ZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR

Similar documents
LBPLUS DATA. he new busbar unking system for LIGHTING MANAGEMENT. Range

RCP IP68 RESIN BUSBAR TRUNKING GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE

Use RH covers when starting with a LH feed unit or when reaching the LH board. HIGH RATING

IP68 RCP RESIN BUSBAR TRUNKING FOR POWER DISTRIBUTION POWERED BY SPECIALISTS

BUSBAR TRUNKING SYSTEMS 25A-63A AB-E SERIES. The smartest way of power distribution.

GLS A GLS 15

DRIVIA cabinets LIMOGES Cedex France 1. DESCRIPTION, USE 3. DIMENSIONS 2. RANGE, CAT. NO. EQUIVALENCE TABLE

Multi-conductor Lighting Busbar System A

Busbar Trunking Assembly

MISTRAL SYSTEM IMPACT 2

Powerlink Plus Technical

IBAR (EMEA) LIMITED Castle Mills Aynam Road Kendal Cumbria LA9 7DE UK YEARS+ Established. t. +44 (0) e.

50 YEARS+ A brand of the. IBAR (EMEA) LIMITED Castle Mills Aynam Road Kendal Cumbria LA9 7DE UK

50 YEARS+ HX Range Catalogue. IBAR (EMEA) LIMITED Castle Mills Aynam Road Kendal Cumbria LA9 7DE UK

Measuring current transformers of the W, W series

Busbar and Modular Wiring Systems

OptiLine 45 Floor boxes

5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts

SUPER COMPACT - SCP 6 SUPER COMPACT

Technical features table for miniature circuit-breakers SH 200 Series

GROUP MEGABARRE IMPACT. 800A 5000A Abu Dhabi Edition

Safety switches with slotted hole lever

The series terminals are state of the art based on technical enhancements, changes in power engineering, their applications and properties.

Medium power busbar trunking

Current / residual current and voltage transformers. Current / residual current and voltage transformers

(1,5 modules per pole)

Powered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

Slotted trunking halogen free

SPRING CLAMP TERMINAL

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

Cable Management Solutions with DLP TM

Busway Design The Easy Way. By: IIEE-ABU DHABI CHAPTER

Position switches FM series

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

Pluggable connection describes the method used to connect an external conductor to a PCB, via a terminal connector and header

Section five. Connection systems. Isobar 4 Evo MCB pan assemblies Mulitclip busbar and Polybloc 126. Comb busbars 127

QUINT-PS/ 3AC/24DC/10

Distribution Blocks, Power Blocks, Power Terminals

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

4/2 Introduction. Marshaling Boxes 4/8 8GK1 surface-mounting distribution boards

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

Characteristics 5 TeSys k contactors and reversing contactors

E-STOP relays, safety gate monitors

FM series position switches

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

Series P. Applications

Wanco Electric & Machinery Pte Ltd. Cable Management Systems. Cable Trunking

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

Residual Current Operated Circuit-Breakers (RCCBs)

both pin and sleeve contacts.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Raised Floor system LIMOGES Cedex. Phone : Fax :

Modular equipment. Presentation, standards. Standard contactors TeSys GC

3 - Protection components Circuit-breakers

Your passport to success TECHNICAL OVERVIEW

ET 40 - Electrician Theory Examination Marking Schedule

MINI-PS AC/24DC/1.3

Canalis KS. Contents. Presentation. Description. Catalogue numbers Dimensions. Installation

QUINT-PS/ 3AC/24DC/40

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

T e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker

2/2 Introduction. Unequipped Distribution Boards 2/5 8GK1 surface and flush-mounting distribution boards

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Electronic Circuit Breaker with reset input ESS20-1..

