Heckmann Building Products Inc. DOVETAIL SLOT AND ANCHORS SPECIFICATION SECTION MASONRY ANCHORS AND ACCESSORIES PART 1 GENERAL

Similar documents

2008 Our 85th Year! /HEC BuyLine 3160

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

SECTION THERAPEUTIC POOL ACCESSORIES

Testing. Material testing will be according to applicable AASHTO, ASTM or Department methods as specified.

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

Design and Construction Standards SECTION ATHLETIC LOCKERS

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

SECTION BULLET- RESISTANT DOORS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION METAL FABRICATIONS

1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards.

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

A. It is preferred that all submittals to be submitted electronically in PDF format.

PART MATERIALS. Section Fencing Materials. Description

SECTION TRAFFIC SIGNAGE

ALUMINUM PIPE GUIDERAIL 01/01/

Product Guide Specification

SECTION MASONRY ANCHORAGE AND REINFORCEMENT. Display hidden notes to specifier. (Don't know how? Click Here)

Project: # Solano Community College District

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

FASTENERS C O M P AT I B L E W I T H F E R O T I E S Y S T E M S. Which FERO Tie Systems Require Fasteners?

DIVISION 6 WOOD AND PLASTICS

AMBICO Limited Section and WOOD BULLET RESISTANT DOORS AND FRAMES Page 1

MH Series Mitered Frames shall be as manufactured or furnished by Republic Doors and Frames, McKenzie, Tennessee

STEEL PIPE GUIDERAIL 01/01/

SECTION HOLLOW METAL DOORS AND FRAMES

SPRINGLOK SPRINGLOK FLASHING SYSTEM PRODUCT BROCHURE ENGINEERED PRODUCT SYSTEMS

SECTION CONCRETE REINFORCEMENT FOR STEAM UTILITY DISTRIBUTION

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

SECTION BATHROOM ACCESSORIES

3.1 General Provisions

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

OSE Submittal July 20, 2018

SUBMITTAL SHEET. Project Submittals by

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION SHEET METAL FLASHING AND TRIM

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

SHEET METAL FLASHING AND TRIM Christ on the Mountain

Collins Engineers Palmetto Islands County Park Boardwalk Repairs 03/28/2014 SECTION ROUGH CARPENTRY

A. Rough carpentry includes but is not limited to the following:

WAL-MART SUPERCENTER # ; Milwaukie, OR: SPECIFICATIONS. Revisions to Specification Fence

SECTION HOLLOW METAL DOORS AND FRAMES

1.1 RELATED DOCUMENTS

SECTION CONCRETE ANCHORING. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION 10. SAFETY METHODS FOR TURNBUCKLES

B. See Division 05 Section "Pipe and Tube Railings" for metal pipe and tube railings.

SECTION STRUCTURAL STEEL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

APPENDIX FENCE GENERAL NOTES

Multi-Institutional Academic Health Science & Research Center Evansville, IN

SECTION SHEET METAL FLASHING AND TRIM

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: MiTek USA, INC.

UFGS (November 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

FT DIX ELEMENTARY SCHOOL PHASE VII, CLASSROOM ADDITION PEMBERTON TOWNSHIP REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5349A

SECTION ROUGH CARPENTRY 1.1 DESCRIPTION OF WORK:

City of Regina Standard Construction Specification SECTION 2660 CHAIN LINK FENCE

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION CARPENTRY

UNIFIED FACILITIES GUIDE SPECIFICATIONS

A. Columns: Worthington Millwork; Cellular Polyvinyl Chloride (PVC) columns; decorative, weatherproof, insect-proof, and highly durable.

D. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

10x12 FOUNDATION GUIDE 10x12 TRICO AND FLORA SHEDS

ULT R A S PACE SAV E R SQ UA R E D

A. Product Data: For each type of process and factory-fabricated product indicated.

Subject: Specification Compliance

Khathij Industrial Fasteners

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION MANUFACTURED CASEWORK

Toll-Free

50948-RHN Putney. 06 January This document includes: Aluminium strip/ sheet coverings/ flashings 1. Code Section Revision Dated

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

DECKS. Stairway illumination Positive attachment of ledger Lateral load connection required board (R507.2) required (R ) (R311.7.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION FRAMELESS GLASS SLIDING BI-FOLD SHOWER DOOR HARDWARE

S W E RV E RAC K. Simple Security. Simple Stability.

ESR-1799 Reissued April 2014 This report is subject to renewal June 1, 2015.

B. Products furnished, but not installed, under this Section include the following:

A. Compatibility: Products shall be suitable for piping service fluids, materials, working pressures, and temperatures.

GloEx Product List Assessment-Nail Selection

Nails, Fasteners, Connectors, and Framing

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes

Standard Specification for Fence Fittings 1

C. HMMA 863: Guide Specifications for Detention Security Hollow Metal Doors and Frames

Timber to Timber - Timber to Concrete - Timber to Steel

Attachment of Residential Deck Ledger to Side of Metal Plate Connected Wood Truss Floor Ladder. Installation Instructions Revised 9/2/2016

UFGS (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Sigma Fasteners, Inc. Section 7

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

AUXILIARY FRAMING AND ACCESSORIES

SECTION ROUGH CARPENTRY

1. Division 6 Section "Rough Carpentry" for furring, blocking, and other carpentry work that is not exposed to view.

Installation Instructions

Modular Gazebo Kit Series GardenHouse 12

A. Radius elbows with a construction radius of 1.5 the duct width are preferred to square elbows.

SECTION CHAIN LINK FENCING AND GATES

Transcription:

Heckmann Building Products Inc. DOVETAIL SLOT AND ANCHORS SPECIFICATION MASONRY ANCHORS AND ACCESSORIES PART 1 GENERAL SECTION 04085 1.1 SECTION INCLUDES NOTE: Delete items below not required for project. A. Masonry veneer anchors and ties. B. Stone veneer anchors and ties. C. Masonry accessories. 1.2 RELATED SECTIONS A. Section 04810 - Unit Masonry Assemblies. B. Section 04851 - Cut Stone Veneer. C. Section 04852 - Stone Masonry Veneer. 1.3 REFERENCES NOTE:Delete references from the list below that are not actually required by the text of the edited section. A. ASCE/ACI 530.1 Specifications for Masonry Structures;1995. B. ASTM A 153/A 153M - Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware; 1998. C. ASTM A 167 - Standard Specification for Stainless and Heat-Resisting Chromium-Nickel Steel Plate, Sheet, and Strip; 1996. D. ASTM A 240/A 240M - Standard Specification for Heat-Resisting Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels; 1998b. E. ASTM A 276 - Standard Specification for Stainless Steel Bars and Shapes; 1998b. F. ASTM A 479/A 479M - Standard Specification for Stainless and Heat-Resisting Steel Bars and Shapes

for Use in Boilers and Other Pressure Vessels; 1997a. G. ASTM A 580/A 580M - Standard Specification for Stainless Steel Wire; 1998. H. ASTM A 653/A 653M - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process; 1998. I. ASTM B 633 : Standard Specification for Electrodepositied Coatings of Zinc on Iron and Steel; (Reapproved 1994). 1.4 SUBMITTALS A. Submit under provisions of Section 01300. B. Product Data: Manufacturer's data on each type of product furnished. PART 2 PRODUCTS 2.1 MANUFACTURERS A. Acceptable Manufacturer: Heckmann Building Products.Inc., 1501 N. 31 st Avenue, Melrose Park, IL 60160 800-621-4140 or 708-865-2403 FAX: 708-865-2640 Email: info@heckmannanchors.com. Website: www.heckmannanchors.com. NOTE: Delete paragraph below; coordinate with Division 1 requirements. B. Requests for substitutions will be considered in accordance with provisions of Section 01600. C. Substitutions: Not permitted. 2.2 APPLICATIONS A. Provide anchoring systems that comply with ACI 530.1/ASCE 6/TMS 602. B:Dovetail Slots cast in forms. 1. Anchors to Concrete: ************************************************************ NOTE: Choose one of the following slot types ************************************************************

