Ortel (Lucent) Fiber Optic Interface

Similar documents
Ortel (Lucent) Fiber Optic Interface

Ortel (Lucent) Fiber Optic Interface AC

[ tima-datasheet-en v11.1 ]

GPS Dome Installation Manual

GPS6000-PRO. GNSS Time Receiver. User Manual Version 1.1

Cisco Aironet 2.4-GHz/5-GHz 8-dBi Directional Antenna (AIR-ANT2588P3M-N)

Antenna Creation and Installation Instructions

Cisco Aironet Omnidirectional Mast Mount Antenna (AIR-ANT2506)

COAXIAL TRANSMISSION LINE COMMON-MODE CURRENT

Exercise 1-4. The Radar Equation EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION OF FUNDAMENTALS

FiberLink 4040 Series

Broadband Wireless Power Meter User s Manual

External RF Driver. Electrical Driver for AOTF-crystal. Instruction Manual

PM /5.3/5.8GHz Broadband Wireless Power Meter. User s Manual

Multi-Band Wireless Power/ VSWR Meter. PM-6000 User s Manual

Cisco Aironet 13.5-dBi Yagi Mast Mount Antenna (AIR-ANT1949)

5100 Series L-Band Fiber Optic Links

"Smarter Timing Solutions" AFL3430. Antenna Fiber Optic Link. User Manual

LI-1500 Light Sensor Logger

Sarspec, Lda. - Rua Camilo Castelo Branco, 965 PQ Vila Nova de Gaia Phone:

Installation & Service Manual

ST-CCTV-VBAC8 8-Channel Active UTP Video Receiver

ULTRA BROADBAND RF over FIBER Transceiver OZ1606 Series Premium Grade 6 GHz

Antenna Creation and Installation Instructions

Model OB-ITF Infrared Through-Beam Fiber Optic Optical Barrier Operator s Manual. Version

db Systems Model 5100A-HS-ICE DME Antenna

Broadband Step-Up Transformer. User Manual

SatellitePlus Model OLMR. Mini L-Band Receiver. 10-3,600 MHz OPERATING MANUAL

RADIO AND TELEVISION SATELLITE EQUIPMENT

AJKIT-1. Syncbox Anti-jam Upgrade Kit. User Manual Version 1.1

15-GHz & 25-GHz Photodetectors Models 1480-S & 1481-S

PAMS. User s Manual. Portable Attenuation Measurement System. The solution for making easy shielding effectiveness measurements.

Keychain Radio Remote Control System

ST-CCTV-VBAC16 16-Channel Active UTP Video Receiver

SPECIFICATION. Heavy Duty Screw Mount Antenna. Features : Wi-Fi/ISM Bands/ZigBee/WLAN/ Bluetooth. UV and Vandal Resistant ABS Housing

MODEL AT-10 ANALOG TRANSMITTER

HP ProCurve 6.9/7.7dBi Dual Band Directional Antenna (J8999A) Guide

OPERATION AND MAINTENANCE MANUAL TRIAXIAL ACCELEROMETER MODEL PA-23 STOCK NO

Series 48 Water Cooled Laser & UC-2000 Quick Start Guide

SELFSAT-H10D. What is SELFSAT-H10D? Warning!!! Safety Instructions

SPECIFICATION. G21 GSM Hercules Gen.II Penta Band Cellular Antenna

Heritage MedCall. Sentry E-Call Model HM-527 Resident Host Panel

MRS-1000 RADAR SYSTEM USER MANUAL

USER S MANUAL. Rail-mounted temperature transmitter ATL

Technician Licensing Class T9

RF Power Amplifier PA15W Owner s Manual SpinCore Technologies, Inc.

SC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585)

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Multimode Video Fiber Optic Transmission Equipment

M302RM OPERATING MANUAL

Model 1791 VHF Radio User's Manual

F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual

Indoor/Outoor Antenna User s Manual

4 Channel 4~20mA / 0~10VDC Analog DIN Fiber Link System

Optimizing Your Stations Performance

GSM Repeater Systems & Accessories

HydroLynx Systems, Inc.

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

Manual SCA-SS V /02 page 1

Radio Control Installation and Operating Instructions System 4

Cisco Aironet 12 dbi High Gain Omnidirectional Antenna (AIR-ANT24120)

GPS6000-LITE. GPS Time Receiver. User Manual Version 1.1

Instruction Manual. HB Series Mini Level Sensor

BUILD A HIGH PERFORMANCE TWO ELEMENT TRI-BAND CUBICAL QUAD. By Bob Rosier K4OCE INTRODUCTION THEORY AND GENERAL INFORMATION

Agilent 87415A, 87400A Microwave Amplifiers

670K9 SORtrax Level Transmitter

Transmission Line Theory and Advanced Measurements in the Field

WARNING: DO NOT PROCEED WITHOUT READING THIS PAGE.

