~W~~~ Laboratory Accreditation Program

Similar documents
A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CHAPTER 6 EMI EMC MEASUREMENTS AND STANDARDS FOR TRACKED VEHICLES (MIL APPLICATION)

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Astra Microwave Products Ltd. Environmental, EMI/EMC Test Facilities & Laser Welding

MIL Standard 461 G. final release December 11 th, EMC PARTNER - Largest range of impulse test equipment up to 100kV and 100kA

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Laboratory Accreditation Programmes

CERTIFICATE OF ACCREDITATION

National Voluntary Laboratory Accreditation Program

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec

An Introduction to EMC Testing (what can be done with scopes) Vincent Lascoste EMC Product Manager - RSF

Downloaded from 1. THE FOLLOWING PAGES OF MIL-STD-462D HAVE BEEN REVISED AND SUPERSEDE THE PAGES LISTED:

Partners for HV and EMC Solutions MIL-STD-461 G. Partners for HV and EMC Solutions

Electromagnetic Interference Mitigation

MS14. Military Qualified 1x4 GPS Splitter. Description TECHNICAL PRODUCT DATA. Features. Designed & Manufactured to Military Specifications

One-day Conference 18 March Power Supply, EMC and Signalling, in Railway Systems

ANSI-ASQ National Accreditation Board/ACLASS

National Voluntary Laboratory Accreditation Program

Surge Generator for MIL-STD 1275

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

EMC Test Report. Report Number: M030826

Electromagnetic and Radio Frequency Interference (EMI/RFI) Considerations For Nuclear Power Plant Upgrades

DEPARTMENT OF DEFENSE INTERFACE STANDARD

FISCHER CUSTOM COMMUNICATIONS, INC.

2620 Modular Measurement and Control System

Advanced Test Equipment Rentals ATEC (2832)

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

esa Space Station Electromagnetic Emission and Susceptibility Requirements International Space Station Revision C May 31, 1996 SSP Revision C

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

High precision measurement system for current and voltage IHC-A/B-RM01/03

MID energy meter B21 Single-phase energy meter, 65 A

DEPARTMENT OF DEFENSE INTERFACE STANDARD

HEC-30/35LTA-33TDAA Rev A

Understanding Design, Installation, and Testing Methods That Promote Substation IED Resiliency for High-Altitude Electromagnetic Pulse Events

System description 4. SERVICES ONSITE INSTALLATION AND TRAINING SYSTEM ACCEPTANCE MAINTENANCE... 7

HEC-35LTA-XXTSAA Rev A

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

HEC-70LCN-350TDAF Rev B

Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient. 3 Electromagnetic Interference

SEMASPEC Provisional Test Method for Evaluating the Electromagnetic Susceptibility of Thermal Mass Flow Controllers

Electromagnetic compatibility (EMC) Part 4-2: Testing and measurement techniques Electrostatic discharge immunity test

Harmonizing the ANSI-C12.1(2008) EMC Tests. Harmonizing the ANSI-C12.1(2008) EMC Tests

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Technical Criteria for the Accreditation Of Electromagnetic Compatibility (EMC) And Radio Testing Laboratories

HEC-45LTN-45PFAS Rev A

SL-E BOOK 3 VOLUME 1

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Rotary Servo Actuator

PRODUCT BRIEF Copper to Fiber Ethernet Media Converter 10/100/1000BASE-T to 1000BASE-SX M38999, 28VDC

CS114 + CS115 + CS116

DEPARTMENT OF DEFENSE INTERFACE STANDARD

Immunity Testing for the CE Mark

Electromagnetic compatibility Guidance and manufacturer s declaration DIN EN :2007 (IEC :2007)

CE Testing Results and Explanation

EMC Test report for LED Panel Light Models , , , , ,

Combination Wave Test System

z8801 Local Oscillator PXI

Bilaga 2 / Appendix 2

50W Constant Current (700mA) Dimming LED Driver

FS24W Series LED Driver Input: V High Power Factor High efficiency Subminiaturization IP66 SPECIFICATIONS

