Type DMX-N Surge Arresters Maximum System Voltage 2 to 36 kv

Similar documents
SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS

3EK8 distribution class surge arresters. Catalogue HP-AR Version siemens.com/arresters

COOPER POWER. UltraSIL Polymer-Housed VariSTAR Type U2Surge Arrester for Systems through 275 kv IEC 10-kA; Line Discharge Class 2 SERIES

VariSTAR Type AZL heavy-duty distribution-class MOV arrester

Effective February 2017 Supersedes January 2012 (CP1122)

Selection of MO surge arresters Overvoltage protection

Transformers connected via a cable Overvoltage protection

S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013)

VariSTAR Type AZU heavy-duty distribution-class under-oil MOV surge arrester

Surge Arresters. VariSTAR Type AZS Normal Duty Distribution Class MOV Arrester

Energy Division. Bowthorpe LV/MV Surge Arresters

LIGHTNING ARRESTOR. September 2017 WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED

TECHNICAL SPECIFICATION

Tab 8 Surge Arresters

ANSI DESIGN TEST REPORT Report No. EU1295-H-00 Type PVN Station Class Surge Arrester

AMENDMENT NO. 1 SEPTEMBER IS (Part 1) : 2001/IEC (1991) SURGE ARRESTORS

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

UltraSIL Polymer-Housed VariSTAR Normal-Duty, Heavy-Duty and Riser Pole Distribution-Class Arresters

POSI-BREAK Metal Oxide Varistor Elbow (M.O.V.E.) Surge Arrester

UltraSIL Polymer-Housed Evolution Distribution Class Surge Arrester Certified Test Report

SURGE ARRESTERS AND TESTING. Keith Hill Doble Engineering Company

Substation Design Volume VII

Low voltage products in high altitudes

Secondary Arresters. Figure 1. Type L secondary surge arrester rated 175 Vac, 125 Vdc.

35 kv Class M.O.V.E. DirectConnect elbow arrester

Insulation Co-ordination For HVDC Station

Metal Oxide Varistor Elbow (M.O.V.E.) Surge Arrester

Three-phase monitoring relay CM-PVE

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

Pluggable interface relays CR-U Universal relays

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

TECHNICAL NOTE 2.0. Overvoltages origin and magnitudes Overvoltage protection

MEDIUM VOLTAGE PRODUCT. KOKM Cable current instrument transformers Instruction for Installation, use and maintenance

Our experience. Our products

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

Analysis of Major Changes to Arrester Standards IEC STEVE BREWER

75 kva Isolation Transformer - 480V Delta Primary - 208V Delta Secondary - NEMA 3R

75 kva Isolation Transformer V Delta Primary Voltage - 480Y/277 Secondary Voltage - NEMA 3R

7.5 kva Isolation Transformer - 460V Primary - 230V Secondary - NEMA 3R - Single Phase - 50/60 Hz

Three-phase monitoring relay CM-PBE

MEDIUM VOLTAGE PRODUCT. TJP 6.1, TJP 6.2 Indoor voltage transformers

Eaton s Cooper Power Series DEADFRONT ARRESTERS

Construction zglass passivated collar zaluminum termination for pressure contact

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

Three-phase monitoring relays CM-PFE and CM-PFE.2

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

MEDIUM VOLTAGE PRODUCT. TJP 5.x Indoor voltage transformers

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

Power supply CP-T 48/20.0 Primary switch mode power supply

500 kva Isolation Transformer - 480V Delta Primary - 400Y/231 Wye Secondary - NEMA 3R

10 kva Transformer - 480V Primary Voltage - 208V Secondary Voltage - Single Phase - NEMA 3R

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

A Case Study on Selection and Application of Lightning Arrester and Designing its Suitable Grounding Grid

Three-phase monitoring relay

PRODUCT FOR HIGH VOLTAGE APPLICATION. Current transformers for Gasinsulated. Instructions for installation, use and maintenance

ENERGY /// POLYMERIC SURGE ARRESTERS (IEEE) BOWTHORPE EMP POLYMERIC SURGE ARRESTERS (IEEE)

Electronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact

Electronic timer CT-SDS.22

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Three-phase monitoring relays CM-PVS.81

1.5 kva Single Phase Transformer - 120V Primary Voltage - 277V Secondary Voltage - NEMA 3R

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

80 kva Isolation Transformer - 480V AC Primary - 20V AC Secondary - NEMA 3R - Single Phase

Power supply CP-D 12/2.1

225 kva Autotransformer - 240V Delta Primary Voltage - 220V Delta Secondary Voltage - NEMA 3R

