Development of the 170GHz gyrotron and equatorial launcher for ITER

Similar documents
2. Achievement of reliable long pulse operation of 1 MW 170 GHz gyrotron

CT-7Ra Development of Gyrotron and JT-60U EC Heating System for Fusion Reactor

A High-Power Gyrotron and high-power mm wave technology for Fusion Reactor

Progress of Gyrotron Development for ITER

Development of the long-pulse ECRF system for JT-60SA

The report includes materials of three papers:

Megawatt Power Level 120 GHz Gyrotrons for ITER Start-Up

Operational progress of 170GHz 1MW ECH system in KSTAR

Estimation of the Loss in the ECH Transmission Lines for ITER

Testing of ITER-Class ECH Transmission Line Components at the JAEA Radio-Frequency Test Stand

GA A26150 PROGRESS ON DESIGN AND TESTING OF CORRUGATED WAVEGUIDE COMPONENTS SUITABLE FOR ITER ECH AND CD TRANSMISSION LINES

Recent progress of 170 GHz Gyrotron in KSTAR

Experimental results and Upgrade plan of ECH/CD system in KSTAR

2.2 MW Operation of the European Coaxial-Cavity Pre-Prototype Gyrotron for ITER

GA A25793 CW OPERATION OF CORRUGATED WAVEGUIDE TRANSMISSION LINES FOR ITER ECH AND CD SYSTEM

HIGH-POWER CORRUGATED WAVEGUIDE COMPONENTS FOR mm-wave FUSION HEATING SYSTEMS

Tendencies in the Development of High-Power Gyrotrons

Design study for JT-60SA ECRF system and the latest results of JT-60U ECRF system

GA A26816 DESIGNS OF NEW COMPONENTS FOR ITER ECH&CD TRANSMISSION LINES

Development of a Multi-Purpose, Multi-Frequency Gyrotron for DEMO at KIT

Experimental Results of Series Gyrotrons for the Stellarator W7-X

Development in Russia of Megawatt Power Gyrotrons for Fusion

GA A22776 THE DESIGN AND PERFORMANCE OF WAVEGUIDE TRANSMISSION LINE COMPONENTS FOR PLASMA ELECTRON CYCLOTRON HEATING (ECH) SYSTEMS

INITIAL RESULTS FROM THE MULTI-MEGAWATT 110 GHz ECH SYSTEM FOR THE DIII D TOKAMAK

Study of Elliptical Polarization Requirement of KSTAR 84-GHz ECH System

ECRF Heating on CS Reactors

High Frequency Gyrotrons and Their Applications

THE 110 GHz MICROWAVE HEATING SYSTEM ON THE DIII D TOKAMAK

National Fusion Research Institute a. Princeton Plasma Physics Laboratory

GA A22963 RECENT DEVELOPMENTS ON THE HIGH POWER ECH INSTALLATION AT THE DIII D TOKAMAK

HIGH-POWER CORRUGATED WAVEGUIDE COMPONENTS FOR mm-wave FUSION HEATING SYSTEMS

GA A24691 STATUS OF THE ELECTRON CYCLOTRON HEATING SYSTEM ON DIII D

INFRARED MEASUREMENTS OF THE SYNTHETIC DIAMOND WINDOW OF A 110 GHz HIGH POWER GYROTRON

Development of ITER Equatorial EC Launcher

Summary: Gyrotron Development

INITIAL TESTS AND OPERATION OF A 110 GHz, 1 MW GYROTRON WITH EVACUATED WAVEGUIDE SYSTEM ON THE DIII D TOKAMAK

Development of High Power Gyrotron and Power Modulation Technique using the JT-60U ECRF System )

PERFORMANCE OF THE 110 GHz SYSTEM ON THE DIII D TOKAMAK

MITER BEND MIRROR DESIGN FOR CORRUGATED WAVEGUIDES

US ITER Electron Cyclotron System White Paper

Design and experimental study of a high power 140 GHz, TE22.6 mode gyrotron for EAST

Development Status of KSTAR LHCD System

Heating Issues. G.Granucci on behalf of the project team

PARAMETRIC STUDY OF OHMIC WALL HEATING IN COAXIAL CAVITY

RF Heating and Current Drive in the JT-60U Tokamak

Launcher Study for KSTAR 5 GHz LHCD System*

GA MICROWAVE WINDOW DEVELOPMENT

Recent Development Results in Russia of Megawatt Power Gyrotrons for Plasma Fusion Installations

J.Shafii, J.N. Talmadge, R.J. Vernon, HSX team HSX Plasma Laboratory, University of Wisconsin-Madison T. S. Bigelow, ORNL K.M.