Measuring current transformers of the W B series

Totally Integrated Power SIVACON 8PS LI busbar trunking system siemens.com/li-system

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Junction boxes. Surface mounting - IP44 - IP55 - IP56 TECHNICAL CHARACTERISTICS

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

4.3 Section CONDUIT INSTALLATION ACCESSORIES. Thinking of the environment. Fixing accessories Coupling accessories

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

FreeSpace DS 16SE TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications

Protection components

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

FreeSpace DS 40SE TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications

Datasheet - PROTECT-IE-02

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

Type CP-S, CP-C & CP-A Switch mode

For Immediate Delivery call KMParts.com at (866)

Risk Assessment & Safe Working Practice

FreeSpace DS 16F VA TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications

Electronic Step Controller

PHOENIX CONTACT

LED Driver Constant voltage

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS. Fourth Edition. Extracts from Amendment No.1: June 2011

Measuring current transformers of the W AB(P) series

Flush Floor system LIMOGES Cedex. Phone : Fax :

ATBTK-MF-4G. Product Classification. Mechanical Specifications. Dimensions. Regulatory Compliance/Certifications.

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Technical guide. The technical guide provides all the additional information you need on our cable management products.

8 Input/8 Output AC Block I/O Module

Page 13-2 Page Page 13-7

Datasheet BR & SU Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors

LED Driver Constant voltage

Transcription:

ZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR The flexibility of the Zucchini MS range during planning and installation makes it ideal for frequently changing requirements in small to medium sized commercial and industrial premises. With versions ranging from 63 A to 60 A, the vast selection of elbows, tees and other accessories make any configuration possible, with bespoke solutions also available on request. In addition to the wide range of accessories, a choice of tap-off boxes from 6 to 63 A accommodate protection devices up to 6 DIN modules. To find out more call our technical support team on +44 (0) 370 60 9020 20

MS double sided busbar low and medium power 63/00/60 A End cover 55035 Tap-off box for 4 modules 555074 Suspension bracket 5002002 Right end feed unit (see p. 22) 5505 Trunking length 5500 Tap-off box for modules 555075 Joint cover 55006 Dimensions and technical information p. 24 Technical data p. 27 Conforms to BS EN 60439-2. Casing manufactured from Senzimir quality galvanised steel suitable for use as a protective earth IP 40 as standard, increasing to IP 55 with use of appropriate accessories Pack Cat. Nos. 63 A trunking lengths Pack Cat. Nos. 00 A trunking lengths Tap-off outlets are spaced every 0 m on both sides and are fitted with shutters to prevent accidental contact with live parts Expansion joints are not required Standard lengths Length Outlet (m) points 55300 3 3 + 3 7 90 55306 2 2 + 2 5 260 55305 5 + 3 945 55304 + 2 630 55302 < 5 55303 > 5 Fire barrier Lengths are fitted with a fire barrier and are used to pass through fire-resistant walls In accordance with DIN 402-9 and EN 366-3 Length Outlet (m) points 55303 3 3 + 3 7 990 Thrust unit Thrust unit to be located at the bottom and is required for vertical runs or riser applications exceeding2-5 m Length Outlet (m) points 55304 3 3 + 3 7 90 L N L2 L3 Standard lengths Length Outlet (m) points 5500 3 3 + 3 7 90 5506 2 2 + 2 5 260 5505 5 + 3 945 5504 + 2 630 5502 < 5 5503 > 5 Fire barrier Lengths are fitted with a fire barrier and are used to pass through fire-resistant walls In accordance with DIN 402-9 and EN 366-3 Length Outlet (m) points 5503 3 3 + 3 7 990 Thrust unit Thrust unit to be located at the bottom and is required for vertical runs or riser applications exceeding 2-5 m Length Outlet (m) points 5504 3 3 + 3 7 90 60 A trunking lengths Standard lengths Length Outlet (m) points 55200 3 3 + 3 9 290 55206 2 2 + 2 6 90 55205 5 + 4 645 55204 + 3 00 55202 < 5 55203 > 5 Fire barrier Lengths are fitted with a fire barrier and are used to pass through fire-resistant walls In accordance with DIN 402-9 and EN 366-3 Length Outlet (m) points 55203 3 3 + 3 0 290 Thrust unit Thrust unit to be located at the bottom and is required for vertical runs or riser applications exceeding 2-5 m Length Outlet (m) points 55204 3 3 + 3 9 290 2