MEDIUM VOLTAGE PRODUCT. TPE 6x.xx Indoor supporting current transformers

HP ProCurve 6.9/7.7dBi Dual Band Directional Antenna (J8999A) Guide

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-T 48/5.0 Primary switch mode power supply

15 kva Isolation Transformer - Single Phase - 208V Primary - 120/240V Secondary - NEMA 3R

Type SSVT oil-filled station service voltage transformer Auxiliary power from high voltage transmission lines

Howard Smart Transformer Specification Guide

MEDIUM VOLTAGE PRODUCT. PARAMETERS GUIDE How to specify the indoor instrument transformers correctly

International Journal of Advance Engineering and Research Development. Analysis of Surge Arrester using FEM

5 kva Isolation Transformer - 115V Primary Voltage - 230V Secondary Voltage - Single Phase - NEMA 3R

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Network Standard NETWORK. Document No Amendment No Approved By Approval Date Review Date NW000-S0142 : : : : : Head of AEP&S 08/06/ /06/2017

Type 297, High-Voltage Mica Capacitors Corona-free Mica Coupling Capacitors for Medium-Voltage PDA s

500 kva Dry-type Isolation Transformer V-Delta to 208Y/120V 3PH - NEMA 1/Indoor

3EE2 Special-Purpose Surge Arresters for the Protection of Motors, Generators and Furnace Transformers

Specialty Switches. Inertia Engineering & Machine Works, Inc Hardaway Road, Stockton CA 95215

MEDIUM VOLTAGE PRODUCT. TJP 7.x Indoor voltage transformers

VI 3 - i TABLE OF CONTENTS

micro DOUBLE TEN SWITCH

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Distribution/Substation Transformer

RESULTS OF EXPERIMENTAL HIGH CURRENT IMPULSE 4/10 s OF METAL OXIDE VARISTORS ZINC IN THE HIGH VOLTAGE 220KV SURGE ARRESTER

Transcription:

Type DMX-N Surge Arresters Maximum System Voltage 2 to 36 kv

DMX-N gapless metal oxide surge arresters DMX-N surge arresters are used for the protection of switchgear, transformers and other equipment in high voltage systems from atmospheric and switching overvoltages. DMX-N surge arresters can also be used when lightening intensity or energy capability requirements are high or in case of heavy pollution. The superior design of the DMX-N surge arresters supports conditions which require low weight, reduced clearances, flexible mounting, and shatter-proof housing. Application The DMX-N gapless metal oxide polymer Surge Arrester has been veri ied to meet or exceed all heavy duty distribution class requirements of ANSI C62.11 (IEEE Standard for Metal-Oxide Surge Arresters for AC Power Circuits as a normal duty distribution class arrester. The DMX-N Surge Arrester is designed to meet the following performance data: Performance data Maximum system voltages (V m Duty cycle rated voltages ( Classifying current (IEEE Discharge current withstand strength: High current 4 / 10 µs Low current 2000 µs Energy capability: Short-circuit / pressure relief capability 2.52-36.2 kms 3-45 kms 5 ka peak 65 ka peak 150 A peak 3.3 kj/kv of MCOV 16 ka rms sym Service conditions: Ambient temperature -50 C to + 45 C Design altitude 6000 ft / 1830 m Frequency 15-62 Hz Type tested to the following standards: IEEE standard C62.11a Notes: 1 Higher altitude designs available on request 2 DMX-N Metal Oxide Gapless Surge Arresters

Benefits 100% silicone based housing ABB s DMX-N Surge Arrester now has a new construction to enhance overall lifetime performance. The arrester consists of high performance metal oxide disks molded in a shatterproof silicone polymer housing. The silicone rubber housing features high tracking and arc resistance, excellent hydrophobic properties, and resistance to weathering, Uadiation and pollution. The incorporation of polymer material in a distribution class arrester has resulted in many advantages, including: Direct-molded construction The metal oxide disks are enclosed in a support assembly consisting of reinforced epoxy/fiberglass loops connecting the upper and lower aluminum end pieces. The silicone polymer material is then molded directly to the metal oxide loop assembly, eliminating any air pockets which could cause moisture ingress over time. Lightweight The DMX-N Surge Arrester is less than 50 percent the weight of its porcelain counterpart, which results in easier handling and installation. Damage resistant Polymer construction reduces possible shipping and handling damage, as well as, damage due to vandalism. Safety Shatter-resistant construction provides greater protection for personnel, as well as, nearby equipment. Configuration options The arrester can be furnished with a variety of mounting configurations, as well as various configurations for line and ground electrical connections. Reduced electrical clearance Polymer construction has resulted in much smaller housing dimensions in comparison with porcelain units of the same voltage rating. This size reduction enables efficient use of space for switchgear enclosures, mobile substations and other applications where space restrictions are present. Nameplate Standard (Stainless steel DMX-N Metal Oxide Gapless Surge Arresters 3

