High Precision Positioning Mechanisms for a Hard X-ray Nanoprobe Instrument. Abstract

Similar documents
High-Precision Positioning Mechanism Development at the Advanced Photon Source

Mechanical Design of an Ultra-High-Vacuum Compatible Compact Hard X-ray Monochromator with Artificial Channel-Cut Crystal Mechanism

Nano Beam Position Monitor

FIRST INDIRECT X-RAY IMAGING TESTS WITH AN 88-mm DIAMETER SINGLE CRYSTAL

RANDY W. ALKIRE, GEROLD ROSENBAUM AND GWYNDAF EVANS

OPTICS IN MOTION. Introduction: Competing Technologies: 1 of 6 3/18/2012 6:27 PM.

Air Bearing Monochromator at APS 13-ID-E (GSECARS)

Fabrication, testing, and performance of a variable-focus x-ray compound lens

Fast Tip/Tilt Platform

Measurement and compensation of displacement errors by non-stop synchronized data collection

Optical Microscope. Active anti-vibration table. Mechanical Head. Computer and Software. Acoustic/Electrical Shield Enclosure

Fiber Optic Device Manufacturing

Measurement of Microscopic Three-dimensional Profiles with High Accuracy and Simple Operation

Shenglan Xu. GM/CA CAT Argonne National Laboratory

A fine tool servo system for global position error compensation for a miniature ultra-precision lathe

Application Note: Precision Displacement Test Stand Rev A

NanoFocus Inc. Next Generation Scanning Probe Technology. Tel : Fax:

Synchronization Control Scheme for Hybrid Linear Actuator Based on One Common Position Sensor with Long Travel Range and Nanometer Resolution

1. Introduction X-ray absorption fine structure (XAFS) is an element-specific powerful technique for chemical analysis. In general, XAFS spectra are o

Manufacturing Metrology Team

The New ID11 Nanoscope end-station A Nano-Tomography Scanner

VIBRATING WIRE SENSORS FOR BEAM INSTRUMENTATION Suren Arutunian

Overview of performance and improvements to fixed exit double crystal monochromators at Diamond. Andrew Dent, Physical Science Coordinator, DLS

Machine Tools with an Enhanced Ball Screw Drive in Vertical Axis for Shaping of Micro Textures

Supplementary Information

Fast Optical Form Measurements of Rough Cylindrical and Conical Surfaces in Diesel Fuel Injection Components

PIHera Piezo Linear Precision Positioner

Niklas Norrby 12/17/2010

INDIAN INSTITUTE OF TECHNOLOGY BOMBAY

Uncertainty in measurements of micro-patterned thin film thickness using Nanometrological AFM - Reliability of parameters for base straight line -

Laser Telemetric System (Metrology)

Microspot x-ray focusing using a short focal-length compound refractive lenses

X-Ray Beam Position Monitor Based on a Single Crystal Diamond Performing Bunch by Bunch Detection

Performance of Microchannel Plates Fabricated Using Atomic Layer Deposition

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

Active Vibration Isolation of an Unbalanced Machine Tool Spindle

Fast Widely-Tunable CW Single Frequency 2-micron Laser

Upgrade of the ultra-small-angle scattering (USAXS) beamline BW4

MEMS for RF, Micro Optics and Scanning Probe Nanotechnology Applications

Q-Motion Miniature Linear Stage

Compact Nanopositioning System Family with Long Travel Ranges

Outline: Introduction: What is SPM, history STM AFM Image treatment Advanced SPM techniques Applications in semiconductor research and industry

Prepare Sample 3.1. Place Sample in Stage. Replace Probe (optional) Align Laser 3.2. Probe Approach 3.3. Optimize Feedback 3.4. Scan Sample 3.

