Binary Inputs. Ref.-No. KNX universal binary input, 8-gang. ETS-product family: Series embodiment (SE-) device (2 units) Ref.-No.

Similar documents
instabus EIB product documentation

Width (W): 44 mm. bus connecting and branching terminal External supply --- Inputs: Number: up to 2 (depending on parameterization: channel 1 to 2)

Rev ABB i-bus KNX 6151/11 U-500. Power and productivity for a better world TM

Time Switch, 2-channel, MDRC SW/S 2.5, GH Q R0001

Technical data: Instabus EIB supply Voltage: YY 6 x 0.6 mm; red: bus (+) / black: bus (-)

Product Manual. ABB i-bus EIB / KNX. Universal Interface US/U Intelligent Installation Systems

The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal.

SeeTool - Solutions for KNX

Rev Product Manual ABB i-bus KNX. Heating actuator 1gang with 6164/11 U-500. Power and productivity for a better world TM

Installer manual inputs/outputs interface for led KNX

1. Use of the application program

KNX Room temperature controller

EIB/KNX Switch Actuators. User manual

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W

Shutter Actuator with Manual Operation, 4-fold, 230 V AC, MDRC JA/S M, GH Q R0111. ABB i-bus EIB / KNX

K-BUS Switch Actuator

Switch actuator. Movement detector Move/monitoring 1305/1.0, Art. No , ,

Instruction manual. art Installation manual

KNX manual 1-channel flush-mounted switch actuator SU 1

Thorsten Reibel, Training & Qualification Global Application and Solution Team

Use of the application program. Contents. instabus EIB Application program description. September S2 Room temperature controller

animeo KNX 4 AC Motor Controller 31. March 2016 WM/DRM V AC

MOTION DETECTOR WITH CONSTANT LIGHT CONTROL DM KNT 003

animeo KNX/EIB 4 AC Motor Controller WM/DRM V AC

Application Description

RAM 712 KNX room thermostat for surface-mounted and flush-mounted installation

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

ABB i-bus KNX Meter Interface Module, MDRC ZS/S 1.1. Product Manual. Intelligent Installations Systems ABB

Electrical devices may only be mounted and connected by electrically skilled persons.

For controlling 4 independent shutter or sunblind drives via ABB i-bus including the functions Up/Down, Step/Stop.

animeo KNX/EIB 4 DC/E Motor Controller WM V AC Installation manual

KNX Powerline PL 110. KNX Association

Fan Coil Actuator FCA 2

User Manual 3X300 DIMMER MODULE DM03B02KNX

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

KNX ON/OFF controller 4 contacts 16A

User manual. KNX MultiController DALI. Article number: 5410x / 5411x. function Technology AS

KNX manual High-performance switch actuators RM 4 H FIX1 RM 8 H FIX2

INSTABUS RADIO GATEWAY

animeo KNX 4 DCE Motor Controller WM/DRM V AC Instructions

Functions module / Gateways Application Description Product Page KNX-GW-DMX-xxx DMX Gateway. KNX-GW-DMX Product Group 1

animeo KNX 4 DC 2 A Motor Controller WM 24 V DC Installation manual

Unidirectional Gateway EnOcean - KNX/BUS

16-Channel Yearly Time Switch TR 648 S DCF

Use of the application program. Functional description. GAMMA instabus Application program description. October 2007

User Manual. KNX MultiLight Dali. Article number: function Technology AS. Picture: KNX MultiLight products

Use of the application program. Functional description. GAMMA instabus Application program description. May A8 Venetian blind actuator

ABB i-bus KNX Valve Drive Actuator VAA/S x Product Manual

USER MANUAL CU-DIN DIM 4-CH 1.5A KNX EC MA

application software

series dimmer actuators, DMG 2 S, Upgrade Module DME 2 S and Booster DMB 2

CU-DIN DIM 6-CH 0 10V KNX

theben Fan Coil Actuator FCA 1 Fan Coil Actuator FCA 1 FCA Version: Jan-08 (Subject to change) Page 1 of 77

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

STC-KNX (32-channel AP)

KNX ENO 634 (32-channel AP)

Technology X10 for Home Automation

Technical manual GS 4x.00 knx application description air quality sensor

The room thermostat application module with 2-fold switch sensor is placed on a flush-mounted bus coupler.

AL-DALI-010v 0-10v Dimmer 3-Way switch with DALI

Operating Instructions. Combination sensor

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Series Dimmer Actuator DMG 2, Upgrade Module DME 2 and Booster DMB 2 DMG DME DMB

MDT Switch Actuator/FanCoil

Electrical devices may only be mounted and connected by electrically skilled persons.