Quick selection guide System Voltage Surge Arrester Nominal ANSI/IEEE Ratings Four-Wire Four-Wire Maximum Three-Wire Four-Wire Three-Wire Grounded Grounded High Impedance V m V n V n / V MCOV / V MCOV / V MCOV Medium Voltage 2.52 2.4 3 / 2.55 4.37Y / 2.52 4.16Y / 2.4 3 / 2.55 5 / 4.25 4.37 4.16 5 / 4.25 5.04 4.8 6 / 5.1 7.24 6.9 9 / 7.65 8.73Y / 5.04 8.32Y / 4.8 6 / 5.1 12 / 10.2 12.6Y / 7.27 12.0Y / 6.93 9 / 7.65 15 / 12.7 13.09Y / 7.56 12.47Y / 7.2 9 / 7.65 18 / 15.3 13.86Y / 8.0 13.2Y / 7.62 10 / 8.4 18 / 15.3 14.49Y / 8.37 13.8Y / 7.97 10 / 8.4 18 / 15.3 14.49 13.8 18 / 15.3 21.82Y / 12.6 20.78Y / 12.0 15 / 12.7 27 / 22 24.0Y / 13.86 22.86Y / 13.2 18 / 15.3 30 / 24.4 24.15 23 30 / 24.4 26.19Y / 15.12 24.94Y / 14.4 21 / 17 33 / 27 36.23Y / 20.92 34.5Y / 19.92 27 / 22 42 / 34 36.23 34.5 48.30 46 36 / 29 Key V n Nominal System Voltage per NEMA C84.1 V m Maximum System Voltage per NEMA C84.1 Duty Cycle Rated Voltage per IEEE C62.11 MCOV Maximum Continuous Operating Voltage per IEEE C62.11 TOV SPL LPL FOW Temporary Overvoltage Switching Protective Level 500 A 3-132 Lightning Protective Level Front of Wave 4 DMX-N Metal Oxide Gapless Surge Arresters

Guaranteed performance data and technical data for housings Electrical characteristics Ratings TOV Maximum residual voltage with current wave, (kv peak Voltage MCOV SPL (SIPL 30/60 µs LPL (LIPL 8/20 µs FOW 0.5 µs V MCOV 1 sec 10 sec 500 A 1.5 ka 3 ka 5 ka 10 ka 20 ka 10 ka 3.0 2.55 3.15 3.0 11.1 9.2 9.7 10.2 11.4 12.6 12.0 6.0 5.10 6.30 6.0 16.6 18.4 19.4 20.3 22.8 25.2 23.5 9.0 7.65 9.45 9.0 22.2 27.6 29.1 30.5 34.2 37.8 35.5 10.0 8.40 10.50 10.0 27.7 28.5 30.1 31.5 35.3 39.0 36.5 12.0 10.20 12.60 12.0 33.2 36.6 38.6 40.6 45.4 50.1 47.0 15.0 12.70 15.75 15.0 38.8 45.7 48.2 50.7 56.7 62.6 59.0 18.0 15.30 18.90 18.0 44.3 53.3 56.2 59.0 66.0 73.0 67.0 21.0 17.00 22.05 21.0 49.8 63.2 66.6 70.0 78.3 86.6 81.0 24.0 19.50 25.20 24.0 55.3 73.0 77.0 81.0 90.5 100.0 94.0 27.0 22.00 28.35 27.0 60.9 78.5 82.7 87.0 97.2 107.5 101.0 30.0 24.40 31.50 30.0 66.0 85.2 89.8 94.5 105.6 116.7 109.5 36.0 29.00 37.80 36.0 83.1 104.6 110.3 116.0 129.6 143.3 134.5 Vertical mounting styles with standard creepage distance Surge Arrester IEEE Ratings / V MCOV (kv Style Number Creepage Distance inches (mm Strike Distance inches (mm BIL 1.2/50 µs Weight A dry (Mass max kv peak lbs (kg inches (mm Fig 3.0 / 2.55 DMX-N 3 8.62 (219 4.45 (113 17.1 1.33 (0.61 3.97 (101 1 6.0 / 5.10 DMX-N 6 8.62 (219 4.45 (113 34.2 1.44 (0.66 3.97 (101 1 9.0 / 7.65 DMX-N 9 12.51 (318 5.75 (146 52.0 1.82 (0.84 5.15 (131 2 10 / 8.40 DMX-N 10 12.51 (318 5.75 (146 52.0 1.82 (0.84 5.15 (131 2 12 / 10.2 DMX-N 12 23.98 (609 8.74 (222 68.2 2.87 (1.32 7.48 (190 3 15 / 12.70 DMX-N 15 23.98 (609 8.74 (222 68.2 2.98 (1.37 7.48 (190 3 18 / 15.30 DMX-N 18 23.98 (609 8.74 (222 68.2 3.10 (1.42 7.48 (190 3 21 / 17.00 DMX-N 21 28.90 (734 10.28 (261 140.0 3.71 (1.71 9.21 (234 4 24 / 19.50 DMX-N 24 28.90 (734 10.28 (261 140.0 3.77 (1.74 9.21 (234 4 27 / 22.00 DMX-N 27 44.30 (1125 14.65 (372 170.0 5.22 (2.40 13.58 (345 5 30 / 24.40 DMX-N 30 44.30 (1125 14.65 (372 170.0 5.33 (2.45 13.58 (345 5 36 / 29.00 DMX-N 36 44.30 (1125 14.65 (372 170.0 5.56 (2.56 13.58 (345 5 1 Arrester assembly consists of arrester unit, line and ground terminals. DMX-N Metal Oxide Gapless Surge Arresters 5

