Technical Bulletin, Communicating with Honeywell TM ST3000/STT3000 Smart Transmitters

Similar documents
815LT Submersible Smart Level Transmitter

MI June Instruction. I/A Series Intelligent Pressure Transmitters. Operation, Configuration, and Calibration Using a HART Communicator

815PT Smart Pressure Transmitter

BMS BMU Vehicle Communications Protocol

Calibration Instruction Manual Emerson 475 Field Communicator. Manual Revision FC.2

Micro Motion Model 1700 Transmitters with Analog Outputs 1700***A. Configuration and Use Manual Supplement. Configuration Operation Maintenance

TS16 - Pre-Instructional Survey

User Configurable POSITION 303 DATA OUTPUT 450 HEADING 910

Multi-Variable Analog Interface for Smart Transmitters Specifications

STT Series STT250 Smart Temperature Transmitter

HART Mode. Users Guide. July Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies.

Rosemount 333 HART Tri-Loop

BusWorks 900EN Series Modbus TCP/IP 10/100M Industrial Ethernet I/O Modules

Micro Motion Model 2700 Transmitters with Configurable Input/Outputs 2700***B 2700***C. Configuration and Use Manual Supplement

Global Navigation Satellite System for IE 5000

Instruction Manual ABM HART Gateway Software. Instruction Manual Revision A.1

Universal Controller

Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 4.00 and greater

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use

SmartLine Multivariable Transmitter SMV800 Quick Start Installation Guide

SFC Smart Field Communicator Model STS103. Specification 34-ST /24/06. Description. Function. Page 1 of 5

PROPRIETARY CAN COMMUNICATION DOCUMENT. Proprietary CAN Communication for the PCS Automatic Transmission Controller

The wireless alternative to expensive cabling...

EE 314 Spring 2003 Microprocessor Systems

ROTRONIC HygroClip Digital Input / Output

GE Fanuc IC695ALG600. Rx3i PacSystem

TEK-TROL HART GATEWAY SOFTWARE. Operating Instruction Manual.

Modulating control valve

Instruction Sheet UPS SERIES. Serial Control Protocol. I Rev E

MADEinUSA OPERATOR S MANUAL. RS232 Interface Rev. A

HD Radio FM Transmission System Specifications

FLXA402 4-Wire Converter HART Communication. FLEXA, FLXA, SENCOM and FieldMate are registered trademarks of Yokogawa Electric Corporation.

InsuLogix T MODBUS Protocol Manual

UNIVERSAL PNEUMATIC TRANSDUCER FEATURES

medlab Two Channel Invasive Blood Pressure OEM board EG 02000

STT850 SmartLine Temperature Transmitter Quick Start Guide

GE Fanuc IC695ALG312. Rx3i PacSystem

Product Specification for model TT Transducer Tester Rev. B

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

NWS300 Field Type Smart Meter

ADAM-4022T Serial Base Dual Loops PID Controller User s Manual

The wireless alternative to expensive cabling...

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

Instruction Manual TRICOR TCE HART Communication TCM COHA_S_EN_161220_E002

The wireless alternative to expensive cabling...

TI25 - Pre-Instructional Survey

Intelligent Communicator DCR3000

RTT20 I/A Series Temperature Transmitter

WWVB Receiver/Decoder With Serial BCD or ASCII Interface DESCRIPTION FEATURES APPLICATIONS

Home Automation, Inc. Omnistat2. RC-1000 and RC-2000 Communicating Thermostat. Serial Protocol Description

Photoelectric Sensors. Manual. True-Color-Sensor with IO-Link. Document number: E Edition C15 Subject to changes.