USER MANUAL MODEL Time Division Multiplexor, RS-232 (CTS TDM-V.24) SALES OFFICE (301) TECHNICAL SUPPORT (301)

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

5.8 GHz Wireless Video/Audio Transmission link XL-5800/H

Type N Coaxial Calibration Kit

SPECIFICATION. G21.W White Hercules Gen II Penta Band Cellular Antenna

Important. Index. Features. Configuration List. CZH-T251 FM Transmitter User Manual

Advanced Test Equipment Rentals ATEC (2832)

USER GUIDE 2.92mm Coaxial Calibration Kit

PPS MFS series - Installation Guide. Power Protector Stabilizer V 3.8 1

RoamAbout Outdoor Antenna Site Preparation Guide

National Radio Astronomy Observatory Socorro, NM EVLA Memorandum 41 Lightning Protection for Fiber Optic Cable. T. Baldwin June 05, 2002

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

DEVAR Inc. 706 Bostwick Ave., Bridgeport CT Tel , Fax

Instruction Manual. Model USB Wattmeter

Model AV-300AHD-MINI

MOXTEK. 50kV 10 Watt MAGNUM X-ray Source. X-ray Sources. Contents

MODEL CM-30. Technical Practice November 2002 Issue 4. Service Observing System 1. GENERAL 2. DESIGN FEATURES CONTENTS: Model CM-30

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

The Standard for over 40 Years

Distance-setting Photoelectric Sensor

Voltage Probe Manual and Data North Star High Voltage, Inc. Rev January 2016

User Guide for the Alpha Loop Sr Antenna

MOBI LE ENHANCER KIT

Advanced Test Equipment Rentals ATEC (2832)

MODERN AM BROADCAST STATIONS AM STEREO CQUAM WITH DDS

Model LS 250 Loop Scanner Operator s Manual. Version

NEW DESIGN***DEM Part Number FRS***NEW DESIGN Low power 144 MHz Transverter for the Flex Radio System SDR-1000 Operating Specifications:

Antenna Installation Guide

User Guide. For. Model Alpha Loop (Sr)

General Product Brochure

PRX4SERL Four Zone Receiver Decoder

RF over Fiber Optic Transceiver OZ816 Series Ultra Broadband 6 GHz

SatellitePlus Model OLMT. Mini L-Band Transmitter. 10-3,600 MHz OPERATING MANUAL

Transcription:

Ortel (Lucent) Fiber Optic Interface 144-701-1 Serial Number January 31, 2013 Part number 098-00120-000 Revision C

ORTEL (LUCENT) FIBER OPTIC INTERFACE 1. GENERAL INFORMATION...1 1.1. SCOPE OF OPTION...1 1.2. PURPOSE OF EQUIPMENT...1 1.2.1. PHYSICAL SPECIFICATION...1 1.2.2. POWER SUPPLY...1 1.2.3. OUTSIDE ENCLOSURE...1 1.2.4. ENVIRONMENTAL SPECIFICATIONS...1 1.2.5. POWER REQUIREMENTS...2 1.2.6. SIGNAL SPECIFICATIONS...2 2 INSTALLATION AND OPERATION...3 2.1. INSTALLATION...3 2.1.1. GENERAL...3 2.1.2. OUTSIDE AND OTHER CHALLENGING LOCATIONS...3 2.1.3. FINISH...3 2.2. OPERATION...3 3. MAINTENANCE AND TROUBLESHOOTING...4 3.1. INTRODUCTION...4 3.2. PREVENTIVE MAINTENANCE...4 3.3. INSPECTION...4 3.4. GENERAL INSTALLATION, TROUBLESHOOTING PROCEDURES.4 4 DRAWINGS...6 4.1. TYPICAL CONNECTIONS...6 5 APPENDIX A...9 5.1. RECOMMENDED FIBER OPTIC CABLE...9 098-00120-000.DOC

