LB480A Pulse Profiling USB PowerSensor+ Data Sheet

Similar documents
LB680A Pulse Profiling USB PowerSensor+ Data Sheet

LB480A Pulse Profiling USB PowerSensor+ Data Sheet

LB679A CW and Pulse (Modulation) USB PowerSensor+ Data Sheet

LadyBug Technologies, LLC LB5918L True-RMS Power Sensor

LadyBug Technologies, LLC LB5926A True-RMS Power Sensor

RF and Microwave Power Sensors/Meters Tektronix PSM3000, PSM4000, and PSM5000 Series Data Sheet

Technical Datasheet GT-8550B Series USB Power Sensor 10 MHz to 26.5 GHz

RF and Microwave Power Sensors/Meters Tektronix PSM3000, PSM4000, and PSM5000 Series Data Sheet

Power Measurement Basics

Agilent U2000 Series USB Power Sensors. Data Sheet

Pulse Timing and Latency Measurements Using Wideband Video Detectors

INSTRUCTION SHEET WIDEBAND POWER SENSOR MODEL Copyright 2008 by Bird Electronic Corporation Instruction Book P/N Rev.

Agilent EPM-P Series Single- and Dual-Channel Power Meters Agilent E9320 Family of Peak and Average Power Sensors

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

APPH6040B / APPH20G-B Specification V2.0

Keysight Technologies E8257D PSG Microwave Analog Signal Generator. Data Sheet

Data Sheet. Peak, CW & Average. Power Sensors. Taking performance to a new peak

Model 7000 Series Phase Noise Test System

This section lists the specications for the Agilent 8360 B-Series. generators, Agilent Technologies has made changes to this product

Product Manual for the POWER METER APPLICATION MODEL LB478A/479A/480A/559A/579A/589A

Model 865 RF / Ultra Low Noise Microwave Signal Generator

Applications and Advantages of USB RF Power Sensors Richard R Hawkins, President LadyBug Technologies LLC

Quick Start Guide for the PULSE PROFILING APPLICATION

Advanced Test Equipment Rentals ATEC (2832)

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators Data Sheet

1-Port USB VNA - R60 Extended Specifications

Model 855 RF / Microwave Signal Generator

MA24104A. Inline High Power Sensor. True-RMS, 600 MHz to 4 GHz

DATA SHEET. N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors

Agilent N8262A P-Series Modular Power Meter and Power Sensors. Data Sheet

Product Manual PMA-12 PRECISION POWER METER APPLICATION FOR USE WITH LB5900 SERIES POWER SENSORS

Model 745 Series. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since Model 845-HP Datasheet BNC

Statistical Pulse Measurements using USB Power Sensors

M5090. Extended Specifications EXTEND YOUR REACH TM

Data Sheet. RF Power Meter. Taking performance to a new peak

SIR-4011 MICROWAVE WIDEBAND DSP RECEIVER. WIDE FREQUENCY RANGE: GHz

Agilent N9343C Handheld Spectrum Analyzer (HSA)

Keysight Technologies N9320B RF Spectrum Analyzer

U2020 X-Series USB Peak and Average Power Sensors DATA SHEET

Agilent N9320B RF Spectrum Analyzer

Keysight Technologies E8257D PSG Microwave Analog Signal Generator

MODEL VXIbus UNIVERSAL METER. Page 1 of 5

RF Peak Power Analyzer

Model 865-M Wideband Synthesizer

Improving Amplitude Accuracy with Next-Generation Signal Generators

PN9000 PULSED CARRIER MEASUREMENTS

Model 845-M Low Noise Synthesizer

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

Compact VNA - TR7530. Extended Specifications EXTEND YOUR REACH TM

Cobalt Series 20 GHz EXTEND YOUR REACH TM

Chapter 6 Specifications

N432A Thermistor Power Meter DATA SHEET

Compact VNA - TR1300/1

Analog Arts SG985 SG884 SG834 SG814 Product Specifications [1]

Keysight Technologies 8 Hints for Making Better Measurements Using RF Signal Generators. Application Note

R&S NRP-Zxx Power Sensors Specifications

Amplifier Test Bench Taking performance to a new peak

Key Reference. Agilent Technologies E8257D/67D PSG Signal Generators. Manufacturing Part Number: E Printed in USA July 2007

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators

HP 8901B Modulation Analyzer. HP 11722A Sensor Module. 150 khz MHz. 100 khz MHz. Technical Specifications. Four Instruments In One

Contents. ZT530PCI & PXI Specifications. Arbitrary Waveform Generator. 16-bit, 400 MS/s, 2 Ch