Development of a Vibration Measurement Method for Cryocoolers

PicoMaster 100. Unprecedented finesse in creating 3D micro structures. UV direct laser writer for maskless lithography

Stability of a Fiber-Fed Heterodyne Interferometer

Nanonics Systems are the Only SPMs that Allow for On-line Integration with Standard MicroRaman Geometries

CESRTA Low Emittance Tuning Instrumentation: x-ray Beam Size Monitor

Optical cesium beam clock for eprtc telecom applications

Nanovie. Scanning Tunnelling Microscope

Historical. McPherson 15 Mount

Today s Outline - January 25, C. Segre (IIT) PHYS Spring 2018 January 25, / 26

P-611.Z Piezo Z-Stage

A LARGE COMBINATION HORIZONTAL AND VERTICAL NEAR FIELD MEASUREMENT FACILITY FOR SATELLITE ANTENNA CHARACTERIZATION

Basic methods in imaging of micro and nano structures with atomic force microscopy (AFM)

New Long Stroke Vibration Shaker Design using Linear Motor Technology

- Near Field Scanning Optical Microscopy - Electrostatic Force Microscopy - Magnetic Force Microscopy

Pound-Drever-Hall Locking of a Chip External Cavity Laser to a High-Finesse Cavity Using Vescent Photonics Lasers & Locking Electronics

Park NX-Hivac The world s most accurate and easy to use high vacuum AFM for failure analysis.

Contents: Movement & Positioning News M&P 23, 1997, Text Only Version

Development of the accelerometer for cryogenic experiments II

CATALOG No. US FORMTRACER CS Hybrid Surface Contour Measuring Machine

Nanoscale Material Characterization with Differential Interferometric Atomic Force Microscopy

Scanning Ion Conductance Microscope ICnano

Advanced Nanoscale Metrology with AFM

Laser Locking with Doppler-free Saturated Absorption Spectroscopy

Diamond X-ray Rocking Curve and Topograph Measurements at CHESS

FemtoFAB. Femtosecond laser micromachining system. tel fax Konstitucijos ave. 23C LT Vilnius, Lithuania

Vibrating Wire R&D for Alignment of Multipole Magnets in NSLS-II

PiezoMike Linear Actuator

Vibration-compensated interferometer for measuring cryogenic mirrors

Workshop IGLEX Andromède & ThomX 23 June 2016, LAL Orsay. The X-line of ThomX.

Installation and Characterization of the Advanced LIGO 200 Watt PSL

plasmonic nanoblock pair

Akiyama-Probe (A-Probe) guide

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

First test experiments with FMB- Oxford direct drive DCM at the Sirius beamline of Synchrotron SOLEIL

NSOM (SNOM) Overview

Wavelength Control and Locking with Sub-MHz Precision

First results of a high performance optically-pumped cesium beam clock

50 MHz Voltage-to-Frequency Converter

<NOTICE> <PREAMB> BILLING CODE 3510-DS-P DEPARTMENT OF COMMERCE. International Trade Administration. University of Colorado Boulder, et al.

DCS laser for Thomson scattering diagnostic applications

COMPARISON OF DIFFERENT MAGNETIC MEASUREMENT TECHNIQUES.

x-ray Beam Size Monitor

Introduction of New Products

Scanning Tunneling Microscopy

LUSI Pulse Picker System

Introduction... 3 Slits for AIR Operation... 4 Slits in Vacuum Vessels... 5 Slits for High Vacuum Operation... 6 Custom Slits... 7 Steel Slits...

Cutting-edge Atomic Force Microscopy techniques for large and multiple samples

Ion Beam Lithography next generation nanofabrication

The AEI 10 m Prototype. June Sina Köhlenbeck for the 10m Prototype Team

M-041 M-044 Tip/Tilt Stage

Optical generation of frequency stable mm-wave radiation using diode laser pumped Nd:YAG lasers

Characterization of Silicon-based Ultrasonic Nozzles

membrane sample EUV characterization

Why Nanopositioning is More than Just Nanometers or How to Find a State-of-the-Art System

Introduction to High-Resolution Accelerator Alignment Using X-ray Optics

LIGO PROJECT. Piezo-Electric Actuator Initial Performance Tests. Eric Ponslet April 13, Abstract

The Latest Status of NSLS-II Insertion Devices

Transcription:

