Model DIGITAL MULTIMETER

Similar documents
DIGITAL MULTIMETER INSTRUCTION MANUAL

AMM-1022 Digital Multimeter USER`S MANUAL

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

DIGIT & POINTER MULTIMETER

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

OPERATOR S INSTRUCTION MANUAL

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

MS8216 DIGITAL MULTIMETER OPERATOR S MANUAL

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

DIGITAL MULTIMETER OPERATOR S MANUAL

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

Digital Multimeter with Backlight

INSTRUCTION MANUAL DIGITAL MULTIMETER

DMM8900 SERIES USERS MANUAL

DVM1190 DIGITAL MULTIMETER

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

ProfiScale MULTI Multimeter

MS8223A. CAT.IIi 600 V

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

AC/DC CLAMP METER USER S MANUAL

M-1000D DIGITAL MULTIMETER

Item ref: UK MTM01 DIGITAL MULTITESTER. User Manual

Sales: Technical: Fax:

Model : OPERATING MANUAL Table of Contents (1)

User Manual Digital Multimeter

3B SCIENTIFIC PHYSICS

770E DIGITAL MULTIMETER OPERATOR S MANUAL

HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

Digital Multimeter, Pen Type

KMD-S04 Multímetro de bolsillo

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

Multifunction Digital

Model UT20B: OPERATING MANUAL Table of Contents (1)

Digital Clamp Meter Model: &

4.5 Auto Power Off During use Preparation For Measurement Symbols...3

DIGITAL MULTIMETER OPERATING INSTRUCTIONS MODEL CDM-35. Part No

Table of Contents Title Page

DIGITAL MULTIMETER OPERATION MANUAL

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

DIGITAL CLAMP METER Use s Manual

AUTO RANGING DIGITAL MULTIMETER

User Manual Digital Clamp Multimeter. model no.: MSR-C600

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

AVM360 Analog multimeter OPERATION MANUAL GEBRUIKERSHANDLEIDING MANUEL D UTILISATEUR

Model UT39A/B/C: OPERATING MANUAL

Model UT10A: OPERATING MANUAL Table of Contents (1)

NOTE: Fully read and understand this manual before using this Digital Multimeter.

Digital Multimeter AX-572. Instruction manual

VC835 DIGTAL MULTIMETER Operation Manual

Pocket Size Digital Multimeter Models: and

Dawson DDM190. Digital Multimeter User s Manual

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

User Manual Digital Multimeter. model no.: MSR-U1000

MS2030 CAT III 600 V A V AUTO RS232

1.General instructions Specifications Description...7

Digital Clamp Meter. User Manual

User Manual. All rights reserved. Specifications are subject to change without notice.

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

MS2109A AC/DC Clamp Meter. User Manual. Contents

OPERATOR S INSTRUCTION MANUAL

UT207A/208A/209A Operating Manual. Table of Contents

DM-45 Digital Multimeter

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

DIGITAL MULTIMETER AUTORANGING

Table of Contents GDM-356. Page

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

Internetowy sklep elektroniczny. Kontakt. Tel Tel. Kom Fax

USER'S MANUAL DMR-4300

UT132 Series Manual. UT132 Series. Palm Size Digital Multimeter. Operating Manual -1-

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

Handheld Digital Multimeter PRO-50A

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Analog Technologies VC99. Multimeter FEATURES

DIGITAL MULTIMETER. MODEL CDM-50 Part No OPERATING INSTRUCTIONS

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

INSTRUCTION MANUAL MODEL 21 MULTI-TESTER

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

True RMS Digital Multimeter Model:

DDM350 Pen-Type Digital Multimeter User s Manual

Model UT30B/C/D/F: OPERATING MANUAL CONTENTS

Model UT201/202: OPERATING MANUAL. Table of Contents

User Manual. All rights reserved. Specifications are subject to change without notice.

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

Pen-type DIGITAL MULTITESTER

RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL

MULTIMETRE DIGITAL 3 3/4 AVEC ECHELLE AUTOMATIQUE & EXTINCTION AUTOMATIQUE MANUEL D UTILISATION

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

Transcription:

Model 57070 DIGITAL MULTIMETER INSTRUCTION MANUAL SAFETY INFORMATION To ensure safe operation, and in order to exploit to the full the functionality of the meter, please follow the directions in this section carefully. This multimeter has been designed according to IEC-1010 concerning electronic measuring instruments with an overvoltage category CAT II 1000V, CAT III 600V and pollution 2. Follow all safety and operating instructions to ensure that the meter is used safely and is kept in good operating condition. With proper use and care, the digital meter will give you years of satisfactory service. PRELIMINARY - When using the meter, the user must observe all normal safety rules concerning: Protection against the dangers of electrical current. Protection of the meter against misuse. - When the meter is delivered, check that it has not been damaged in transit. - Test leads must be in good condition. Before using verify that the insulation on test leads are not damaged and/or the lead wires are not exposed. - Full compliance with safety standards can be guaranteed only if used with test leads supplied. If necessary, they must be replaced with the same model or same electric ratings. DURING USE - Before using, you must select the right input jack, function and range. - Never exceed the protection limit values indicated in specifications for each range of measurement. - 1 -

