TRFWL. Autostart Inc Rue Paré Mont-Royal, Québec Canada, H4P 2M2 EZSNAH2503

Similar documents
Chapter I - Federal Communications Commission Subchapter A - General Part 15 - Radio Frequency Devices Subpart C - Intentional Radiators

Glen Westwell, Wireless Technologist

Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2

Test report TRFWL. Lotek Wireless Inc. SRX800 SRX A-SRX800. RSS-215 Issue 2, June Date of issue: July 11, 2014.

Test Report: 4R Champlain Street Dieppe, New-Brunswick Canada E4P 8L6. Model Number: Verification

Test Report: 5R Champlain Street Dieppe, New Brunswick Canada E1A 1P6. Model Number: Verification

Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2

FCC CERTIFICATION TEST REPORT

TRANSMITTER MODEL: KAS-2030M

Operation in the MHz, MHz, and MHz

EMC Test Report. Tested by: Jeremy O. Pickens, Senior EMC Engineer. Reviewed by: David Schramm, EMC/RF/SAR/HAC Manager

Title: Test on 5.8 GHz Band Outdoor WiFi (802.11b/g) Wireless Base Station

Description of Test Facility

Quality Auditing Institute # Schoolhouse Street, Coquitlam, BC, V3K 4X9, Canada. ISO Accreditation:

TEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C

F2 Labs Peters Road Middlefield, Ohio United States of America

1 Hines Rd. Ottawa, Ontario K2K 3C7. PCS Low Power Repeater. 303 River Road, R.R. 5 Ottawa, Ontario K1V 1H2. Authorized By:

R. Grant, Wireless Group Manager

Test report TRFWL. Texas Instruments Inc. CC3100 Booster-pack CC3100MODR11MAMOB ETSI EN V1.8.1 ( )

OUTDOOR SOUND MODULE/TRANSMITTER MODEL: THE BANDIT

FCC PART TEST REPORT. Weccan Industrial Limited

FCC Test Report. : ASE Group 4F,No 133, Sec 4, Mingsheng E Rd, Songshan Dist, Taipei, Taiwan

XBee Series 2 OEM RF Module Model No.: XBEE2 FCC ID: OUR-XBEE2. Applicant: MaxStream, Inc. 355 South 520 West Suite 180 Lindon, UT 84042

7. Transmitter Radiated Spurious Emissions and Conducted Spurious Emission

ECHOSTAR 54.0 BRISBANE VOICE REMOTE 2017 MODEL: URC-2027BC0-R

T E S T - R E P O R T. No for. FHS 20/21 Typ 2 ASK 315 MHz. Remote Control Transmitter

Test Report. ASSA ABLOY Hospitality AS Anolitveien 1-3, 1400 Ski, Norway. ASSA ABLOY Hospitality AS Anolitveien 1-3, 1400 Ski, Norway

FCC PART 95 MEASUREMENT AND TEST REPORT. Powerwerx, Inc.

Via del Carroccio, 4 I Biassono (Italy) TRFFCC

Test report no. : Item tested : LCU Type of equipment : RFID Transceiver Module FCC ID : Y7V-LCU6333

APPLICATION FOR CERTIFICATION On Behalf of Futaba Corporation Radio Control Model No.:T10CG-2.4G FCC ID:AZPT10CG-24G Brand : Futaba

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm)

Table of Contents 1. GENERAL INFORMATION SYSTEM TEST CONFIGURATION CONDUCTED EMISSIONS TEST RADIATED EMISSION TEST...

STC Test Report. Date : Page 1 of 13 No. : HM161169

Revision history. Revision Date of issue Test report No. Description KES-RF-14T0042 Initial

FCC Report for Parts ,

TEST REPORT SZEM CR

TEST REPORT. Issued for: ShenZhen MYGT Co.,LTD D3 Tongfuyu Industrial Area Community of Shajing Town, Baoan, Shenzhen, China.