Installation of 84-GHz, 500-kW KSTAR ECH system

1 ITER India, Institute of Plasma Research, 2 Continental Electronics

Gyroklystron Research at CCR

FaDiS, a Fast Switch and Combiner for High-power Millimetre Wave Beams

NEW OPPORTUNITIES IN VACUUM ELECTRONICS USING PHOTONIC BAND GAP STRUCTURES

AN IN-LINE POWER MONITOR FOR HE11 LOW LOSS TRANSMISSION LINES

RECENT UPGRADES AND EXTENSIONS OF THE ASDEX UPGRADE ECRH SYSTEM

PRESENT STATUS OF THE NEW MULTI-FREQUENCY ECRH SYSTEM FOR ASDEX UPGRADE

ECRH on the Levitated Dipole Experiment

Second-Harmonic Fundamental Mode Slotted Peniotron

System Upgrades to the DIII-D Facility

An overview of the ITER electron cyclotron H&CD system

Development of a 20-MeV Dielectric-Loaded Accelerator Test Facility

Towards a 0.24-THz, 1-to-2-MW-class gyrotron for DEMO

Research and Development of 2-frequency (110/138 GHz) FADIS for JT-60SA ECHCD system

Handling Technology of Mega-Watt

FIR Center Report. Gyrotron FU CW VII for 300 MHz and 600 MHz DNP-NMR spectroscopy

Non-inductive Production of Extremely Overdense Spherical Tokamak Plasma by Electron Bernstein Wave Excited via O-X-B Method in LATE

A REGULATED POWER SUPPLY FOR THE FILAMENTS OF A HIGH POWER GYROTRON

DOE/ET PFC/RR-87-10

Study of Ion Cyclotron Emissions due to DD Fusion Product Ions on JT-60U

Development of Collective Thomson Scattering System Using the Gyrotrons of Sub-Tera Hz Region

High Rep-Rate KrF Laser Development and Intense Pulse Interaction Experiments for IFE*

X band Magnetron. Water: Anode cavity Forced-air: Input ceramics and terminals Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

Construction of 0.5-MW prototype PAM for KSTAR LHCD system

S-band Magnetron. Tuner revolutions to cover frequency range 4.75 (note 3) Mounting position (note 4) Any Cooling (note 5) Water

Electromagnetic Field Simulation for ICRF Antenna and Comparison with Experimental Results in LHD

3.10 Lower Hybrid Current Drive (LHCD) System

X-band Magnetron. Cooling (note 5) Water Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

10 MW, 0.14 THz, CW Gyrotron and Optical Transmission System for Millimeter Wave Heating of Plasmas in the Stellarator W7-X

Laser-Produced Sn-plasma for Highvolume Manufacturing EUV Lithography

HIGH POWER INPUT COUPLERS FOR THE STF BASELINE CAVITY SYSTEM AT KEK

PRACTICAL EXPERIENCES WITH THE 6 GYROTRON SYSTEM ON THE DIII D TOKAMAK

Max-Planck-Institut für Plasmaphysik

Active Control for Stabilization of Neoclassical Tearing Modes

P. Koert, P. MacGibbon, R. Vieira, D. Terry, R.Leccacorvi, J. Doody, W. Beck. October 2008

THE MEASURED PERFORMANCE OF A 170 GHz REMOTE STEERING LAUNCHER

Design, Development and Testing of RF Window for C band 250 kw CW Power Klystron

ICRF Physics in KSTAR Steady State

RF and Microwave Power Standards: Extending beyond 110 GHz

First Results From the Alcator C-Mod Lower Hybrid Experiment.

