TV filters. Operating Power TYPES

Similar documents
TV combiners. Combiners with mask filters for digital operation TYPE DESCRIPTION

RF Systems. Filters Combiners Components. Engineering Excellence since 1942

Input Return Loss, db > 26 Narrowband to Narrowband Isolation, db > 30

TV combiners. Combiners with mask filters for digital operation TYPE DESCRIPTION

BCA. Combiners and Filters for FM Broadcast and TV Systems

Band-Tunable TV Mask Filters and FM combiners Presented by: Dan Fallon Sr. RF Engineer

Four channel UHF Adjacent Channel Constant Impedance Combiner/Mask Filter System Installed at 10,200ft AMSL

BCA. Combiners and Filters for FM Broadcast and TV Systems ABRIDGEMENT

ERI FM Band Pass Filters

Air & liquid scalable and flexible power ampilfier solutions up to 50 kw of VHF/UHF power

780-8 Series Constant Impedance FM Combiners

Circulator Construction

MD / KD Series. UHF Solid State Analog or Dual Cast TV Transmitters / Amplifiers

Transmitter Tetrode TH 347

AOM Driver A35-Series

Transmitter Tetrode RS 1034

Product Catalog Spring 2017 AmericanAmpTech.com

Maxiva UAXT Ultra-Compact/ VAXT Ultra-Compact Low Power UHF/VHF Transmitter / Transposer / Gap Filler

TECHNICAL INFORMATION

HLV Instruction & Operations Manual


First DTV Antenna on the Hancock Building Chicago, USA

8792 Power Tube. Linear Beam Power Amplifier Tube

SC5407A/SC5408A 100 khz to 6 GHz RF Upconverter. Datasheet. Rev SignalCore, Inc.

Combined Band MHz. Fig. 1 Typical Diplexer Filter Combiner Fig. 2 Typical Diplexer Combiner

DL Series UHF Top Mount Slot Antennas

Air Band Multicoupling Products MHz MHz

HIGH POWER LIQUID COOLED SOLID STATE UHF TV TRANSMITTER

FM Broa dcast C atalo


Continental's 816R -5B, 35 kw Single Tube Broadcast Transmitter. Includes the 802A solid -state exciter

SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter. Datasheet SignalCore, Inc.

Block Upconverters for Integration in High Power Amplifiers

CIRCULATOR APPLICATION NOTE ANV001.

Transmit Combiners. To view the catalog online or download, go to Aurora Rd. Solon, OH Phone

Antenna Technology Bootcamp. NTA Show 2017 Denver, CO

Moveable Probe Thick Silver Plated

1208 P10-VHF-H-20. Frequency Range: MHz. Efficiency: 10% Temperature Range: 0 to 70 C Max VSWR: 5:1. Class: Supply Voltage: 28.

Ku-Band. Reliable Designed and built to survive in extremely adverse environmental conditions. Operates in ambient temperatures up to 60 C.

AOM Driver 3307 Series

TELEVISION TRANSMITTERS

SC5306B 1 MHz to 3.9 GHz RF Downconverter Core Module. Datasheet SignalCore, Inc.

KU- BAND TEMPERATURE COMPENSATED HIGH POWER MULTIPLEXERS S. Lundquist, M. Yu, D. Smith, W. Fitzpatrick COM DEV, Cambridge, CANADA


AOM Driver 2910 Series

Screening Attenuation When enough is enough

Products. Dielectric Resonators. Description: Specifications: Attenuation:

Register your product and get support at. SDV7220/12. User manual

Frequency Range: MHz. Efficiency: 10% Temperature Range: 0 to 60 C Max VSWR: 5:1. Class: Supply Voltage: 28.0V

SUBNANOSECOND PULSE GENERATOR PPG-2/1000 USER MANUAL

Manufacturers of RF and Microwave Components and Assemblies Specialist in RF Filters, Power amplifiers and RF Switches

