Onsite Mobile AC High Voltage Test System

Similar documents
SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

Mobile Power Transformer Test Systm

PCTS Series. Power Capacitor Test System. Applications: Testing Applications: Benefit and Advantage: and IEC

PTTS series. Power Transformer Test System. Scope of Work:

SGM series. AC Resonant Test System. Applications & Advantages

VARIABLE FREQUENCY RESONANT TEST SYSTEM

شركة الوقت للكهرباء والمقاوالت ذ.م.م.

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

High Votage Module AC/DC/Impulse Test System

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

MSR Series. Modular Series Resonant Systems kV; 500kVA...60,000kVA FEATURES BENEFITS APPLICATIONS 1/6

MEDIUM & HIGH VOLTAGE

PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS

700 Series AC Dielectric Test Sets

MSR Series. Modular Series Resonant Systems kV; 500kVA...60,000kVA

AC Resonant Test Systems Tank Type Up to 150 kv

Three-Phase Transformer Test Systems

700 Series AC Dielectric Test Sets

AC Resonant Test Systems Tank Type Up to 500 kv

3. COMBINED TRANSFORMERS Oil-paper insulation

AC Voltage Test System with Transformer

STS Fully automatic. Large graphic display. Primary injection testing capabilities: up to 3000 A, with the optional module BUX 3000

AC Dielectric Test Sets

GENERATOR TESTING APPLICATION GUIDE. reliable. precision.

AC Dielectric Test Systems

HIGH VOLTAGE ENGINEERING(FEEE6402) LECTURER-24

HVI - The World s Source For High Voltage Test Equipment

LV Compensation & Filtering Products

HV AC TESTING OF SUPER-LONG CABLES

ABB Power Products Service

Condition Assessment of High Voltage Insulation in Power System Equipment. R.E. James and Q. Su. The Institution of Engineering and Technology

High voltage shunt capacitor banks HIGH VOLTAGE COMPENSATION AND HARMONIC FILTERING PRODUCTS

4. CAPACITIVE VOLTAGE TRANSFORMERS AND COUPLING CAPACITORS Oil-paper insulation

Specialists in HV and MV test and diagnostics. Testing in Substations

Discipline Electrical Testing Issue Date Certificate Number T-2837 Valid Until Last Amended on - Page 1 of 6 LOCATION 1

Fixed Series Compensation

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

IMPORTANCE OF ACCURATE MEASUREMENTS DURING THE LIFE CYCLE OF UTILITIES

Ritz Instrument Transformers GmbH. Welcome

Industrial Electrician Level 3

Distribution/Substation Transformer

PFCC-1000 series. Powerful Flexibility Durability - Quality. Medium Voltage Metal Enclose 5,15,25,35kV Power Factor Correction & Harmonic Filter

HVA SERIES VLF TEST SETS. Hipot Testers HVA Series for VLF (0.1 Hz) testing of MV and HV cables.

Thyristorised Automatic Power Factor

RESONANT TRANSFORMER

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

Arild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems

Zürcherstrasse 70 -CH 8104 Weiningen Tel Fax P.O. Box 155 Switzerland

CVVOZE Power Laboratories (CVVOZEPowerLab)

FGJTCFWP"KPUVKVWVG"QH"VGEJPQNQI[" FGRCTVOGPV"QH"GNGEVTKECN"GPIKPGGTKPI" VGG"246"JKIJ"XQNVCIG"GPIKPGGTKPI

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation

IN ELECTRICAL ENGINEERING - I C M E T CRAIOVA

Substation Preventive Maintenance

portable affordable CDS Series Cable Fault Locators Thumpers - Surge Generators

PD Diagnostic Applications and TechImp solutions

Capacitor Switching Contactors

Africa Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound

PD Solutions. On-Line PD Measurement Devices

Breakdown indication by visual signal (BUZ in option) breakdown voltage and current are stored on the LCD display

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

Maintenance & Diagnosis Strategies. for. High Voltage Substations

RAP Ripple Control Coupling for parallel injection of RC signals in Medium and High Voltage Networks

7. INSPECTION AND TEST PROCEDURES

Diagnostic testing of cast resin transformers

TECHIMP Technologies & Services for Diagnostics and Monitoring of High Voltage Assets