Accessories for EST4 Series

Digital Panel Meter Glossary

ROC800-Series HART Module

Interface Description

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

Software User Manual

AirChip3000. Description and Main Functions

Line-to-line RMS Volts, 3 phases 4 digits (XXX.X) Volts

SYSTEM SENSOR WIRELESS REPEATER PRODUCT SPECIFICATION

Modbus communication module for TCX2: AEX-MOD

Interface Description

STT700 SmartLine Temperature Transmitter User s Manual 34-TT Revision 2 February 2018

TECHNICAL DOCUMENT EPC SERVO AMPLIFIER MODULE Part Number L xx EPC. 100 Series (1xx) User Manual

DEVICE CONFIGURATION INSTRUCTIONS

FC Series Signal Conditioners

Model Q46 Modbus Communications Manual

Instruction Manual HAS3xE-IM-SW39 10/2005

INSTRUCTION MANUAL FOR ULTRASONIC/MICROWAVE SENSORS

K3P ENG.qxd 23/10/ Pagina 1

SSI Technologies - Application Note AT-AN1 Acu-Trac Ultrasonic Fluid Level Sensors Product Overview

WWVB Receiver/Decoder Module With Serial BCD Interface DESCRIPTION FEATURES APPLICATIONS

Application Note. Renu Electronics Private Limited. PID Instruction In IEC. Page 1

Addendum SmartPAC Third Party Communications Firmware

IVI STEP TYPES. Contents

LVCSi Continuous Vertical Level Sensor with Integrated Display

MODEL 970 HART PROTOCOL PRESSURE TRANSMITTER INSTALLATION MANUAL

Carbon Dioxide (Tiny CO2) Gas Sensor. Rev TG400 User Manual

Enhanced SmartDrive40 MDS40B

I-7088, I-7088D, M-7088 and M-7088D User Manual

CAST Application User Guide

HI 2204LT Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL

PROPRIETARY CAN COMMUNICATION DOCUMENT. Proprietary CAN Communication for the PCS Automatic Transmission Controller

AUTOMATION. Operator s Manual. IRU-2xx4/3xx4 Series. Rev. A2, 11/08 Doc

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

FOD Transmitter User s Guide

WSC-1000 TM WELD SEQUENCE CONTROLLER. Operation / Installation Manual. Computer Weld Technology, Inc.

DeviceNet for Penning Gauges

This Errata Sheet contains corrections or changes made after the publication of this manual.

PACSystems* RX3i. Isolated RTD Input Module, 8 Channels, IC695ALG508-CA. Module Features. GFK-2501C November 2012

Kongsberg Seatex AS Pirsenteret N-7462 Trondheim Norway POSITION 303 VELOCITY 900 HEADING 910 ATTITUDE 413 HEAVE 888

METEOROLOGICAL INSTRUMENTS

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

USING RS-232 to RS-485 CONVERTERS (With RS-232, RS-422 and RS-485 devices)

JPQ2 PULSE ACCUMULATOR

DC1010/DC1020/DC1030/DC1040

DP2500 DP0100 DP0250 Differential Pressure Transmitter

ETHERNET TESTING SERVICES

Analog Module D1-15P User Manual

Liquid Level Transmitter Model MC420 Analog Output

Transcription:

Last Updated: 10-March-2009 TB-960704B Technical Bulletin, Communicating with Honeywell TM ST3000/STT3000 Smart Transmitters OMNI FLOW COMPUTERS, INC. 12620 West Airport Boulevard, Suite 100 Sugar Land, Texas 77478 United States of America Phone-281.240.6161 Fax: 281.240.6162 www.omniflow.com 52-0003-0001/Rev B Page 1 of 7

NOTE: User Manual Reference - This Technical Bulletin complements the information contained in the User Manual and is applicable to all firmware revisions. This Technical Bulletin was previously published as an appendix to user manuals of firmware revisions Version.70 and earlier. Communication with Honeywell TM This feature allows you to communicate with Honeywell Smart Temperature and Pressure Transmitters, via OMNI s H type Process I/O Combo Module and using Honeywell s DE Protocol. Table of Contents Scope...3 Abstract...3 Digitally Enhanced (DE) Protocol Overview...3 Transmitter Database...3 Using the Honeywell Handheld Communicator...3 Combo Module LED Status Indicators...4 Switching Between Analog and Digital Mode...4 Auto Mode...4 Manual Operation...4 Viewing the Status of the Honeywell Transmitter from the OMNI Front Panel...4 52-0003-0001/Rev B Page 2 of 7