ABB i-bus. KNX Weather Station WS/S Product Manual

KNX ENO 620/622 (32-channel AP)

Electrical devices may only be mounted and connected by electrically skilled persons.

application software

TA-Slider 160 KNX Protocol Implementation

Combi sensor C B1. A: Wind wheel. west, east, south C: Dawn sensor D: Rain sensor. Ref.-No. with DCF77 receiver WS 10 KSDCF (No KNX device)

Smart-house Dimmer Power dimmer up to 500W Type SH2D500W230

Integrations GW Programming manual

Product documentation

4-Channel-Loop-Detector Euro-card plug-in 19"

gesis EIB V Manual Installation system for European Installation Bus Products and Objects description

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features

Instabus Radio Control Converter Installation Instructions

Technical Manual MDT LED-Indicator

theben 4-/8-/12-Channel Switch Module Switch Actuator Modular with Basic Device RMG 4 - EIB and Additional Device RME 4 EIB

KNX weather station basic V2

Multifunction Devices CIM1, CIM12, CIM13, CIM14

WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany

PRODUCT MANUAL. ABB i-bus KNX VC/S 4.x.1 Valve Drive Controller

Brief description. Type overview

Multi-function 11 pin Plug-in for use with 90 series sockets

» Minimal and maximal levels can be set on site. The bus coupling unit enables to use the values in the KNX-Bus.

HDL KNX / EIB BUS. Dimmer Actuator. 1/43. Light Technology Nederland ditributor of HDL

IMPULSE SWITCH, REMOTE SWITCH

ABB i-bus KNX Energy Actuator SE/S Product Manual

Overview animeo KNX offer

Sentido KNX Manual. Sentido KNX. Manual. basalte bvba hundelgemsesteenweg 1a 9820 merelbeke belgium

83 Series - Modular timers 16 A. Features

How to Guide: Controlling Blinds in C-Bus

ABB i-bus KNX Energy Actuator SE/S Product Manual

ABB i-bus KNX DALI Light Controller DLR/S M Product Manual

Operation with the Tebis TX100 configurator

application software

Multi-voltage Multi-function. Wiring diagram (without control signal)

TA-Slider 160 KNX R24 Protocol Implementation

Transcription:

Binary s 1 L1 L2 L3 N E1 N1 E2 N2 E3 N3 E4 N4 KNX + - 2 1 KNX universal binary input, 4-gang ETS-product family: Product type: Series embodiment (SE-) device (2 units) Ref.-No. 2114 REG 4-gang binary input 2 KNX universal binary input, 8-gang ETS-product family: Product type: Series embodiment (SE-) device (4 units) Ref.-No. 2118 REG 8-gang binary input 3 With its 4 (8) independent inputs, this binary input can collect 230 V signals and send messages to the KNX, depending on the parameter setting. These can, for example, be messages for switching, dimming (single-level or two-level operation) or for blind/shutter control. Also, it is possible to program certain functions such as dimming value transmitter, light scene extension as well as temperature or brightness transmitter, respectively. Various functions can be assigned to the 4 (8) inputs. In addition, inputs 1 and 2 can be parameterised with pulse or switching counter functions. Finally, the binary input offers a blocking function to enable or disable certain inputs. 107

Universal binary input Ref.-No. 2114 REG, 2118 REG 4 Technical data Supply Voltage: 24 V DC (+6 V / -4 V) Power consumption: 2114 REG: 10 mw 2118 REG: max. 240 mw Connection: KNX connection block Number 2114 REG: 4 2118 REG: 8 Signal voltage Signal current 110 V 230 V AC ± 10 %; 0/60 Hz approx. 7 ma at 230 V AC per input (max. glow discharge lamp current < 2 ma for reliable "0" recognition) Signal length for pulse Tmin. = 200 ms at a mark-to-space ratio of 1:1 0 -signal 0 70 V AC 1 -signal > 90 V AC line length 100 m max. (unshielded) Connection: clamp bar Behaviour at voltage drop only bus voltage no reaction only mains a falling edge is detected; this response depends on the parameters bus and mains no reaction Behaviour at voltage recovery only bus voltage dependent on parameters only mains a rising edge is detected; this response depends on the parameters bus and mains dependent on parameters Protection: IP 20 Operation temperature: C... +4 C Storage temperature: 2 C... +70 C Mounting: on DIN rail 3 x 7. Notes: Different lines can be connected to the device. 108

