Transformer protection IED RET 670

Similar documents
Transformer Fault Categories

BUS2000 Busbar Differential Protection System

Stabilized Differential Relay SPAD 346. Product Guide

Transformer Protection

Shortcomings of the Low impedance Restricted Earth Fault function as applied to an Auto Transformer. Anura Perera, Paul Keller

2015 Relay School Bus Protection Mike Kockott March, 2015

SPAD 346 C Stabilized differential relay

Extensive LV cable network. Figure 1: Simplified SLD of the transformer and associated LV network

S1-3: New and re-discovered theories and practices in relay protection

Transformer Protection Principles

This webinar brought to you by the Relion product family Advanced protection and control IEDs from ABB

Power System Protection Manual

Detecting and Managing Geomagnetically Induced Currents With Relays

www. ElectricalPartManuals. com Transformer Differential Relay MD32T Transformer Differential Relay

Modern transformer relays include a comprehensive set of protective elements to protect transformers from faults and abnormal operating conditions

This webinar brought to you by The Relion Product Family Next Generation Protection and Control IEDs from ABB

Bus Protection Fundamentals

Differential Protection with REF 542plus Feeder Terminal

Transformer differential protection

Study Committee B5 Colloquium 2005 September Calgary, CANADA

Unit Protection Differential Relays

STRAY FLUX AND ITS INFLUENCE ON PROTECTION RELAYS

Generator Protection GENERATOR CONTROL AND PROTECTION

Hands On Relay School Open Lecture Transformer Differential Protection Scott Cooper

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

Sequence Networks p. 26 Sequence Network Connections and Voltages p. 27 Network Connections for Fault and General Unbalances p. 28 Sequence Network

PD300. Transformer, generator and motor protection Data sheet

Solution for Effect of Zero Sequence Currents on Y-Y Transformer Differential Protection

Improving Transformer Protection

Substation applications

Transformer Protection

Optimizing HV Capacitor-Bank Design Protection & Testing

NTG MULTIFUNCTON GENERATOR PROTECTION RELAY. NTG-Slide

Reyrolle Protection Devices. 7SG14 Duobias M Transformer Protection. Answers for energy

Summary Paper for C IEEE Guide for Application of Digital Line Current Differential Relays Using Digital Communication

www. ElectricalPartManuals. com Generator Differential Relay MD32G Rotating Machine Differential Relay

7SG14 Duobias-M Transformer Protection

Hands On Relay School Open Lecture Transformer Differential Protection Scott Cooper

COPYRIGHTED MATERIAL. Index

Protection of a 138/34.5 kv transformer using SEL relay

RAIDK, RAIDG, RAPDK and RACIK Phase overcurrent and earth-fault protection assemblies based on single phase measuring elements

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

EASUN REYROLLE LIMITED

function block description to the differential protection and restricted earth-fault protection functions for autotransformers

Hamdy Faramawy Senior Application Specialist ABB Sweden

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec SWITCH GEAR AND PROTECTION. (Electrical and Electronics Engineering)

RET670/650 for Traction Applications Protection Schemes for Special Railway Transformers

Catastrophic Relay Misoperations and Successful Relay Operation

200ADM-P. Current Injection System with Phase Shift A 3.000s 2.000A 50.00Hz 0.0. Features

Power System Protection. Dr. Lionel R. Orama Exclusa, PE Week 3

Optimizing HV Capacitor Bank Design, Protection, and Testing Benton Vandiver III ABB Inc.

NOVEL PROTECTION SYSTEMS FOR ARC FURNACE TRANSFORMERS

N. TEST TEST DESCRIPTION

Transformer differential protection RADSB

XD1-T - Transformer differential protection relay

System Protection and Control Subcommittee

PIPSPC. Prepared by Eng: Ahmed Safie Eldin. And. Introduction. Protection Control. Practical. System. Power

N. TEST TEST DESCRIPTION

Earth Fault Protection

PJM Manual 07:: PJM Protection Standards Revision: 2 Effective Date: July 1, 2016

Protection Basics Presented by John S. Levine, P.E. Levine Lectronics and Lectric, Inc GE Consumer & Industrial Multilin

Communication set-up for Relion 670-series 2.0 using PCM or later Setting and application guide

Application of Low-Impedance 7SS601 Busbar Differential Protection

Centralized busbar differential and breaker failure protection function

Phase Shifting Transformers. Presented by

16 Transformer and Transformer-feeder Protection

HV SHUNT REACTOR SECRETS FOR PROTECTION ENGINEERS

SIPROTEC 5 Application. SIP5-APN-025-en: 7UT8 Autotransformer bank with 2 sets of CT inside the delta connection of the compensation side

Replacement solution

Modular range of digital protection relays

Performance Analysis of Traditional and Improved Transformer Differential Protective Relays

Protective Relays Digitrip 3000

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR).