MS double sided busbar trunking components 555 550036 550046 Dimensions and technical information p. 24-25 Conforms to BS EN 60439-2. Casing manufactured from Senzimir quality galvanised steel suitable for use as a protective earth IP 40 as standard, increasing to IP 55 with use of appropriate accessories Pack Cat. Nos. Trunking components For changing the route of trunking, either horizontally or vertically Horizontal elbows right hand Right and left elbows differ because of the position of junction blocks 553035 63 550036 00 552035 60 553036 63 5500362 00 552036 60 553045 63 550046 00 552045 60 553046 63 5500462 00 552046 60 553055 63 550056 00 552055 60 6 7 2 7 6 6 2 6 Right hand tees female Right hand tees male 6 6 2 6 Vertical elbows left hand Vertical elbows right hand 6 6 2 6 Horizontal elbows left hand 553057 63 5500563 00 552057 60 Pack Cat. Nos. Trunking components (continued) Left hand tee female 553056 63 5500562 00 552056 60 55305 63 5500564 00 55205 60 Crossovers 553065 63 550066 00 552065 60 Flexible elbow For horizontal and vertical changes of direction up to 90 Not available for 60 A rating 5526 63-00 55226 60 Feed units End feed units IP 55 IP 55 protection as standard. Supplied with cable clamp and terminals for 35 mm (MS 63/00) and 70 mm (MS 60) cables Switched-end feed units are also available with in-line bus switches on request Right 5505 63-00 Left 55052 63-00 Right 55205 60 Left 552052 60 555 63-00 5525 60 Right 732 74 2 2 2 360 Centre feed units IP 55 22 Left hand tee male 3 5 5 0 Left

MS double sided busbar tap-offs and accessories 55505 Tap-offs can be supplied pre-wired and fitted with protective devices Contact us on +44 (0) 45 600 6266 55006 555056 555052 55505 550060 Dimensions and technical information p. 25-26 Tap-off boxes can be used to connect and energise one and three phase loads up to 63 A. Tap-offs can be inserted and removed when the busbar is energised and when the fixture is under load, up to a capacity 32 A. Compliant with IEC 60695-2-0 with V self-extinguishing degree (UL 94) Standard IP 55 degree of protection Pack Cat. Nos. Tap-off boxes IP 55 Pack Cat. Nos. Tap-off boxes with isolating device on the cover Energy withstand 400 0 A S Totally insulated tap-off box size 25 mm2 Tap-off box with CH0 fuseholder (0 3 x 3) Max. power losses 0 W Empty tap-off box with DIN (4 mod.) 3 2 55507 32 0 6 Tap-off box with CH0 fuseholder (0 3 x 3) 555076 32 0 6 Tap-off box with D0 fuseholder 555077 6 0 95 Tap-off box with D02 fuseholder 55507 32 0 95 Tap-off box for (4 mod.) DIN 555072 32 0 73 Max. power losses 6 W Empty tap-off box ( mod) 555073 32 0 93 Tap-off box (4 mod) DIN (long version) 555074 32 0 96 Tap-off box ( mod) DIN (long version) 555075 32 0 99 0 3 x 3 fuses not included 55505 6 0 90 Tap-off box with CH4 fuseholder (4 x 5) 4 x 5 fuses not included 555052 50 0 90 63 A tap-off boxes Energy withstand 400 03 A2S MAX power losses 20W Tap-off box with transparent cover 555057 kg Tap-off box with transparent cover and hinged door (up to 4 mod.) 555056 2 kg Tap-off box with hinged door (up to 7 mod.) 555067 kg Tap-off box with hinged door (up to 6 mod.) Energy withstand 400 03 A2S MAX power losses 20W 55505 2 5 kg Accessories End cover IP 55 End covers are fitted to the last length in each run to maintain IP 55 protection 55035 0 57 kg Joint cover IP 55 One for each joint 55006 0 7 kg Tap-off outlet cover IP 55 6 per 3 m straight length 550060 0 06 kg Suspension bracket Universal fixing brackets enable trunking to be either suspended or wall mounted per 2 m 5002002 0 kg 23