Scope All firmware revisions of OMNI 6000/OMNI 3000 Flow Computers have the feature of communicating with Honeywell ST3000 Smart Transmitters. This feature uses Honeywell s Digitally Enhanced (DE) Protocol and requires that an H Combo I/O Module be installed in your flow computer. Abstract Using 'H' Combo I/O Modules, the OMNI Flow Computer can communicate with Honeywell Smart Temperature and Pressure Transmitters using Honeywell s DE Protocol. Up to four (4) transmitters can be connected to each 'H' Type Combo Module, with loop power being provided by the combo module. Digitally Enhanced (DE) Protocol Overview Digital data is transmitted serially between the flow computer and Honeywell Smart Transmitters by modulating the current in the two wire loop connecting the devices. Power for the transmitter is also taken from this current loop. Data is transmitted at 218.47 bits per second with a digital '0' = 20 ma and a digital '1 = 4 ma. In normal operation, the Honeywell transmitter operates in the 6-byte Broadcast Mode'. In this mode, the transmitter transmits the following data to the flow computer every 366 msec: Byte #1 Byte #2-#4 Byte #5 Byte #6 Status Flags Process Variables % Span Value (3-byte floating point) Database ID (indicates where in the transmitter s database Byte #6 below belongs) Database Data Value Transmitter Database By using the data contained in Bytes #5 and #6, the flow computer builds and maintains an exact copy of the smart transmitters configuration database. A transmitter database varies in size from about 90 bytes for a pressure transmitter to 120 bytes for a temperature transmitter. It takes between 30 and 45 seconds to completely build a copy of the transmitter database within the flow computer. The transmitter database is continuously compared against the flow computer configuration settings for that transmitter. The flow computer automatically corrects any differences between the databases by writing the correct configuration data to the transmitter. Using the Honeywell Handheld Communicator The flow computer is responsible for configuring entries within the transmitter. 1) Lower Range Value (LRV) or Zero 2) Transmitter Span or Upper Range Limit (URL) 3) Damping Factor 4) Tag Name Any changes made to one (1), two (2) and three (3) using the handheld communicator will be overwritten by the flow computer. In the digital mode it is not necessary to calibrate the transmitter output using the handheld communicator. The digital signal can be calibrated using the normal OMNI analog input method described in Chapter 8 of Volume 1. 52-0003-0001/Rev B Page 3 of 7

Combo Module LED Status Indicators Each I/O channel of the 'H' Combo module has a set of two (2) LED indicators, one (1) green and one (1) red. The green LED shows all communication activity taking place on the channel (flow computer, transmitter and handheld communicator if connected). The Red LED lights only when the flow computer is transmitting data to the transmitter. Normal digital operation is indicated by a regular pulsation of the green LED (about 3 per second). The red LED will be seen to blink whenever a configuration change is made in the flow computer which affects that particular transmitter. Switching Between Analog and Digital Mode Auto Mode Connecting an analog mode Honeywell smart transmitter to the computer will cause the flow computer to automatically switch the transmitter to the digital DE mode, sending out a communication request to the Honeywell transmitter. A switch over to the digital mode by the transmitter will cause the green LED on the H combo module to pulse steadily indicating that communications have been established. Manual Operation For manual operation, do the following: Disable communications between the Honeywell transmitter and the flow computer by deleting all I/O point assignments within the flow computer to that I/O point. Using the Honeywell SFC, SCT or any Honeywell handheld communicator, press [Shift] [A/D] and wait till the handheld displays 'Change to Analog?' Answer (Yes) by pressing [Enter]. SFC Working will be displayed. The 'H' Combo module s green LED on that channel will stop pulsing. Re-enter the I/O point to cause the OMNI to send the communication request command to the Honeywell and after three (3) commands send, the green LED on the Honeywell module will pulse at a steady 3Hz rate. Viewing the Status of the Honeywell Transmitter from the OMNI Front Panel To verify the data being received from the smart transmitter, press [Input], [Status] and [Enter] from the front panel. The following displays: H1 2 Transmitter PV% 25.00 Status IDLE LRV.0 SPAN 150.0 Damp Sec..00 Conformity bit 0 SW Revision 2.1 Serial # xxxxxxxx Transmitter Type GP URL 3000 ID/TAG PT202 SV.00 H1-2 Transmitter: Indicates the Honeywell Combo Module (H1) and the channel number on that module (Channel 2 in this case). PV%: Process variable value in percentage of the transmitter s span. A -25.00 displayed on the OMNI could mean that the transmitter is not communicating (refer to Status). 52-0003-0001/Rev B Page 4 of 7