Universal binary input Ref.-No. 2126 REG 1 24 V AC/DC GND E1 E2 E3 1-3 E4 E E6 4-6 E1 E2 E3 E4 E E6 KNX + - 2 KNX universal binary input, 6-gang ETS-product family: Product type: Series embodiment (SE-) device (2 units) Ref.-No. 2126 REG 6-gang binary input 3 With 4 Technical its six independent inputs, this binary input can collect 24 V signals and send messages to the KNX, depending on the parameter setting. These can, for example, be messages for switching, dimming (single-level or two-level operation) or for blind/shutter control. Also, it is possible to program certain functions such as dimming value transmitter, light scene extension as well as temperature or brightness transmitter, respectively. Various functions can be assigned to the six inputs. In addition, inputs 1 and 2 can be parameterised with pulse or switching counter functions. Finally, the binary input offers a blocking function to enable or disable certain inputs. data Supply Voltage: 24 V DC (+6 V / -4 V) Power consumption: max. 22 mw Connection: KNX connection block Number 6 Signal voltage 8 V 42 V AC/DC; 0/60 Hz Signal current approx. 4 ma at 24 V AC/DC per input Signal length for pulse Tmin. = 200 ms at a mark-to-space ratio of 1:1 0 -signal 0 1.8 V AC 42 V 1.8 V DC 1 -signal > 8 V AC/DC line length 100 m max. (unshielded) Connection: clamp bar Behaviour at voltage drop only bus voltage no reaction only mains bus and mains no reaction Behaviour at voltage recovery only bus voltage dependent on parameters only mains bus and mains dependent on parameters Protection: IP 20 Operation temperature: C... +4 C Storage temperature: 2 C... +70 C Mounting: on DIN rail 3 x 7. Note: 24 V and 230 V potentials are to be led in separate cables. 109

Description of universal software application: General Free assignment of the switching, dimming, blind/shutter, valuator functions to the inputs. Free assignment of the pulse counter and switching counter functions to inputs 1 and 2. For the pulse counter function parameterised for input 1 (2), input 3 (4) will be reserved for the sync signal and, therefore, cannot be used for any other functions. Signal indication is possible through four yellow status LED s. The status LED will light up when a signal is being applied and cannot be parameterised. Blocking object to enable / disable individual inputs. Delay times upon bus voltage recovery and debouncing time centrally adjustable. Behaviour on bus voltage recovery adjustable. Limit value for telegrams adjustable in general, for all inputs. Switching function Two independent switching objects are available for each input and can be valuated individually. Command upon rising and falling edges separately selectable (ON, OFF, TOGGLE, no response). Independent cyclic sending of the switching objects selectable as a function of the edge or of the object value, respectively. Dimming function Single-level or two-level operation possible. Time between dimming and switching and dimming step width adjustable. Repetition of telegram and sending stop telegram possible. Blind/shutter function Command upon the rising edge (no function, UP, DOWN, TOGGLE) adjustable. Operating concept parameterisable (short long short or long - short). Time between short-time mode and long-time mode adjustable (for short long short only). Louvres adjustment time (for louvers adjustment by one single push button action). Transmitter and light scene extension function Edge (push button as normally-open contact, push button as normally-closed contact, switch) and a certain value can be parameterised. Value changing possible in case of push button mode by pressing push button for a longer time period. For light scene extension with memory function, saving of light scene is also possible without previously recalling it. Temperature / brightness valuator functions Edge (push-button as normally-open contact, push-button as normally-closed contact, switch) and a certain value can be parameterised. Value changing possible in case of push-button mode by pressing push-button for a longer time period. Pulse counter function Pulse counting edge and meter reading interval time can be parameterised. Sync signal edge for counter reset and corresponding switch telegram (including edge evaluation) adjustable. Switching counter function Edge for counting of the input signals and maximum meter reading are adjustable. Step width for meter reading output and command (no telegram, ON, OFF, TOGGLE) upon reaching max. meter reading can be parameterised. 110

