Fastener Hole Crack Detection Using Adjustable Slide Probes

Similar documents
Array Eddy Current for Fatigue Crack Detection of Aircraft Skin Structures

VD3-71 universal eddy current flaw detector application for field inspection of aeronautical engineering

Corrosion Steel Inspection under Steel Plate Using Pulsed Eddy Current Testing

EDDY CURRENT INSPECTION FOR DEEP CRACK DETECTION AROUND FASTENER HOLES IN AIRPLANE MULTI-LAYERED STRUCTURES

DETECTION OF THE SUBSURFACE CRACKS PROPAGATED FROM RIVET HOLES IN THE MULTILAYER AIRCRAFT STRUCTURES

MM540 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Predator Probe Theory and Operation

DEEP FLAW DETECTION WITH GIANT MAGNETORESISTIVE (GMR) BASED SELF-NULLING PROBE

MM340 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Eddy Current Array for Aerospace

EMAT Application on Incoloy furnace Tubing Ramamohan Reddy M (ASNT Level III UT, PCN Level III UT,PAUT&TOFD)

AA&S Conference 2018 Eddy Current Array for Aircraft

Optical Illusion Sketchbook Project Art 1201

Maximizing the Fatigue Crack Response in Surface Eddy Current Inspections of Aircraft Structures

Working with Wood & Tools. Marking and Measuring. Tools you will need:

woodworkersjournal.com MATERIAL LIST

DP-8 H. H. MØRCH. Instructions. Contents of the packing. Spatial requirements. Mounting the bush

E N G L I S H GARDEN SHED. Assembly Instructions. Suitable for Models WITH VARYING DEPTHS

Detecting 1 st and 2 nd Layer Simulated Cracks in Aircraft Wing Spanwise Splice Standards Using Remote-Field Eddy Current Technique

A Novel Self Calibrating Pulsed Eddy Current Probe for Defect Detection in Pipework

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

Siding Systems NOVIKSTONETM FS FIELDSTONE INSTALLATION GUIDE

Detecting Compressive Residual Stress in Carbon Steel Specimens of Flat Geometries Using the Remote-Field Eddy Current Technique

New portable eddy current flaw detector and application examples

PAT installation of a Sun Dome over a in-ground

TOOL LIST FOR TAILGATE HIDDEN LATCH & LINK ASSY FOR FORD FLARESIDE TRUCKS

A Breakthrough in Sputtering Target Inspections: Ultra-High Speed Phased Array Scanning with Volume Focusing

DEVELOPMENT OF VERY LOW FREQUENCY SELF-NULLING PROBE FOR INSPECTION OF THICK LAYERED ALUMINUM STRUCTURES

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

CONTENTS. Transitions Board and Batten Vertical Installation... 10,11

DEEP PENETRATING EDDY CURRENT for DETECTING VOIDS in COPPER

Measurement and Inspection and Testing

INSTALLATION MANUAL FORTRESS SERIES

Eddy current flaw detector «Eddycon C»

7878 K940. Checkpoint Antenna. Kit Instructions. Issue B

Series----SP3600A SHOWER DOOR

Frameless Inline Door QCI5254

An explanation for the magic low frequency magnetic field shielding effectiveness of thin conductive foil with a relative permeability of 1

UNPACK & ASSEMBLY. Done! CAUTION! THE MILL WILL BE VERY HEAVY - GET ASSISTANCE Pepe Tools.

Woodline USA Woodline Spacer Fence System

INSTALLATION INSTRUCTIONS VENETIAN 84" SLIDING SHOWER DOOR SYSTEM (180º INSTALLATION)

KAERI Feeder Tube Inspection Using EMAT Generated Circumferential Guided Waves

Electric Skein Winder

Dura-Lock Roof System

SINGLE TRACK BYPASS (patent pending) barn door hardware

Spandrel Information and Installation Guide

METALWORKS Concealed. Installation Instructions

Installation Manual SOLID CORE SIDING

Frameless Inline Door With Return QCI5263

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Series 1500 Aluminum Door Canopy

Storefront Installation Guide

2.5D Finite Element Simulation Eddy Current Heat Exchanger Tube Inspection using FEMM