High Precision Positioning Mechanisms for a Hard X-ray Nanoprobe Instrument D. Shu, J. Maser,, B. Lai, S. Vogt, M. Holt, C. Preissner, A. Smolyanitskiy,4, R. Winarski, and G. B. Stephenson,3 Center for Nanoscale Materials, Argonne National Laboratory, Argonne, IL 439, U.S.A. Experimental Facilities Division, Argonne National Laboratory, Argonne, IL 439, U.S.A. 3 Materials Sciences Division, Argonne National Laboratory, Argonne, IL 439, U.S.A. 4 ECE Department, Illinois Institute of Technology, Chicago IL U.S.A. Abstract A hard x-ray nanoprobe beamline is being developed at the Advanced Photon Source (APS). The beamline will house a hard x-ray nanoprobe instrument, one of the centerpieces of the characterization facilities of the Center for Nanoscale Materials (CNM) at Argonne National Laboratory (ANL). The nanoprobe instrument will operate with photon energies between 3 kev and 3 kev with 3 nm special resolution initially. Imaging and spectroscopy at this resolution level require staging of x-ray optics and specimens with a mechanical repeatability of better than nm []. The instrument will combine a scanning probe mode with a full-field transmission mode. It uses x-ray fluorescence for trace-element mapping and spectroscopy; x-ray diffraction to obtain local structural information such as crystallographic phase, strain texture, and x-ray transmission in phase; and absorption to image internal structures of complex devices. The high-precision positioning mechanisms for the nanoprobe presented here consist of the following major component groups: a granite base with vibration isolators, an optomechanical instrument vacuum chamber, a robotic detector manipulator for microdiffraction, an in situ optical microscope, and a translation-stage system for a transmission imaging detector []. Precision positioning mechanisms for a differential scanning stage system with active vibration control in nanometer scale are also presented in this paper. Outline Introduction Laser Doppler encoder with multiple-reflection optics --- Technique for measurement in sub-nanometer scale High-stiffness weak-link for linear motion reduction mechanism --- Technique for motion in sub-nanometer scale Real-time closed-loop feedback for active vibration control in nanometer scale Design of a hard x-ray nanoprobe prototype tested at XOR 8-ID Design of a hard x-ray nanoprobe instrument for CNM at APS sector Positioning stage and encoder systems in central instrument chamber Instrument chamber and invar reference base Active vibration control in nanometer scale Supporting stages for fluorescence, transmission and diffraction detector systems Summary

Laser Doppler encoder with multiple-reflection optics Since 998 a prototype laser Doppler linear encoder (LDLE) with multiple reflections has been under development at the APS. With a customized commercial laser Doppler displacement meter (LDDM), this novel linear encoder achieved sub--pm sensitivity in a 3-mm measuring range. The LDDM is based on the principles of radar, the Doppler effect, and optical heterodyning. We have chosen a LDDM as our basic system, not only because of its high resolution ( nm typically) and fast object speed ( m/s), but also because of its unique performance independent of polarization, which provides the convenience to create a novel multiple-reflection-based optical design to attain sub--pm linear resolution. Laser Doppler encoder with multiple-reflection optics In the self-aligning multiple-reflection optical design for the LDDM system, the heterodyning detector is housed coaxially inside the frequency-stabilized laser source. Instead of a typical single reflection on the moving target, the laser beam is reflected back and forth twelve times between the fixed base and the moving target. The laser beam, which is reflected back to the heterodyning detector, is frequency-shifted by the movement of the moving target relative to the fixed base. With same LDDM laser source and detector electronics, this optical path provides twelve times greater resolution for the linear displacement measurement and encoding. A.3 nm resolution was reached by the prototype LDDM system recently.

Weak-link mechanism for high-energy-resolution x-ray monochromator Fixed crystal holder Base Picomotor Pitch and roll Adjustable crystal holder Picomotor Sine-bar with PZT holder Weak-link mechanism Unlike traditional kinematic linear spring mechanisms, the overconstrained weak-link mechanism provides much higher structural stiffness and stability. Using a laminar structure configured and manufactured by chemical etching and lithography techniques, we are able to design and build a planar-shape, high-stiffness, high-precision weak-link mechanism. The precision of modern photochemical machining processes using lithography techniques makes it possible to construct a strain-free (or strain-limited) overconstrained mechanism on thin metal sheets. By stacking these thin-metal weak-link sheets with alignment pins, we can construct a solid complex weak-link structure for a reasonable cost. Top of the stage Weak-link mechanism Base of the stage PZT Using the same technique described in the section for the weak-link mechanism for a high-energy- resolution monochromator, we have developed a novel stage using a high-stiffness weak-link mechanism to perform linear motion closed-loop control at the sub--pm level with micron-level travel range. The structure consists of four groups of overconstrained weak-link parallelogram mechanisms made with lithography techniques. Driving sensitivity better than 3 pm was demonstrated with this weak-link linear-motion-reduction mechanism with a -micron travel range. A one-dimensional linear actuator system with subnanometer closed-loop control resolution and centimeters travel range AFM head Laser head Multiple-reflection Optics enclosure DC-motor stage Laser head A one-dimensional linear actuator system based on the above high-stiffness weak-link technique and LDDM with multiple-reflection optics has been tested. This photo shows the one-dimensional laser Doppler linear actuator (LDLA) system for an atomic force microscope. In this coarse/fine closed-loop control setup, a PZT-driven motion-reduction mechanism was mounted on the top of a DC-motor-driven stage to drive the motion object (in this example, a sample holder for an atomic force microscope).