MS double sided busbar technical information n General features n Trunking components MS is fully compliant with IEC EN 6439-6. Specifically, the rated current of the Zucchini busbar trunking system is always referred to the average ambient temperature of 40 C (NB : the standard requires 35 C), thus offering the market suitably oversized products IP 55 (according to BS EN 60529) Horizontal elbow - right hand n Trunking lengths Horizontal elbow - left hand 35 Vertical elbow - right hand Vertical elbow - left hand 35 35 35 The components and the features of the MS trunking lengths are : a casing made of Senzimir quality galvanised steel, with a sheetmetal thickness that allows its use as the protective earth (PE) and ensures the electrical continuity during mounting with no added accessories section bar dimensions : 39 x 97 mm number of conductors : 4 with the same section 3P + N available for capacities 63 A, 00 A and 60 A separation between the conductors using plastic insulating devices, reinforced with 20% of glass fibres, which ensure a V selfextinguishing degree (according to UL94) and are in compliance with the glow-wire test according to IEC 60695-2-0 tap-off outlets with a constant centre distance of m on both sides of the busbar (3 + 3 outlets every 3 m), set up for connection to tap-off boxes an electric joint block, with silver-plated copper contacts for automatically connecting live parts and the PE (protective earth) Quick connection between straight lengths. One operation provides an electrical and mechanical connection, whilst at the same time, IP 40 protection is guaranteed. The upgrade to IP 55 is easily achieved by adding joint covers and outlet covers. Flame retardant in compliance with the IEC 60332-3 standard trunking lengths with fire barrier (internal + external) are used when fire-resistant walls need to be passed through. The lengths fitted with a fire barrier have been lab-tested (in accordance with DIN 402-9 and EN 366-3) in order to confirm that, if correctly installed, they will maintain the essential fire-resistant features of the wall trunking lengths with thrust unit are provided with a device which blocks the conductors from slipping when supporting the weight of the riser (when installed vertically). This type of length is required for 0 m riser intervals 35 Right hand tees - male Right hand tees - female 35 35 97 70 25 L N L2 L3 39 Left hand tees - female Left hand tees - male 35 35 3 000 65 000 000 35 230 230 35 000 000 65 Flexible elbow Crossovers 65 35 26 All dimensions (mm) are nominal 24

n End feed units Installation is carried out with a quick junction connection The feed units have terminals for the connection of copper cables for sections of up to 35 mm 2 for the 63/00 A feed unit and 70 mm 2 for the 60 A feed unit The entrance point of the cables is positioned at the end of the feed unit 63 00 A d = max. Ø 55 60 A 25 5 No. 2 d = max. Ø 63 2 65 273 left 200 273 left right right 0 0 0 0 0 size 70 mm 2 Tap-off boxes Used to connect and energise single phase and three phase loads up to 63 A. Features include : the PE contact (protective earth) is the first to make an electrical connection when inserting the box into the outlet and it is the last to disconnect when removing compliance with all insulating plastic components according to the glow-wire test (IEC 60695-2-0) with V self-extinguishing degree (UL94) standard IP 55 degree of protection without using additional accessories can be inserted and removed when the busbar is energised and when the fixture is under load, up to a capacity of 32 A These boxes are available in a wide range of versions : 63 A empty boxes (only with a terminal board for connecting cables), with an internal DIN rail and transparent door 6 A - available with a set of three cylindrical fuse carriers (0 3 x 3 mm) 6/32 A - available with a set of three cylindrical fuse carriers - DIAZED (D0 : 6 A; D02 : 32 A); 50 A available with cylindrical fuse carriers (4 x 5 mm) 63 A available with 4-7-6 DIN mod. 6 to 63 A available with a disconnection device integral with the cover Standard version 50 n Centre feed units 63 00 A 0 60 d max. = 3 6 5 6 5 size 25 mm 2 273 270 273 No. 2 d = max. Ø 55 0 0 0 No. 2 d = max. Ø 55 97 00 Long version 250 60 A 273 400 273 200 No. 2 d = max. Ø 63 3 6 size 70 mm 2 60 d max. = 3 6 5 6 5 size 25 mm 2 No. 2 d = max. Ø 63 97 0 20 0 All dimensions (mm) are nominal 25