H. Y. Lee, J. W. Lee, J. G. Jo, J. Y. Park, S. C. Kim, J. I. Wang, J. Y. Jang, S. H. Kim, Y. S. Na, Y. S. Hwang

Design and Construction of 2.45 GHz Microwave Plasma Source at Atmospheric Pressure

Couplers for Project X. S. Kazakov, T. Khabiboulline

GA A25836 PRE-IONIZATION EXPERIMENTS IN THE DIII-D TOKAMAK USING X-MODE SECOND HARMONIC ELECTRON CYCLOTRON HEATING

Study of Plasma Equilibrium during the AC Current Reversal Phase on the STOR-M Tokamak

Neoclassical Tearing Mode Control with ECCD and Magnetic Island Evolution in JT-60U

The 140-GHz 1-MW CW Gyrotron for the Stellarator W7-X

Experimental Plan for Testing the UNM Metamaterial Slow Wave Structure for High Power Microwave Generation

A Modular Commercial Tokamak Reactor with Day Long Pulses

RF STATUS OF SUPERCONDUCTING MODULE DEVELOPMENT SUITABLE FOR CW OPERATION: ELBE CRYOSTATS

Transcription:

Development of the 17GHz gyrotron and equatorial launcher for ITER K.Sakamoto, A. Kasugai, K. Takahashi, R. Minami a), T. Kariya b), Y. Mitsunaka b), N.Kobayashi Plasma Heating Laboratory, Japan Atomic Energy Agency (JAEA), 81-1Mukoyama, Naka-shi, Ibaraki, Japan 311-193 Abstract. Recent progresses on the development of 17GHz gyrotron and an equatorial launcher are described. On the development of 17 GHz gyrotron, significant progress has been obtained. Up to now, stable 1 hour oscillation was demonstrated at the output power of.6 MW, which exceeds a discharge time of steady state experiment of ITER (3 s). By optimizing the oscillation condition during the shot, the output power was enhanced up to.82 MW. The efficiency was 56 % with the depressed collector operation, and no trouble was found for 1min. The measured stray radiation in the gyrotron is 2 %, and the coupling efficiency with the corrugated waveguide is 96 %. In the design of the equatorial launcher, quasi-optical RF beam line was introduced. Consequently, the heat load on the movable mirrors due to the Ohmic loss of RF power was significantly reduced. These results give a clear prospect for an accomplishment of ITER ECH/ECCH system. Email of K.Sakamoto: sakamoto.keishi@jaea.go.jp 1. Introduction In ITER, the electron cyclotron heating and current drive system (ECH/ECCD) of 2 MW is planed [1]. As a power source of ECH/ECCD system, the developments of 1 MW/17 GHz gyrotron are underway at Russia [2], EU [3] and Japan. In JAEA (Japan Atomic Energy Agency), key technologies such as a demonstration of a depressed collector [4], demonstration of 17 GHz/1 MW oscillation at CW-relevant mode TE 31,8 [5], a success of the application of a synthetic diamond window [6-8], were carried out in ITER EDA (Engineering Design Activities). After ITER EDA, the pulse extension experiment has been continued, and.5 MW, 1 s was obtained in 23 [9]. An improvement of built-in mode converter has been tried to reduce the stray radiation in the gyrotron in 24. For CW operation, the cooling capability of the gyrotron test stand was enhanced in 25. The electron beam current decreased during a shot due to the cathode cooling, a pre-program control of the heater power of the magnetron injection gun (MIG) was introduced (heater boost). These improvements enabled stable long pulse operations, 1 s at.2 MW and 5 s at.3 MW [1]. In parallel, the oscillation experiment of a higher order volume mode, TE 31,12, at 17 GHz was carried out to study the feasibility of power enhancement. The cavity is cylindrical one, which gives an option of high order oscillation mode for long pulse higher power generation [11]. In this paper, the recent significant progress on the 17 GHz gyrotron for ITER and the updated design work of equatorial launcher are reported. In section 2, results of CW high efficiency 17GHz gyrotron development is described. In section 3, a design work for equatorial launcher is reported. Conclusion is given in section 4. 1

