6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)

Similar documents
SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 8 DI 24V DC; 6 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC

6ES BE30-0XB0 6ES AE30-0XB0 6ES HE30-0XB0

Product type designation. General information. Hardware product version 01. Firmware version V2.6. Engineering with. update.

SIPLUS SM 1234 ANALOG INPUT/OUTPUT MODULE

6ES7314-6BH04-0AB0. STEP7 as of V5.5 + SP1 or STEP 7 V5.3 + SP2 or higher with HSP 204

Product type designation. General information. Supply voltage

CPU 314C-2 PTP. Function

General information. Supply voltage

100 h; (min. 70 h at 40 C); 200 days (typ.) with optional battery module Memory Number of memory modules (optional)

SM 1222 DIGITAL OUTPUT MODULE

CPU 221, CPU 222, CPU 224, CPU 224 XP, CPU 224 XPsi, CPU 226

SM 1223 DIGITAL INPUT/OUTPUT MODULE

General specifications and features

Data sheet CPU 013C (013-CCF0R00)

2A (recommended) Power loss

Data sheet CPU 313SC (313-5BF13)

Data sheet CPU 314ST/DPM (314-6CF02)

Data sheet VIPA CPU 314SC DPM (314-6CG23)

FM COUNTER MODULE

FM COUNTER MODULE

FM HIGH-SPEED BOOLEAN PROCESSOR

EXM INPUT/OUTPUT EXPANSION

FM COUNTER MODULE

FM 355 CONTROLLER MODULE

PLC-K506 Series FEATURES DESCRIPTION FEATURES

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

SIMATIC S7-300 Function modules

02/11/2015

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

08/07/2015

Electronic timer CT-TGD.22

02/11/2015

em4 local - Robust Specific characteristics Part number

Type CP-S, CP-C & CP-A Switch mode

02/11/2015

Overcurrent Protection / 7SJ45

CP-T range Product group picture

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

02/11/2015

Custom "Compact" range with display CD20 Custom Part number

General information. CiR - Configuration in RUN

em4 em4 alert em4 alert 2G

CP-T range Benefits and advantages

DOBLE F6150e TECHNICAL SPECIFICATIONS

02/11/2015

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

Multifunctional counter tico 772/773/774

Switching power supplies CP range, Linear power supplies CP-L range. Content

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

QUINT-PS-24DC/24DC/10

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC

This data sheet is only valid in association with the IL SYS INST UM E user manual.

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

PHOENIX CONTACT - 09/2009

Zentralbaugruppen CPU 222

CP-E range Benefits and advantages

Power supply CP-D 24/4.2 Primary switch mode power supply

AIO and DIO PFXLM4B01DAK:Sink Output Type PFXLM401DAC:Source Output Type Virtual Resolution (pixels)

FM POSITIONING MODULE

Analog signal converters CC-E I/I

PFXLM4B01 D * * (1) (2) (3) (4)

Primary switch mode power supplies Product group picture

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

Electronic timer CT-SDD.22

02/11/2015

Power supply CP-D 24/1.3

IBS IP CDIO/R 24-8 IBS IP CDIO/R 24-8/SF

08/07/2015

SEN TRONIC AG. Millenium 3 Essential. Essential range: powerful but cost effective. Part numbers. Accessories

20 General technical data XI/ON

Power supply CP-D 12/2.1

02/11/2015

Power supply CP-T 48/5.0 Primary switch mode power supply

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Power supply CP-T 24/10.0 Primary switch mode power supply

S200 I/O System Units

Power supply CP-T 24/40.0 Primary switch mode power supply

02/11/2015

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

0 2 1 â Ó. itemp HART TMT182. Technical Information

Product Data Sheet 3252J/2H3PU

Temperature Transmitter itemp RTD DIN rail TMT 127

DOBLE F6150SV TECHNICAL SPECIFICATIONS

Temperature transmitter itemp RTD DIN rail TMT 127

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

Power supply CP-T 48/20.0 Primary switch mode power supply

Programming restrictions when operating SM 331; AI 8 x RTD with PROFIBUS masters which only support DPV0.