Advanced Compliance Solutions, Inc FAU Blvd, Suite 310 Boca Raton, Florida (561)

TEST REPORT. Issued for: RUIMA INTERNATIONAL(HK)INDUSTRIAL CO.,LIMITED NO.19 Ruixiang Road, Xinhua Industrial Zone, Huadu District, Guangzhou China

TEST REPORT. Test Report No. : UL-RPT-RP JD02A V3.0. Date of Issue: 06 October 2017

FCC Test Report. Report No.: AGC FE02 CLIENT : INNOVATIVE CONCEPTS AND DESIGN LLC. Attestation of Global Compliance (Shenzhen) Co., Ltd.

FCC RADIO TEST REPORT FCC 47 CFR PART 15 SUBPART C

Version TEST REPORT NO. DATE DESCRIPTION

TEST REPORT FROM RFI GLOBAL SERVICES LTD

FCC 47 CFR Part 15, Subpart B Verification ICES-003 Issue 4 February 2004 EN 55022: 2010 EN : A1: A2: 2009 EN : 2008

Page 1 of 51 Report No.: T TEST REPORT FCC ID: 2AGJ5WAP-30. In Accordance with: FCC PART 15, SUBPART C : 2015 (Section 15.

TEST REPORT. Issued for:

FCC 47 CFR Part 15, Subpart B Verification ICES-003 Issue 4 February 2004 EN 55022: 2010 EN : A1: A2: 2009 EN : 2008

Measurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob

F2 Labs Peters Road Middlefield, Ohio United States of America

1/41 IC: 109U-89FT7100

EMI T E S T R E P O R T

Test. Report. Manufacturer. Model No. FCC ID. Technology. and. 1. This. 3. This. pp John Newell. as UL. Date of Issue: 28 May 2013.

FCC TEST REPORT. ADDRESS: #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

Pass* * In the configuration tested, the EUT complied with the standards specified above.

TEST REPORT. Report Number: MIN-001 Rev 1.1 Project Number: G Testing performed on the 2102 IPG

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Trade Name : Activision. Model Number: / FCC ID: XLU

8370 Court Avenue, Suite B-1 Ellicott City, Maryland (410) FCC CERTIFICATION

TEST REPORT. Building 6, XinXinTian Industrial Park, XinSha Road, ShaJing, Baoan District, ShenZhen, China. Shenzhen Innokin Technology Co.

TEST REPORT. Test Report No. : UL-RPT-RP JD03A V3.0. Date of Issue: 14 September pp John Newell Quality Manager, UL VS LTD

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-GEN AND RSS-210 CERTIFICATION TEST REPORT FOR BROADCOM BLUETOOTH MODULE MODEL NUMBER: BCM92046MD

SILENT PARTNER Model No.: SCOOP FCC ID: WXMSCOOP. In Accordance With

ENGINEERING TEST REPORT

TEST REPORT. Issued for: Marvelmind Robotics Lugovaya str., 4 bld 5 room 17, Skolkovo Innovation Center, Moscow, , Russian Federation

TEST REPORT. Issued for: TICATAG 4 rue Louis de Broglie LANNION FRANCE. Issued By:

FCC AND IC CERTIFICATION TEST REPORT

FCC 47 CFR PART 15 SUBPART C ANSI C63.4: 2009

UL Japan, Inc. Head Office EMC Lab Asama-cho, Ise-shi, Mie-ken JAPAN Telephone : Facsimile :

Certification Test Report

Compliance Engineering Ireland Ltd

Test Report. Bluetooth Transceiver in UPCS Base Station. Panasonic Corporation of North America

FCC Verification TEST REPORT

Martec/Wayne Dalton Transmitter Model(s): 3977

FCC 47 CFR PART 15 SUBPART C CERTIFICATION TEST REPORT FOR. Bluetooth Remote Control for Video Set Top Box MODEL NUMBER: IPRC1000 FCC ID: 2ABTE-L3YJC9

COMCAST XFINITY HOME MOTION SENSOR MODEL: URC4470BC0-X-R

ELECTRICAL TESTING ACCORDING TO: FCC 47CFR part 15 subpart C (DTS) and subpart B FOR:

FCC PART TEST REPORT. Zhejiang Flashforge 3D Technology CO., Ltd

TRANSMITTER Model: TX24

Page 2 of 20. Table of contents. Page

Medtronic MiniMed TEST REPORT FOR. GST3 Glucose Sensor Transmitter, MMT-7763A. Tested To The Following Standards:

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 CERTIFICATION TEST REPORT FOR. Dolphin CT50

Measurement of RF Interference from a Canopy 900MHz Access Point and Subscriber Module Using A Yagi Antenna

EMI -- T E S T R E P O R T

REPORT REVISION HISTORY...