Style numbering system Single rated surge arresters 1 2 3 4 5 6 7 8 9 10 11 N A Style Number Digit 1 DMX-N Normal Duty Distribution Class Arrester N 2-4 Arrester Rated (Duty Cycle Rating ( `003 = 3.0 / 2.55 `018 = 18 / 15.3 `006 = 6.0 / 5.10 `021 = 21 / 17.0 `009 = 9.0 / 7.65 `024 = 24 / 19.5 `010 = 10 / 8.40 `027 = 27 / 22.0 `012 = 12 / 10.2 `030 = 30 / 24.4 `015 = 15 / 12.7 `036 = 36 / 29.0 5 Creepage Distance A = Standard design 6 Line Hardware A = Stud only (no hardware B = Stainless steel wire clamp C = Stud with stainless steel nut, flat washer and lock washer X = No hardware 7 Line Leads 1 = 36, #6 AWG insulated wire - 2 ring terminals 6 = 20, #6 AWG insulated wire - shipped 1 both ends 2 = 36, #6 AWG insulated wire - 1 ring terminal / 1 end shipped 1 7 = 13, #6 AWG insulated wire - 2 ring terminals 3 = 36, #6 AWG insulated wire - shipped 1 both ends 8 = 13, #6 AWG insulated wire - 1 ring terminal / 1 end shipped 1 4 = 20, #6 AWG insulated wire - 2 ring terminals 9 = 13, #6 AWG insulated wire - shipped 1 both ends 5 = 20, #6 AWG insulated wire - 1 ring terminal / 1 end shipped 1 X = No line terminal wire 8 Protective Cap Y = Yes N = No 6 DMX-N Metal Oxide Gapless Surge Arresters

Optional mountings Style Number Digit 9 Ground Hardware A = Stud only (no hardware B = Stainless steel wire clamp C = Stud with stainless steel nut, flat washer and lock washer X = No hardware 10 Mounting Options 1 = No mounting options 2 = Insulated bracket 3 = Insulated bracket with NEMA cross arm bracket 4 = Insulated bracket with Transformer bracket - 8.7 5 = Insulated bracket with Transformer bracket - 11 6 = Insulated bracket with Transformer bracket - 12.25 7 = Insulated bracket with Transformer bracket - 14.25 11 Packaging A = Individual Carton (Assembled Terminal Hardware. Each arrester is shipped in an individual high strength cardboard carton. The top and bottom terminal hardware is assembled to the arrester. Any optional brackets or hardware are provided unassembled. B = Bulk Packed (Assembled Terminal Hardware. Pallet sized bulk cardboard packaging for transformer mounting bracket options (Digit 10, 4-7 only. Each arrester is shipped fully assembled including transformer mounting bracket. Available for 3-24 kv arresters only. Full pallet quantities only: 3-10 kv = 90, 12-18 kv = 72, 21-24 kv = 40. DMX-N Metal Oxide Gapless Surge Arresters 7

Contact us ABB Inc. High Voltage Products - Surge Arresters 100 Distribution Circle Mount Pleasant, Pennsylvania 15666, USA Phone: +1 (724 696-1568 Fax: +1 (724 696-1502 www.abb.us Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction in whole or in parts is forbidden without ABB s prior written consent. Copyright 2015 ABB. All rights reserved. Document Number: 2GNM110148 / March 2015