FIG. 1. (a) Picture of 17GHz gyrotron (b) and the inner configuration. 2. 17GHz Long Pulse Gyrotron 2.1. Configuration of 17GHz Gyrotron and Experimental Set-up A picture of the 17 GHz gyrotron is shown in Fig.1(a), and the inner configuration is shown in Fig.1(b). The MIG is a triode. The oscillation mode is TE 31,8 at 17 GHz. The Q-factor of the cavity is 153. The oscillation power is converted to the Gaussian beam by a built-in launcher and transported to the diamond window using four mirrors. An inner surface of the launcher is optimized to minimize a diffraction loss [13,14]. Fig.2 shows a radiation field distribution to the cylindrical surface at 6mm radius around the launcher. A rectangle in the figure denotes the area of the first mirror. A 99.5 % of the radiated power enters the first mirror. A stray radiation is extracted from a sub-window and from a ceramic insulator made of silicon nitride (SiN) between a body and a collector sections for the depressed collector operation. A 97.7 % of oscillation power is outputted from the diamond window. The collector is grounded. A positive voltage is applied to the body section for the depressed collector operation. In a long pulse operation, generally, some parameters change during the shot. For example, beam current decrease, oscillation frequency decrease due to the thermal expansion of the cavity, pitch factor of the rotational electron beam decrease. The time scale of these change are ~1min.,.5sec, a few second, respectively. To compensate these change, heater power, magnetic field at the cavity (cavity field), anode voltage of the MIG are controlled during the oscillation. The output power couples with evacuated corrugated waveguide via two mirrors in matching optics unit (MOU). In the MOU, two-phase correlation mirrors are installed to couple with a HE 11 mode at the input of the corrugated waveguide. The inner diameter of the waveguide is 63.5 mm, which will be adopted in ITER. In Fig.3, the photo of the transmission line is shown. The transmission line is composed of 7 m-waveguide, two-miter bends, a pre-dummy load and a 1 MW CW load. The transmission line was evacuated to suppress a breakdown. 2

3 1st mirror db Z (mm) 15 36 φ (degree) -3 FIG. 2. A radiation field distribution to the cylindrical surface at 6 mm radius around the launcher. Rectangle denotes the area of first mirror. Pre-load Directional Coupler From Gyrotron Dummy load 63.5mm evacuated W/G (ITER size) FIG. 3. Transmission line that connect the gyrotron and the dummy load. The transmission line composed of two miter bends, evacuated corrugated waveguide, pre-load and dummy load for 1 MW CW operation. Total length is ~7 m. The waveguide comes out from the X-ray shield room inside which the gyrotron is installed. The power is measured calorimetrically from the temperature increase of cooling water of the dummy load and pre-load. 3

2.2. Short Pulse Experiment Prior to the long pulse experiment, the gyrotron characteristics are studied at short pulse. The beam current dependence of output power and efficiency without the depressed collector is shown in Fig.4. The output power was measured by a dummy load made of silicon carbide, which was directly connected to the output window. The pulse duration was <1 ms, and the beam voltage was 72 kv. 1.4 1.2 7 6 Power (MW) 1.8.6.4.2 5 4 3 2 1 Efficiency (%) w/o depressed collector 1 2 3 4 5 6 7 Beam Current (A) FIG. 4. Beam current dependence of output power and efficiency without depressed collector. Beam voltage is 72 kv, and pulse duration is 1 ms. Frequency is 17 GHz. The detected frequency was 17 GHz. The oscillation power increase with the beam current and the output power exceeds 1 MW at the beam current I c of ~49 A. In next, the depressed collector voltage was applied at the beam current I c ~49.5 A. Pulse duration was 26 ms. At the depressed collector voltage V D =27 kv, overall efficiency reached at 51 % with the output power of ~1.12 MW. 2.3. Long Pulse Experiment After the short pulse operation, the MOU was connected to the gyrotron as shown in 2.1. A pulse extension was carried out at the beam voltage of 72 kv, I c ~3 A, B t =6.67 T. Fig.5 shows time traces of the depressed collector voltage, anode voltage, I C, RF signal measured by a directional coupler, photo signal measured by a photo-multiplier from the viewing port of the gyrotron, a current of an 8 litter ion pump at the pulse duration of 36 s. The output power at the gyrotron window is ~.6 MW. The voltage of the main power supply was 44 kv. The overall efficiency with the depressed collector was 46 %. The RF power is identified from the temperature increases of the cooling water. All signals were stable. The vacuum pressure decreased after 4 min. The pulse duration is longer than that of the steady state experiment of ITER (3 s). Fig.6 shows a conditioning process for pulse extension up to 1 s. Within 1 days, the pulse was extended from.8 s to 1 s at.6 MW output. 4