Agilent 8902A Measuring Receiver

4530 Series RF Power Meter

TECHNICAL SPECIFICATION FOR RF (TEST &MEASUREMENT) DEVICE

LMS Series Lab Brick Synthesized Signal Generator

Chapter 5 Specifications

Advanced Test Equipment Rentals ATEC (2832)

Reflectometer Series:

Advanced Test Equipment Rentals ATEC (2832)

PXIe Contents. Required Software CALIBRATION PROCEDURE

Agilent N9342C Handheld Spectrum Analyzer (HSA)

Analog Arts SF900 SF650 SF610 Product Specifications

PM Series Microwave Power Calibration System

Bird Model 7022 Statistical Power Sensor Applications and Benefits

R&S FSWP Phase Noise Analyzer Specifications

Spectrum Analyzer R&S FS300

Frequency range 100 khz to 3 GHz 100 khz to 6 GHz 10 MHz to 18 GHz Reference frequency. 2 ppm in addition 2 ppm/10 C. 0 Hz, 100 Hz to 3 GHz

Keysight 2-Port and 4-Port PNA-X Network Analyzer

Agilent EPM Series Power Meters

DSA700 Series Spectrum Analyzer

Keysight Technologies PNA-X Series Microwave Network Analyzers

Microwave. Accessories for Microwave Scalar and System Analyzers

Power Meter. Measurement Guide. for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master

Understanding the Precision Antenna, Cable, and Power Measurements on the 3550 Radio Test System

Keysight Technologies FieldFox Handheld Analyzers

Model 865-M Wideband Synthesizer

ELECTRONIC COUNTERS, POWER METERS, VOLTMETER. V Hz. W dbm. Microwave Frequency Counter Power Meters Voltmeter

Specification RIGOL. 6 Specification

Chapter 6 Specifications

SC5407A/SC5408A 100 khz to 6 GHz RF Upconverter. Datasheet. Rev SignalCore, Inc.

DSA800. No.1 RIGOL TECHNOLOGIES, INC.

Cost-Effective Traceability for Oscilloscope Calibration. Author: Peter B. Crisp Head of Metrology Fluke Precision Instruments, Norwich, UK

Keysight Technologies FieldFox Handheld Analyzers

High-speed programmable attenuator MAT800

CAA-100A Cable & Antenna Analyzer + Spectrum Analyzer

Agilent U2020 X-Series USB Peak and Average Power Sensors

Agilent N9342C Handheld Spectrum Analyzer (HSA)

Keysight U8480 Series USB Thermocouple Power Sensors DC/10 MHz to 18/33/50/67/120 GHz DATA SHEET

Voltage Sensors URV5-Z

Optimizing Averaging for Better Power Measurements

Transcription:

Key PowerSensor+ Specifications 50 MHz to 8 GHz (functional to 10 GHz) - 60 dbm to +20 dbm 1.95% Total Error* 1.09:1 VSWR (-27 db Return Loss) * Measuring a well matched DUT (-20 dbm @ 1 GHz) No Zero No Cal TM Measurement Capability Time Gated Measurements: Pulse, Peak and Average Power, Overshoot, Crest Factor; Rise and Fall Time, Pulse Width; Pulse Repetition Frequency, Duty Cycle Pulse (Modulation) Power Measurements: Duty Cycle, Measured Pulse Power, Peak Power, Crest Factor Statistical Measurements: CDF, CCDF, PDF Pulse Profiling Panel Test Setup for One Sensor Measurements CW and Average Measurements: Average Power, Duty Cycle-Corrected Pulse Power, Data Logging Description The LB480A is an easy to use, high-performance, pulse-profiling, pulse (modulation), and average power meter and sensor in one. When ordered with option 004, it features a 10 MHz video bandwidth for pulse profiling applications. It measures a -60 dbm signal compared to others that only measure down to -35 dbm, and provides superior in-class performance with high speed measurements and temperature compensated accuracy. Traditional user zero and user reference calibration have been eliminated. Get up and running quickly with the Pulse Profiling power panel. Use the supplied drivers and programming examples for ATE applications. Easily integrate the power sensor(s) into Lab View, C, VB and other environments. Integration and usability are further simplified because calibration and zeroing are not required before use and, you have the flexibility of selecting from a variety of connector types including SMA, N, and 3.5 mm. Contact LadyBug Technologies for TNC connectors. Option 004 provides selectable video bandwidth filters up to 10 MHz for pulse profiling applications. Option 001 provides a <3 Hz bandwidth 0 to 1V analog recorder output signal. Option 0W2 provides a wideband, calibrated analog, negative detector video output signal ~ 1 to 0 Volts (requires option 004). Features Superior in-class price and performance: Measure 10 MHz signals at -60 dbm (25 db lower than others) Fast - 10 to 100 times faster than competitive sensors Compact - 1/10 the volume of competitive sensors Ruggedized USB connector - does not fatigue or break like competitive sensors Trigger on the RF input level No Zero No Cal TM - Fully calibrated over temperature Measuring Opt 0W2 Wideband, Negative Detector, Analog Video Output Signal Applications General purpose scalar measurements General average and pulse RF and microwave power measurements requiring leading edge accuracy: CW & pulsed signals Narrow and wide band signals: CDMA, W-CDMA, QAM, OFDM, GSM, TDMA, QPSK, FSK, AM, FM, etc. Recorders, power monitoring, and ALC loops Research & development, and manufacturing Maintenance, repair, installation, and service 1