SIMATIC S5. ET 100U Distributed I/Os. Manual. EWA 4NEB a

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Current ON state current ma minimum, 6 ma typical, 10 ma maximum OFF state current ma maximum

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

CL Range Logic relays. Logic relays. Logic relays. Phone: Fax: Web:

B850 Boiler House Energy Monitor

Power supply CP-E 24/0.75

Lexium integrated drives

Transcription:

6ES7214-1AG31-0XB0 Page 1 Product data sheet 6ES7214-1AG31-0XB0 SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Engineering with Programming package As of STEP 7 V11.0 SP2 Supply voltage 24 V DC permissible range, lower limit (DC) 20.4 V permissible range, upper limit (DC) 28.8 V Load voltage L+ Rated value (DC) 24 V permissible range, lower limit (DC) 20.4 V permissible range, upper limit (DC) 28.8 V Input current Current consumption, max. 1.5 A ; 24 V DC Inrush current, max. 12 A ; at 28.8 V Encoder supply 24 V encoder supply 24 V Permissible range: 20.4 to 28.8 V Output current Current output to backplane bus (DC 5 V), max. 1600 ma ; 5 VDC max. for SM and CM Power losses Power loss, typ. 12 W Memory Usable memory for user data 75 kbyte

6ES7214-1AG31-0XB0 Page 2 Work memory integrated expandable Load memory integrated Backup present without battery CPU processing times for bit operations, min. for word operations, min. for floating point arithmetic, min. CPU-blocks Number of blocks (total) OB Number, max. Data areas and their retentivity retentive data area in total (incl. times, counters, flags), max. Flag Number, max. Address area I/O address area I/O address area, overall Process image Inputs, adjustable Outputs, adjustable Hardware configuration Number of modules per system, max. Time of day Clock 75 kbyte No 4 Mbyte (maintenance-free) 0.085 µs ; / instruction 1.7 µs ; / instruction 2.5 µs ; / instruction DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used Limited only by RAM for code 10 kbyte 8 kbyte ; Size of bit memory address area 1024 bytes for inputs / 1024 bytes for outputs 1 kbyte 1 kbyte 3 comm. modules, 1 signal board, 8 signal modules

6ES7214-1AG31-0XB0 Page 3 Hardware clock (real-time clock) Deviation per day, max. 60 s/month at 25 C Backup time Digital inputs Number/binary inputs of which, inputs usable for technological functions integrated channels (DI) 14 m/p-reading Number of simultaneously controllable inputs all mounting positions up to 40 C, max. 14 Input voltage Rated value, DC for signal "0" for signal "1" Input current for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs Parameterizable at "0" to "1", min. at "0" to "1", max. for interrupt inputs Parameterizable for counter/technological functions Parameterizable Cable length Cable length, shielded, max. Cable length unshielded, max. Digital outputs Number/binary outputs 10 of which high-speed outputs 480 h ; Typical 14 ; integrated 6 ; HSC (High Speed Counting) 24 V 5 V DC at 1 ma. 15 VDC at 2.5 ma. 1 ma 0.2, 0.4, 0.8, 1.6, 3.2, 6.4, and 12.8 ms, selectable in groups of four 0.2 ms 12.8 ms Single phase: 3 @ 100 khz & 3 @ 30 khz differential: 3 @ 80 khz & 3 @ 30 khz 500 m ; 50 m for technological functions 300 m ; For technological functions: No 4 ; 100 khz Pulse Train Output

6ES7214-1AG31-0XB0 Page 4 integrated channels (DO) 10 Functionality/short-circuit strength No ; to be provided externally Limitation of inductive shutdown voltage to L+ (-48 V) Switching capacity of the outputs with resistive load, max. 0.5 A on lamp load, max. 5 W Output voltage for signal "0", max. 0.1 V ; with 10 kohm load for signal "1", min. 20 V Output current for signal "1" rated value 0.5 A for signal "0" residual current, max. 0.1 ma Output delay with resistive load "0" to "1", max. 1 µs "1" to "0", max. 5 µs Switching frequency of the pulse outputs, with resistive load, max. 100 khz Cable length Cable length, shielded, max. 500 m Cable length unshielded, max. 150 m Analog inputs Integrated channels (AI) 2 ; 0 to 10 V Number of analog inputs 2 Input ranges Voltage Input ranges (rated values), voltages 0 to +10 V Input resistance (0 to 10 V) 100k ohms Cable length Cable length, shielded, max. 100 m ; twisted and shielded Analog outputs Cable length Cable length, shielded, max. 100 m ; Shielded, twisted wire pair

