TE90 90W Single Output External Power Test & Measurement/Industrial Series

Similar documents
TE60 60W Single Output External Power Test & Measurement/Industrial Series

TE60 60W Single Output External Power Test & Measurement/Industrial Series

TE W Single Output External Power Test & Measurement/Industrial Series

LPS. TE20 15W-20W Single Output External Power Test & Measurement/Industrial Series. Features

TE40 40W Single Output External Power Test & Measurement/Industrial Series

FEATURES AND BENEFITS. Compact size: 6.5 x 2.8 x 1.5

TB65 65W Single Output Test and Measurement/Industrial Series

MB120S 120W Single Output Medical Series

LB115S 115W Single Output

Model Selection Model Output Current Total OVP Number Class Volts (Convection Cooled) Efficiency 1 Ripple &Noise 2 Regulation Threshold

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

Doc. EA Model Number:

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

Product Specification sheet

CLP0112 Open Frame Power Supply Vac input; 12Vdc output; 150W Output Power

C B. Models. Models 2MOPP

LFWLP W 12V 15.00A 25.00A 92%

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS18 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

Features. Regulated Converters. RACM Watt Enclosed Case Style Single Output. RACM150- S/ _ Fan Option (1) Single. AC/DC Converter.

HEC-45LTN-45PFAS Rev A

These medical power supplies are ideal for, monitoring, home health equipment as well as surgical devices.

Features. Regulated Converter RACM Watt Enclosed & Open Frame Case Style Single Output RACM65- S / - AC/DC Converter.

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

General. Environmental. EMC & Safety

HEC-30/35LTA-33TDAA Rev A

For more information, please visit the product page. output. output current max (A)

Sirius 250/350 Watts, Single / Multi output AC-DC, modular power solution

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

Note1: Max Cap Load is tested at minimum input and full resistive load. Connections (3) Case Style (1)

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

Features. Regulated Converters. RACM40 40 Watt Enclosed & Open Frame Case Style Single Output RACM40- S / - AC/DC Converter.

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

HEC-70LCN-350TDAF Rev B

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

HEC-35LTA-XXTSAA Rev A

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

MVAB120 Series 120W 2" x 4" AC-DC Power Supply Converter

Electrical Specifications. Input Current 115 VAC: 1.2 A max. 230 VAC: 0.65 A max.

VOF XX - XXX - X

CLP0224 Open Frame Power Supply Vac input; 24Vdc output; 200W Output Power

70 Watt Switching Medical Grade Switching Power Supply with Active PFC CONTENTS 1. GENERAL CIRCUIT TOPOLOGY...2

HEC-150RTN-48QSCA. A. Features. B. Description. C. Models. D. Electronic Specifications - Input Specifications

150 Watt Industrial (WLT)

Features. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

Electrical Specifications

General. Efficiency Isolation. Dimensions Net Weight. Safety & EMC

Features. Regulated Converters. RAC05-K 5 Watt 1 x 1 Single Output RAC05- SK. AC/DC Converter

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

CB Scheme UL508 UL ATEX II3G

HEC-100RTA-48QSCA Rev A1.0

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

The MBC550 range is ideally suited to a wide variety of medical applications, and also where airflow is limited or not available.

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

Metal Case Power Supplies

IEC/EN/UL60950 & CE certified, EN55032 Class B

HEC-40LTN-XXPSCA Rev A

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

IP67 DESCRIPTION KEY FEATURES MARKET SEGMENT AND APPLICATIONS TRC ELECTRONICS, INC

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

Parameter Condition Min. Typ. Max. Internal Input Filter. refer to line derating graph on PA-4 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Output Voltage* (nom.)(adjustable)

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

Medical / Industrial AC-DC Power Supply 1200W with 5V/2A Standby / MEB-1K2A series

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter

SFD550-12BG Front-End Preliminary Data Sheet DC Input, 12V Output, 550 Watts

SPECIFICATION SilverStone ST30NF for Standard Switching Power Supply With Active PFC PS/2 Fanless 300W

Electrical Specifications

Features. Regulated Converter. RAC05-K/277 5 Watt Single Output RAC05- SK/277/W. AC/DC Converter

Industrial Serie +600S

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

MAD40 MULTI -OUTPUT SERIES OPP SCP OVP. 2 X 3.5 Inch AC-DC POWER SUPPLIES. UNIVERSAL INPUT RANGE UP TO 40Watts PART NUMBER STRUCTURE LOW CROSS REG.

Efficiency [%] 115VAC 230VAC. Parameter Condition Value. Line Regulation low line to high line ±0.5% max. Load Regulation 10% to 100% load ±0.5% max.