Power Quality Issues from an EMC Point of View

EMC standards. Presented by: Karim Loukil & Kaïs Siala

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. CKC LABORATORIES, INC rd Drive S.E., Suite A Bothell, WA Steve Behm Phone:

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCE EMITTED FROM TELECOMMUNICATIONS EQUIPMENT

Table of Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient (EFT) 3 Electromagnetic Interference

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

EMC aspects associated to 5G networks

Power Sensors Ltd. PQube 3 AC Analyzer IEC Class 0,2 S Accuracy Compliance Report

BIODEX MULTI- JOINT SYSTEM

EMC Requirement for LED Lighting and Accessories & EMC Facilities in SIRIM

RadICS System EQ Testing: Results and Lessons Learned

EN v1.2.1 ( ) TEST REPORT FOR n 1X2 PCIe MINICARD TRANSCEIVER MODEL NUMBER: AR5B91 REPORT NUMBER: 08U

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

EMC Pulse Measurements

TEST REPORT FROM RFI GLOBAL SERVICES LTD

E M C T E S T Y O U R SOURCE FOR TOP Q U A L I T Y TEST EQUIPMENT & E M C. w w w. h v t e c h n o l o g i e s. c o m

z475 Remote DC Power Supply Preliminary

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

EN v1.2.1 ( ) TEST REPORT FOR b/g PCIExpress Minicard MODEL NUMBER: AR5BXB63 REPORT NUMBER: 06U

75W Constant Current (700mA) LED Driver

Series Rev 1.2 Dec. 2015

ELEC 425 Interference Control in Electronics Lecture 0 Introduction to the Course & Syllabus

OPSJ1900 J1900 Open Pluggable Specification Products

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Schlöder GmbH - EMC Test and Measurement Systems Model #

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. MiCOM LABS 1, Boulder Court Pleasanton, California USA Gordon Hurst Phone: (+1)

Reverberation Chambers Design and Construction Considerations for Aerospace and Military Test Requirements

HEC-100RTA-48QSCA Rev A1.0

Mil Std 461E CS-115 CS-115 MIL STD 461E CS-115 CS-116 RS-105

Smart Termination TECHNICAL SPECIFICATIONS CURRENT VOLTAGE INSTRUMENTRANSFORMER

DRAFT REGULATORY GUIDE DG-1029

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan

Transcription:

~ ~.en) National Voluntary ~W~~~ Laboratory Accreditation Program SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Dayton T. Brown, Inc. 1195 Church Street Bohemia, NY 11716 Ms. Mary Alice Der Aris Phone: 631-244-6315 Fax: 631-589-4046 Email: mderaris@dtbtest.com http://www.dtbtest.com ELECTROMAGNETIC COMPATIBILITY & TELECOMMUNICATIONS Immunity RTCA/D0-160C (1989) RTCA/D0-1600 (1997) RTCA/D0-160F (2007) RTCA/D0-160E (2004) RTCA/D0-1600 (2010) RTCA/D0-160C (1989) RTCA/D0-1600 (1997) RTCAID0-160F (2007) Environmental Conditions and Test Procedures for Airborne Equipment - Section 15: Magnetic Effect Environmental Conditions and Test Procedures for Airborne Equipment- Section 15: Magnetic Effect Environmental Conditions and Test Procedures for Airborne Equipment- Section 15: Magnetic Effect Environmental Conditions and Test Procedures for Airborne Equipment- Section 15: Magnetic Effects Environmental Conditions and Test Procedures for Airborne Equipment- Section 15: Magnetic Effects Page 1 of8