Test Report. FCC Part 15, Subpart C, Section Industry Canada RSS-210, Issue 7

FCC CFR47 Part 15 Subpart C IC RSS-247 Certification Test Report

For. Unit D16/F. should not use it to claim FCC ID: 2AAIN-MNGLOS

TEST REPORT FCC ID: 2ADMF-HC06. : bluetooth module keyes HC-06, keyes hc-05, FUNDUINO HC-06, FUNDUINO hc-05

FCC PART & IC RSS GHz FHSS TEST REPORT

EMI T E S T R E P O R T

TEST REPORT. Table of Contents

Test Report Version. Test Report No. Date Description. DRTFCC Sep. 12, 2014 Initial issue

CERTIFICATION TEST REPORT

Total number of pages : 116

Date: ESPOO Page: 1 ( 10) Appendices - Transceiver. SATELLINE-EASy Pro 35W SATEL-TA18 SATEL Oy, Finland

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Mad Catz Inc. Model Number: 90630C FCC ID: P25S790630AC

Radiated Emissions, FCC Part 15

FCC Radio Test Report. Orpak Systems Ltd.

Transcription:

Nemko Test Report: 109054-1TRFWL Applicant: Autostart Inc. 5764 Rue Paré Mont-Royal, Québec Canada, H4P 2M2 Apparatus: ASRA 2503 FCC ID: EZSNAH2503 In Accordance With: FCC Part 15 Subpart B, 15.107 and 15.109 Unintentional Radiators FCC Part 15 Subpart C, 15.231 Periodic operation in the band 40.66-40.70MHz and above 70 MHz. Authorized By: Date: August 6, 2008 Jason Nixon, Wireless/Telecom Specialist Total Number of Pages: 16 303 River Road, Ottawa, Ontario K1V 1H2 T 1 613 737 9680 F 1 613 737 9691TF 1 800 563 6336 Email Canada@nemko.com Web www.nemko.com

TABLE OF CONTENTS Section 1 : Report Summary...3 Section 2 : Equipment Under Test...4 2.1 Identification of Equipment Under Test (EUT)...4 2.2 Accessories...4 2.3 EUT Description...4 2.4 Technical Specifications of the EUT...4 2.5 EUT Setup diagram...5 2.6 Modifications incorporated in the EUT...5 Section 3 : Test Conditions...6 3.1 Specifications...6 3.2 Deviations From Laboratory Test Procedures...6 3.3 Test Environment...6 3.4 Measurement Uncertainty...6 3.5 Test Equipment...7 Section 4 : Results Summary...8 4.1 FCC Part 15 Subpart B : Test Results...8 4.2 FCC Part 15 Subpart C : Test Results...8 Appendix A : Test Results...9 Clause 15.109(a) Radiated Emissions...9 Appendix B : Test Results...10 Clause 15.209(a) Radiated Emissions within Restricted Bands...10 Clause 15.231(a) Conditions for intentional radiators to comply with periodic operation...12 Clause 15.231(b) Radiated Emissions...13 Clause 15.231(c) 20dB Bandwidth...14 Appendix C : Setup Photographs...15 Appendix D : Block Diagram of Test Setups...16 Page 2 of 16