Objects for 2114 REG: Number of addresses: 26 Number of assignments: 27 Communication objects: 12 Object Name Function Type Flag Function: Switching (for all inputs) 0 3 1 4 Switching 1 Bit C, W, T, (R) Function: Dimming (for all inputs) 0 3 1 4 Switching 1 Bit C, W, T, (R) 8 11 1 4 Dimming 4 Bit C, T, (R) Function: Blind/shutter control (for all inputs) 0 3 1 4 Short time operation 1 Bit C, T, (R) 8 11 1 4 Long time operation 1 Bit C, T, (R) Function: Dimming value transmitter (for all inputs) 0 3 1 4 Value 1 Byte C, T, (R) Function: Light scene extension (for all inputs) 0 3 1 4 Light scene extension 1 Byte C, T, (R) Function: Temperature value transmitter (for all inputs) 8 11 1 4 Temperature value 2 Byte C, T, (R) Function: value transmitter (for all inputs) 8 11 1 4 Brightness value 2 Byte C, T, (R) Function: Impulse counter (for inputs 1 and 2 only) 2 3 Synch signal counter 1 1 Bit C, W, T, (R) 3 4 Synch signal counter 2 1 Bit C, W, T, (R) 8 1 Meter reading counter 1 2 Byte C, T, (R) 9 2 Meter reading counter 2 2 Byte C, T, (R) Function: Switching counter (for inputs 1 and 2 only) 0 1 Switching counter 1 Bit C, W, T, (R) 1 2 Switching counter 1 Bit C, W, T, (R) 8 1 Switching counter 2 Byte C, T, (R) 9 2 Switching counter 2 Byte C, T, (R) Function: Blocking (for all inputs) 16 19 (*) 1 4 Blocking 1 Bit C, T, (R) Objects marked with (R): Object value can be read out (set R-flag!) Objects marked with (*): If the inputs have been parameterised to "no function", "impulse counter" or "switching counter", the blocking function is not active. 111

Objects for 2118 REG: Number of addresses: 26 Number of assignments: 27 Communication objects: 24 Object Name Function Type Flag Function: Switching (for all inputs) 0 7 1 8 Switching 1 Bit C, W, T, (R) Function: Dimming (for all inputs) 0 7 1 8 Switching 1 Bit C, W, T, (R) 8 1 1 8 Dimming 4 Bit C, T, (R) Function: Blind/shutter control (for all inputs) 0 7 1 8 Short time operation 1 Bit C, T, (R) 8 1 1 8 Long time operation 1 Bit C, T, (R) Function: Dimming value transmitter (for all inputs) 0 7 1 8 Value 1 Byte C, T, (R) Function: Light scene extension (for all inputs) 0 7 1 8 Light scene extension 1 Byte C, T, (R) Function: Temperature value transmitter (for all inputs) 8 1 1 8 Temperature value 2 Byte C, T, (R) Function: value transmitter (for all inputs) 8 1 1 8 Brightness value 2 Byte C, T, (R) Function: Impulse counter (for inputs 1 and 2 only) 2 3 Synch signal counter 1 1 Bit C, W, T, (R) 3 4 Synch signal counter 2 1 Bit C, W, T, (R) 8 1 Meter reading counter 1 2 Byte C, T, (R) 9 2 Meter reading counter 2 2 Byte C, T, (R) Function: Switching counter (for inputs 1 and 2 only) 0 1 Switching counter 1 Bit C, W, T, (R) 1 2 Switching counter 1 Bit C, W, T, (R) 8 1 Switching counter 2 Byte C, T, (R) 9 2 Switching counter 2 Byte C, T, (R) Function: Blocking (for all inputs) 16 23 (*) 1 8 Blocking 1 Bit C, T, (R) Objects marked with (R): Object value can be read out (set R-flag!) Objects marked with (*): If the inputs have been parameterised to "no function", "impulse counter" or "switching counter", the blocking function is not active. 112

Objects for 2126 REG: Number of addresses: 26 Number of assignments: 27 Communication objects: 18 Object Name Function Type Flag Function: Switching (for all inputs) 0 1 6 Switching 1 Bit C, W, T, (R) Function: Dimming (for all inputs) 0 1 6 Switching 1 Bit C, W, T, (R) 8 13 1 6 Dimming 4 Bit C, T, (R) Function: Blind/shutter control (for all inputs) 0 1 6 Short time operation 1 Bit C, T, (R) 8 13 1 6 Long time operation 1 Bit C, T, (R) Function: Dimming value transmitter (for all inputs) 0 1 6 Value 1 Byte C, T, (R) Function: Light scene extension (for all inputs) 0 1 6 Light scene extension 1 Byte C, T, (R) Function: Temperature value transmitter (for all inputs) 8 13 1 6 Temperature value 2 Byte C, T, (R) Function: value transmitter (for all inputs) 8 13 1 6 Brightness value 2 Byte C, T, (R) Function: Impulse counter (for inputs 1 and 2 only) 2 3 Synch signal counter 1 1 Bit C, W, T, (R) 3 4 Synch signal counter 2 1 Bit C, W, T, (R) 8 1 Meter reading counter 1 2 Byte C, T, (R) 9 2 Meter reading counter 2 2 Byte C, T, (R) Function: Switching counter (for inputs 1 and 2 only) 0 1 Switching counter 1 Bit C, W, T, (R) 1 2 Switching counter 1 Bit C, W, T, (R) 8 1 Switching counter 2 Byte C, T, (R) 9 2 Switching counter 2 Byte C, T, (R) Function: Blocking (for all inputs) 16 21 (*) 1 6 Blocking 1 Bit C, T, (R) Objects marked with (R): Object value can be read out (set R-flag!) Objects marked with (*): If the inputs have been parameterised to "no function", "impulse counter" or "switching counter", the blocking function is not active. 113