SAMSUNG ELECTRO-MECHANICS CO., LTD

Output Voltage nom. (adjustable)

Watts HCP Series

Features. Regulated Converter RAC Watt Single Output. AC/DC Converter

3 in 1 Dimmable (0-10Vdc, PWM signal, or resistance)

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 115VAC to 78% at 90VAC)

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

Model Number Output V1/V2/V3 Output I1/I2/I3 max. Ripple & Noise Efficiency(min/nom) Capacitive Load

Power Factor (2) 600 ma 90 ~ 305 Vac Vdc 34.2 W 86% 0.95 LUC-040S060RSP. Efficiency (2) Parameter Min. Typ. Max. Notes

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

50W Constant Current (700mA) Dimming LED Driver

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1. Automation Datacom IPC. Industry Measurement Telecom

PDAM500 Series 500W Power Supply

Transcription:

Features Meets U.S. DoE Efficiency Level VI and EU CoC Tier 2 Requirements No load input power Average Efficiency Up to 90W of AC-DC Power Universal Input 90-264Vac Input Range IP22 Rated Enclosure Meets Heavy Industrial Levels of EN61000 EMC Requirements Meets EN55011/CISPR11, FCC Part 15.109 Class B Conducted & Radiated Emissions, with 6db margin Approved to EN/IEC/UL60950-1, 2 nd Edition, Am. 2 E-cap life of >7 years 3 Year Warranty RoHS/REACH Compliant Description A high performance AC to DC external power supply family designed for test & measurement and industrial applications. Fully compliant with Efficiency Level VI requirements per U.S. Dept. of Energy, and also compliant to the Heavy Industrial levels of various EN61000-4-x standards for EMC. The TE90 series models also meet Class B conducted and radiated EMI per FCC Part 15, EN55022, CISPR22, with margin. Designed to allow easy integration with test and measurement equipment and other industrial applications. Model Selection Model Output Output Ripple & Line Load Output Cable Input Number Volts Current Power Noise¹ Regulation Regulation & Connector Configuration TE90A1251F01 12.0V 7.50A 90W 120mV pk-pk ±1% ±5% 6 pin Molex Type 2 Class I Desktop, TE90A1503F01 15.0V 6.00A 90W 150mV pk-pk ±1% ±5% 2.5 x 5.5 x 9.5mm TE90A1803F01 18.0V 5.00A 90W 180mV pk-pk ±1% ±5% Straight Barrel Type, TE90A2403F01 24.0V 3.75A 90W 240mV pk-pk ±1% ±5% IEC60320 C14 TE90A1251N01 12.0V 7.50A 90W 120mV pk-pk ±1% ±5% 6 pin Molex Type 2 TE90A1503N01 15.0V 6.00A 90W 150mV pk-pk ±1% ±5% Class II Desktop, 2.5 x 5.5 x 9.5mm IEC60320 C8 TE90A1803N01 18.0V 5.00A 90W 180mV pk-pk ±1% ±5% Straight Barrel Type, TE90A2403N01 24.0V 3.75A 90W 240mV pk-pk ±1% ±5% TE90A1251Q01 12.0V 7.50A 90W 120mV pk-pk ±1% ±5% 6 pin Molex Type 2 Class II Desktop, TE90A1503Q01 15.0V 6.00A 90W 150mV pk-pk ±1% ±5% 2.5 x 5.5 x 9.5mm TE90A1803Q01 18.0V 5.00A 90W 180mV pk-pk ±1% ±5% Straight Barrel Type, TE90A2403Q01 24.0V 3.75A 90W 240mV pk-pk ±1% ±5% Notes: 1. Measured at the output connector, with noise probe directly across output and load, terminated with 0.1μF ceramic and 47μF low ESR capacitors. 2. Molex p/n 39-01-2060 or equivalent. See outline drawing for pinout information. 3. For Input Class I models: For AC GND connected to output common (-), insert a B in the part number where the A is located (TE90B1251F01). 4. All specifications are typical at nominal input, full load, at 25 C ambient unless noted. IEC60320 C18 www.slpower.com TE90 Rev 2.2 01-DEC-16 1

