltages of two inverters. The dc-link voltages are maintained at their respective reference values when the operating conditions are changed. Fig 6: Control block diagram Reactive Power Control: In this case, reactive power is directly injected into the grid by setting the reference reactive current component at a particular value. Initially, is set at 0.5 p.u. At t= 2.0 s, is changed to 0.5 p.u. Fig. 7(a) shows the source voltage and converter current of the phase. Fig. 7(b) shows the dc-link voltages of two inverters. From the figure, it can be seen that the dc-link voltages of the inverters are regulated at their respective. Fig 7: Reactive power control. (a) Source voltage and inverter current (b) DC-link voltages of two inverters: Reference values when the STAT Commode is changed from capacitive to inductive. Moreover, the dc-link voltage of inverter 2 attains its reference value faster compared to that of inverter 1 as discussed in Section II. Load Compensation: In this case, the STATCOM compensates the reactive power of the load. Initially, STATCOM is supplying a current of 0.5 p.u. At t= 2.0 s, the load current is increased so that STATCOM supplies its rated current of 1 p.u. Fig. 8(a) shows source voltage and converter current, while Fig. 8(b) shows the dc-link Fig 8: Load compensation. (a) Source voltage and inverter current. (b) DC-link voltages of two inverters Operation during the Fault Condition In this case, a single-phase-to-ground fault is created at t=1.2 s, on the phase of the HV side of the 33/11- kvtransformer.the fault is cleared after 200 ms. Fig. 9(a) shows voltages across the LV side of the 33/11- kv transformer. Fig. 9(b) and (c) shows the - axes components of negative-sequence current of the converter. These currents are regulated at zero during the fault condition. Fig 9: Operation during fault. (a) Grid voltages on the LV side of the transformer.(b) -axis negativesequence current component. (c) -axis negativesequence current component. Page 1491

SIMULATION RESULTS STATCOM Reactive OUTPUTS: Fig 10:statcom reactive Fig 16: source output at fault condition OUT PUTS Fig 17:stat com output at faultcondition Fig.11:Source output at reactive condition Fig12:statcom output at reactive condition Fig 18:vdc2 output at fault condition Fig 13:vdc2 output at reactive condition Fig19: vdc3 at fault condition 5.3STATCOM load com Fig14: vdc3 output at reactive condition STATCOM fault Fig 20: stat com load com Fig 15:statcom fault Page 1492

OUTPUT: Fig 21: source output at load com Fig 22: stat com output at load com Fig 23:vdc2 output at load com Fig24: vdc3 output at load com CONCLUSION: The paper presents the STATCOM-based control scheme for power quality improvement in grid connected wind generating system and with non linear load. The power quality issues and its consequences on the consumer and electric utility are presented. The operation of the control system developed for the STATCOM-BESS in MATLAB/SIMULINK for maintaining the power quality is simulated. It has a capability to cancel out the harmonic parts of the load current. It maintains the source voltage and current in-phase and support the reactive power demand for the wind generator and load at PCC in the grid system, thus it gives an opportunity to enhance the utilization factor of transmission line. The integrated wind generation and STATCOM with BESS have shown the outstanding performance. Thus the proposed scheme in the grid connected system fulfills the power quality norms as per the IEC standard 61400-21. Future Enhancement: Simple static var compensating scheme using a cascaded two-level inverter-based multilevel inverter is proposed. The topology consists of two standard two-level inverters connected in cascade through open-end windings of a three-phase transformer. The dc-link voltages of the inverters are regulated at different levels to obtain four-level operation. The simulation study is carried out in MATLAB/SIMULINK to predict the performance of the proposed scheme under balanced and unbalanced supply-voltage conditions. A laboratory prototype is developed to validate the simulation results. The control scheme is implemented using the TMS320F28335 digital signal processor. Further, stability behavior of the topology is investigated. The dynamic model is developed and transfer functions are derived. The system behavior is analyzed for various operating conditions. REFERENCES: [1] N. G. Hingorani and L. Gyugyi, Understanding FACTS. Delhi, India: IEEE, 2001, Standard publishers distributors. Page 1493