LB480A PowerSensor+ Specifications Parameter Frequency Range Dynamic Range LB480A 50 MHz to 8 GHz (functional to 10 GHz) 50 MHz to 6 GHz -60 dbm to +20 dbm 6 GHz to 8 GHz -50 dbm to +20 dbm Accuracy Total Error (RSS) = (Mm² + CF² + L² + N² + T² + Z² ) Note 1 Calibration Factor NIST traceable (Type N male) 50 MHz to 500 MHz 4.0% 500 MHz to 8 GHz 1.7% (SMA & Type N Female) 50 MHz to 500 MHz 4.0% 500 MHz to 8 GHz 2.5% (3.5 mm) 50 MHz to 500 MHz 4.0% 500 MHz to 8 GHz 2.5% Linearity Note 3 (50 MHz to 100 MHz) +15 to +20 dbm 7.00% +10 to +15 dbm 5.00% -60 to +10 dbm 4.00% (100 MHz to 2 GHz) +15 to +20 dbm 7.00% +10 to +15 dbm 5.00% -60 to +10 dbm 3.00% (2 GHz to 8 GHz) +15 to +20 dbm 5.00% +10 to +15 dbm 3.00% -60 to +10 dbm 2.00% Noise 1 second integration (-30 to +20 dbm) 0.22% 50 MHz 100 MHz 0.22% 100 MHz - 6 GHz 0.04% 6 GHz - 8 GHz 0.04% (-50 to -30 dbm) 50 MHz 100 MHz 0.22% 100 MHz - 6 GHz 0.04% 6 GHz - 8 GHz 0.15% (-60 to -50 dbm) 50 MHz 100 MHz 0.44% 100 MHz - 6 GHz 0.15% Zero Offset Note 3 {[(0.35 nw @ 25ºC) + ΔT x (0.025 nw / ºC)] ± 0.005 nw / month} Note 2 ¹ Error term definitions: Mm (Mismatch); CF (Cal Factor); N (Noise); L (Linearity); T (Temperature); Z (Zero Offset). All error terms are converted to percentages for RSS calculation. 2 Use the following formula to determine Zero Offset error (%): Z = (Zero Offset Power / Measured Power)100. 3 Linearity and Zero Offset are measured as a combined specification as LadyBug sensors require no meter zeroing or reference calibration before use. 2