SECTION 1 : REPORT SUMMARY Section 1 : Report Summary These tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with Part 15, Subpart B and Subpart C. Radiated tests were conducted in accordance with ANSI C63.4-2003. The assessment summary is as follows: Apparatus Assessed: ASRA 2503 Specification: FCC Part 15 Subpart B, 15.107 and 15.109 FCC Part 15 Subpart C, 15.231 Compliance Status: Exclusions: Non-compliances: Report Release History: Test Locations: Complies None None Original Release 303 River Road Ottawa, Ontario K1V 1H2 1500 Peter Robinson Side Road West Carleton, Ontario K0A 1L0 FCC Test Site Reference No.: Tests Performed By: 176392 (3m Semi-Anechoic Chamber), 90845 (OATS) Andrey Adelberg EMC/Wireless Specialist Test Dates: July 2, 2008 to August 1, 2008 Note that the results contained in this report relate only to the items tested and were obtained in the period between the date of initial receipt of samples and the date of issue of the report. This test report has been completed in accordance with the requirements of ISO/IEC 17025. All results contain in this report are within Nemko Canada s ISO/IEC 17025 accreditation. authorizes the applicant to reproduce this report provided it is reproduced in its entirety and for use by the company s employees only. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. Page 3 of 16

SECTION 2 : EQUIPMENT UNDER TEST Section 2 : Equipment Under Test 2.1 Identification of Equipment Under Test (EUT) The following information identifies the EUT under test: Type of Equipment: Keyfob Brand Name: Autostart Model Name or Number: ASRA 2503 Serial Number: None Nemko Sample Number: 1 FCC ID: EZSNAH2503 Date of Receipt: July 2, 2008 2.2 Accessories No accessories were used during this assessment. 2.3 EUT Description The ASRA 2503 is used in the Remote end of a car starter system and operates at 433.92 MHz. (OOK) 2.4 Technical Specifications of the EUT Operating Frequency: Modulation: Occupied Bandwidth: Emission Designator: Antenna Data: Power Supply Requirements: 433.92 MHz ASK 64 khz K1D Integrated 2x CR2025 Battery of 3V Page 4 of 16

SECTION 2 : EQUIPMENT UNDER TEST 2.5 EUT Setup diagram 433.92 MHz 2.6 Modifications incorporated in the EUT There were no modifications performed to the EUT during this assessment. Page 5 of 16

SECTION 3 : TEST CONDITIONS Section 3 : Test Conditions 3.1 Specifications The apparatus was assessed against the following specifications: FCC Part 15 Subpart B, 15.107 and 15.109 Unintentional Radiators FCC Part 15 Subpart C, 15.231 Periodic operation in the band 40.66-40.70 MHz and above 70 MHz. 3.2 Deviations From Laboratory Test Procedures No deviations were made from laboratory test procedures. 3.3 Test Environment All tests were performed under the following environmental conditions: Temperature range : 15 30 o C Humidity range : 20-75 % Pressure range : 86-106 kpa Power supply range : +/- 5% of rated voltages 3.4 Measurement Uncertainty Nemko Canada measurement uncertainty has been calculated using guidance of UKAS LAB 34:2003 and TIA-603-B Nov 7, 2002. All calculations have been performed to provide a confidence level of 95% and can be found in Nemko Canada document MU-003. Page 6 of 16

SECTION 3 : TEST CONDITIONS 3.5 Test Equipment Equipment Manufacturer Model No. Asset/Serial No. Cal. Date Next Cal. Electro-Magnetic Interference Test Chamber TDK SAC-3 FA002047 May 06/08 May 06/09 Bilog Sunol JB3 FA002108 Jan. 21/08 Jan. 21/09 Flush Mount Turntable Sunol FM2022 FA002082 NCR NCR Controller Sunol SC104V FA002060 NCR NCR Mast Sunol TLT2 FA002061 NCR NCR 50 Coax cable HUBER + SUHNER None FA002015 Sept. 19/07 Sept. 19/08 50 Coax cable HUBER + SUHNER None FA002022 July 07/08 July 07/09 Receiver/Spectrum Analyzer Rohde & Schwarz ESU 26 FA002043 Dec. 07/07 Dec. 07/08 Receiver/Spectrum Analyzer Rohde & Schwarz ESU 40 FA002071 Nov. 15/07 Nov. 15/08 1-26.5 GHz Amplifier Hewlett-Packard 8449B FA001761 Sept. 20/07 Sept. 20/08 0.1 1300 MHz Amplifier Hewlett Packard 8447D FA001747 Aug. 10/07 Aug. 10/08 Horn Antenna #1 EMCO 3115 FA000649 Feb 13/08 Feb 13/09 COU Calibrate on Use NCR No Calibration Required Page 7 of 16