A. No. 100 Standard Dovetail Anchor Slot B. No. 100-A Large Dovetail Anchor Slot C. No. 100-B Small Dovetail Anchor Slot NOTE: The following masonry ties must be used with one or more of the anchor types listed above D. Masonry Veneer Seismic Ties: Continuous wire in mortar joint, anchored to one of the following: ************************************************************* Note: Delete all of the following types that are not required. 1. For Use with Dovetail Slots: No. 361 DOVETAIL SEISMIC ANCHOR [gage] x 1 inch (25 mm) wide x [length from face of concrete] E.Masonry Veneer Ties: Provide minimum 2 inches (50 mm) embedment in mortar. Note: Delete all of the following types that are not required. 2. For Use With Dovetail Slots: 103 DOVETAIL TRIANGLE TIE 12 gage clip factory assembled to a 3/16 inch (4.76 mm) diameter x [tie length] 104 DOVETAIL PARTITION ANCHOR [gage] x [width] x [length from face of concrete] 105 DOVETAIL STANDARD BRICK ANCHOR [gage] x 1 inch (25 mm) wide x 3-1/2 inch (89 mm) long. 106 DOVETAIL CORRUGATED ANCHOR [gage] x 1 inch (25 mm) wide x [length from face of concrete] 107 DOVETAIL WIRE BRICK ANCHOR 1/8 inch (3.17 mm) thick anchor furnished loose with No. 316 Triangle Ties 3/16 inch (4.76 mm) diameter x [tie length] 108 DOVETAIL CAVITY WALL ANCHOR [gage] x [width] x [length from face of concrete] 109 DOVETAIL FLAT ANCHOR [gage] x [width] x [length from face of concrete] 110 DOVETAIL FURRING ANCHOR [gage] x [width] x 1-1/2 inches (38.1 mm) long from face of concrete. 115 DOVETAIL STONE ANCHOR [gage] x [width] x [length from face of concrete] x [i.d. bend length] 116 DOVETAIL SPLIT END ANCHOR [gage] x [width] x [length from face of concrete] x [i.d. split-bend length]. 117 DOVETAIL SPLIT BEND ANCHOR [gage] x [width] x [length from face of concrete] x [i.d. split-bend length] 118 DOVETAIL STONE PIN ANCHOR [gage] x [width] x [length from face of concrete] with [welded][fixed][loose] pin [diameter] x [length] centered [length] from end of anchor 121 DOVETAIL THREADED ROD ANCHOR [gage] x [width] x [overall length from face of concrete] x [rod diameter]

3. Other Applications: Where details or installation conditions require, provide ties fabricated of shape and size to suit conditions and provide adequate anchorage. E. Stone Ties: Custom strap ties, fabricated to suit details and installation requirements. 1. For Anchoring Into Edge of Dimension Stone Panels: 115 DOVETAIL STONE ANCHOR [gage] x [width] x [length from face of concrete] x [i.d. bend length] 116 DOVETAIL SPLIT END ANCHOR [gage] x [width] x [length from face of concrete] x [i.d. split-bend length]. 117 DOVETAIL SPLIT BEND ANCHOR [gage] x [width] x [length from face of concrete] x [i.d. split-bend length] 118 DOVETAIL STONE PIN ANCHOR [gage] x [width] x [length from face of concrete] with [welded][fixed][loose] pin [diameter] x [length] centered [length] from end of anchor 2. Where not otherwise indicated, use anchoring method specified above. Note: Select one of the following 3 combinations of materials: all stainless steel, all hot-dip galvanized, or hot-dip galvanized except for items completely embedded in mortar. Delete the inappropriate choices. F. Material for Anchors and Ties in Exterior Walls: Stainless steel. 1.Exception: Structural Plates, Angles, and Bars: Hot-dip galvanized. G. Material for Anchors and Ties in Exterior Walls: Hot-dip Galvanized After Fabrication. H. Material for Anchors and Ties Exposed to Air in Exterior Walls: Hot-dip galvanized After Fabrication. 1. Exception: Dovetail Slots: Stainless steel. 2. Exception: Dovetail Slots: Mill galvanized steel. I. Material for Ties Completely Embedded in Mortar Joints: Mill galvanized. 2.3 MATERIALS A. Stainless Steel: Type 304. 1.Sheet Metal: ASTM A 167 or ASTM A 240/A 240M. 2.Wire: ASTM A 580/A 580M.