TETRA Tx Test Solution

Maxiva TM VAX Compact

Series CCR-33K/CR-33K Miniature DC 33.5 GHz Failsafe SPDT Coaxial Switch

Measurement and Analysis for Switchmode Power Design

Series CCS-47/CS-47 High Power DC 12 GHz Failsafe TRANSFER Coaxial Switch

Cavity Filters. Waveguide Filters

HLV-350. Instruction & Operations Manual


DATASHEET. X-band Transmitter

Broadcast Solutions. DVB-T/T2, DAB/DMB, ISDB-T/T B, ATSC & Analog TV

9007 Power Tube. VHF Linear Power Amplifier Tube 33 Kilowatt Peak Sync Output Thru VHF-TV Band

Technician License. Course

Technician License Course Chapter 4. Lesson Plan Module 9 Antenna Fundamentals, Feed Lines & SWR

HLV Instruction & Operations Manual. Content

ytivac Cavity Filters

The Micromega MyAMP. A serious design challenge

Datasheet SHF 100 BPP

Model Directional RF Wattmeter

SPINNER RADAR & SATELLITE

Electrical Design of Narrow Band Filters. Giuseppe Macchiarella Polytechnic of Milan, Italy Electronic and Information Department

Series CCR-33K/CR-33 K Miniature DC 33.5 GHz Failsafe SPDT Coaxial Switch

Series CCR-33S/CR-33S Miniature DC 18 GHz/DC-22 GHz Failsafe SPDT Coaxial Switch

Series CCS-47/CS-47 High Power DC 12 GHz Latching TRANSFER Coaxial Switch

ELECTRO TECHNIK. Phone: ELECTRO TECHNIK

Register your product and get support at SDV6123/10. EN User manual

Series CCP-47N Low PIM DC 3 GHz Latching TRANSFER Coaxial Switch


AS-1250FE Datasheet Dynamic Signal Acquisition Front-End for Rotating Machinery Monitoring and Analysis

Series CCS-37S/CS-37S Miniature DC 18 GHz Failsafe TRANSFER Coaxial Switch

MT3200A TRAVELING WAVE TUBE MEDIUM POWER AMPLIFIER

120W UHF Transmitter/Repeater

Series CCP-32N Low PIM DC 3 GHz Latching SPDT Coaxial Switch

Register your product and get support at SDV6224/12. EN User manual

Waveguides. Metal Waveguides. Dielectric Waveguides

Transmitter Tetrode. Approx. weight 1,1 kg Packing dimensions: approx. 310 mm 310 mm 320 mm. Siemens Aktiengesellschaft 375

Series CCS-19 Multi-Throw DC-2 GHz Latching Coaxial Switch

Series CCS-37S/CS-37S Miniature DC 18 GHz Latching TRANSFER Coaxial Switch

SHF Communication Technologies AG

CORRY MICRONICS, INC. 761 COMMONWEALTH DRIVE SUITE 201 WARRENDALE, PA P F

SHF Communication Technologies AG. Wilhelm-von-Siemens-Str. 23D Berlin Germany. Phone Fax

Part Numbering System

UHF Band IV-V TV Antennas I230E Series -4 dipoles Panels-

5000 Series Receiver Systems

TRANSMITTER COMBINERS

Understanding and Optimizing Electromagnetic Compatibility in Switchmode Power Supplies

FEATURES: Reduced Depth. Output RF Power Hold. Easily Accessible Diagnostic Port. Programmable Alarms. Event And Maintenance Logs. Ethernet Interface


CHAPTER - 6 PIN DIODE CONTROL CIRCUITS FOR WIRELESS COMMUNICATIONS SYSTEMS

Performance and Design without compromise

Transcription:

TV filters TYPES BF4-3C500 BF4-4C500 BF4-4C100D-N BF4-6C500 BF4-6C100D-N BF4-3C1K0 BF4-4C1K0 BF4-4C250D-N BF4-6C1K0 BF4-6C250D-N BF4-4C1K7 BF4-4C2K1-HS BF4-4C3K5 BF4-4C4K0-HS BF4-4C13K-LC BF4-4C7K0 BF4-4C9K0-HS BF4-4C20K-LC BF4-6C130D-N BF4-7C130D-C BF4-6C250D-N BF4-7C250D-C BF4-6C550D-N BF4-6C700D-N-HS BF4-6C550D-C BF4-6C700D-C-HS BF4-8C500D-C BF4-8C600D-C-HS BF4-6C1K1D-N BF4-6C1K5D-N-HS BF4-6C1K1D-C BF4-6C1K5D-C-HS BF4-8C1K0D-C BF4-8C1K3D-C-HS BF4-6C2K5D-N BF4-6C7K5D-N-LC BF4-6C2K5D-C Band-pass filters are used to attenuate frequencies outside a narrow pass-band. They are commonly used as components in the design of combiners, for the attenuation of noisy side bands, to achieve additional decoupling between transmitters installed in close proximity in the same antenna system, and to combine digital channels with existing analogue channels. The band-pass filters are factory tuned to the desired operating channels. All filters are retunable on whole frequency bands III (VHF) and bands IV and V (UHF). Band-pass filters consist of 3, 4, 6, 7 or 8 magnetic coupled coaxial resonators with adjustable coupling. One end of the resonator is open-circuited and the other short-circuited and tuning is accomplished by rotating the circular central conductor at the lower end of each resonator. The coaxial input and output lines are coupled to the first and last resonator by magnetic coupling loops. ELTI critical mask filters for digital operation are 6, 7 and 8 cavity filters with elliptical response to satisfy critical mask requirements or adjacent channel configuration for DVB, ISDB-T and ATSC standards. Critical mask filter with 6 cavities are generally used with ELTI transmitters only. Main advantages of these filters are: foreshorten folded combline design, iris couplings with fine bandwidth regulation, retunable on whole frequency bands III, IV and V. Filters are part of ELTI complete solutions: transmitter TERX, as output filter available on request, regenerative repeater ARX, as output filter available on request, combiners for adjacent channel configuration and/or non-critical & critical mask requirements. Operating Power The maximum operating power of a filter is limited by heating and peak voltage. Heating is caused by high currents on resonators and are the main cause of dissipation due to Joule effect. Other secondary causes are the dissipations in the remaining circuit elements and in the dielectrics. To reduce losses, particularly at high frequencies, the conducting surfaces need to be excellent conductors. An accurate analysis of dissipations conducted using electromagnetic simulations makes it possible to optimize the construction for minimal loss. The peak voltage represents the absolute power limit of a filter. The possibility of a breakdown occurring is related to the dielectric rigidity and the various ambient conditions (temperature, humidity and pressure). An accurate analysis of the breakdown limits requires specific electromagnetic and circuit simulations. All ELTI filters are designed for a voltage safety factor of at least 2 at the maximum rated power.

