Microwave Drawer : SMD2470AS, SMD3070AS Installation Manual

Similar documents
Right Side Trim (qty. 1) GWAKPB283MRF0

GE Monogram. Installation. Instructions. Microwave Oven. Under Cabinet Installation. and. JX827 Series Built-In Kit. Models.

Installation Instructions

Installation. Instructions. Built-In Microwave/Convection and Microwave Ovens. Models ZMC1095 JEB1095 JEB1055

Installation Instructions

Installation Instructions. Materials Needed. Parts Included. Tools You Will Need

GE Monogram. Installation. Instructions. 27" Built-In Ovens. Models ZEK757WW ZEK757BW ZEK737WW ZEK737BW

ELECTRIC RANGE INSTALLATION MANUAL. Please read these instructions thoroughly before installing and operating the range.

INSTALLATION INSTRUCTIONS 30" (76.2 CM) DROP-IN CERAMIC ELECTRIC RANGE

Installation Instructions

Installation Instructions

Life's Good. Please read these instructions thoroughly before installing and operating the range. \,J F% U ELECTICDOU LE. P/No.

Household Appliances. Over-the-Range Microwave. Installation Instructions. For Models: HMV9302, HMV9305, HMV9306, HMV9307

Installation Instructions

INSTALLATION GUIDE MICROWAVE OVEN UPMC3084ST. MFL _00

OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS

Robinson Bathroom Vanity

Monogram 36" Built-In Bottom-freezer Refrigerator

Installation Instructions

Installation Instructions For Slider Casement Air Conditioners

MONOGRAM 36" BUILT-IN FRENCH-DOOR BOTTOM-FREEZER

Robinson Bathroom Vanity

MICROWAVE HOOD COMBINATION INSTALLATION INSTRUCTIONS

A great addition to Sub-Zero's complete line of

BEFORE YOU BEGIN Read these instructions completely and carefully.

MONOGRAM 36" BUILT-IN BOTTOM-FREEZER REFRIGERATOR

MICROWAVE HOOD COMBINATION INSTALLATION INSTRUCTIONS

GE Monogram 36" Built-In All-Freezer

Installation Instructions

Installation Instructions

BEFORE YOU BEGIN Read these instructions completely and carefully.

GE Monogram 36" Built-In French-door Bottom-freezer

MICROWAVE HOOD COMBINATION INSTALLATION INSTRUCTIONS

Custom. Options Guide. and. Installation Instructions. GE Monogram 36" Built-In Refrigerators. Models: ZIS36NY ZISW36DY ZISB36DY

Installation Instructions

MICROWAVE HOOD COMBINATION INSTALLATION INSTRUCTIONS

Roveland Bathroom Vanity

IMPORTANT: Read and save these instructions.

Roveland Bathroom Vanity

Monogram 48" Built-In Side-by-Side Refrigerator

MONOGRAM 36" BUILT-IN ALL-REFRIGERATOR

IMPORTANT: Read and save these instructions.

MONOGRAM 36" BUILT-IN ALL-REFRIGERATOR

GE Monogram 36" Built-In Bottom-freezer Refrigerator

% website:

W INE S TORAGE INSTALLATION INSTRUCTIONS

MICROWAVE HOOD COMBINATION INSTALLATION INSTRUCTIONS

Sit N Sleep Bed 758/ /5401. Assembly Instructions - Please keep for future reference

INSTRUCTIONS. _rowave Hood Combination Combinaci6nMicroondasCampana

MICROWAVE HOOD COMBINATION INSTALLATION INSTRUCTIONS

BEFORE YOU BEGIN Read these instructions completely and carefully.

Over the Range Microwave Oven

MICROWAVE HOOD COMBINATION INSTALLATION INSTRUCTIONS

MICROWAVE OVEN INSTALLATION INSTRUCTIONS PLEASE READ AND SAVE THESE INSTALLATION INSTRUCTIONS.