3.Bars: ASTM A 479/A 479M, annealed and ground. 4.Plates, Bars, and Shapes: ASTM A 167 or ASTM A 276. B. Hot-Dip Galvanized Steel: Hot-dip galvanized after fabrication in accordance with ASTM A 153/A 153M, Class B-2. 1.Wire: Minimum 3/16 inch (4.76 mm) diameter. C. Electro-Galvanized Steel: Electro-galvanized after fabrication in accordance with ASTM B 633, Service Condition 1. 1. Wire: Minimum 3/16 inch (4.76 mm) diameter. D. Mill Galvanized Steel: 1. Sheet Metal: ASTM A 653/A 653M, G60 coating. 2. Wire: ASTM A 641, regular coating; minimum 3/16 inch (4.76 mm) diameter. NOTE: Dovetail slots are available only in mill galvanized, hotdip galvanized, and stainless steel. Stainless steel available only in 26 gage For No. 100. Select one type of dovetail slot and delete the others. E. Dovetail Slots: Heckmann No. 100 STANDARD DOVETAIL ANCHOR SLOT 1. Size: 1 inch (25 mm) wide by 1 inch (25 mm) deep by 5/8 inch (16 mm) throat. 2. Metal Thickness: 20 gage (0.9 mm) 3. Metal Thickness: 22 gage (0.76 mm) 4. Metal Thickness: 24 gage (0.61 mm) 5. Metal Thickness: 26 gage (0.45 mm) **************************************************************** NOTE: Delete one of the following two paragraphs on ties. Be sure the tie style is listed above under Applications 1. Ties: 12 gage (2.6 mm) thick; style as indicated above. 2. Ties: 16 gage (1.5 mm) thick; style as indicated above. E. Dovetail Slots: Heckmann No. 100-A LARGE DOVETAIL ANCHOR SLOT. 1. Size: 2 inches (50 mm) wide by 1-1/2 inches (38 mm) deep by 1-3/8 inch (35 mm) throat. Note: Delete all but one of the following metal thicknesss.

1. Metal Thickness: 16 gage (1.5 mm). 2. Metal Thickness: 18 gage (1.2 mm). 3. Metal Thickness: 20 gage (0.9 mm). Note: Delete one of the following two paragraphs on ties. Be sure the style is listed above under Applications. 1. Ties: 12 gage (2.6 mm) thick; style as indicated above. 2. Ties: 16 gage (1.5 mm) thick; style as indicated above. E.Dovetail Slots: Heckmann No. 100-B SMALL DOVETAIL ANCHOR SLOT. 1. Size: 7/8 inch (22 mm) wide x ½" (13 mm) deep by 5/8 inch (16 mm) throat. 2. Metal Thickness: 20 gage (0.9 mm) Note: Delete one of the following two paragraphs on ties. Be sure the style is listed above under Applications. 1. Ties: 12 gage (2.6 mm) thick; style as indicated above. 2. Ties: 16 gage (1.5 mm) thick; style as indicated above. PART 3 EXECUTION 3.1 INSTALLATION A: Dovetail Anchor Slot: Nail filler side down to concrete forms. Nails should be placed every 12 inches (305 mm). Space Slots [vertically][horizontally] every [specify distance between slots]. B: Anchors: Insert anchor at desired height into Dovetail Anchor Slot. Turn 90 degrees to lock into the slot. Place mortar above and below anchor in the mortar joint. [Specify spacing of anchors]. END OF SECTION