Sawn Baluster Sizing and Installation Guide

FRAMELESS DOOR / PANEL WITH WALL MOUNT HINGES QCI5274

C-Series & S-Series Classic Frame with Transom (Single or Pair)

High-Precision Internal Diameter Measurements Using Eddy Current Arrays

PORCH-LOC INSTALLATION INSTRUCTIONS

DETECTION OF SUB LAYER FATIGUE CRACKS UNDER AIRFRAME RIVETS

Phone # La Jolla Doors. Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels

Note Pad Holder. Tools:

PT50A Industrial, PT50B & PT50C Sharp

Steam Generator Tubing Inspection

Weld gap position detection based on eddy current methods with mismatch compensation

Installation Instructions for Siding

Series 1100 Aluminum Door Canopy

Novel Demagnetization Method after Magnetic Particle Testing

The Battle of Carbon Steel

FIXED PANEL SLIDER QCI5241

Imaging for 3D Eddy Current Nondestructive Evaluation Pasquale Buonadonna Sponsored by: INFM

RoofScreen Mfg., Inc. DryCap Installation Manual Updated Introduction This manual Application System Overview...

OWNER S MANUAL. Safety. Please read this owner s manual before use and keep it at hand for reference. Warranty

Tu r n y o u r p r e s s b r a k e o r p u n c h p r e s s i n t o a h o l e p u n c h i n g p r o f i t c e n t e r.

Extendable Swing Shut Gate

Ripple and Uniformity Measurement of a Phased-Array Testing-Machine for round-bar Testing

Straight Stringer Installation Instructions

UNPACK & ASSEMBLY. Done! CAUTION! THE MILL WILL BE VERY HEAVY - GET ASSISTANCE Pepe Tools.

Installation for Full Size Polaris Ranger Crew Doors

Eddy Current Modelling for Fasteners Inspection in Aeronautic

Nanton Grain Mill Assembly

Making an Omega Nut. By R. G. Sparber. Copyleft protects this document. 1

ECE 203 LAB 6: INVERTED PENDULUM

Frameless Inline Door QCI5250

a.k.a. casegoods instructions

Read Below! Read Below! Read Below! Read Below! Read Below! Read Below! STOP READ TIPS BELOW TO MAKE ASSEMBLY MUCH EASIER

Assembly Instructions

Evertune ET001F and ET001T Router Template Instructions

Installation Guidelines

1. Turn off or disconnect power to unit (machine). 2. Push IN the release bar on the quick change base plate. Locking latch will pivot downward.

1200 SERIES 2 PANEL DOOR rev.1 DETAILED INSTALLATION INTRUCTIONS

Why are we giving this guidebook as a FREE download?

Corso di Studi di Fabbricazione

Merloni Elettrodomestici. Technical Fitting Manual FRIDGE. Language Issue/Edition Page GB /

Travis Bishop. Submitted to: Dr. John Davis. Date: 3 December Course: ETME 310 Section: 004. Lab Topic: Milling Project (Vise)

A-935 RODA WALL MOUNT HINGES

OWNER S MANUAL. But that s just half the story. The fence INCRA Miter Gauge really does work

Read Below! Read Below! Read Below! Read Below! Read Below! Read Below! STOP READ TIPS BELOW TO MAKE ASSEMBLY MUCH EASIER

Curved Baluster Railing Systems

A Numerical Study of Depth of Penetration of Eddy Currents

INS A KSCR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Unpacking the KSCR Splicing the KSCR (If Required)...