READ BEFORE installing UNiT

MONOGRAM 36" INDUCTION COOKTOP

pottery barn kids OWEN LOFT BED Date: 2016-Jan.-23 Rev: Page 1 of 7

MONOGRAM 36" INDUCTION COOKTOP

Chapter 22 - Cabinets & Vanities

MICROWAVE HOOD COMBINATION INSTALLATION INSTRUCTIONS

Samuel 3FT Bunk Bed 183/ / /7877. Assembly Instructions - Please keep for future reference

SAN DIEGO - Corner TV Unit

Steele TV Stand Stock # BH

Installing flat panels on the MPL15 wall mount

Installation Instructions. Vista R Door I001 April Design with Anthony

MONOGRAM 48" BUILT-IN SIDE-BY-SIDE REFRIGERATOR

PRODUCT MANUAL 5-IN-1 MITER SAW STATION *SAVE THIS MANUAL FOR FUTURE REFERENCE

Owner s Manual & Safety Instructions

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

! WARNING: FALL HAZARD - To prevent death or serious injury from

MICROWAVE HOOD COMBINATION SAFETY. Your safety and the safety of others are very important.

installation instructions For Slider Casement Air Conditioners

To prevent accidents and damage please read these instructions before installation or use. Installation Instructions

YES 12 Charging Wall Cabinet for Mini-laptops

2275DWRR Refrigerator Drawer

E R I E S I O N G U E A L L A T I D II N S T

MM750 Installation Instructions

SAN DIEGO - TV Unit. Assembly Instructions - Please keep for future reference 389/6620

2075DWRWC Drawer Model Wine Captain

Install Instructions READ THIS FIRST BEFORE UNPACKING CABINET WARNING: WARNING: Do not leave children unattended near cabinets.

MODEL SETUP & OPERATION MANUAL DOVETAIL JIG FEATURES SPECIFICATIONS

DUST COLLECTOR 70 GALLON, 2 HP

Yes 20 Charging Wall Cabinet for Tablets

101B, 210X, ELM, VSTB Installation Manual

INSTALL INSTRUCTIONS WELCOME TO THE NEWAGE PERFORMANCE CABINETRY SERIES NEWAGE STEEL WELDED CABINETRY

Wall Mount Dust Collector 650 CFM Instructions

Installation Manual. A Brighter Future. Technical Support ext 2

Install Guide. view our Install video guide online

High-Speed Oven. E30SO75ESS designer series

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

GE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -

Dalton Park 5pc Dining Set

I 1. icrowave Hood Combination Combinaci6n icroondascampana

Cabinetry Installation

Santa Fe Kitchen Cart with Metal Shelves Stock # SFKCWMS

" BASE CABINET

Closet Carousel Installation Instructions. Models TKA 5 Through TKA 14 Equipped with Footswitch Controls

MSP-DCCLFSD LCD Flat Screen Swing-Down Mount

Yes 20 Charging Wall Cabinet for Tablets

BEFORE YOU BEGIN Read these instructions completely and carefully.

Transcription:

SPL WRNN Microwave rawer : SM2470S, SM3070S nstallation Manual NSTLLTON N SRV MUST PRORM Y QUL NSTLLR. MPORTNT: SV this installation manual OR LOL LTRL NSPTOR S US. R N SV TS NSTRUTONS OR UTUR RRN. learances and imensions or STY ONSRTONS do not install drawer in any combustible cabinetry, which is not in accord with the stated clearances and dimensions on pages 2-5. See igure 1 (for 24") or igures 4 and 5 (for 30"). Unpacking your microwave drawer Remove all packing materials from inside the Microwave rawer. O NOT RMOV T WVU OVR, which is located on the top of the Microwave rawer. Remove the feature sticker, if there is one. heck the drawer for any damage, such as misaligned or bent Sealing surface Waveguide cover drawer, damaged drawer seals and sealing surfaces, broken or loose Microwave rawer guides and dents inside the cavity or on the front side of the drawer. f there is any damage, do not operate the Microwave rawer and contact your dealer or a SRP UTORZ SRVR. mportant notes to the installer Sealing surface Oven cavity Read all of the nstallation Manual before installing the Microwave rawer. Remove all packing material before connecting the electrical supply. Observe all governing codes and ordinances. e sure to leave these instructions with the consumer. mportant notes to the onsumer Keep this manual with your Operation Manual for future reference. s when using any microwave oven generating heat, there are certain safety precautions you should follow. These are listed in the Operation Manual. Read all and follow carefully. e sure your Microwave rawer is installed and grounded properly by a qualified installer or service technician. mportant Safety nstructions f the information in this manual is not followed exactly, a fire or electrical shock may result that could cause property damage, personal injury or death. To reduce the risk of tipping, the Microwave rawer must be secured by a properly installed nti-tip block. This Microwave rawer must be electrically grounded in accordance with local codes. Make sure the wall coverings and the cabinets around the Microwave rawer can withstand the heat generated by the Microwave rawer. Never leave children alone or unattended in the area where a Microwave rawer is in use. Never leave the drawer open when the microwave is unattended. Stepping, leaning or sitting on the drawer may result in serious injuries and can also cause damage to the Microwave rawer. o not use the Microwave rawer as a storage space. This creates a potentially hazardous situation. heck that the time-of-day is in the display. f not, touch STOP/LR to prevent unintended use. 1

learances and imensions imensions that are shown in igure 1 (for 24") or igures 4 and 5 (for 30") must be used. iven dimensions provide minimum clearance. Locate electrical outlet in the shaded area in the upper left-hand corner of the cutout. See igure 9. ontact surface must be solid and level. Pay special attention to the floor on which the Microwave rawer will sit. The floor of the opening should be constructed of plywood strong enough to support the weight of the oven (about 100 pounds). heck location where the Microwave rawer will be installed for proper electrical supply. Your oven can be built into a cabinet or wall by itself or under a gas or electric wall oven. e sure that the clearance of the floor between the wall oven and the microwave drawer is a minimum of 2-inches. The microwave interior will easily accommodate a 9" x 13" oblong dish or a bag of microwave popcorn. The oven can also be mounted flush. Please see instructions for flush mounting included with the lush Mount eflector vent. 24" Microwave rawer Measurements M L K P N igure 2 igure 1 O utout imension 22 1 /8" x 15 9 /16". 6". Suggested electrical outlet location*. nti-tip block. 5". 3-1/2". 4". 22-1/8" opening. 14-13/16" to bottom of nti-tip block. llow 7/8" overlap. 23-1/2" minimum depth K. llow 3/16" overlap L. 36" countertop height M. llow 7/16" minimum overlap N. loor must support 100 lb O. 24" cabinet minimum P. 15-9/16" opening 2. 21-5/8". 4-11/16". 1-3/4". 21-7/8". 23-7/8". 15-7/8". 14-19/32". 1-9/64" door thickness. 15" auto drawer opening. 4" igures 1 and 2 contain many Microwave rawer measurements for reference when planning the drawer s location. This Microwave rawer can be installed below any electric or gas wall oven. * an also be installed using an electrical outlet in an adjacent cabinet within the area where the provided electrical cord can reach. Power cord access hole in cabinet should be a minimum 1 1/2" diameter hole and deburred of all sharp edges. MPORTNT lways allow sufficient power cord length to the electrical outlet to prevent tension. lways check electrical codes for requirements.