In specifications are stated power in rms (digital mode) and p.s. (analogue mode) for 8 MHz channel (UHF) and 7 MHz (VHF). Filters for digital operation can be used for analogue or dual cast mode. Use multiplier 1,5 of rms power to calculate peak sync power. For digital 7 MHz channel use multiplier 0,9 and for 6 MHz channel multiplier 0,75. Operating temperature All ELTI filters are designed to operate in severe environmental conditions such as -5 to +55 C, as expected inside a typical transmitter operating in a standard environment (EN 300 190, Class 3.1). In these conditions, the maximum temperature raise is specified for each filter (typically < 40 C). For safety reasons, and for optimum performances and filter s lasting, the maximum filter s body temperature should never exceed 70 C, and the recommended operating temperature limit is 60 C. The operation at the maximum rated power generally requires some cooling: conventional cooling, conventional cooling with heat sinks added on the top of the filter, UHF high power filters can be optionally equipped with a state-of-the art water cooling circuit, to be inserted in liquid cooled transmitters. Type of cooling is given in specifications. Extremely low temperatures (< -15 C) should be avoided, as they could deteriorate the filters due to excessive thermal shocks, primarily during the transient warm-up. Passive Intermodulation All of the passive components involved with digital signals must possess a very high degree of linearity, to prevent Passive Inter Modulation (PIM). All ELTI passive components are designed and fully meet the typical PIM < -153 dbc requirement. Electrostatic Protection All ELTI filters have an adequate electrostatic protection on input / output connectors, i.e. the inner terminals are electrically connected to ground (DC short circuit), with a current capacity always much higher than the one of the connector itself. TYPES BF4-6C7K5D-C-LC BF4-8C2K5D-C BF4-8C7K5D-C-LC BF4-6C5K0D-N BF4-6C12K5D-N-LC BF4-6C5K0D-C BF4-6C12K5D-C-LC BF4-8C4K5D-C BF4-8C11KD-C-LC BF3-6C125D-N BF3-6C900D-N BF3-6C1K8D-N BF3-6C6K0D-N-LC BF3-8C1K5D-C BF3-8C5K5D-C-LC BF3-6C4K0D-N BF3-6C10KD-N-LC BF3-8C3K5D-C BF3-8C9K0D-C-LC BF3-6C8K0D-N BF3-6C20KD-N-LC BF3-8C7K0D-C BF3-8C17KD-C-LC TYPE DESCRIPTION ANALOGUE: BFx-yCppp-M-(zz) DIGITAL: BFx-yCpppD-M-(zz) BF - band pass filter x - frequency range 3 - VHF band III (174-230 MHz) 4 - UHF band IV/V (470-862 MHz) yc - number of cavities 3C - 3 cavity filter 4C - 4 cavity filter 6C - 6 cavity filter 7C - 7 cavity filter 8C - 8 cavity filter ppp - input power peak sync pppd - input power rms 100 - up to 100 W 1K0 - up to 1 kw 10K - up to 10 kw M - mask (for digital mode) N - non-critical mask C - critical mask zz - cooling without - conventional HS - heat sink added LC - liquid cooled

Specifications UHF non-critical & critical mask filters up to 250 W rms BF4-6C130D-N BF4-7C130D-C BF4-6C250D-N BF4-7C250D-C Mask DVB non- critical mask critical mask non- critical mask critical mask Mask ISDB-T non- critical mask critical mask non- critical mask critical mask Number of cavities (elliptical response) 6 7 6 7 conventional cooling 130 W rms 130 W rms 250 W rms 250 W rms Return loss (db) > 24 > 22 > 24 > 22 f0 ± 4,2 MHz > 5 > 15 > 5 > 15 f0 ± 6 MHz > 16 > 26 > 16 > 26 f0 ± 12 MHz > 41 > 51 > 41 > 51 Center frequency (f0) < 1,00 < 1,40 < 0,75 < 1,00 f0 ± 3,805 MHz) < 2,70 < 4,80 < 2,00 < 3,60 Harmonic attenuation (db) up to 1,8 / 1,4 GHz > 50 up to 1,8 GHz > 50 up to 1,8 GHz > 50 up to 1,4 GHz > 50 up to 1,4 GHz up to 3 GHz (with low-pass filter) > 50 > 50 > 50 > 50 Group delay variation (ns) < 200 ns < 320 ns < 200 ns < 350 ns Temperature stability (khz/k)* < 2 Input and output connectors N female (default) DIN 7/16 female DIN 7/16 female (default) N female Weight (kg) 2,5 2,9 3,5 4,1 Dimensions (mm) 324 x 42 x 172 386 x 42 x 172 420 x 53 x 185 482 x 53 x 185 conventional BF4-7C230D-C BF4-6C130D-N BF4-7C130D-C BF4-6C250D-N