Transcription:

Fastener Hole Crack Detection Using Adjustable Slide Probes General The guidelines for the adjustable sliding probes are similar to the fixed types, therefore much of the information that is given here follows the same sequence and detail and will look like repetition. This is done so that both technical bulletins are self contained and may be read independently, but is best to become familiar with the fixed probes first. Sliding probes have been named as such because they move over fasteners in the inspection area in a sliding motion. Conventionally, probes are used in "spot probing" such as with a ring-encircling probe or moving a spot/surface probe around the periphery of a fastener. Sliding probes are eddy current probes operating in the reflection mode (transmitreceive). This means that the eddy currents are induced by the driver coil (transmitter) and detected by a separate pick up coil (receiver). With adjustable types, a spacer is inserted between the two coil bodies. Sliding probes are the fastest method to inspect large numbers of fastener holes for cracks. They are capable of detecting small defects in both the surface and subsurface layers. Adjustable sliding probes are particularly well suited for finding subsurface cracks in thick multilayer structures, like wing skins. They differ with the fixed types in that they are most often moved at right angles to the crack direction (although the probe is turned 90 degrees) in what is called a 90 degree scan (see the Appendix). The sensitive area is located in the center of the probe between the coils and is

directionally sensitive, so the engraved (normally green) "detection" line must be kept in the direction of the expected cracks. Two types of scan are possible: one scan centralized over the heads or two side (tangential) scans, one in each side of fastener. Surface and Subsurface Crack Detection Adjustable sliding probes are normally used for subsurface crack detection and rarely for surface cracks where the fixed sliding probes will normally have an advantage. Nevertheless there are some exceptions such as in the case of large or magnetic fasteners and/or if the crack growth direction is at 90 degrees to the fastener row. The penetration will increase with the larger size probes and depths of 0.75 in. (20 mm) have been possible, although the small sizes are the most common and can also be used down to 100 Hz. Liftoff Adjustment When the probe is passed over the fastener head an indication will be obtained similar to that of Figure 1. This is very similar to the fixed types. The liftoff is normally adjusted to be horizontal as it is the conventional direction. As the signal is not a straight line but a curve, it is important to remember that we only need a reasonable compensation for the expected lift off variations caused by paint and fastener head unevenness. A horizontal movement of the dot for the first 0.01 in. (0.25 mm) to 0.02 in. (0.5 mm) of lift off is satisfactory. In Figure 1 it is the movement from the null point "X" to point "Y", which will only cause a mainly horizontal shift of the display along that distance. Figure 1 Even this small distance can be a steep curve and may have to be allowed to move slightly upwards before moving downwards (see Figure 2). The amount of vertical movement for the required lift off is distributed so that the display only shifts slightly above or below horizontal.

Figure 2 Probe Adjustment The spacer thickness between the coils is normally adjusted for the best detection. If the notch used for calibration is long enough (to give a good indication) it is quicker to centralize it over the head and perform one scan only (typical spacer thickness for the single scan inspection is approximately the fastener diameter). Check that the notch is still detectable if the probe is turned 180 degrees. This type of scan may not be possible with some large head or magnetic fasteners. For tangential scans a thinner spacer is often better, but the final decision depends on the experimental results obtained with the reference standard and the structure to be inspected. The spacer thickness range can vary from 0 (no spacer) for inspections close to the surface and small fastener heads to a maximum of about 0.3 in. (8 mm) for deep penetration on large heads with bigger probe types. A wider spacer will give more tolerance to probe deviation as the sensitive area becomes wider, but the instrument will require more gain. Signal Interpretation When the probe moves over a fastener hole with no cracks in the normal 90 degree scan, the indication is narrow, but if we scan at 0 degrees the indication becomes a loop. See Figure 3 and Appendix: (Scan Directions to Insure All Cracks are Evaluated). The loop is produced by a continuous phase change as the driver and pick up coils travel over the fastener and is wider than with the fixed probes. When the dot is at point "a" the probe is totally centralized (common to both scanning directions).

Figure 3 Crack Detection When the probe moves over a fastener hole with a crack the indication changes and typically will create a larger loop and vertical movement (see Figure 4). Figure 4 The main difference between scanning in the crack direction or at right angle to the crack is the shape of the indication. The dotted line shows the indication obtained when the probe travels over the length of the crack (0 scan), where the solid line shows the indication from traveling at right angles to the crack (the normal 90 scan). The reason is when the crack is scanned "slowly" along its length, the phase changes, displaying a loop - but when moving at right angles to the crack, it is seen by the probe "abruptly", and gives a sharp narrow signal. This signal will meet the loop at some point in its travel depending on the probe alignment. Both these signals can be observed by scanning the same fastener hole in the two directions. See Appendix: (Scan Directions to Insure All Cracks are Evaluated). If two cracks in opposite sides of the fastener hole are present with the probe moving at right angles and centralized over the fastener the indications will typically add up to a larger indication. This is because both are being detected at the same time (with a fixed probe they would normally be detected one after the other in a 0 scan). Variables: Probe Scan Deviation