This drawing represents a typical standard cabinet. f installed in custom cabinets with extended counter tops, take into account visibility and access to controls. See igure 3. Move oven location downward for extended countertops xtended countertops igure 3. 25". 1/2". 15-7/8". 36". ontrol panel shown in open position. 24". 34-1/2" 3

30" Microwave rawer Measurements igures 4, 5 and 6 contain many Microwave rawer measurements for reference when planning the drawer s location. This Microwave rawer can be installed below any electric or gas wall oven. * an also be installed using an electrical outlet in an adjacent cabinet within the area where the provided electrical cord can reach. Power cord access hole in cabinet should be a minimum 1 1 /2" diameter hole and deburred of all sharp edges. MPORTNT lways allow sufficient power cord length to the electrical outlet to prevent tension. lways check electrical codes for requirements. utout imension 28 7 /16" x 15 9 /16" M N M K P O Q L. 84" wall cabinet. Optional wall oven cutout illustrated in sketch. Suggested electrical outlet location*. 6". nti-tip block. 3-1/2". 5". 4". 2" minimum. 28-7/16" opening K. llow 3/16" overlap L. 14-13/16" to bottom of nti-tip block M. llow 3/4" overlap N. 23-1/2" minimum depth O. 15-9/16" opening P. llow 7/16" overlap Q. loor must support 100 lb R. 30" cabinet minimum R igure 4 4

L M K P N utout imension 28 7 /16" x 15 9 /16". 6". Suggested electrical outlet location*. nti-tip block. 5". 3-1/2". 4". 28-7/16" opening. 14-13/16" to bottom of nti-tip block. llow 3/4" overlap. 23-1/2" minimum depth K. llow 3/16" overlap L. 36" countertop height M. llow 7/16" overlap N. loor must support 100 lb O. 30" cabinet minimum P. 15-9/16" opening igure 5 O. 21-5/8". 4-11/16". 1-3/4". 21-7/8". 29-7/8". 15-7/8". 14-19/32". 1-9/64" door thickness. 15" auto drawer opening. 4" igure 6 5

This drawing represents a typical standard cabinet. f installed in custom cabinets with extended counter tops, take into account visibility and access to controls. See igure 7. Move oven location downward for extended countertops xtended countertops igure 7. 25". 1/2". 15-7/8". 36". ontrol panel shown in open position. 24". 34-1/2" 6

nti-tip LOK NORML NSTLLTON STPS nti-tip LOK nstallation nstructions To reduce the risk of tipping of the drawer, the nti-tip block must be properly installed located 14 13 /16-inches above the floor on which the Microwave rawer will sit. The 6-inch nti-tip block must be provided by the installer. See igures 1, 4 and 5. The nti-tip block prevents serious injury that might result from spilled hot liquids. f the Microwave rawer is ever moved to a different location, the nti-tip block must also be moved and installed. When installed to the wall, make sure that the screws completely penetrate the dry wall and are secured in wood or metal so that the block is totally stable. When fastening, be sure that the screws do not penetrate electrical wiring or plumbing. igure 8 lectrical Outlet The electrical requirements are a 120 volt 60 z, only, 15 amp. or more protected electrical supply. t is recommended that a separate circuit serving only this appliance be provided. The drawer is equipped with a 3-prong grounding plug. t must be plugged into a wall receptacle that is properly installed and grounded. Should you only have a 2-prong outlet, have a qualified electrician install a correct wall receptacle. Note: f you have any questions about the grounding or electrical instructions, consult a qualified electrician or service person. * an also be installed using an electrical outlet in an adjacent cabinet within the area where the provided electrical cord can reach. lways check electrical codes for requirements. igure 9 rounding nstructions This appliance must be grounded. The Microwave rawer is equipped with a cord having a grounding wire with a grounding plug. t must be plugged into a wall receptacle that is properly installed and grounded in accordance with the National lectrical ode and local codes and ordinances. n the event of an electrical short circuit, grounding reduces risk of electric shock by providing an escape wire for the electric current. mproper use of the grounding plug can result in a risk of electric shock. o not use an extension cord. f the power supply cord is too short, have a qualified electrician or serviceman install an outlet near the appliance. 3-Prong plug rounding pin 3-Prong receptacle rounded receptacle box 7