General Specifications AC Input 100-240Vac, ±10%, 47-63Hz, 1 Turn On Time Less than 1 sec @115Vac, full load Input Current 115Vac: 1.2A, 230Vac: 0.6A Hold-up Time 20mS min., at full Load, 100Vac input Inrush Current 264Vac, cold start: will not exceed 60A Overtemperature Will shutdown upon an over-temperature condition, auto-recovery. Input Fuses F1, F2: 5A, 250Vac fuses (line & neutral lines) provided on all models Overload 130 to 180% of rating, Hiccup Mode Earth Leakage Current Input-GND: <500μA@264Vac, 60Hz, NC Output-GND: <4mA@264Vac, 60Hz, NC Short Circuit Hiccup Mode, auto recovery. Efficiency Meets US DoE Efficiency Level VI and EU CoC Tier 2 average efficiency levels Overvoltage 130 to 150% of output voltage (max. 60V on 48V model), hiccup mode Output Power 90W continuous See models chart for specific voltage model ratings. Isolation Input-Output: 4000Vac Input-Ground: 1500Vac Output-Ground: 1500Vac No Load Input Power <0.150W, Meets DoE Efficiency Level VI and EU CoC Tier 2 Requirements Safety Standards EN/CSA/UL/IEC 60950-1, 2nd Edition, Am 2 Ripple and Noise See models chart on pg 1. Operating Temperature Output Voltage See models chart on pg 1. Case Temperature Transient Response E-Cap Life 500µs response time for return to within 0.5% of final value for any 50% load step over the range of 5% to 100% of rated load, i/ t< 0.2A/µs. Max. voltage deviation is +/-3.5%. >7 year life based on calculations at 115Vac/60Hz & 230Vac/50Hz, ambient 25 C at 24 hrs per day, 365 days/year, 6 power up cycles per day. (80% load on 12V model) Temperature Derating MTBF -20 C to +70 C. Derate above 40 C. Case Temperatures are within regulatory guidelines. Care should be taken to avoid prolonged contact with skin or other heat sensitive surfaces. See Derating Chart >500,000 hours, full load, 110 & 220Vac input, 25 C amb., per Telcordia 332 Issue 6. Weight 600g Storage Temperature -40 C to +85 C Safety Drop Test 1.4m from table top to wooden platform, 6 faces. Altitude Operating: to 5000m (derate to TBD temp. above 3000m). Non-operating: -500 to 40,000 ft. Dimensions W: 2.67 x L: 6.02 x H: 1.36 W: 68mm x L: 153mm x H: 34.5mm Relative Humidity 5% to 95%, non-condensing Operating: 0.003g/Hz, 1.5grms overall, 3 axes, 10 min/axis, 1-500Hz. Non-Oper.: random waveform, 3 minutes per Vibration axis, 3 axes and Sine waveform, Vib. frequency/acceleration: 10-500Hz/1g, sweep rate of 1 octave / minutes, Vibration time of 10 sweeps / axes, 3 axes All specifications are typical at nominal input, full load, at 25 C ambient unless noted. Shock Operating: Half-sine, 20gpk, 10mS, 3 axes, 6 shocks total Non-Operating: Half-sine waveform, impact acceleration of 100G, Pulse duration of 6 ms, Number of shocks: 3 for each of the three axis www.slpower.com TE90 Rev 2.2 01-DEC-16 2

EMI/EMC Compliance Conducted Emissions: Radiated Emissions: Common Mode Noise: Electro-Static Discharge (ESD) Immunity on Power ports: Radiated RF EM Fields Susceptibility Electrical Fast Transients (EFT) /Bursts: Surges, Line to Line (Diff Mode) and Line to GND (CMN Mode) Conducted Disturbances induced by RF Fields Rated Power frequency magnetic fields Voltage Interruptions, Dips, Sags & Surges Harmonic Current Emissions Flicker Test EN55011/CISPR22 Class B, FCC Part 15.107, Class B: 6db margin typ, at 115 and 230Vac EN55022/CISPR22 Class B, FCC Part 15.109, Class B: 3db margin typ, at 115 and 230Vac High Frequency (100kHz-20MHz): <40mA pk-pk EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz EN55024/IEC61000-4-4, Level 4, +/- 4kV, 100Khz rep rate, 40A, Criteria A EN55024/IEC61000-4-5, Level 4, +/-2kV DM, +/-4kV CM, Criteria A EN55022/IEC61000-4-6, 10Vrms Level 4, in ISM and amateur radio bands between 0.15Mhz and 80Mhz, 80% AM at 1KHz EN55024/IEC1000-4-8, Level 4: 30 A/m, 50/60 Hz EN55024/IECEN61000-4-11: --100% dip for 10 ms, at 0, 45, 90, 135, 180, 225, 270 and 315 degrees; 20mS at 0 degrees. Criteria A --100% dip for 5000mS (250/300 cycles), Criteria B --60% dip for 100mS, Criteria B --30% dip for 500mS, Criteria A EN55011/EN61000-3-2, Class A EN61000-3-3 Notes: Performance criteria are based on EN55024. According to the standards, performance criteria are defined as following: A Normal performance during and after the test B Temporary degradation, self-recoverable C Temporary degradation, operator intervention required to recover the operation D Permanent damage Derating Chart: 100 90 80 Output Power - Wwatts 70 60 50 40 30 20 10 0-20 -10 0 10 20 30 40 50 60 70 Ambient Temperature - C 12V-24V www.slpower.com TE90 Rev 2.2 01-DEC-16 3

Mechanical Drawing: Notes: 15V through 24V Models: 2.5 x 5.5 x 9.5mm 12V Models: Output Connector: 6 pin Molex 39-01-2060 Barrel Connector,. or equiv. Pins 1, 4 = (+), pins 3, 6 = (-), pins 2, 5 = NC 1) All dimensions in mm. 2) The unit should not be covered or enclosed to protect against excessive case temperature rise. Connector Information Standard models include a 2.5 x 5.5 x 9.5mm straight barrel type connector (Ault #3),. (#51 for the 12V models). Other standard options are listed below. The 03 in the standard model number is replaced by the applicable digits below: www.slpower.com TE90 Rev 2.2 01-DEC-16 4

Efficiency Level VI Information: TE90A Series Data Sheet 2016 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com TE90 Rev 2.2 01-DEC-16 5