1. GENERAL INFORMATION 1.1. SCOPE OF OPTION This manual contains the information necessary to operate and maintain a Symmetricom Model 144-701-1 Fiber Optic Link Option. 1.2. PURPOSE OF EQUIPMENT The Model 144-701-1 Option provides a secure, low loss method of interconnecting a standard Symmetricom antenna and a GPS clock. It can be employed wherever a security boundary must be entered, when protection against lighting strikes is desired, or where the antenna must be located a long distance from the GPS Clock. 1.2.1. PHYSICAL SPECIFICATION Form: Two small enclosures Dimensions (each): 4.28 w x 1.50 h x 2.13 d (10.87 cm w x 3.81 cm h x 5.41 cm d) Weight (each): Approximately 12 ounces (342 g) Fiber Length: 1 to 2000 meters (6560 feet) 1.2.2. POWER SUPPLY Form: Perforated metal enclosure Dimensions: 3.00 w x 4.00 h x 1.125 d (7.64 cm w x 10.16 cm h x 2.86 cm d) Weight: Approximately 1.04 pounds 1.2.3. OUTSIDE ENCLOSURE Form: Dimensions: Weight: Standard: Fiberglass enclosure, hermetically sealed 6.50 w x 8.00 h x 5.38 d (16.51 cm w x 20.32 cm h x 13.67 cm d) Approximately 10 lbs (4.54 kg) NEMA 4X 1.2.4. ENVIRONMENTAL SPECIFICATIONS FIBER OPTIC INTERFACE Operating Temp: Storage Temp: Humidity: Cooling Mode: POWER SUPPLY Operating Temp: Storage Temp: Humidity: Cooling Mode: -40 to +60 C -45 to +65 C 95% relative, non-condensing Convection -25 to +71 C -25 to +85 C 20-90% relative, non-condensing Convection 098-00120-000 1

1.2.5. POWER REQUIREMENTS ANTENNA-CONNECTED LINK Voltage: 5 VDC ± 10% (supplied by external supply) Power: <1 Watt GPS CLOCK-CONNECTED LINK Voltage: 12 VDC (supplied by GPS CLOCK) Power: <1 Watt 1.2.6. SIGNAL SPECIFICATIONS OPTICAL PARAMETERS Type: Optical fiber, 1310 nm wavelength Fiber: Single mode Connector: FC/APC TYPE R RF PARAMETERS Type: Coaxial Impedance: 50 Ω Connector: SMA 098-00120-000 2

2 INSTALLATION AND OPERATION 2.1. INSTALLATION 2.1.1. GENERAL The Symmetricom Model 144-701-1 Fiber Optic Link requires some planning and careful consideration of certain parameters prior to installation. The simplest installation requires installing a suitable length of optical fiber between the GPS Clock site and t he antenna site, mounting the units on a suitable surface, connecting the optical fiber and the coax cables and, in the case of the antenna-connected link, installing the power supply and hooking up its power cables. Be careful to allow enough room for the fibers to make any required bends in a very gentle radius. Typically the bend radius should be greater than ten times the cable outside diameter at least. The optical connectors are FC/APC Type R. Symmetricom may also have supplied cable or cable assemblies as part of the order. Be especially careful when handling the optical fibers to avoid getting dirt or other contaminants in the optical fiber connectors since this will result in poor system performance. 2.1.2. OUTSIDE AND OTHER CHALLENGING LOCATIONS The (144-701-1) Antenna-Connected Fiber Optic Transmitter is housed in an Outside Enclosure that will allow it to be installed in an unprotected location such as a warehouse or bunker. Install the Fiber Optic Enclosure in the most favorable location you can. Consider such factors as service access (especially in inclement weather), power availability, and vandalism. No attempt has been made to make this installable device vandal-proof. The recommended optical fiber and power cable can both be used outdoors in aerial or direct burial applications without any additional protection from the elements. Aerial installations should use a suitable messenger wire to support them. Take wind and ice loading into account when sizing the messenger. Follow the assembly instructions on sheet 2 of 4; print 144-701-1 for proper installation connections. The recommended optical fiber is a tightly coupled product that can be installed with regular wire pulling techniques and can be installed in long vertical runs without problem. It is UL listed and Riser rated so that it does not require a splice box or vault when coming inside a building. Terminate the power, coax, and fiber connectors per standard practice and connect them to the Fiber Optic module inside the box. Tuck all loops neatly inside the box and close it and secure it with the screws provided. Be very careful not to kink either the fibers or the coax cables as you do this. Note that where lightning is a problem, the use of a properly installed coaxial lightning arrester outside of the box may extend the useful life of this product. In an extensive antenna farm the use of lightning dissipative systems may be economically advisable. 2.1.3. FINISH Install the Clock and Antenna according to their manuals. Install the Clock -Connected Fiber Optic Link near the Clock and connect it to the antenna input of the Clock with the provided coax cable. The Clock-Connected Fiber Optic Link is powered by the Clock. 2.2. OPERATION Aside from ensuring that power is applied to the Fiber Optic Link, there are no other operating instructions. However, if the fiber is long you will want to compensate for its length by using the standard cable length compensation function (51) of the GPS Clock. The propagation delay of the fiber is roughly the same as the coax that would normally be installed. The propagation delay of the Fiber Optic modules themselves is 180 ns. Do not forget to add in any coax between the Fiber and the GPS Clock. In addition, remember that the position that the GPS Clock is reporting, is the position of the antenna, not the GPS Clock, since they may be physically quite a distance apart. 098-00120-000 3