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

TOA PROFESSIONAL POWER AMP

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

Stabilized Differential Relay SPAD 346. Product Guide

AC Dielectric Test Sets

Power Frequency Withstand Voltage On-site testing of 400 kv GIS

SYSTEMS AND COMPONENTS FOR CABLE TESTING

TECHNICAL SPECIFICATION FOR POWER TRANSFORMER

EI HIGH VOLTAGE INSULATION TESTING POLICY

SPAD 346 C Stabilized differential relay

CPC 100. Multi-functional primary test system for substation commissioning and maintenance

Technical Questionnaire 9.101/6 Transformer Test System. Personal Data. Application. Test of. Delivery scope

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

SHORE TO SHIP FREQUENCY

TECHIMP Power Transformer Monitoring

Distribution transformers Part 2 Ground mounted transformers not closecoupled

KIT 4.0 HIGH VOLTAGE CONSTRUCTION KIT. reliable. precision. HIGH V O L T A G E T E S T S OLUTION S

MONTRANO. Continuous monitoring system for power transformers

Capacitive voltage transformers

CPC 100. Multi-functional Primary Test System for Substation Commissioning and Maintenance

Primary Test Manager (PTM) Testing and management software for primary assets

Capacitive voltage transformers

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

ELECTRICAL POWER ENGINEERING

1% Switchgear and Substations

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

Cast resin transformers HARMONY TM

Condition-based maintenance of power transformers Complete three-phase system Turns Ratio: Recovery Voltage: Winding Resistance:

The Polytransformer. The Multivoltage Substation Power Transformer

EE171. H.H. Sheikh Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

SYSTEMS AND COMPONENTS FOR TRANSFORMER TESTING

Automatic testers. Adapted to testing products With data Base Operator display or PC software bares codes printer

MEDIUM VOLTAGE COMPACT STARTER TYPE KAE

Transcription:

TSGMF(T) series Onsite Mobile AC High Voltage Test System Onsite mobile AC high voltage test systems are used for withstand voltage testing, partial discharge measurement, tan delta measurement to instrument transformers, GIS, GIL, switchgears and etc after they are installed onsite and for purposes of diagnostics in asset management up to 900kV/10A. Onsite mobile AC high voltage test systems can be made by SF6 high voltage test transformer or variable frequency AC resonant test system and complies with requirements according to IEC 60076-3, IEC 60517, IEC62271-203. The test object is connected to the test system using a flexible high-voltage connection via bushing to other connector. The SF6 high voltage test transformer features compact design with bushing output, fix 50Hz or 60Hz, testing frequency is same to the working condition. The high voltage reactor features a modular design. Several reactors can be connected in series or parallel to achieve higher test voltages or power. Test frequency is from 20Hz-300Hz. Both test system can be transported in a container without taking up much space, or it can be set up on a trailer. it is suitable to frequency transportation. Applications: Onsite GIS, GIL testing via bushing testing; Onsite Instrument transformer and switchgear testing; Withstanding voltage testing; Partial discharge measurements; Capacitance and Tan delta measurements; 800kV/4A AC Resonant Test System

Main Features (Variable Frequency Type): Main Features (SF6 Test Transformer Type): The system and its components are designed for onsite testing and frequent transportation and temporary outdoor operation under dry weather conditions. The test system has a very compact and robust design and is easy to install. Several system can be connected in series or parallel to increase voltage or current. Low PD level is lower than 5pC (AC Resonant Test System) IEC-compliant frequency range from 20Hz-300Hz, biggest current is happened in 50Hz, from 20Hz-50Hz can be extend load capacity. It has a very low power consumption The test system has an advanced computer-aided control for full automatic operation, easy data handing / recording and protocol printing. The system and its components are designed for onsite testing and frequent transportation and temporary outdoor operation under any weather conditions. The test system has a very compact and robust design and is easy to install. Low PD level is lower than 2pC Test frequency is 50Hz or 60Hz, the same frequency condition to the working condition. The test system has an advanced computer-aided control for full automatic operation, easy data handing / recording and protocol printing. Easy test, few human power requirement, maintenance free. Safety Feature: Main power circuit breaker with indicating light On/Off push-button control Emergency off mushroom switch High voltage On flashing warning light External interlock provision for test cage or other safety interlock Zero Start interlock Slow and fast-acting resettable overload protection Over current/ over voltage alarm (Over Current Relay) Door switch ARC flash over protection Variable Frequency AC Resonant Test System includes following main components: 400kV/4A SF6 HV Test Transformer System Air core fix inductance reactor Multiple taps Exciter transformer IGBT tunable frequency power source / Linear amplifier tunable frequency power source Switchgear cabinet (Option) Coupling capacitor / HV divider / HV filter SG3005 AC Measuring System

