Insertion Transducer On-line Install Instruction

Similar documents
...thoroughly tried and tested!

MALEKO WALL-MOUNT FAUCET INSTALLATION

For a later setting up of a measuring place

LATTIMORE SHOWER SET INSTALLATION

Multi-Bowl Applications

Mueller Gas Products. Mueller H17800 Curb Stop Tee No Blo Curb Stop Tee Weld x Weld 1440 PSI

BALANTINE WALL-MOUNT FAUCET INSTALLATION

Automated Tiki Torch Installation Instructions

MUELLER E-5TM. and D-5TM. Drilling Machines. Reliable Connections. E-5 General Information 2. D-5 General Information 3. Operating Instructions 4-5

Instruction manual. Drilling jig. For a later setting up of a measuring place V2_01_2009

WILLIS WALL-MOUNT FAUCET INSTALLATION

CALLAS THERMOSTATIC SHOWER SET

Traditional Wall Mounted Potfiller

ROTUNDA WALL-MOUNT FAUCET INSTALLATION

Pressure Vessel Assembly Instructions

Installation and Operating Instructions

MUELLER GAS. DH-5 Drilling Machine. For use on 1 1 /2 & 2 Line Stopper Fittings. Reliable Connections. General Information 2

Flange Dimensions Class 125 Bronze Flange Dimensions Class 300 Bronze Flange Dimensions Class 150 Bronze Flange Dimensions

STEWARD ECO T01-B INSTALLATION INSTRUCTIONS L URINAL (REAR INLET) K-4986T-ER( ) , 2010 Copyright Kohler China Ltd.

NABTEB Past Questions and Answers - Uploaded online PAST QUESTIONS AND ANSWERS GENERAL METAL WORK MAY/JUNE 2009

HBS-AP ASSEMBLING INSTRUCTIONS

DETAILED ILLUSTRATION

SHELTON THERMOSTATIC SHOWER PANEL

ONASSIS SHOWER SET INSTALLATION

This specification describes the minimum requirements for piping systems for the following service:

Riser Extension INSTALLATION GUIDE 40100AX35 / 40100AX18. Manual 40100X35-8

Acrylic Claw Foot Tub

Section COUPLINGS AND COUPLING ADAPTERS. This Section covers couplings and coupling adapters for ductile iron and steel pipe.

CAELI THERMOSTATIC SHOWER PANEL

F-5-1a. Concrete Bollards (Detail 1 of 2) WEIGHT: 166kg. WEIGHT: 227kg. WEIGHT: 113kg. WEIGHT: 212kg

INSTRUCTIONS FOR AIRFLEX 36WCBEP/36WCSEP WEAR PLATE REPLACEMENT USING GASKET SEALING TAPE

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extention Sections. Reliable Connections

T : F : Revised June 2013

ANSI ORIFICE FLANGES METAL-KOREA

25 TONNE HYDRAULIC PRESS MODEL NO: AHP 26

HYDRO-TOWER INSTALLATION INSTRUCTIONS

EXIRA SHOWER SET INSTALLATION

This specification describes the minimum requirements for piping systems for the following service:

This specification describes the minimum requirements for piping systems for the following service:

Wire and pipe drawing

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extension Sections. Reliable Connections

B-Too Drilling and Tapping Machine Instruction and Maintenance Manual

Frameless Inline Door QCI5250

INSTALLATION GUIDELINES

HYDRO-TOWER INSTALLATION INSTRUCTIONS

Mould Precision Co., Ltd

Operating instructions OI/FPD350-EN Rev. H. FPD350 Torbar Averaging pitot tubes

installation instructions WC Frame 820mm with Dual Flush Cistern _INST

UL / FM E-1 FIRE PROTECTION PRODUCTS INDICATOR POST FEATURES. *Applies to "ORDER LENGTH" codes B through F; code A has 22" adjustment.

Frameless Inline Door QCI5254

FRAMELESS DOOR / PANEL WITH WALL MOUNT HINGES QCI5274

PURESTREAM SYSTEM - ASSEMBLY GUIDE

BURRI public elements AG BURRI public elements Deutschland GmbH

SECTION MANHOLES

SYGEF Standard SYGEF Plus PVDF Flanges

F-3200 SERIES Inline Electromagnetic Flow Meter Wiring Instructions

One-sided rack, hot-dip galvanized Space between bicycles 350 mm length approx.kg Part-No. Two-sided rack, hot-dip galvanized

.1 Materials and installation for steel piping, valves and fittings for hydronic systems in building services piping..2 Related Sections.

Operating, Servicing, and Safety Manual Model # 100 Standard Hydraulic Tubing Notcher Model #100-U Heavy Duty Hydraulic Tubing Notcher

Mould Precision Co., Ltd

Simplex Baseboard System Baseboard System

Emission-Pak Assemblies

5.1 MUELLER CORPORATION VALVES. MUELLER 300 Ball Type Corporation Valves

Frameless Inline Door With Return QCI5263

Made in USA. Valves VALVES FOR INSTRUMENTATION & PROCESS SYSTEMS

Advancements in Clamp-on Ultrasonic Flow Measurements Biosolids Workshop December 1 st 2016

Cylinder Head Bolt Threads Damaged (2AZ-FE)

OPERATION AND MAINTENANCE INSTRUCTIONS AVK UNDERGROUND FIRE HYDRANT

Frameless Heavy Glass Door with Header

MUELLER GAS. DH-5/EH-5 Drilling. Reliable Connections. DH-5 Drilling Machine General Information 2. EH-5 Drilling Machine General Information 3

This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface.