- When the value scale to be measured is unknown beforehand, set - Do not measure voltage if the voltage on the terminals exceeds 1000V above earth ground. - Always be careful when working with voltages above 60V DC or 30V AC rms, keep fingers behind the probe barriers while measuring. - Before rotating the transform switch to change functions and ranges, disconnect test leads from the circuit under test. - Never perform resistance, transistor and diode measurements on live circuits. - Never use the meter under the condition of the explosive air, steam or dirt. - If any faults or abnormalities are observed, the meter cannot be used any more and it has to be checked out. - Never use the meter unless the rear case is in place and fastened fully. - Please do not store or use meter in areas exposed to direct sunlight, high temperature, humidity or condensation. SYMBOLS Important safety information, refer to the operating manual. Double insulation(protection classιι). CAT ΙΙ Overvoltage (Installation) category II, Pollution Degree 2 per IEC1010-1 refers to the level of Impulse Withstand Voltage protection provided. CAT ΙΙΙ Overvoltage (Installation) category III, Pollution Degree 2 per IEC1010-1 refers to the level of Impulse Withstand Voltage protection provided. High voltage warning symbol Conforms to european union directive Earth ground Fuse - 2 - ~ Alternating current Direct current Diode H This indicates that the display data is being held. The battery is not sufficient for proper operation. MAINTENANCE -Please do not attempt to adjust or repair the meter by removing the rear case while voltage is being applied. A technician who fully understands the danger involved should only carry out such actions. - Before opening the battery cover or case of the meter, always disconnect test leads from all tested circuits. - To avoid the misreadings, when the meter displays, you must change the battery. - For continued protection against fire, replace fuse only with the specified voltage and current ratings: F 200mA/250V (quick acting). - Do not use abrasives or solvents on the meter; use a damp cloth and mild detergent only. - Always set the power switch to the OFF position when the meter is not in use. - If the meter is to be stored for a long period of time, the batteries should be removed to prevent damage to the unit. DESCRIPTION - This meter is a portable professional measuring instrument with a handsome LCD for easy reading. - Single operation of the transform switch makes measurement convenient. Overload protection and low battery indication are provided. This meter is ideal for use in the fields, workshop, school, hobby and home applications. - This meter includes the data hold function. - 3 -

NAMES OF COMPONENTS ⑴ LCD Display ⑵ Panel ⑶ H Button: This Button is used to the switch of data hold. ⑷ Transform Switch: This switch is used to select functions and desired ranges. ⑸ 10A Jack: Input terminal for current 0 ~ 10A. ⑹ COM Jack: Common terminal for measurement. ⑺ hfe Jack: This Jack is used for transistor test. ⑻ V/Ω/mA Jack: Input Jack SPECIFICATIONS Accuracy is specified for a period of 1 year after calibration and at 18 to 28 (64 F to 82 F) with relative humidity to 75%. GENERAL SPECIFICATIONS - Max. Voltage Between Terminals And Earth Ground: 1000V DC or 750V AC - Fuse Protection: F 200mA/250V (quick acting). - Display: 15mm LCD - Max. Show Value: 1999 (3-1/2) - Polarity Indication: - indicates negative polarity. - Overrange Indication: Display 1 - Sampling Time: approx. 0.4 second - Low Battery Indication: displayed - 4 - - Power Supply: 1.5V 3 AAA battery. - Operating Temperature: 0 to 40 (32 F to 104 F) - Storage Temperature: -10 to 50 (10 F to 122 F) - Dimension & Weight: 158 74 32 mm, 250g(including battery) ELECTRICAL SPECIFICATIONS Circumstance Temperature: 23 ±5, Relative Humidity: < 75% DC Voltage 200mV 0.1mV ±(0.5% of rdg + 2 digits) 2V 0.001V ±(0.5% of rdg + 3 digits) 20V 0.01V ±(0.8% of rdg + 3 digits) 200V 0.1V 1000V 1V ±(0.8% of rdg + 5 digits) - Input Impedance: 1MΩ - Overload Protection: 200mV range: 250V DC or AC rms, 2V-1000V ranges: 1000V DC or 750VAC rms. - Max. Input Voltage: 1000V DC AC Voltage 200V 0.1V ±(1.2% of rdg + 10 digits) 750V 1V - Input Impedance: 1MΩ - Overload Protection: 750V AC rms or 1000V DC - Frequency Range: 40 to 400Hz - Response: Average, calibrated in rms of sine wave. - Max. Input Voltage: 750V rms AC Diode Range Resolution Function 0.001V Display: read approximate forward voltage of diode - 5 -