SECTION 4 : RESULTS SUMMARY Section 4 : Results Summary This section contains the following: FCC Part 15 Subpart B : Test Results FCC Part 15 Subpart C : Test Results The column headed 'Required' indicates whether the associated clauses were invoked for the apparatus under test. The following abbreviations are used: N Y N/T No : not applicable / not relevant. Yes : Mandatory i.e. the apparatus shall conform to these tests. Not Tested, mandatory but not assessed. (See Report Summary) 4.1 FCC Part 15 Subpart B : Test Results Part 15 Test Description Required Result 15.107(a) Conducted Emissions for Class B N 15.109(a) Radiated Emissions for Class B Y Pass 4.2 FCC Part 15 Subpart C : Test Results Part 15 Test Description Required Result 15.31(e) Variation of Power source N 15.207(a) Powerline Conducted Emissions N 15.209(a) Radiated Emissions within Restricted Bands Y Pass 15.231(a)(1) Manually operated transmitter Y Pass 15.231(a)(2) Automatically activated transmitter N 15.231(a)(3) Periodic transmissions at regular predetermined intervals N 15.231(a)(4) Radiators used in cases of emergency N 15.231(a)(5) Set-up information for security systems N 15.231(b) Radiated Emissions Y Pass 15.231(c) 20dB Bandwidth Y Pass 15.231(d) Devices operating within the frequency band 40.66-40.70 MHz N 15.231(e) Radiated emissions for Periodic radiators N Page 8 of 16

APPENDIX A : TEST RESULTS Specification: FCC Part 15 Subpart B Appendix A : Test Results Clause 15.109(a) Radiated Emissions Except for Class A digital devices, the field strength of radiated emissions from unintentional radiators at a distance of 3 meters shall not exceed the following values: Frequency of Emission Field Strength (MHz) (microvoltsmeter) 30-88 100 88-216 150 216-960 200 Above 960 500 Test Results: Pass Additional Observations: The Spectrum was searched from 30MHz to the 2000 MHz. The EUT was measured on three orthogonal axis with vertical and horizontal receiving antenna. Only worst case was presented. Fresh batteries were used throughout all tests. Measurement equipment setup was 120kHz Quasi-peak detector for measurements below 1GHz and 1MHz RBW/VBW peak detector above 1GHz. All Measurements were performed at 3 meters. No emissions within 20 db below the limit were found Page 9 of 16

APPENDIX B : TEST RESULTS Appendix B : Test Results Clause 15.209(a) Radiated Emissions within Restricted Bands Except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not exceed the field strength levels specified in the following table: Frequency Field Strength Measurement Distance (MHz) (microvoltsmeter) (meters) 0.009-0.490 2400/F (khz) 300 0.490-1.705 24000/F (khz) 30 1.705-30.0 30 30 30-88 100 3 88-216 150 3 216-960 200 3 Above 960 500 3 Test Results: Pass Additional Observations: The Spectrum was searched from 30MHz to the 10 th Harmonic. These results apply to emissions found in the Restricted bands defined in FCC Part 15 Subpart C, 15.205. The EUT was measured on three orthogonal axis with vertical and horizontal receiving antenna. Only worst case was presented. Fresh batteries were used throughout all tests. All measurements were performed using a Peak Detector with 100kHz RBW/VBW below 1GHz and a 1MHz RBW/VBW above 1GHz at a distance of 3 meters. Frequency (MHz) Ant. Polarity RCVD Signal (dbµv/m) Corr. Factor (db) Duty Cycle Corr. 1 1301.76 Horn V 66.466 7.2 23.53 2 3905.28 Horn V 71.479 9.7 23.53 3 4339.2 Horn V 64.840 10.1 23.53 Emission Level (dbµv/m) Limit (dbµv/m) Margin (db) Detector 66.466 74.00 7.534 Peak 42.936 54.00 11.064 Average 71.479 74.00 2.521 Peak 47.949 54.00 6.051 Average 64.84 74.00 9.16 Peak 41.31 54.00 12.69 Average Note 1: Antenna Legend: BC = Biconical, BL = Bilog, LP = Log-Periodic, Horn = Horn, ED = EMCO Dipole Note 2: RCVD Signal includes Correction factor of Antenna factor, cable loss and amplifier gain where applicable. Page 10 of 16