MS double sided busbar technical information n Tap-off box with CH0 fuseholder (0 3 x 3) n End stop IP 55 30 45 55 60 d = max. Ø 29 5 5 5 5 size 0 mm 2 n Tap-off box with CH4 fuseholder (4 x 5) 0 42 d = max. Ø 29 n Joint cover IP 55 30 77 0 22 5 42 7 d = max. Ø 3 n Tap-off outlet cover IP 55 2 n 63 A tap-off boxes 09 0 0 d = max. Ø 55 23 n Suspension bracket 0 Hole 7 x 32 Hole 7 x Hole 7 x d = max. Ø 55 3 64 Tap-off box with hinged door (up to 6 modules DIN) Hole 7 x 0 20 d = max. Ø 55 7 0 Ø 7 25 55 47 5 All dimensions (mm) are nominal 26

MS double sided busbar technical data Complies to : IEC EN 6439-6 DIN VDE 0660 part 500 and 502 Suitable for the following climates : Constant humid climate (DIN IEC 6 and 2-3) Cyclical humid climate (DIN IEC 6 and 2-30) Short circuit protection for Zucchini product ranges (In 00 A) Zucchini busbar systems with a nominal current less or equal to 00 A (LB PLUS / MS 63 and 00 A) are correctly protected against short circuit effects through an MCB (Miniature Circuit Breaker) with a nominal current less or equal to the one of the busbar This protection is assured up to MCB short circuit withstand The busbar trunking systems LB PLUS / MS 63 and 00 A are flame retardant in compliance with IEC 332-3 : 992 63 00 60 Live conductors No. 4 4 4 Casing overal dimension A x B (mm) 39 x 97 39 x 97 39 x 97 Rated current In 63 00 60 Cross-section of conductors (3P + N) S (mm 2 ) 26 26 39 Cross-section of protective conductor eq. Cu SPE (mm 2 ) 2 2 2 Operational voltage Ue (V) 400 400 400 Insulation voltage Ui (V) 750 750 750 Rated frequency f (Hz) 50/60 50/60 50/60 Rated short-time current (0 s) Icw (ka)rms 3 5 5 5 5 Peak current Ipk (ka) 5 25 0 0 Maximum thermal limit I 2 (A 2 s x 06) 225 2 500 3 025 Phase resistance R20 (mω/m) 250 0 65 0 47 Phase reactance (50Hz) X (mω/m) 0 366 0 366 0 247 Phase impedance Z (mω/m) 302 0 753 0 53 Resistance of the protective bar RPE (mω/m) 0 57 0 57 0 57 Reactance of the protective bar (50Hz) XPE (mω/m) 0 090 0 090 0 02 Resistance of the fault loop Ro (mω/m) 5 26 0 Reactance of the fault loop (50Hz) Xo (mω/m) 0 456 0 456 0 349 Impedance of the fault loop Zo (mω/m) 9 34 3 VF = (2 R20 cosϕ +2 X senϕ) 2 Voltage drop with distributed load (k) V3F = 3 2 (R20 cosϕ + X senϕ) V (V/m/A)0-3 cosϕ = 0 70 0 9 0 63 0 44 V (V/m/A)0-3 cosϕ = 0 75 02 0 64 0 45 V (V/m/A)0-3 cosϕ = 0 0 06 0 65 0 46 V (V/m/A)0-3 cosϕ = 0 5 09 0 65 0 46 V (V/m/A)0-3 cosϕ = 0 90 0 65 0 47 V (V/m/A)0-3 cosϕ = 0 95 3 0 64 0 46 V (V/m/A)0-3 cosϕ = 00 0 0 57 0 4 Straight length weight p (kg/m) 2 0 2 6 2 Fire load (kwh/m) 64 64 64 Protection degree IP 40/55 40/55 40/55 Losses for the Joule effect at full load P (W/m) 4 9 9 7 36 7 Min./max. ambient temperature ( C) -5/+50-5/+50-5/+50 Temperature rating schedule Mean room temperature ( C) 5 20 25 30 35 40 45 50 55 60 K factor 5 2 0 05 025 0 975 0 95 0 93 0 9 Multiplier coefficient of nominal rating for room temperature values different from 40 C 27