It is important to try to keep the probe centralized over the fastener heads. This corresponds to a maximum indication for the fastener and also the crack. In Figure 5 the indication "a" corresponds to a perfectly centralized probe, while indications "b" and "c" correspond to increasing deviation from the center line. The dotted line marks the path of the changing deviation (See Appendix). Figure 5 If the probe deviates from the center line, the crack indication will move along the loop that we saw in Figure 4 and is now presented in Figure 5. The crack indication is at "a" when the probe is centralized and moves towards "b" as it deviates in one direction or "c" as it deviates in the opposite direction. Point "b" gives an improved indication even if it loses a small amount of amplitude it has gained in phase, giving a better separation angle (this is because we deviated to the side where the crack is located). This is the reason why two tangential side scans are more sensitive to smaller cracks than one centralized scan. When the probe deviates in the opposite direction the signal from the crack moves towards point "c", where it loses too much phase and amplitude and starts looking more like the normal fastener indication (particularly for a small size defect that the one represented in Figure 5). This is why a second tangential scan in the opposite side is needed. Other Variables: Crack Angle Deviation A reduction in the crack indication occurs when the crack is at an angle to the probe scan direction. This happens if the crack is not completely at 90 degrees to the normal probe scan or changes direction as it grows. The effect is also very similar if the probe is not at right angles but at a smaller angle of attack. See Appendix: (Scan with a Deviation Angle). The adjustable sliding probes are capable of detecting cracks up to about 30 degrees off angle, and will give a reduced indication proportional to the amount of deviation, see Figure 6. The effect is similar to that obtained with the fixed sliding probes.

Figure 6 Other Variables: Electrical Contact When inspecting fasteners that have just been installed or reference standards that have intimate contact with the aluminum skin plate, it is not unusual to obtain a smaller than normal indication. In some extreme cases the fastener indication may disappear almost completely. This is due to the good electrical contact between the fastener and the skin that allows the eddy currents to circulate without finding the boundary and therefore no obstacle or barrier. Figure 7 shows the decrease of the fastener indication due to close contact. This problem is found more frequently with riveting and rarely with other fasteners, particularly if used with nuts or collars. Nevertheless, because of this effect it is recommended to paint the holes on the reference standard before fastener installation. In this way the reference standard will simulate the real life structure that due to the temperature changes, moisture and movement that always creates a natural oxide layer between fastener and skin. Notes: Cracks are considered detectable up to +/- 30 degrees, but it also depends on depth and crack length. Longer cracks are more likely to be detected off angle. It is important to avoid the probe hitting the edge of the fastener head. If the spacer does not provide enough gap to allow clearance over the fastener heads it is advisable to create one using thin strips (skis) of tape. To provide the best presentation it is usual to set the vertical gain a few db above the horizontal gain. It is often helpful to use a non metallic straight edge to guide the probe over the line of fasteners, particularly if heavy paint makes it difficult to see the heads. In extreme cases, it may be necessary to locate two fasteners to locate the row using the sliding probe. If the fastener heads are not reasonably aligned, it is probably best to scan by hand, taking care to guide the probe along with the same alignment to the fastener head. To find a crack direction more accurately, approach the fastener at different angles until you obtain the largest indication. When inspecting magnetic steel fasteners it is often helpful to place a very thin magnetic steel shim under the driver coil. As the probe will see the steel shim all the

time, the dot will move less when traveling from aluminum to the magnetic fastener head and will produce a smaller indication. If the fastener spacing is close enough to allow a head to be under each coil, a downwards indication will be obtained but is normally easily identified from a crack. Appendix Typical Center Scan with an Adjustable Probe Typical Side Scan (Tangential) with an Adjustable Probe (two scans normally required) Scan Directions to Insure All Cracks are Evaluated Scan with a Deviation Angle