A one-dimensional linear actuator system with subnanometer closed-loop control resolution and centimeters travel range A laser Doppler displacement meter with an optical resolution extension assembly was used to measure the sample holder motion in the 5-mm range with sub--pm resolution. The LDDM position signal is fed back through a system-control computer to control the PZT. The PZT drove the motion-reduction mechanism with sub--pm resolution to stabilize the motion. The system control computer also synchronized the stage position and PZT feedback lock-in point with the LDDM position signal. A one-dimensional linear actuator system with subnanometer closed-loop control resolution and centimeters travel range Displacement (nm) 98-57.9.8.7..5.4.3.. -. 3 4 5 7 Displacement (nm) 447-5534.5.4.3.. -. 5 5 5 3 35 Resolution test of the one-dimensional laser Doppler linear actuator closed-loop control system. A series of -pm (left side) and 8-pm (right side) steps have been demonstrated.

Design of an X-ray Nanoprobe Prototype Design of an x-ray nanoprobe prototype We started the x-ray nanoprobe prototype online commissioning in August 3. These are photographs of the prototype at the APS 8-ID-E experimental station (left) and in a test laboratory (right).

Design of an x-ray nanoprobe prototype Vertical Differential Displacement (nm) 5 4 3 - - 5 5 Horizontal Differential Displacement (nm) 5 5-5 3 3 34 3 38 4 4 44 Closed-loop differential displacement test for the prototype scanning stage system for the x-ray nanoprobe at the APS 8-ID-E station, horizontal: left side; vertical: right side. A series of -nm and 3-nm differential vertical and horizontal displacement steps (between zone-plate holder and sample holder) have been demonstrated with closed-loop control. Vertical Differential Displacement (nm) 3.5.5.5 -.5 - -.5 - -.5 3 4 5 7 Horizontal Differential displacement (nm) 4 - -4 - -8 3 4 5 7 8 Active vibration control test for the prototype scanning stage system for the x-ray nanoprobe at the APS 8-ID-E station, vertical: left side; horizontal: right side. During this test, the closed-loop control system performed a damping action to a single external mechanical disturbance (an 8-kg mass dropped to the floor from a.-m height at a distance of 3 m). General layout design 3 4 5 9 8 7 Top view of the hard x-ray nanoprobe instrument. () Ion pump; () Incident beam; (3) Instrument Chamber; (4) Laser head for LDDM; (5) Diffraction detector; () Transmission imaging detector; (7) Isolators below base; (8) Granite base; (9) Airlock for specimen exchange; () Fluorescence detector.

General layout design 3 4 5 7 Side view of the hard x-ray nanoprobe instrument. () Incident beam; () Instrument chamber; (3) Optical microscope; (4) Diffraction detector; (5) Transmission imaging detector; () Granite base; (7) Isolators. Positioning stage and encoder systems in central instrument chamber 3 4 5 7 Left: A schematic side view of the nanoprobe instrument chamber. () Vacuum chamber; () CM; (3) FOM; (4) SM; (5) Beryllium window; () IOM; (7) Invar reference base. Right: A 3-D model of the nanoprobe instrument chamber.

Positioning stage and encoder systems in central instrument chamber Scanning stages for focusing optics module To optimize the motion straightness of trajactory, three piezo actuators are used in parallel on the vertical flexure stage. Two piezo actuators are used on the horizontal stage. This design provides more than x higher structural stiffness than commercial D stages (such as PI-5), and, due to the composite nature of the flexure hinges, better vibration damping. The resolution of the stage is.3 nm with a travel range of 5 microns. Physik Instrumente TM PZT actuators with strain-gauge sensor servo-control modules were used to drive both high- and mediumresolution weak-link stages.