3. MAINTENANCE AND TROUBLESHOOTING 3.1. INTRODUCTION Effective maintenance and troubleshooting of this equipment requires a thorough understanding of equipment characteristics, operating procedures, theory of operation, and knowledge of both linear and logic circuit elements. A working knowledge of Fiber Optics theory and connection methods is also required. 3.2. PREVENTIVE MAINTENANCE A systematic preventive maintenance routine can reduce the possibility of a malfunction. This routine should include inspection, qualification, and cleaning of the instrument. 3.3. INSPECTION Exercise care when handling this equipment. It contains sensitive parts that can be damaged by improper handling. Do not touch connector pin surfaces because of the danger of static discharge, also deposits on contact surfaces can cause corrosion, resulting in equipment damage or failure. Inspect the unit for damaged components, loose or frayed connections, and corrosion on metal surfaces. If damage is found, correct it immediately. Be especially careful not to get any foreign material into fiber optic connections as it will degrade or destroy the connection. Keep in mind that the active signal path in the fiber is thinner than a human hair, and so requires only a very tiny speck of whatever to disrupt it. 3.4. GENERAL INSTALLATION, TROUBLESHOOTING PROCEDURES It is recommended that all individual fiber optic components be bench tested before installation to assure trouble free operation. 3.4.1. Configure the GPS receiver with the standard antenna, temporarily placing the antenna with a view of the sky to receive satellites. Verify the GPS receiver s ability to track satellites with appropriate signal levels. Refer to the GPS receiver manual for specified signal level strength. 3.4.2. Configure the GPS receiver with the fiber link making all power and antenna connections on the bench. This may require obtaining a 2-meter test fiber cable. 3.4.3. Verify the receiver s ability to track satellites with appropriate signal levels using the fiber optic link. If the receiver is not tracking satellites adequately check the following connections; Verify the +5V is present at the BNC of the Fiber Optic Transmitter. Check the AC connections to the +5V power supply (red/black wire orientation). If the power supply +5V supply is present, check that there is +5V on the center conductor of the cable end that connects to the antenna. If the voltage levels are correct, check the Receiver's Antenna Status to determine if the connection is "Good" or "OK". If the status is not "Good", inspect the cable ends to verify the fiber optic receiver is disconnected from the cable the GPS is reporting to be open. If shorted, then remove the cable and verify the receiver's status changes to "Open". Replace the cable if the cable is connected, and the receiver status reports "Open". Once the problem has been identified and repaired, reconnect the receiver and check the Antenna Status. Verify correct tracking and signal strengths. 098-00120-000 4

3.4.4. Once the configuration is verified to be tracking satellites with proper signal levels, replace any test components with the final installation components one at a time. If any component is found to degrade the system's performance, repair or replace it. 3.4.5. Once system configuration is verified, proceed with the final installation. If the configuration is not tracking satellites appropriately after verifying antenna status and transmitter output voltage contact Symmetricom for repair or return. Symmetricom offers installation services for this product. 098-00120-000 5

4 DRAWINGS 4.1. TYPICAL CONNECTIONS Typical Antenna Connections for 144-701-1 use and test. 098-00120-000 6

Assy, Fiber Optic Option w/ Enclosure /12V RCVR (4 pages) Page 1 of 4 Page 2 of 4 098-00120-000 7

Page 3 of 4 Page 4 0f 4 098-00120-000 8

5 APPENDIX A 5.1. RECOMMENDED FIBER OPTIC CABLE The fiber optic cable recommended for most indoor/outdoor installations is: Single Mode Fiber, Connector Type FC/APC Type R, 60 db optical return loss. 098-00120-000 9