- Forward DC Current: approx. 1mA - Reversed DC Voltage: approx.2.8v - Overload Protection: 250V DC or rms AC DC Current 200μA 0.1μA ±(1.0% of rdg + 2 digits) 2mA 0.001mA 20mA 0.01mA ±(1.5% of rdg + 2 digits) 200mA 0.1mA 10A 0.01A ±(3.0% of rdg + 2 digits) - Overload Protection: μa, ma ranges: F 200mA/250V fuse (quick acting), 10A range: unfused. - Max. Input Current: ma Jack: 200mA, 10A Jack: 10A - voltage drop: 200mV Resistance 200Ω 0.1Ω ±(1.0% of rdg + 3 digits) 2kΩ 0.001kΩ 20kΩ 0.01kΩ ±(1.0% of rdg + 2 digits) 200kΩ 2MΩ 0.1kΩ 0.001MΩ - Open Circuit Voltage: 2.8V - Overload Protection: 250V DC or rms AC Transistor hfe Range hfe Function Display: read approximate hfe value (0-1000) of transistor under test (ALL TYPE) - Base Current: approx. 2µA,Vce: approx. 2.8V - 6 - OPERATING INSTRUCTION DATA HOLD If you need data hold when measuring, you can press on H button, it will hold the reading; if you press the button again, data hold will not continue. PREPARATION FOR MEASUREMENT - Turn on the meter. If the battery voltage is less than 3.6V, display will show, the battery should be changed at this time. - The besides the input jack shows that the input voltage or current should be less than specification on the sticker of the meter to protect the inner circuit from damaging. - Select a function and a range for the item to be measured by rotating the transform switch to the selected position. When the value scale to be measured is unknown beforehand, set the range selector at the highest position. - When connecting, first connect to the public testing line, then to the electriferous testing line. When you remove it, you should remove the elecriferous one first. MEASURING DC VOLTAGE You can t test voltage which more than 1000V DC, it s possible to show higher voltage, but it may destroy the inner circuit. Pay attention not to get an electric shock when measuring high voltage. the V jack. - Set the transform switch at the V range position. - Connect test leads across the source or load under measurement. - You can get a reading from LCD display. The polarity of the red test lead connection will be indicated. - 7 -

- When only the figure 1 is displayed, it indicates overrange situation and the higher range has to be selected. - When the value scale to be measured is unknown beforehand, set MEASURING AC VOLTAGE the V jack. - Set the transform switch at the V range position. - Connect test leads across the source or load under measurement. You can t input a voltage which is more than 750V rms AC, it s possible to show higher voltage, but it s may destroy the inner circuit. Pay attention not to get an electric shock when measuring voltage. - When only the figure 1 is displayed, it indicates over range situation and the higher range has to be selected. - When the value scale to be measured is unknown beforehand, set MEASURING DC CURRENT Shut down the power of the tested circuit, then connect the meter with the circuit for measurement. the ma jack for a maximum of 200mA current. For a maximum of 10A, move the red lead to the 10A jack. - Set the transform switch at the A range position. - 8 - - Connect test leads in series with the load under measurement. The polarity of red test lead will be indicated. - When only the figure OL is displayed, it indicates over range situation and the higher range has to be selected. - When the value scale to be measured is unknown beforehand, set - means the socket of INPUT maximum current is 200mA, over current will destroy the fuse. 10A s maximum current is 10A, no fuse protection. MEASURING RESISTANCE When measuring in-circuit resistance, be sure the circuit under test has all power removed and that all capacitors have been discharged fully. the Ω jack. - Set the transform switch at the Ω range position. - Connect test leads across the resistance under measurement. - When only the figure 1 is displayed, it indicates over range situation and the higher range has to be selected. - When the input is not connected, i.e. at open circuit, the figure 1 will be displayed for the over range condition. TESTING DIODE the Ω jack. (The polarity of red lead is + ) - Set the transform switch at the range position. - 9 -

- Connect the red lead to the anode, the black lead to the cathode of the diode under testing. - The meter will show the approximate forward voltage drop of the diode. - If the lead connection is reversed, only figure 1 will be displayed. - When the input is not connected, i.e. at open circuit, the figure 1 will be displayed. TESTING TRANSISTOR - Set the transform switch at the hfe range position. - Identify whether the transistor is NPN or PNP type and insert emitter, base and collector leads into the proper holes of the transistor on the socket for testing. MAINTENANCE BATTERY REPLACEMENT Before attempting to open the battery cover of the meter, be sure that test leads have been disconnected from measurement circuit to avoid electric shock hazard. - Loosen the screw fixing the battery cover and remove it. - Replace the exhausted battery with a new one. - Replace the battery cover. - Replace the battery cover. Before attempting open the battery cover of the meter, be sure that test leads have been disconnected from measurement circuit to avoid electric shock hazard. For protection against fire, replace fuses only with specified ratings: F 200mA/250V (quick acting). TEST LEADS REPLACEMENT Full compliance with safety standards can be guaranteed only if used with the test leads supplied. If necessary, they must be replaced with the same model or same electric ratings. Electric ratings of the test leads: 1000V 10A. You must replace the test leads if the lead is exposed. ACCESSORIES ⑴ Test Leads: Electric Ratings 1000V 10A one piece ⑵ Battery:1.5V, AAA three pieces ⑶ Instruction Manual one piece FUSE REPLACEMENT - Loosen the screw fixing the battery cover and remove it. - Replace the blown fuse with ratings specified. - 10 - - 11 -