Notes to software application: Impulse counter The pulse counters can only be parameterised to input 1 or 2. In this case, inputs 3 (for pulse counter 1) or 4 (for pulse counter 2) are the sync signal inputs and cannot be assigned to any other function. Pulse counters 1 and 2 run independently of each other and have a resolution of 16 bit so that counts between 0 and 63 are possible. You can set the R-flag to read out the current count at object 8 or 9. The counting pulse is applied to input 1 or 2. After the interval time specified as parameter has elapsed, the count will be taken over and sent as object value of the 2 byte "count" object (object 8 or 9). Then the 2 byte pulse counter will be internally reset during the next time interval. Only upon the appearance of a new edge at the input, or after the newly started interval time has elapsed, the current count can be read out from the count objects (set R-flag). In addition, the count and the interval time can be reset by a sync signal applied to input 3 or 4, respectively. Moreover, switch telegrams (no telegram, ON, OFF, TOGGLE) can be sent in dependence of the sync signal edge. The output value can be assigned to the edge. The edge assignment for resetting the count can be parameterised independently of the output value. For pulse counting, the mark-to-space time of a signal applied to input 1 or 2 must not fall below 100 ms. PULSE COUNTER 1 / 2 16 bit counter Object 8 / 9 Reset Timer Reset 3 / 4 KNX Edgedependent output Object 2 / 3 Switching counter The switching counters can only be parameterised to input 1 or 2. Switching counters 1 and 2 run independently of each other and have a resolution of 16 bit so that counts between 1 and 63 are possible. You can set the R-flag to read out the current count at object 8 or 9. The counting pulse is applied to input 1 or 2. After the count has reached the parameterised set value, it will be taken over into 2 byte object 8 or 9 and transmitted. Simultannously, it is possible to output a signal value (1 bit object "0" or "1") which can be parameterised. After the transmission, the 16 bit counter will be automatically and internally reset. Only upon the appearance of a new edge at the input, the current count can be read out from the count objects (set R-flag). Moreover, the count will be sent in cycles after a pre-defined number of counting pulses (1 2), which is used to get an automatic update on any display for instance. For switch counting, the mark-to-space time of a signal applied to input 1 or 2 must not fall below 100 ms. SWITCHING COUNTER 1 / 2 Reset 16 bit counter Object 8 / 9 16 bit comparator Object 0 / 1 KNX Maximum count 8 bit counter Reset 8 bit comparator Step width 114

Notes to software application: Bus voltage recovery You can specify for each input what response is to be made upon bus voltage recovery. If a delay time after bus voltage recovery has been parameterised, this time has to be elapsed until the response will be made. Within the delay, any edges or signals applied to the inputs will be ignored. The delay time should be parameterised for all inputs. You can parameterise the limit number of telegrams. In such case, no telegram will be sent within the first 17 s after bus voltage recovery. Please note that any possibly parameterised delay after bus voltage recovery may also be active during this time. Any edge or signal applied to the inputs upon bus voltage recovery will be ignored. Blocking function At the beginning or at the end of the blocking, an independent response can be made to each input. In this case, you can set the parameter to "no response". Only in such case, any dimming or blind/shutter control or value changing events running until the action is completed during an active blocking. In any other cases, the parameterised command will be sent immediately at the start of blocking. Moreover, any edges or signals at the corresponding inputs will not be accepted during an active blocking. Updates on blocking objects (disable or enable) each time cause the corresponding parameterised command to be sent "at start or end of the blocking". During an active blocking, there will be no cyclic sending through the disabled input. If cyclic sending was taking place prior to an activation of the blocking function, no more cyclic sending will be performed at the end of the blocking, provided that "no telegram" has been parameterised. In this case, the cyclic transmission of the object value will only be effected again after an update on the switching object. In any other cases, the object value will be sent in cycles again after the end of blocking. 11