[2] B. Singh, R. Saha, A. Chandra, and K. Al-Haddad, Static synchronous compensators (STATCOM): A review, IET Power Electron., vol. 2, no. 4, pp. 297 324, 2009. [3] H. Akagi, H. Fujita, S. Yonetani, and Y. Kondo, A 6.6-kV transformer less STATCOM based on a five-level diode-clamped PWM converter: System design and experimentation of a 200-V 10-kVA laboratory model, IEEE Trans. Ind. Appl., vol. 44, no. 2, pp. 672 680, Mar./Apr. 2008. [4] A. Shukla, A. Ghosh, and A. Joshi, Hysteresis current control operation of flying capacitor multilevel inverter and its application in shunt compensation of distribution systems, IEEE Trans. Power Del., vol. 22, no. 1, pp. 396 405, Jan. 2007. [5] H. Akagi, S. Inoue, and T. Yoshii, Control and performance of a transformerless cascaded PWM STATCOM with star configuration, IEEETrans. Ind. Appl., vol. 43, no. 4, pp. 1041 1049, Jul./Aug. 2007. [6] Y. Liu, A. Q. Huang, W. Song, S. Bhattacharya, and G. Tan, Smallsignal model-based control strategy for balancing individual dc capacitor voltages in cascade multilevel inverter-based STATCOM, IEEE Trans. Ind. Electron., vol. 56, no. 6, pp. 2259 2269, Jun. 2009. [7] H. P.Mohammadi and M.T.Bina, A transformer less medium-voltage STATCOM topology based on extended modular multilevel converters, IEEE Trans. Power Electron., vol. 26, no. 5, pp. 1534 1545, May 2011. [8] X. Kou, K. A. Corzine, and M. W. Wielebski, Overdistention operation of cascaded multilevel inverters, IEEE Trans. Ind. Appl., vol. 42, no. 3, pp. 817 824, May/Jun. 2006. [9] K. K. Mohaptra, K. Gopakumar, and V. T. Somasekhar, A harmonic elimination and suppression scheme for an open-end winding induction motor drive, IEEE Trans. Ind. Electron., vol. 50, no. 6, pp. 1187 1198, Dec. 2003. [10] Y. Kawabata, N. Yahata,M. Horii, E. Egiogu, and T. Kawabata, SVG using open winding transformer and two inverters, in Proc., 35th AnnualIEEE Power Electron. Specialists Conf., 2004, pp. 3039 3044. [11] S. Ponnaluri, J. K. Steinke, P. Steimer, S. Reichert, and B. Buchmann, Design comparison and control of medum voltage STATCOM with novel twin converter topology, in Proc., 35th Annu. IEEE Power Electron.Specialists Conf., 2004, pp. 2546 2550. [12] N. N. V. Surendra Babu, D. Apparao, and B. G. Fernandes, Asymmetrical dc link voltage balance of a cascaded two level inverter based STATCOM, in Proc., IEEE TENCON, 2010, pp. 483 488. [13] IEEE Criteria for Class IE Electric Systems, IEEE Standard 141-1993. [14] C. Schauder and H. Mehta, Vector analysis and control of advanced static VAr compensators, in Proc. Inst. Elect. Eng. C., Jul. 1993, vol. 140, no. 4, pp. 299 305. [15] D. G. Holmes and T. A. Lipo, IEEE series on power engineering, in Pulse Width Modulation for Power Converters: Principles and Practice. Piscataway, NJ, USA: IEEE, 2003. [16] B. Blazic and I. Papic, Improved D-statcom control for operation with unbalanced currents and voltages, IEEE Trans. Power Del., vol. 21, no. 1, pp. 225 233, Jan. 2006. Page 1494