rawer nstallation 1. Place the drawer adjacent to the wall or cabinet opening. Plug the power supply cord into the electrical outlet. 2. arefully guide the drawer into the prepared opening. void pinching the cord between the oven and the wall. 3. Slide the drawer all the way until the mounting flange is flush with the face of the cabinet. See igure 10. 4. Open the drawer. Using the 4 holes on the drawer as a template, pre drill the cabinet using a 1 /16" bit. See igure 10. 5. Secure the drawer with the 4 screws supplied. See igure 10. Parts supplied igure 10 Mounting flange 4 Screws igure 10 Model and serial number location The name plate includes model and serial number. Open the Microwave rawer fully. The label is beyond the back wall of the microwave cavity facing up from the flat surface. are, cleaning and maintenance Refer to the Operation Manual for cleaning instructions. efore you call for service Read the OR YOU LL and operating instruction sections in your Operation Manual. t may save you time and expense. The list includes common occurrences that are not the result of defective workmanship or materials in this range. Refer to the warranty in your Operation Manual for Sharp s toll-free service number and address. Please call or write if you have inquiries about your microwave product and/or need to order parts. TNS539MRR0 SRP LTRONS ORPORTON 1 Sharp Plaza, Suite 1 Mahwah, New ersey 07495-1123 1-800--SRP (237-4277) 8 eb 10, 2015

24" lush Mount eflector Vent: SKM240S NSTLLTON NSTRUTONS mportant notes to the installer Read all of the nstallation Manual that is included with the Microwave rawer before installing in the flush mount configuration. Observe all governing codes, ordinances, and safety instructions. e sure to leave these instructions with the consumer. Parts includes: Qty. 1 2 PR-019MRP0 lush Mount eflector Vent LX-Z055MR0 Mounting screws Part number 1. Prepare cabinet opening as shown in igures 1, 2, 2, 2. L K M N Note: the face of the shelf must sit 1 3 /4" (44.45 mm) back from the face of the cabinet. shelf face O cabinet face. 6" (152.40 mm). Suggested electrical outlet location. nti-tip block. 5" (127 mm). 3-1/2" (88.90 mm). 4" (101.60 mm). 24-3/16" (614.35 mm) minimum 24-1/2" (622.3 mm) maximum. 14-13/16" (376.24 mm) to bottom of nti-tip block. 1-1/16" (26.97 mm). 23-1/2" (596.90 mm) minimum depth K. 22" (558.8 mm) L. 1-3/4" (44.45 mm) M. 16-7/8" (428.62 mm) opening N. loor must support 100 lb (45.4 kg) O. 1-3/4" (44.45 mm) igure 1 nti-tip block Mounting cleat. 22" (558.8 mm) mounting cleat opening width. 1/4" (6.35 mm). 1-1/16" (26.97 mm) rawer face abinet face L Top view Note: the mounting surface of the finished cleat must sit 1 1 /16" (26.97 mm) back from the face of the cabinet [pushing the face of the drawer out 1 /4" (6.35 mm)]. igure 2 1 TNS541MRR1

No oven 3. Place the drawer adjacent to the wall or cabinet opening. Plug the power supply cord into the electrical outlet. Suggested electrical outlet location nti-tip block 4. arefully guide the drawer into the prepared opening. void contact with the sides of the cutout opening and also pinching the cord between the oven and the wall. 5. Slide the drawer all the way back until the mounting flanges touch the cleats mounted in the cabinet opening. 6. Open the drawer. Using the 4 holes on the drawer as a template, pre drill the cabinet using a 1/16 (1.57 mm) bit. See igure 4. igure 2 ront view. 22" (558.8 mm) mounting cleat opening width. 24-3/16" (614.35 mm) minimum 24-1/2" (622.3 mm) maximum flush opening width. 3/4" (19.05 mm) shelf Move oven location downward for extended countertops for better viewing angle. 16 7 /8" (428.62 mm) flush opening height 3/4" (19.05 mm) shelf nti-tip block igure 4 7. Secure the drawer with the 4 screws supplied. Mounting flange ront face of cabinet 1 3 /4" (44.45 mm) front face of shelf igure 2 Side view 2. nstall deflector as shown in igure 3. Shelf detail showing the deflector vent during installation. Position deflector vent and mark holes. Pre drill using a 1 /16" (1.57 mm) bit before mounting. igure 3 Shelf detail showing the deflector vent installed. igure 3 2