APPENDIX B : TEST RESULTS Duty Cycle within 100ms: Ref 0 dbm Att 30 db RBW 1 MHz VBW 3 MHz SWT 200 ms Delta 2 [T1 ] -0.03 db 110.000000 ms 0-10 1 1 PK * VIEW -20 2 Marker 1 [T1 ] -16.09 dbm 380.317793 as A TRG -30-40 TRG -38.7 dbm -50-60 -70-80 -90-100 Center 433.92 MHz 20 ms/ Packet Transmission: Ref 0 dbm Att 30 db RBW 1 MHz VBW 3 MHz SWT 27 ms Delta 2 [T1 ] 1.73 db 23.296000 ms 0-10 1 PK * 1 VIEW -20 Marker 1 [T1 ] -17.75 dbm 380.317793 as A 2 TRG -30-40 TRG -38.7 dbm -50-60 -70-80 -90-100 Center 433.92 MHz 2.7 ms/ Pulse name: Preamble Start ID and Data CRC Srop Total No of pulses: 3 1 32 8 1 45 On time: 1200µs 130µs 4160µs 1040µs 130µs 6.66ms Duty cycle correction factor calculation: On time 6.66 Duty Cycle = 20log = 20log = 23. 53dB 100ms 100 Page 11 of 16

APPENDIX B : TEST RESULTS Clause 15.231(a) Conditions for intentional radiators to comply with periodic operation The provisions of this section are restricted to periodic operation within the band 40.66-40.70 MHz and above 70 MHz. Except as shown in paragraph (e) of this section, the intentional radiator is restricted to the transmission of a control signal such as those used with alarm systems, door openers, remote switches, etc. Continuous transmissions, voice, video and the radio control of toys are not permitted. Data is permitted to be sent with a control signal. The following conditions shall be met to comply with the provisions for this periodic operation: (1) A manually operated transmitter shall employ a switch that will automatically deactivate the transmitter within not more than 5 seconds of being released. (2) A transmitter activated automatically shall cease transmission within 5 seconds after activation. (3) Periodic transmissions at regular predetermined intervals are not permitted. However, polling or supervision transmissions, including data, to determine system integrity of transmitters used in security or safety applications are allowed if the total duration of transmissions does not exceed more than two seconds per hour for each transmitter. There is no limit on the number of individual transmissions, provided the total transmission time does not exceed two seconds per hour. (4) Intentional radiators, which are employed for radio control purposes during emergencies involving fire, security, and safety of life, when activated to signal an alarm, may operate during the pendency of the alarm condition. (5) Transmission of set-up information for security systems may exceed the transmission duration limits in paragraphs (a)(1) and (a)(2) of this section, provided such transmissions are under the control of a professional installer and do not exceed ten seconds after a manually operated switch is released or a transmitter is activated automatically. Such set-up information may include data. Test Results: Pass (1) Manually operated transmitter, deactivates within 5 seconds after being released: RBW 10 MHz Delta 2 [T1 ] VBW 10 MHz -36.62 db Ref -20 dbm Att 10 db SWT 5 s 30.000000 ms -30-40 -50 1 PK * VIEW -60-70 -80-90 -100-110 1 Marker 1 [T1 ] -29.80 dbm 0.000000 s TRG -51.3 dbm 2 A TRG Center 433.92 MHz 500 ms/ Ref -20 dbm 1-30 -40 Att 10 db RBW 3 MHz VBW 10 MHz SWT 40 ms Delta 2 [T1 ] 0.40 db 24.880000 ms 2 Marker 1 [T1 ] -25.10 dbm -40.000000 µs B -50 1 PK * VIEW -60-70 -80-90 -100-110 TRG -53.8 dbm TRG Center 433.92 MHz 4 ms/ Date: 1.AUG.2008 08:56:28 (2) N/A (3) There are no periodic transmissions at regular predetermined intervals implemented. (4) N/A (5) N/A Page 12 of 16