LB480A PowerSensor+ Specifications (continued) Parameter Accuracy (continued) LB480A Match (Type N) 50 MHz 100 MHz 1.5:1 VSWR (14 db Return Loss) 100 MHz to 250 MHz 1.18:1 VSWR (21.7 db Return Loss) 250 MHz to 500 MHz 1.15:1 VSWR (23 db Return Loss) 500 MHz to 8 GHz 1.15:1 VSWR (23 db Return Loss) (super SMA) 50 MHz 100 MHz 1.5:1 VSWR (14 db Return Loss) 100 MHz to 250 MHz 1.18:1 VSWR (21.7 db Return Loss) 250 MHz to 500 MHz 1.09:1 VSWR (27 db Return Loss) 500 MHz to 8 GHz 1.09:1 VSWR (27 db Return Loss) (3.5 mm) 50 MHz 100 MHz 1.5:1 VSWR (14 db Return Loss) 100 MHz to 250 MHz 1.18:1 VSWR (21.7 db Return Loss) 250 MHz to 500 MHz 1.09:1 VSWR (27 db Return Loss) 500 MHz to 8 GHz 1.09:1 VSWR (27 db Return Loss) Temperature (ºC) 40-50 1.00% (plus 1%, 0 dbm to 10 dbm; plus 3%, 10 dbm to 20 dbm) 30-40 0.75% (plus 1%, 0 dbm to 10 dbm; plus 3%, 10 dbm to 20 dbm) 20-30 0.00% 10-20 0.75% (plus 1%, 0 dbm to 10 dbm; plus 3%, 10 dbm to 20 dbm) 0-10 1.00% (plus 1%, 0 dbm to 10 dbm; plus 3%, 10 dbm to 20 dbm) Maximum Average Power Damage Level Maximum Pulse Power Damage Level Maximum Peak-to-Average Ratio +20 dbm (100 mw) +23 dbm (200 mw) +20 dbm (100 mw) +23 dbm (200 mw) 50 MHz to 6 GHz 80 db 6 GHz to 8 GHz 70 db Internal Video Bandwidth Power Meter Measurements 10 MHz Pulse Profiling (standard) 100 khz Pulse Profiling (option 004) 100 khz, 200 khz, 300 khz, 500 khz, 1 MHz, 2 MHz, 3 MHz, 5 MHz, 10 MHz 10 % to 90% Rise Time (option 004) 54 ns (-70 to -20 dbm pulse measured @ 4 GHz) 10 % to 90% Fall Time (option 004) 44 ns (-70 to -20 dbm pulse measured @ 4 GHz) Time Base Effective Sample Rate +/- 50 ppm 48 MS/second Measurements Pulse Profiling Power Measurements (Time Gating to Analyze Pulse Parameters) Pulse (Modulation) Power Measurements Statistical Measurements Average Power Measurements Display & Data Processing Capability Markers Gating Scaling Trace 2000/second Pulse Power, Peak Power, Average Power, Droop, Rise Time, Fall Time, Overshoot, Pulse Width, Pulse Repetition Frequency, Duty Cycle, Crest Factor (Peak-to-Average Ratio) Duty Cycle, Measured Pulse Power, Peak Power, Crest Factor (Peak-to-Average Ratio) CDF, CCDF, PDF Average Power, Duty Cycle-Corrected Pulse Power, Data Logging Multiple sensors, displays, and traces 5 pairs 5 pairs Linear, db Averaging, offset, scaling, statistics 3

LB480A PowerSensor+ Specifications (continued) Parameter LB480A Trigger Standard Resolution 20.8 ns Delay 10 ms Hold off 250 ms Modes Single, Continuous Source Internal, External Trigger Rate 1 Hz to 750 KHz Trigger Off Time 1 us minimum Internal Trigger Level Mode Manual, Auto Signal Level Trigger Range 50 MHz to 6 GHz -45 dbm to +20 dbm 6 GHz to 8 GHz -40 dbm to + 20 dbm Input TTL compatible, rising or falling edge VIH, minimum high-level input 2.0 V at +/- 10 ua VIL, maximum low-level input 0.8 V at +/- 10 ua SMB male (shared with recorder output) Absolute maximum levels 5.5 V maximum, -0.5 V minimum Output (Not available with opt 0W2) TTL compatible, rising or falling edge VOH, minimum high-level output 4.6 V at 1 ma VOL, maximum low-level output 0.8 V at -1 ma SMB male Absolute maximum levels 5.5 V maximum, -0.5 V minimum Recorder Out Option 001 (not available with opt 0W2) Range Operating 0 to 1 V typical Maximum Output 5 V, if in trigger mode (option 003) Output Impedance / Bandwidth 1 K ohm typical / 3 Hz typical Sensitivity Scale Linear or db, factory default to Linear Full Scale Value User settable, factory default to Linear SMB male (shared with trigger input) Wideband Video Detector Out Option 0W2 (Requires opt 004, not available with opt 001) Range Voltage Output 1 to 0 V typical (Negative Power Detecting) Real-time Detected RF Power -45 to + 20 dbm typical Output impedance / Bandwidth 50 ohm typical / 10 MHz typical Sensitivity 0.15 db/v typical SMB male (replaces Trigger Output) Recommended Calibration Cycle 1 year Environment, operating Temperature 0 ºC to 55 ºC Humidity 15% - 95% non-condensing Altitude 10,000 feet (3,000 meters) Environment, storage Temperature -25 ºC to 85 ºC Humidity 15% to 95% non-condensing Altitude 50,000 feet (15,000 meters) Physical Weight 2.9 oz (82 g), plus connector weight Size 1.6 (40 mm) diameter by 2.3 (71 mm) long plus connector length 4

5

Revisions to data sheet by date: 06/25/10: 1. Add opt 0W2. 2. Add revision page. 06/01/2012 1. Add 3.5 mm connectors 2. Add temperature sensitivity graph 01/06/2013: 1. add 50 MHz specs 6