30" lush Mount eflector Vent: SKM300S NSTLLTON NSTRUTON mportant notes to the installer Read all of the nstallation Manual that is included with the Microwave rawer before installing in the flush mount configuration. Observe all governing codes, ordinances, and safety instructions. e sure to leave these instructions with the consumer. Parts includes: Qty. 1 2 PR-020MRP0 lush Mount eflector Vent LX-Z055MR0 Mounting screws Part number 1. Prepare cabinet opening as shown in igures 1, 2, 2, 2. igure 1 L K M N Note: the face of the shelf must sit 1 3 /4" (44.45 mm) back from the face of the cabinet. shelf face O cabinet face. 6" (152.40 mm). Suggested electrical outlet location. nti-tip block. 5" (127 mm). 3-1/2" (88.90 mm). 4" (101.60 mm). 30-5/16" (769.92 mm) minimum 30-5/8" (777.87 mm) maximum. 14-13/16" (376.24 mm) to bottom of nti-tip block. 1-1/16" (26.97 mm). 23-1/2" (596.90 mm) minimum depth K. 28-1/2" (723.9 mm) L. 1-3/4" (44.45 mm) M. 16-7/8" (428.62 mm) opening N. loor must support 100 lb (45.4 kg) O. 1-3/4" (44.45 mm) nti-tip block Mounting cleat. 28-1/2" (723.9 mm) mounting cleat opening width. 1/4" (6.35 mm). 1-1/16" (26.97 mm) rawer face abinet face L Top view Note: the mounting surface of the finished cleat must sit 1 1 /16" (26.97 mm) back from the face of the cabinet [pushing the face of the drawer out 1 /4" (6.35 mm)]. igure 2 3

No oven 3. Place the drawer adjacent to the wall or cabinet opening. Plug the power supply cord into the electrical outlet. Suggested electrical outlet location nti-tip block 4. arefully guide the drawer into the prepared opening. void contact with the sides of the cutout opening and also pinching the cord between the oven and the wall. 5. Slide the drawer all the way back until the mounting flanges touch the cleats mounted in the cabinet opening. 6. Open the drawer. Using the 4 holes on the drawer as a template, pre drill the cabinet using a 1/16 (1.57 mm) bit. See igure 4. igure 2 ront view. 28-1/2" (723.9 mm) mounting cleat opening width. 30-5/16" (769.92 mm) minimum 30-5/8" (777.87 mm) maximum flush opening width. 3/4" (19.05 mm) shelf Move oven location downward for extended countertops for better viewing angle. 16 7 /8" (428.62 mm) flush opening height 3/4" (19.05 mm) shelf nti-tip block igure 4 7. Secure the drawer with the 4 screws supplied. Mounting flange ront face of cabinet 1 3 /4" (44.45 mm) front face of shelf igure 2 Side view 2. nstall deflector as shown in igure 3. Shelf detail showing the deflector vent during installation. Position deflector vent and mark holes. Pre drill using a 1 /16" (1.57 mm) bit before mounting. igure 3 Shelf detail showing the deflector shield installed. igure 3 1 Sharp Plaza Suite 1, Mahwah, New ersey 07495-1123, US 1-800--SRP (237-4277) 335 ritannia Road ast, Mississauga, Ontario, L4Z 1W9, anada 4