PROTECTION of electricity distribution networks

SPAD 346 C. Stabilized Differential Relay. User s manual and Technical description SPAD 346 C V ~ V. f n SPCD 3D53 SPCJ 4D28

Tab 2 Voltage Stresses Switching Transients

Line protection with transformer in the protection zone

INSTRUCTION MANUAL TRANSFORMER PROTECTION RELAY GRT100 - B

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation

Modular multifunction generator protection

O V E R V I E W O F T H E

Multimeter 500CVD21 RTU500 series

XD1-T Transformer differential protection relay. Manual XD1-T (Revision A)

Type: ADR233A (ADITYA V2 Series) (Preliminary) ASHIDA Numerical 3 Phase Tx. Differential Protection Relay

Data. Dr Murari Mohan Saha ABB AB. KTH/EH2740 Lecture 3. Data Acquisition Block. Logic. Measurement. S/H and A/D Converter. signal conditioner


NERC Protection Coordination Webinar Series June 16, Phil Tatro Jon Gardell

Appendix S: PROTECTION ALTERNATIVES FOR VARIOUS GENERATOR CONFIGURATIONS

NERC Protection Coordination Webinar Series June 9, Phil Tatro Jon Gardell

Impedance protection on power transformer.

AUTOMATIC CALCULATION OF RELAY SETTINGS FOR A BLOCKING PILOT SCHEME

Railway application RER670 Version 2.2 IEC Type test certificate R E L I O N 670 SERIES

International Journal of Advance Engineering and Research Development ANALYSIS OF INTERNAL AND EXTERNAL FAULT FOR STAR DELTA TRANSFORMER USING PSCAD

Restricted earth-fault protection function block description

Current Transformer Requirements for VA TECH Reyrolle ACP Relays. PREPARED BY:- A Allen... APPROVED :- B Watson...

g GE POWER MANAGEMENT

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

3 Pole high impedance differential relay 7VH83

Alberta Interconnected Electric System Protection Standard

Harmonic restraint earth fault or single-phase overcurrent protection

Transcription:

Gunnar Stranne Transformer protection IED RET 670 Santiago Septiembre 5, 2006 1

Transformer protection IED RET670 2 Introduction features and applications Differential protection functions Restricted Earth Fault protection function High Impedance Differential protection function Some additional functions and application examples Preconfigured ready-made packages Summary and conclusions

Benefits of RET670 outstanding features Half cycle operating time a new performance standard! One or two differential functions Differential function compensated automatically for tap changer position for improved sensitivity An additional sensitive and fast differential function based on negative sequence current - ~1% sensitivity High impedance or low impedance restricted earth-fault differential protection for each winding Possibility to use multi - CT arrangements for increased differential protection stability Tap changer control 3 Breaker control, measuring, monitoring and recording

Applications Power transformers, including autotransformers, reactors and generator transformer blocks Two or three vector group (or winding) transformers Single- or multi circuit breaker arrangements Up to six stabilized 3-phase current inputs 4

Three-winding Transformer Three-winding variant up to 6 restraint three-phase CT inputs Ensures enhanced throughfault stability for multibreaker arrangements Tap changer control 5

Auto Transformer Phased segregated biased differential protection for Autotransformers in 1½ CB applications Serial and common windings Up to 4 three-phase CT inputs 6

Phase Shifting Transformer Transformer key data 1400 MVA 400/ 400 kv +-25 1200 tons 32 MUSD contract 7 Project aspects Cooperation between End User, Relay Manufacturer & PST Manufacturer is of outmost importance Cooperation required in the very early design stage of the project

Shunt Reactor Protection And Control Protection Phase segregated biased differential protection High-impedance differential protection Over/under-voltage protection Switching control for lines and busses 8 RET 670 is optimized for each application with maximum reliability and short operating time

Step-up Transformer In Power Stations Overall differential protection of a generator transformer unit Differential protection for the step-up transformer and/or the auxiliary transformer Back-up protection functionality 9

Complementary Protection Functions Full scheme distance Overcurrent 19 inverse Thermal overload Breaker failure Voltage functions with high reset ratio 10 RET 670 fits all power system elements that require unit and additional protection functionality

Differential Protection Two-winding or three-winding functions Two-winding variant up to 4 three-phase CT inputs Enhanced through-fault stability for multi-breaker arrangements Three-winding variant up to 6 three-phase CT inputs Enhanced through-fault stability for multi-breaker arrangements 11

Transformer Protection Terminal Differential Protection of 2- winding Power Transformers 2- winding power transformer 2- winding power transformer with unconnected delta tertiary winding 2- winding power transformer with 2 circuit breakers on primary side 2- winding power transformer with 2 circuit breakers on secondary side 12 - winding power transformer with 2 circuit breakers on both sides

Transformer Protection Terminal Differential Protection of 3- winding Power Transformers 3- winding power transformer with all 3 windings connected 3- winding power transformer with 2 circuit breakers on (any) one side, (e.g. 2 parallel power lines on one side) 13 3- winding power transformer with 2 circuit breakers on 2 out of 3 sides, (e.g. a meshed power network) Note! Also 3-out of 3 with 2 breakers is possible.