Power Noise Filter (Option) SG2013 Automatic Control System 10ft container for control room 20-50ft Trailer for install the test products Accessories SF6 high voltage test transformer includes following main components: Regulating transformer with shielded insulating transformer Power noise filter Compensating reactor SF6 filled test transformer Coupling capacitor / HV divider / HV filter Control system ACA2000 Pre-stage high voltage switchgear cabinet Subordinate-stage high voltage switchgear cabinet 10ft container for control room 20-50ft Trailer for install the test products Accessories Main Components Feature: Voltage Regulator Feature: Oil Filled Contact Type Voltage Regulator ( Best type for HV testing) Voltage Adjust from 2%-120% Single Phase Input/Output Liner Adjust Voltage Low Impedance to 8% Low Noise to 60dB Easy Maintenance / Repair Wave Form Distortion is less than 1% Heavy Duty DC Motor with Position Indication Double Limit Position Switch Oil Temperature Meter with Temperature Limit Tunable Frequency Power Source Feature (IGBT TYPE): Siemens IGBT Module EPCOS DC Filter Capacitor Voltage Adjust from 1%-110% Wave Form Distortion is less than 2% Heavy Duty Design Frequency from 20-300Hz Available Manual/ Automatic Control Panel Available in the system Quality factor can be 0-0.98 0.1Hz Frequency Adjust Step, 0.01Hz Resolution Partial Discharge is lower than 30pC Tunable Frequency Power Source Feature (Linear Amplifier TYPE): Mitsubishi Power Amplifier Voltage Adjust from 1%-105% Wave Form Distortion is less than 1% Heavy Duty Design Quality factor can be 0.5-0.98 Frequency from 20-300Hz Available Manual/ Automatic Control Panel Available in the system 0.1Hz Frequency Adjust Step, 0.01Hz Resolution Partial Discharge is lower than 2pC Switchgear Cabinet Feature: IP30 Protection Level Chint Circuit Breaker be used in the system Army Level Contactor be used, 5kV DC Insulation between each tap ABB Over Current Relay Voltage and Current Indication In the Each Cabinet and Control Software Manual and Automatic Switch On/OFF and Indication Professional Design and Producing with Perfect Protection Fix Inductance High Voltage Reactor Feature: Air Core Design, it has prefect inductance stability and good voltage/frequency coefficient. Epoxy Glass Cylinder or Bushing Equip 20-300Hz Frequency Range Partial Discharge is lower than 5pC Heavy Duty and low loss

Exciter Transformer Feature: 3 taps suitable for difference load and voltage Insulation cable output Protection Cover Include Impedance is lower than 4% 20-300Hz Frequency Range Partial Discharge is lower than 5pC Heavy Duty SF6 High Voltage Test Transformer Feature: SF6 insulation and bushing output Mechanical lifting Gear Equipped 50Hz/60Hz Power Frequency Input / Output Partial Discharge is lower than 2pC Heavy Duty, it can continuous running for 1 hour, winding temperature rise is lower than 45k Voltage divider/ Standard Capacitor/ HV Filter/ Coupling Capacitor inside the tank 10ft Control Container Feature: 10ft Standard Container (2991 x2438 x 2438 ) Personnel Door and Two Window which has anti-slide function Thermal isolation of floor, walls and celling Electrical Installation (lighting, sockets) Opening for power, control and measuring cable Air Conditioning Table for instruments, chairs

For further information please contact: Samgor Technology Add: No.500 Renmintang Rd. Pudong, Shanghai, 201209, China Tel: 86-21-58999552 58999556 Fax: 86-21-68482953 50323350 E-mail: info@samgor.com Http:// www.samgor.com