6ES7214-1AG31-0XB0 Page 5 Analog value creation Integrations and conversion time/ resolution per channel Resolution with overrange (bit including sign), max. 10 bit Integration time, parameterizable Conversion time (per channel) 625 µs Encoder Connectable encoders 2-wire sensor 1st interface Type of interface PROFINET Physics Ethernet Isolated Automatic detection of transmission speed Autonegotiation Autocrossing Functionality PROFINET IO Controller 2nd interface DP master Services S7 communication Communication functions S7 communication supported as server as client Open IE communication TCP/IP ISO-on-TCP (RFC1006) UDP Web server supported User-defined websites

6ES7214-1AG31-0XB0 Page 6 Test commissioning functions Status/control Status/control variable Variables Forcing Forcing Diagnostic buffer present Integrated Functions Number of counters 6 Counter frequency (counter) max. Frequency meter controlled positioning PID controller Number of alarm inputs 4 Number of pulse outputs 2 Limit frequency (pulse) Galvanic isolation Galvanic isolation digital inputs Galvanic isolation digital inputs between the channels, in groups of 1 Galvanic isolation digital outputs Galvanic isolation digital outputs between the channels between the channels, in groups of 1 Permissible potential difference between different circuits EMC Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters 100 khz 100 khz 500 V AC for 1 minute Interference immunity against discharge of static electricity Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 Test voltage at air discharge Test voltage at contact discharge No 500 V DC between 24 V DC and 5 V DC 8 kv 6 kv

6ES7214-1AG31-0XB0 Page 7 Interference immunity to cable-borne interference on the supply lines acc. to IEC 61000-4-4 Interference immunity on signal lines acc. to IEC 61000-4-4 Surge immunity on the supply lines acc. to IEC 61000-4-5 Immunity against conducted interference induced by high-frequency fields Interference immunity against high-frequency radiation acc. to IEC 61000-4-6 Emission of radio interference acc. to EN 55 011 Emission of radio interferences acc. to EN 55 011 (limit class A) Emission of radio interference acc. to EN 55 011 (limit class B) Degree and class of protection IP20 Standards, approvals, certificates CE mark CSA approval UL approval culus C-TICK FM approval Marine approval Ambient conditions Operating temperature ; Group 1 ; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 Min. -20 C max. 60 C vertical installation, min. -20 C vertical installation, max. 50 C horizontal installation, min. -20 C horizontal installation, max. 60 C Storage/transport temperature Min. -40 C

6ES7214-1AG31-0XB0 Page 8 max. 70 C Air pressure Operation, min. Operation, max. Storage/transport, min. Storage/transport, max. Relative humidity Operation, max. Vibrations Vibrations Operation, checked according to IEC 60068-2-6 Shock test checked according to IEC 60068-2-27 795 hpa 1080 hpa 660 hpa 1080 hpa 95 % ; no condensation 2G wall mounting, 1G DIN rail Climatic and mechanical conditions for storage and transport Climatic conditions for storage and transport Free fall Drop height, max. (in packaging) Temperature Permissible temperature range -40 C to +70 C Mechanical and climatic conditions during operation Climatic conditions in operation Temperature Min. -20 C max. 60 C Air pressure acc. to IEC 60068-2-13 Permissible air pressure Permissible operating height Pollutant concentrations Configuration ; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms 0.3 m ; five times, in dispatch package 1080 to 795 hpa -1000m to 2000m SO2 at RH < 60% without condensation S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free programming Programming language

6ES7214-1AG31-0XB0 Page 9 LAD FBD SCL Cycle time monitoring adjustable Dimensions Width 110 mm Height 100 mm Depth 75 mm Weight Weight, approx. 415 g Status Sep 3, 2012