Laser Doppler encoders for differential D positioning and active vibration control 4 5 3 Schematic of the six-lddm encoder system for the two-dimensional differential position encoding between the FOM and SM. () Prism holder for zone-plate optics; () Prism holder for sample stage; (3) Sample location; (4) Zone-plate optics locations; (5) Prism on the stage; () Prism group on the reference frame. Laser Doppler encoders for differential D positioning and active vibration control Schematic of differential positioning feedback control in the vertical (Y) direction. For the differential feedback positioning control in the vertical (Y) direction, two LDDMs are applied to the FOM and SM in the Y direction. Since the reference frame defines the coordinate system of the nanoprobe, all positions are measured with respect to this frame. To perform a differential measurement between the stage groups for FOM and SM in the Y direction, a DSP-based feedback control computer is used as a control console to collect the position information from the three LDDMs with a positioning update rate of 937 khz. The DSP computes the position differences between the two stage groups and determines the discrepancy between the actual and desired differential position between the zone-plate optics and sample, and feeds back differential position-correction signals through a proportional-integral-derivative (PID) loop to the PZT-driven weak-link stage on the FOM. Differential scanning motion can be activated by controlling the desired differential position value. In the case of large-range scanning activity, a relay mechanism is implemented into the control software to ensure a smooth transition between the PZT-driven weak-link fine stage and the DC-motor-driven coarse translation stage.

SUMMARY This presentation provides a overall view of the precision engineering approach for a design for the CNM Hard x-ray Nanoprobe instrument based on a combined scanning probe/full-field transmission instrument. The engineering design presented takes into consideration the experience gained from developing a high-precision staging system for the CNM Early User Instrument. It builds on a modified mechanical design of the optics staging, a modified layout of the encoder system, and a different strategy for instrument controls. Acknowledgments --------------------------------------------------------------------------------------------------------------- Many thanks to: M. Muscia (ANL), A. Nyman (ANL), D. Nocher (ANL), R. Ranay (ANL), C. Jacobsen (NSLS), Y. Dabin (ESRF), J. Susini (ESRF), T. Warwick (ALS), T. Tyliszczak (ALS), and J. Kirz (ALS). This work was supported by the U.S. Department of Energy, Office of Science, under Contract No. W-3-9-Eng-38. References [] J. Maser, G. B. Stephenson, D. Shu, B. Lai, S. Vogt, A. Khounsary, Y. Li, C. Benson, G. Schneider, SRI 3 Conf. Proc., 75, AIP (4) 47-473. [] D. Shu, J. Maser, B. Lai, S. Vogt, M. Holt, C. Preissner, A. Smolyanitskiy, B. Tieman, R. Winarski, and G. B. Stephenson, to be published in the proceedings of X-ray M icroscopy 5, Himeji, Japan, July 5. [3] LDDM is a trademark of the Optodyne Inc., 8 Mahalo Place, Compton, CA 9, U.S.A. [4] U.S. Patent granted No. 5,89,, D. Shu, 999. [5] U.S. Patent granted No.,8,733, D. Shu, 4. [] D. Shu, T. S. Toellner, and E. E. Alp, Nucl. Instrum. Methods A 47-48, 77-774 (). [7] U.S. Patent granted No.,7,84, D. Shu, T. S. Toellner, and E. E. Alp, 3. [8] D. Shu, J. Maser, B. Lai, and S. Vogt, SRI 3 Conf. Proc., 75, AIP (4) 87-9. [9] D. Shu, J. Maser, B. Lai, S. Vogt, M. Holt, C. Preissner, A. Smolyanitskiy, R. Winarski, and G. B. Stephenson, High Precision Positioning Mechanisms for a Hard X-ray Nanoprobe Instrument, to be published in the AIP Proceedings of SRI. [] D. Shu, T. S. Toellner, E. E. Alp, J. Maser, J. Ilavsky, S. D. Shastri, P. L. Lee, S. Narayanan, and G. G. Long, Applications of Laminar Weak-Link Mechanisms for Ultraprecision Synchrotron Radiation Instruments, to be published in the AIP Proceedings of SRI.