12 Anode Volt.(2kV/div) Cathode Volt.(2kV/div) Beam Current (1A/div) Light from Gyrotron (a.u.) Vacuum Pressure (1x1-8 torr/div) RF Power (.6MW) 36s FIG. 5. Typical signals at long pulse operation of the gyrotron. Pulse Duration (s) 1 8 6 4 2 Power ~.6MW (17GHz) 1s 18s.8s 3s 2s 38s 3s 6s 1s 1 2 3 4 5 6 7 8 9 Working Day for Pulse Extension FIG. 6. Progress of pulse extension at initial phase of conditioning. Fig.7 shows the RF power balance in case the transmitted power of.6 MW. In the MOU, the measured power dissipation is 25 kw, and loss in the transmission line estimated from the waveguide temperature increase is ~5 kw. 6kW 4-Direction Adjustable Phase Correction Mirrors Calorimetric Load 31.75mm Corrugated W/G Loss in Waveguide: ~5kW 63.5mm Corrugated W/G (evacuated) 4m 2m Water Cooled Stray RF Absorber at dummy load (95%) Loss in MOU 25kW (4%) 1m Positioning Micrometers MOU 63kW Gyrotron Adjustable Focusing Mirror RF Power 12.4kW 13kW (2%) Support Stand Movable Mirror Ceramic for Calorimetric Measurement Ceramic FIG. 7. Power balance of gyrotron and transmission line. This indicates that the transmission efficiency to the dummy load via MOU, two miter bends and 7 m waveguides is 95 %, which gives a prospect for ITER transmission system. The stray radiation power coming out of the sub-window and the SiN cylinder is 12.4 kw (2 %). 5

2.4. Efficiency Enhancement In the long pulse operation, the operation parameters are usually fixed. However, in CW operation, the operation parameters can be optimized during the oscillation in a finite time scale. In particular, in case of triode type MIG, there is an advantage that the pitch factor of the electron beam is controlled easily. With a combination of the cavity field control, the effective efficiency optimization is expected. Procedure to access the optimum parameter is as follows. The target mode is excited at proper parameters at first. This parameters need not to be an optimum. Next, the pitch factor and the cavity field are justified toward the optimum parameters during the shot keeping the target mode oscillation. With this active control method, the output power was significantly enhanced from.6 MW to.82 MW. The pulse duration was 1 min. The beam current and voltage were the same with those of 1hr operation shown in section 2.3. Consequently, the overall efficiency increased up to 56 %, which exceeds well the expected efficiency for ITER, 5 %. It should be noted that the efficiency is higher than that obtained in the short pulse operation as shown in Fig.4. One reason is the conditioning effect of the MIG. After the long pulse experiment, the efficiency has a tendency to increases compared with the initial stage. Another important reason is the optimization of the parameters is much easier that the short pulse operation in which a sensitive control of voltage start-up scenario is required to excite a desired high order mode. This method presents a possibility to avoid the mode competition problem and to realize a high efficiency oscillation at further higher mode. 3. Equatorial Launcher In Fig.8, the reference design of the equatorial launcher is shown. The primary boundary of a transmission line is a tritium shield diamond window. The injection angles of three RF beam lines are controlled independently by three movable mirrors. The RF power is injected obliquely into the plasma for current drive. Onto the movable mirror, RF power is fed from 8 waveguides. A reference design is to transmit the RF power to the movable mirror using the waveguide array. One problem is that the peak heat load due to the RF loss on the movable mirror is relatively high ~3.2 MW/m 2. To reduce the heat load, quasi-optical transmission is proposed in the launcher. It is found the power density can be significantly reduced to less than 1. MW/m 2 by expanding the radius of each beam by adopting a quasi-optical transmission. In Fig.9 (a), the cross sectional view of the launcher (plane) is shown. The bundle of the waveguides was replaced to the empty space and the fixed mirror. The RF beams are radiated from the truncated corrugated waveguides toward the fixed mirror. Figs.9 (b) and (c) are the power distribution on the movable mirrors for waveguide transmission and quasi-optical one, respectively. These show the heat deposition to the movable mirror was averaged in the quasi-optical method and contributes to the reduction of the heat load. A simulation indicates the neutron flux at the window section is well below the critical value for the quasi-optical configuration. As for the R&D s of launcher components, neutron irradiation tests have been carried out for key components of a movable mirror, and reveal the applicability to ITER neutron environment [15]. And, the mock-ups of movable mirror, the tritium shield window, mirror supports and a controlling system of the movable mirror have been fabricated and tested. It was shown that these components would be feasible for the launcher. 6