Welded connections Welded connections are basically the same design in AISI as in AISC. Minor differences are present and outlined below.

The Virgo/Libra Steam Engine

HANDRAIL HEIGHT PER LOCAL CODE AUTORITY


Stair Mounting Kit. Installing safety gates in modern homes can be very challenging, especially for stairs.

EMO. Service Instruction. created by Frank Weithöner. Table of contents: Special Tools Assembling Mixing Chamber

KTM-16/20 TECHNICAL DATA

Small Flush Wood Flue Adapter Installation Instructions (SKU )

THE INSTALLING INSTRUCTION FOR CONCEALED TANK

Tuf-Lite III Fans 5000K Series Hub

Always be your solar support

Ford Drilling Machine

Zero Point Clamping System. ZERO lock BALL lock

IIHS Side Impact Outrigger

Lockformer / 16 Gauge Speednotch

WILLIS WIDESPREAD FAUCET

Fisher 667 Diaphragm Actuators Size 80 and 100

Tooling Approving Report

Ti-Color STAINLESS STEEL HANDRAIL

w w w. h d o n l i n e s h o p. d e AUTOMATIC COMPRESSION RELEASE TOOL GENERAL INSTALLATION -J04654 REV Kit Number Models

25000 Series Lo-T TM Butterfly Control Valve Instructions

Spinnaker Launching Bag Kit

Figure 11 Flange Adapter and Back-Up Ring

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

Pump Replacement Manual. Bill Wallace by Wallace Marine Services, Inc.

H O O P RAC K. Simple Security

Bodyspray INSTALLATION INSTRUCTIONS

thoroughly tried and tested! EWE Tapping Valves A single system for all types of pipes

Lengths [7] Ø.50 [13] [7] [13]

Transcription:

LOGO Insertion Transducer On-line Install Instruction Shanghai Dynameters Co., Ltd www.dynameters.com

Insertion Transducer Installation Manual Installation steps 1. Locate Installing point 2. Weld mounting base 3. Place Gasket ring 4. Screw ball valve on 5. Drill hole 6. Screw transducer on 7. Fix transducer

11 Locate the Installing Point on Pipe First mark the installing point on pipe, as showed bellow: Top view: Upstream transducer installing point point Input proper parameters in in M11 to to M24,M25 will display transducer spacing value L. L. L Select the optimum location, ensure enough straight pipe length, usually upstream >10D and downstream > 5D (where D is the inner diameter of the pipe.) Downstream transducer Installing point point

22 Weld Mounting Base Insert a screw plug into mounting base before welding to to avoid deformation. Weld mounting base Mounting base base welded Mounting base material SS304

33 Place the Gasket Ring PTFE Gasket ring on Mounting Base

44 Screw Ball Valve onto the Mounting Base Screw the ball valve tightly onto the base, and keep it it open for drilling.

55 Drill Hole Drilling pole Hot-taped; Watertight drill bit Electronic hand drill Choose different drill bit bit according to to pipe material

55 Drill Hole Outer thread Inner thread + Drilling pole Ball valve Open ball valve, insert the drilling pole into the ball valve and then screw them together tightly.

55 Drill Hole 1.Screw the drilling pole onto the ball valve. Insert the drilling pole into the ball valve, screw them together tightly, then open the ball valve. 2.Drilling Hole When liquid ejects out, it means you finish hole drilling. Then pull out the drilling pole slowly and shut down the ball valve at proper time. Never stand against liquid ejection direction to avoid injury.

66 Screw the Transducer on Screw Screw the the transducer in. in. Transducer position as as showed: Insert and screw the transducer on on and open the ball valve at at proper time to to prevent liquid ejection. L=A-B (Let C=0) In this formula: L---Mounting height (mm) A--Transducer length (mm) B---Pipe wall thickness (mm)

77 Fix Transducer Screw this bush tightly to to prevent the liquid leak and fix the transducer.

88 Install the Other Transducer in the Same Way Repeat above steps to to install the the other transducer Effect Figure Top view

Principle of Operation Z-method Upstream transducer Ultrasonic signal signal Ensure the two wire holes face up or face down at the same time, and both of them absolutely parallel. Downstream transducer Wiring Wiring hole hole

Check Signal Quality 1. Check M90: displays signal quality value Q>60. The higher the better. Menu 01 2. Check M91: displays the transit time ratio within the range 97%-103%. NOTE: when the time ratio displays in M91 exceeds the range of 100±3%, micro-adjust the transducer. Menu 01 Menu 01

Installing Hoop for Cement Pipe It It need need to to install a weldable (usually carbon steel) hoop if if pipe pipe material is is cement, ductile iron iron or or other unweldable material.

LOGO Shanghai Dynameters Co., Ltd www.dynameters.com