[t!]w~&~ National Voluntary Laboratory Accreditation Program RTCA/D0-160E (2004) RTCA/D0-160G (2010) RTCA/D0-160G (2010) RTCA/D0-160C (1989) RTCA/D0-160D (1997) RTCA/D0-160F (2007) RTCA/D0-160E (2004) RTCAID0-160G (2010) Environmental Conditions and Test Procedures for Airborne Equipment- Section 20.4: RF Susceptibility, Conducted Environmental Conditions and Test Procedures for Airborne Equipment - Section 22: Environmental Conditions and Test Procedures for Airborne Equipment - Section 22: Environmental Conditions and Test Procedures for Airborne Equipment - Section 22: Environmental Conditions and Test Procedures for Airborne Equipment- Section 22: Environmental Conditions and Test Procedures for Airborne Equipment - Section 22: MIL-STD MIL-STD-1275A MIL-STD-1275A Notice 1 MIL-STD-1275A Notice 2 MIL-STD-1275B Notice 1 MIL-STD-1275D MIL-STD-1399 Section 070 MIL-STD 1399 Section 300A MIL-STD-461A MIL-STD-462: 1967 with Notices 1, 2, 3, 4, 5, 6 MIL-STD-704,(1959) Characteristics of28 Volts DC Electrical Systems in Military Vehicles Characteristics of28 Volt DC Electrical Systems in Military Vehicles Characteristics of28 Volt DC Electrical Systems in Military Vehicles Characteristics of28 Volt DC Electrical Systems in Military Vehicles Characteristics of 28 Volt DC Electrical Systems in Military Vehicles Interface standard for shipboard systems, Section 070- Part 1- DC Magnetic Field Environment Interface standard for Shipboard Systems: Electric Power, Alternating Current Electromagnetic Interference Characteristics Requirements for Equipment (CE03, CE04, RE02, RS03) Military Standard, Electromagnetic Interference Characteristics, Measurement of. Notice 1:1968; Notice 2:1970; Notice 3: 1971; Notice 4:1980; Notice 5:1986; Notice 6:1987 (CE03, CE04, RE02, RS03) Page 2 of8

~W~&:@' National Voluntary Laboratory Accreditation Program MIL-STD-704, Revision A (August 9, 1966) MIL-STD-704, Revision B (November 17,1975) MIL-STD-704, Revision C (December 30, 1977) MIL-STD-704, Revision D (September 30, 1980) MIL-STD-704, Revision E (May 1, 1992) MIL-STD-704, Revision F (March 12, 2004) Aircraft, Electric Power Characteristics MIL-STD: Conducted Emissions MIL-STD-461G, CE101 MIL-STD-461E, CE101 MIL-STD-461F, CE101 MIL-STD-461G, CE102 MIL-STD-461E, CE102 MIL-STD-461F, CE102 MIL-STD-461G, CE106 MIL-STD-461E, CE106 MIL-STD-461F, CE106 MIL-STD-462, CE01 MIL-STD-462, CE02 MIL-STD-462, CE03 MIL-STD-462C, CE03 MIL-STD-462, CE04 MIL-STD-462, CE06 Conducted Emissions, Power Leads, 30 Hz to 10 khz Conducted Emissions, Power Leads, 30 Hz to 10 khz Conducted Emissions, Power Leads, 30Hz to 10kHz Conducted Emissions, Power Leads, 10 khz to 10 MHz Conducted Emissions, Power Leads, 10 khz to 10 MHz Conducted Emissions, Power Leads, 10 khz to 10 MHz Conducted Emissions, Antenna Terminal, 10kHz to 40 GHz Conducted Emissions, Antenna Terminal, 10kHz to 40 GHz Conducted Emissions, Antenna Terminal, 10 khz to 40 GHz Conducted Emissions, Power and Interconnecting Leads, Low Frequency (up to 15kHz) Conducted Emission, 30 Hz to 20 khz, Control and Signal Leads Conducted Emissions, Power and Interconnecting Leads, 0.015 to 50 MHz Conducted Emissions, Power and Interconnecting Leads, 0.015 to 50 MHz Conducted Emissions, Control and Signal Leads, 30 Hz to 20 khz Conducted Emissions, Antenna Terminals 10 khz to 26 GHz Page 3 of8