APPENDIX B : TEST RESULTS Clause 15.231(b) Radiated Emissions In addition to the provisions of 15.205, the field strength of emissions from intentional radiators operated under this section shall not exceed the following: Fundamental Field Strength of Field Strength of Frequency Fundamental Spurious Emissions (MHz) (microvolts/meter) (microvolts/meter) 40.66-40.70 2,250 225 70-130 1,250 125 130-174 1,250 to 3,750 125 to 375 174-260 3,750 375 260-470 3,750 to 12,500 375 to 1,250 Above 470 12,500 1,250 Test Results: Pass Additional Observations: The Spectrum was searched from 30MHz to the 10 th Harmonic. The EUT was measured on three orthogonal axis with vertical and horizontal receiving antenna. Only worst case was presented. Fresh batteries were used throughout all tests. All measurements were performed using a Peak Detector with 100kHz RBW/VBW below 1GHz and a 1MHz RBW/VBW above 1GHz at a distance of 3 meters. Freq. (MHz) Ant. Pol. V/H RCVD Signal (dbµv/m) Corr. Factor (db) Duty Cycle Corr. (db) Peak Level (dbµv/m) Peak Limit (dbµv/m) Margin (db) Average Level (dbµv/m) Average Limit (dbµv/m) Fundamental 433.92 BL V 97.65 20.9 23.53 97.65 100.83 3.18 74.12 80.83 6.71 Harmonics 867.84 BL V 44.844 28.5 23.53 44.844 80.83 35.986 21.314 60.83 39.516 1735.68 Horn V 58.489 8.8 23.53 58.489 80.83 22.341 34.959 60.83 25.871 2169.60 Horn V 56.587 10.9 23.53 56.587 80.83 24.243 33.057 60.83 27.773 2603.52 Horn V 59.795 11.5 23.53 59.795 80.83 21.035 36.265 60.83 24.565 3037.44 Horn V 73.366 12.8 23.53 73.366 80.83 7.464 49.836 60.83 10.994 3471.36 Horn V 73.688 14.3 23.53 73.688 80.83 7.142 50.158 60.83 10.672 Note 1: Antenna Legend: BC = Biconical, BL = Bilog, LP = Log-Periodic, Horn = Horn, ED = EMCO Dipole Note 2: RCVD Signal includes Correction factor of Antenna factor, cable loss and amplifier gain where applicable. Margin (db) Page 13 of 16

APPENDIX B : TEST RESULTS Clause 15.231(c) 20dB Bandwidth The bandwidth of the emission shall be no wider than 0.25% of the center frequency for devices operating above 70 MHz and below 900 MHz. For devices operating above 900 MHz, the emission shall be no wider than 0.5% of the center frequency. Bandwidth is determined at the points 20 db down from the modulated carrier. Test Results: Pass 20dB Bandwidth: Ref 0 dbm Att 30 db * RBW 10 khz VBW 30 khz SWT 5 ms Delta 2 [T1 ] 0.13 db 64.000000000 khz 0-10 D1-11.73 dbm Marker 1 [T1 ] -31.37 dbm 433.950000000 MHz A 1 PK MAXH -20-30 D2-31.73 dbm 1 2-40 -50-60 -70-80 -90-100 Center 433.99 MHz 50 khz/ Span 500 khz Date: 2.JUL.2008 13:21:58 Frequency, MHz 20dB BW, khz Limit, khz Margin, khz 433.92 64 1084.8 1020.8 Page 14 of 16

APPENDIX C : SETUP PHOTOGRAPHS Appendix C : Setup Photographs Spurious Emissions Setup: Page 15 of 16

APPENDIX D : BLOCK DIAGRAM OF TEST SETUPS Appendix D : Block Diagram of Test Setups Radiated Emissions above 30MHz Test Site Radio absorbing material 3 meters Antenna Mast Test Antenna Variable search height (1 to 4 m) EUT Test Antenna 0.8 meters Nonconducting turntable Ground plane To test receiver Page 16 of 16