Specifications UHF non-critical & critical mask filters up to 700 W rms BF4-6C550D-N BF4-6C700D-N-HS BF4-6C550D-C BF4-6C700D-C-HS BF4-8C500D-C BF4-8C600D-C-HS Mask DVB non-critical mask critical mask critical mask Mask ISDB-T non-critical mask critical mask critical mask Number of cavities (elliptical response) 6 8 conventional cooling 550 W rms 500 W rms heat sink 700 W rms 600 W rms Return loss (db) > 26 > 21 > 26 f0 ± 4,2 MHz > 5 > 12 > 15 f0 ± 6 MHz > 16 > 24 > 26 f0 ± 12 MHz > 41 > 34 > 51 Center frequency (f0) < 0,46 < 0,54 < 0,71 f0 ± 3,805 MHz) < 1,35 < 1,70 < 2,59 Harmonic attenuation up to 1,2 GHz > 50 up to 3 GHz (with low-pass filter) > 50 Group delay variation (ns) < 250 ns < 350 ns < 450 ns Temperature stability (khz/k)* <2 Input and output connectors DIN 7/16 female (default) EIA 7/8" Weight (kg) 8,5 11,5 Dimensions (mm) 304 x 173 x 194 386 x 173 x 194 conventional heat sink Critical mask with 6 cavity filter is achieved with ELTI transmitters BF4-6C550D-N BF4-6C550D-C Insertion and Return loss BF4-6C550D-C

Specifications UHF non-critical & critical mask up to 1,5 kw rms BF4-6C1K1D-N BF4-6C1K5D-N-HS BF4-6C1K1D-C BF4-6C1K5D-C-HS BF4-8C1K0D-C BF4-8C1K3D-C-HS Mask DVB non-critical mask critical mask critical mask Mask ISDB-T non-critical mask critical mask critical mask Number of cavities (elliptical response) 6 8 conventional cooling 1,1 kw rms 1 kw rms heat sink 1,5 kw rms 1,3 kw rms Return loss (db) > 26 > 21 > 26 f0 ± 4,2 MHz > 5 > 12 > 15 f0 ± 6 MHz > 16 > 24 > 26 f0 ± 12 MHz > 41 > 34 > 51 Center frequency (f0) < 0,38 < 0,45 < 0,52 f0 ± 3,805 MHz) < 1,25 < 1,50 < 1,90 Harmonic attenuation up to 1,1 GHz > 50 up to 3 GHz (with low-pass filter) > 50 Group delay variation (ns) < 250 ns < 350 ns < 450 ns Temperature stability (khz/k)* < 2 Input and output connectors DIN 7/16 female (default) EIA 7/8" EIA 1 5/8" Weight (kg) 13 17,5 Dimensions (mm) 386 x 240 x 245 502 x 240 x 245 conventional heat sink Critical mask with 6 cavity filter is achieved with ELTI transmitters BF4-6C1K1D-N BF4-6C1K1D-C Insertion and Return loss BF4-6C1K1D-C

Specifications UHF non-critical & critical mask up to 7,5 kw rms BF4-6C2K5D-N BF4-6C7K5D-N-LC BF4-6C2K5D-C BF4-6C7K5D-C-LC BF4-8C2K5D-C BF4-8C7K5D-C-LC Mask DVB non-critical mask critical mask critical mask Mask ISDB-T non-critical mask critical mask critical mask Number of cavities (elliptical response) 6 8 conventional cooling 2,5 kw rms heat sink 7,5 kw rms Return loss (db) > 26 > 21 > 26 f0 ± 4,2 MHz > 5 > 12 > 15 f0 ± 6 MHz > 16 > 24 > 26 f0 ± 12 MHz > 41 > 34 > 51 Center frequency (f0) < 0,32 < 0,37 < 0,49 f0 ± 3,805 MHz) < 1,00 < 1,30 < 1,59 Harmonic attenuation up to 1,2 GHz > 50 up to 3 GHz (with low-pass filter) > 50 Group delay variation (ns) < 250 ns < 350 ns < 450 ns Temperature stability (khz/k)* < 2 Input and output connectors EIA 1 5/8" (default) EIA 3 1/8" Weight (kg) 33 44 Dimensions (mm) 474 x 380 x 390 622 x 380 x 390 conventional liquid cooling (6 l/min) Critical mask with 6 cavity filter is achieved with ELTI transmitters BF4-6C2K5-N BF4-6C2K5-C Insertion and Return loss for filters with critical mask