~W~ ~ National Voluntary Laboratory Accreditation Program MIL-STD-462C, CE06 MIL-STD-462, CE07 MIL-STD-462C, CE07 MIL-STD-462D, CE101 MIL-STD-462D, CE102 MIL-STD-462D, CE106 Conducted Emissions, Antenna Terminals 10 khz to 26 GHz Conducted Emissions, Power Leads, Spikes, Time Domain Conducted Emissions, Power Leads, Spikes, Time Domain Conducted Emissions, Power Leads, 30Hz to 10kHz Conducted Emissions, Power Leads, 10 khz to 10 MHz Conducted Emissions, Antenna Terminal, 10kHz to 40 GHz MIL-STD: Conducted Susceptibility MIL-STD-461G, CS101 MIL-STD-461E, CS101 MIL-STD-461F, CS101 MIL-STD-461G, CS103 MIL-STD-461E, CS103 MIL-STD-461F, CS103 MIL-STD-461G, CS104 MIL-STD-461E, CS104 MIL-STD-461F, CS104 MIL-STD-461G, CS105 MIL-STD-461E, CS105 MIL-STD-461F, CS105 MIL-STD-461F, CS106 MIL-STD-461G, CS109 MIL-STD-461E, CS109 MIL-STD-461F, CS109 MIL-STD-461G, CS114 Conducted Susceptibility, Power Leads, 30Hz to 150kHz Conducted Susceptibility, Power Leads, 30 Hz to 150 khz Conducted Susceptibility, Power Leads, 30Hz to 150kHz Conducted Susceptibility, Antenna Port, Intermodulation, 15 khz to 10 GHz Conducted Susceptibility, Antenna Port, Intermodulation, 15kHz to 10 GHz Conducted Susceptibility, Antenna Port, Intermodulation, 15 khz to 10 GHz Conducted Susceptibility, Antenna Port, Rejection of Undesired Signals, 30Hz to 20 GHz Conducted Susceptibility, Antenna Port, Rejection of Undesired Signals, 30Hz to 20 GHz Conducted Susceptibility, Antenna Port, Rejection of Undesired Signals, 30Hz to 20 GHz Conducted Susceptibility, Antenna Port, Cross-Modulation, 30Hz to 20 GHz Conducted Susceptibility, Antenna Port, Cross-Modulation, 30Hz to 20 GHz Conducted Susceptibility, Antenna Port, Cross-Modulation, 30Hz to 20 GHz Conducted Susceptibility, Transients, Power Leads Conducted Susceptibility, Structure Current, 60Hz to 100kHz Conducted Susceptibility, Structure Current, 60Hz to 100kHz Conducted Susceptibility, Structure Current, 60Hz to 100kHz Conducted Susceptibility, Bulk Cable Injection, 10kHz to 200 MHz Page 4 of8