IT/2-4Rc 4 3 2 1 Z(m) -1-2 -3-4 -5 4 5 6 7 8 R(m) FIG. 8. Conceptual view of equatorial launcher and RF beams in the ITER plasma. Fixed mirror ~1m Front shield Corrugated waveguides ~1m RF beam Movable mirror Neutron shield Tritium shielding window (a) (b) (c) FIG. 9. (a) plane view of the equatorial launcher. The RF beams are radiated from the truncated corrugated waveguides and the flat RF distribution are formed on the mirrors. (b) The RF power distribution on the movable mirror for the waveguide transmission. (c) The RF power distribution for quasi-optical transmission. 7

4. Conclusion The recent progress of 17 GHz gyrotron development in JAEA was described. The stable 1 hour oscillation was demonstrated at output power of.6mw with the overall efficiency of 46 %. These are significantly enhanced by the parameter optimization during the shot up to.82 MW and the efficiency of 56 % with the depressed collector. In the design work of equatorial launcher, the quasi-optical RF beam transmission was proposed, which significantly reduce the heat load due to the Ohmic loss on the mirrors in the launcher. These results give a clear prospect for accomplishment of ITER ECH/ECCD system. Acknowledgments We would like to thank to Dr.H.Takatsu, Dr.R.Yoshino and Dr.T.Tsunematsu for their encouragement. a) Present address: Plasma research center, Tsukuba university, Tennohdai, Tsukuba, Ibaraki, 35-8577 Japan. b) Toshiba Electron tubes & devices co.,ltd, Ohtawara-shi, Tochigi, 324-855 Japan. References [1] Technical Basis for the ITER Final Design Report (FDR), 21. [2] Litvak, A.G., et al., in Proc. IAEA Fusion Energy Conference 24, FT/1-1Ra (24). [3] Piosczk,B., Dammertz,G., Dumbrajs,O., et al., J. of Physics:CS 25 (25) 24. [4] Sakamoto,K.,, Tsuneoka,M., Phys.Rev.Lett., 73, (1994) 3532. [5] Sakamoto,K., Kasugai,A., J.Phys.Soc.Jpn., 65, (1996) 1888. [6] Braz,O., Kasugai,A., Sakamoto,K., et al., Int.J.Infrared and millimeter Waves, 18, (1997) 1495. [7] Kasugai,A., Sakamoto,K., et al., Rev. Sci. Instrum, 69, (1998) 216. [8] Sakamoto, K., Kasugai,A., et al., Rev. Sci. Instrum., 7, (1999) 28. [9] Sakamoto,K., Kasugai,A., et al., Nucl. Fusion, 43 (23) 729. [1] Kasugai,A., Minami, R.,et al., to be published in Fusion Eng. Des.(26). [11] Sakamoto,K., Kasugai,A., et al., J. of Physcs: CS 25 (25) 8. [12] Sakamoto, K., Takahashi,K., Kasugai,A., et al., Fusion Engineering and Design, 81 (26) 1263. [13] Neilson,J., IEEE Trans. Plasma Science, vol.34 (26). [14] Minami,R., Kasugai,A., et al., J.Infrared and mm waves, 27, no.1 (26) 14. [15] Takahashi,K., Kobayashi,N., et al., J. of Physcs: CS 25 (25) 75. 8