Specifications UHF non-critical & critical mask up to 12,5 kw rms BF4-6C5K0D-N BF4-6C12K5D-N-LC BF4-6C5K0D-C BF4-6C12K5D-C-LC BF4-8C4K5D-C BF4-8C11KD-C-LC Mask DVB non-critical mask critical mask critical mask Mask ISDB-T non-critical mask critical mask critical mask Number of cavities (elliptical response) 6 8 conventional cooling 5 kw rms 4,5 kw rms heat sink 12,5 kw rms 11 kw rms Return loss (db) > 26 > 21 > 26 f0 ± 4,2 MHz > 5 > 12 > 15 f0 ± 6 MHz > 16 > 24 > 26 f0 ± 12 MHz > 41 > 34 > 51 Center frequency (f0) < 0,25 < 0,30 < 0,38 f0 ± 3,805 MHz) < 0,70 < 0,92 < 1,14 Harmonic attenuation up to 3 GHz (with low-pass filter) > 50 Group delay variation (ns) < 250 ns < 350 ns < 450 ns Temperature stability (khz/k)* < 2 Input and output connectors EIA 3 1/8" (default) EIA 4 1/2" Weight (kg) 58 77,5 Dimensions (mm) 654 x 500 x 430 862 x 500 x 430 conventional liquid cooling (10 l/min) Critical mask with 6 cavity filter is achieved with ELTI transmitters BF4-6C5K0D-N BF4-6C5K0D-C Insertion and Return loss for filters with critical mask

BF4-6C5K5D-N BF4-6C8K0D-N-HS BF4-6C15KD-N-FA BF4-6C18KD-N-LC Mask DVB Mask ATSC Mask ISDB-T Number of cavities (elliptical response) Bandwidth Conventional cooling Heat Sinks Forced Air Liquid Return loss (db) Selectivity (db) f0 ± 4,2 MHz f0 ± 6 MHz f0 ± 12 MHz Insertion loss (db) Center frequency (f0) f0 ± 3,8 MHz f0 ± 3,9 MHz Harmonic attenuation (db) up to 3 GHz Group delay variation (ns) Temperature stability Input and output connectors Max. Operating Temperature Weight (kg) Dimensions (mm) Option BF4-8C5K0D-C BF4-8C7K5D-C-HS BF4-8C14KD-C-FA BF4-8C16KD-C-LC 470 790 MHz Non Critical Mask Full Mask Non Critical Mask Critical Mask Full mask Critical Mask 6 8 5,5 kw rms / 8,25 kw p.s. 8,0 kw rms / 12,0 kw p.s. 15,0 kw rms / 22,5 kw p.s. 18,0 kw rms / 27,0 kw p.s. 5,0 kw rms / 7,5 kw p.s. 7,5 kw rms / 11,2 kw p.s. 14,0 kw rms / 21,0 kw p.s. 16,0 kw rms / 24,0kW p.s. > 23,1 db >4 > 20 > 41 @470 MHz < 0,22 db < 0,65 db < 0,75 db @790 MHz < 0,28 db < 0,90 db < 1,05 db @470 MHz < 0,30 db < 1,20 db < 1,40 db > 14 > 30 > 51 @790 MHz < 0,40 db < 1,70 db < 1,95 db > 50 < 400 ns < 800 ns < 2 khz/k EIA 3 1/8" socket (default) EIA 3 1/8 flange EIA 4 1/2" socket EIA 4 1/2" flange 65 C 58 78 714 x 550 x 405 943 x 550 x 405 conventional heat sinks add-on forced air liquid cooling (10 l/min) 70 C N.C. Thermoswitch Insertion and Return loss for filters with critical mask Specifcations UHF non-critical & critical mask up to 18 kw r ms