~W~ JW National Voluntary Laboratory Accreditation Program MIL-STD-461E, CS114 MIL-STD-461F, CS114 MIL-STD-461G, CS115 MIL-STD-461E, CS115 MIL-STD-461F, CS115 MIL-STD-461G, CS116 MIL-STD-461E, CS116 MIL-STD-461F, CS116 MIL-STD-461G, CS117 MIL-STD-461G, CS118 MIL-STD-462, CS01 MIL-STD-462C, CSO 1 MIL-STD-462, CS02 MIL-STD-462C, CS02 MIL-STD-462 Method CS03/CS04/ CS05 MIL-STD-462C, CS03 MIL-STD-462C, CS04 MIL-STD-462C, CS05 MIL-STD-462, CS06 MIL-STD-462C, CS06 MIL-STD-462, CS07 MIL-STD-462, CS09 MIL-STD-462C, CS09 Conducted Susceptibility, Bulk Cable Injection, 10kHz to 200 MHz Conducted Susceptibility, Bulk Cable Injection, 10kHz to 200 MHz Conducted Susceptibility, Bulk Cable Injection, Impulse Excitation Conducted Susceptibility, Bulk Cable Injection, Impulse Excitation Conducted Susceptibility, Bulk Cable Injection, Impulse Excitation Conducted Susceptibility, Damped Sinusoidal Transients, Cables and Power Leads, 10 khz to 100 MHz Conducted Susceptibility, Damped Sinusoidal Transients, Cables and Power Leads, 10 khz to 100 MHz Conducted Susceptibility, Damped Sinusoidal Transients, Cables and Power Leads, io khz to 100 MHz Conducted Susceptibility, Lightning Induced Transients, Cables and Power Leads Personnel Borne Electrostatic Discharge (ESD) Conducted Susceptibility, Power Leads, 30Hz to 50 khz Conducted Susceptibility, Power Leads, 30Hz to 50 khz Conducted Susceptibility, Power Leads, 0.05 to 400 MHz Conducted Susceptibility, Power and Interconnecting Control Leads, 0.05 to 400 MHz Conducted Susceptibility, lntermodulation, Cross-modulation Intermodulation, 15 khz to 10 GHz Rejection of Undesired Signals, 30Hz to 20 GHz Cross-modulation, 30 Hz to 20 GHz Conducted Susceptibility, Spikes, Power Leads Conducted Susceptibility, Spikes, Power Leads Conducted Susceptibility, Squelch Circuits Conducted Susceptibility, Structure (Common Mode) Current, 60 Hz to 100 khz Conducted Susceptibility, Structure (Common Mode) Current, 60Hz to 100kHz Page 5 of8

lf!jw~ :@ National Voluntary Laboratory Accreditation Program MIL-STD-462, CS10 MIL-STD-462C, CS10 MIL-STD-462, CS11 MIL-STD-462C, CSll MIL-STD-462, CS12 MIL-STD-462, CSl3 MIL-STD-462C, CS14 MIL-STD-4620, CS101 MIL-STD-462D, CS103 MIL-STD-4620, CS104 MIL-STD-4620, CS105 MIL-STD-462D, CS109 MIL-STD-4620, CS114 MIL-STD-462D, CS115 MIL-STD-462D, CS116 Conducted Susceptibility, Damped Sinusoidal Transients, Pins and Terminals, 10kHz to 100MHz Conducted Susceptibility, Damped Sinusoidal Transients, Pins and Terminals, 10kHz to 100MHz Conducted Susceptibility, Damped, Sinusoidal Transients, Cable, 10kHz to 100 MHz Conducted Susceptibility, Damped, Sinusoidal Transients, Cable, 10kHz to 100 MHz Conducted Susceptibility, Common-mode cable current pulse, interconnecting power Conducted Susceptibility, Single Wire coupled pulse MIL-STD-462 Version C Method CS14 Conducted Susceptibility, Power Leads, 30Hz to 50 khz Conducted Susceptibility, Antenna Port, Intermodulation, 15kHz to 10 GHz Conducted Susceptibility, Antenna Port, Rejection of Undesired Signals, 30Hz to 20 GHz Conducted Susceptibility, Antenna Port, Cross-Modulation, 30Hz to 20 GHz Conducted Susceptibility, Structure Current, 60HZ to 100kHz Conducted Susceptibility, Bulk Cable Injection, 10kHz to 400 MHZ Conducted Susceptibility, Bulk Cable Injection, Impulse Excitation Conducted Susceptibility, Damped Sinusoidal Transients, Cables and Power Leads, 10 khz to 100 MHz MIL-STD: Radiated Emissions MIL-STD-461G, RE101 MIL-STD-461E, RE101 MIL-STD-461F,RE101 MIL-STD-461G, RE102 MIL-STD-461E,RE102 MIL-STD-461F, RE102 MIL-STD-461G, RE103 Radiated Emissions, Magnetic Field, 30Hz to 100kHz Radiated Emissions, Magnetic Field, 30Hz to 100kHz Radiated Emissions, Magnetic Field, 30Hz to 100kHz Radiated Emissions, Electric Field, 10kHz to 18 GHz Radiated Emissions, Electric Field, 10 khz to 18 GHz Radiated Emissions, Electric Field, 10 khz to 18 GHz Radiated Emissions, Antenna Spurious and Harmonic Outputs, 10kHz to 40 GHz Page 6 of8