Status: There are five status states. 1) OK: Communications between the flow computer and smart Honeywell transmitter are OK. The database within the transmitter matches the flow computer. 2) Idle: This flow computer I/O point has been assigned to a Honeywell transmitter but is not receiving data from the transmitter. Possible cause is a wiring problem such as reversal of wiring. If you observe the status LEDs you will note that the flow computer attempts to establish communications by sending a wake-up command every ten (10) seconds or so. 3) Bad PV: Communications between the flow computer and smart Honeywell transmitter are OK but the transmitter has determined that a critical error has occurred within the transmitter meaning the value of the process variable cannot be trusted. The flow computer will set the transducer failure alarm and follow the fail code strategy selected by the user for this transducer. 4) DB Error: Communications between the flow computer and smart Honeywell transmitter are OK but the flow Computer has determined that the database within the flow computer does not agree with the database within the transmitter. If you observe the status LEDs you will note that the flow computer attempts to correct the transmitters database by writing the correct data to the transmitter once every 30-45 seconds or so. 5) 4 Byte: The transmitter is operating in the 4-Byte Broadcast Mode. Because the flow computer will not tolerate this mode of operation, this status display should only be displayed momentarily as the flow computer will automatically switch the transmitter into the 6-Byte Broadcast Mode. LRV: Span: Damp Seconds: Conformity Bit: Software Revision: Serial #: Transmitter Type: Lower Range Value of the transmitter in engineering units. Engineering units are degrees Celsius for temperature transmitters, inches of water for differential pressure transmitters, and pounds per square inch for pressure transmitters. The Span of the transmitter in engineering units (the Span is the difference between the lower and upper ranges of the transmitter). Engineering units are degrees Celsius for temperature transmitters, inches of water for differential pressure transmitters, and pounds per square inch for pressure transmitters. The flow computer will display DB Error if the user tries to enter a span of 0% or a span which would exceed the transmitter s upper range limit' (URL). Damping Time of the transmitter output in seconds. Meaningful only with differential pressure transmitters. Conformity Bit 0 = linear output; Conformity Bit 1 = square root output. This bit should always be 0 for smart temperature transmitters. Current Software installed within the smart device. Serial Number of the smart transmitter. Valid transmitter types are: TT DP GP = Temperature Transmitter = Differential Pressure Transmitter = Gauge Pressure Transmitter URL: ID/TAG: Upper Range Limit of the transmitter in engineering units. The transmitter will not accept configuration entries which exceed this value. ASCII string used to identify the transmitter. 52-0003-0001/Rev B Page 5 of 7

SV: Secondary Process Variable Value expressed in C. This represents sensor temperature for pressure transmitters, and junction temperature for temperature transmitters. The flow computer may or may not have a value in this field, depending upon whether the SV is included in the part of the transmitter s database which is sent to the OMNI. 52-0003-0001/Rev B Page 6 of 7

DOCUMENT REVISION HISTORY DOCUMENT INITIAL RELEASE DATE...03-May-2003 REVISION DATE PURPOSE / CHANGE REQUEST A 03-May-2003 Maintained on the Web - Initial release B 10-March-2009 DCR 090079 52-0003-0001/Rev B Page 7 of 7