~'\ ~ :@' National Voluntary Laboratory Accreditation Program MIL-STD-461E, RE103 MIL-STD-461F,RE103 MIL-STD-462, RE01 MIL-STD-462C, REO 1 MIL-STD-462, RE02 MIL-STD-462C, RE02 MIL-STD-462,RE03 MIL-STD-462C, RE03 MIL-STD-4620, RE101 MIL-STD-4620, RE102 MIL-STD-4620,RE103 Radiated Emissions, Antenna Spurious and Harmonic Outputs, 10kHz to 40 GHz Radiated Emissions, Antenna Spurious and Harmonic Outputs, 10 khz to 40 GHz Radiated Emissions, Magnetic Field, 0.03 to 50 khz Radiated Emissions, Magnetic Field, 0.03 to 50 khz Radiated Emissions, Electric Field, 10 khz to 18 GHz Radiated Emissions, Electric Field, 14 khz to 10 GHz Radiated Emissions, Spurious and Harmonics, Radiated Technique Radiated Emissions, Spurious and Harmonics, Radiated Technique Radiated Emissions, Magnetic Field, 30Hz to 100kHz Radiated Emissions, Electric Field, 10 khz to 18 GHz Radiated Emissions, Antenna Spurious and Harmonic Outputs, 10 khz to 40 GHz MIL-STD: Radiated Susceptibility MIL-STD-461G, RS101 MIL-STD-461E, RS101 MIL-STD-461F, RS101 MIL-STD-461G, RS103 MIL-STD-461E, RS103 MIL-STD-461F, RS103 MIL-STD-461G, RS105 MIL-STD-461E, RS105 MIL-STD-461F, RS105 MIL-STD-462, RSOl MIL-STD-462C, RSO 1 MIL-STD-462, RS02 Radiated Susceptibility, Magnetic Field, 30Hz to 100kHz Radiated Susceptibility, Magnetic Field, 30Hz to 100kHz Radiated Susceptibility, Magnetic Field, 30Hz to 100kHz Radiated Susceptibility, Electric Field, 2 MHz to 40 GHz Radiated Susceptibility, Electric Field, 2 MHz to 40 GHz Radiated Susceptibility, Electric Field, 2 MHz to 40 GHz Radiated Susceptibility, Transient Electromagnetic Field Radiated Susceptibility, Transient Electromagnetic Field Radiated Susceptibility, Transient Electromagnetic Field Radiated Susceptibility, Magnetic Field, 0.03 to 50 khz Radiated Susceptibility, Magnetic Field, 0.03 to 50 khz Radiated Susceptibility, Magnetic and Electric Fields, Spikes and Power Frequencies Page 7 of8

~W~&~ National Voluntary Laboratory Accreditation Program MIL-STD-462C, RS02 MIL-STD-462, RS03 MIL-STD-462, RS03 MIL-STD-462C, RS03 MIL-STD-462 RS06 MIL-STD-4620, RS101 MlL-STD-4620, RS103 MIL-STD-4620, RS105 Radiated Susceptibility, Magnetic and Electric Fields, Spikes and Power Frequencies Radiated Susceptibility, Electric Field, 14kHz to 40 GHz (Consult laboratory for field strengths available) Radiated Susceptibility, Electric Field, 14kHz to 40 GHz, employing RADHAZ procedures for high level testing (Consult laboratory for field strengths available) Radiated Susceptibility, Electric Field, 14kHz to 40 GHz Radiated Susceptibility, Electromagnetic Field, Switching Pulses (Chattering Relay) Radiated Susceptibility, Magnetic Field, 30Hz to 100kHz Radiated Susceptibility, Electric Field, 10kHz to 40 GHz Radiated Susceptibility, Transient Electromagnetic Field Page 8 ofs