Differential Protection A differential current does not always mean there is a fault in the transformer Inrush current in power transformers Saturation of current transformers Overexcitation Tap changer position etc. Means of coping with these situations must be included in the design 14

Differential Protection Ability is included to handle two tap changers, i.e. one tap changer per winding on any two windings Functionality Three-section settable restrain characteristic High set unrestrained operation Idiff Idunre Unrestrained operation operate 1.0 pu Idmin 1.25 pu restrain Ibias 15

Transformer Inrush Current Stabilization Second harmonic stabilisation Wave form stabilisation wave block CT saturation cause a second harmonic component in the secondary current 16 Transformer inrush currents contain a percentage of second harmonic current. This is used for discrimination but second harmonic blocking normally causes delayed operation in case of CT saturation. It is also possible to monitor the shape of the differential current signal. The low-current gap measurement indicates inrush.

Transformer Inrush Current Stabilisation Internal fault followed by CT saturation Delayed trip of the restrained differential function due to the traditional use of second harmonic blocking (Set level 15 %) 17

Overvoltage Stabilization The fifth harmonic component is used for stabilization 3 2 1 Magnetizing current at system overvoltage i L1 i L2 i L3 0-1 -2-3 18 The fifth harmonic component appears as a characteristic quantity in the transformer magnetizing current during overvoltage.

Differential Protection DIFP- application 19 Two- and three winding applications Stabilization of up to 6 inputs Inrush current stabilization Second harmonic Waveform Phase segregated Selectable Cross-blocking 5th harmonic stabilization at overvoltage Sensitivity influenced by tap changer position (selectable) Selectable subtraction of zero sequence currents

Differential Protection Blocking condition: 2 nd harmonic, 5 th harmonic waveblock, cross block & Neg Seq Int / Ext Fault Discriminator internal sensitive & restrained unrestrained 1 TRIP START 20

Differential Protection Testing RET670 for maximum performance Fault detection in 7 ms! 21

Negative sequence current differential function Internal / external fault discriminator Based on the measurement of negative sequence current 22

Negative sequence current differential function Before comparison, all negative sequence currents are compensated for turns ratio and vector group phase displacement External fault: 180 relative phase displacement Internal fault: 0 relative phase displacement IminNegSeq 2% - 20% Default 4% 23 NegSeqROA 30 120 Default 60

Negative sequence current differential function An internal fault with heavy CT saturation Directional Comparison Criterion: Internal fault as seen from the HV side 120 90 35 ms 60 excursion from 0 degrees due to CT saturation 150 30 definitely an internal fault 24 external fault region 180 0 210 240 270 0.5 ka 1.0 ka 1.5 ka HV side contribution to the total negative sequence differential current in ka Directional limit (within the region delimited by ± 60 degrees is internal fault) 300 330 trip command in 12 ms Internal fault declared 7 ms after internal fault occurred

Negative Sequence Differential Protection An internal small transformer interturn fault was cleared by Buckholz relay and existing differential protection failed to detect fault Test of RET 670 with recorded signals proved successful If one or the other of currents is too low, then no measurement is done External fault region Directional Comparison Criterion: Internal fault as seen from the HV side 150 210 120 20 A 90 8 19 10 180 0 30 A 60 (negseqroa = ± 60 deg) 30 330 steady-state position for this internal fault Internal fault declared 12 ms after fault 25 240 40 A 50 A 270 300 Contribution to total neg. seq. diff. current from HV side (in A) Directional limit (within ± negseqroa degrees is internal fault)

26 Negative sequence current function - summary Fast operating times half cycle Start from ordinary differential protection required, but blocking conditions are bypassed Sensitive negative sequence protection Gives sensitive turn-to-turn fault protection The trip request must be confirmed several times in succession before the final trip request is placed this security feature causes an increase in the operating time The operating time is about 30ms for very lowlevel turn-to-turn faults This sensitive negative sequence protection is blocked for high fault current conditions

Restricted Earth Fault Protection diff current in pu Operate characteristic minimum base sensitivity 50 % default base sensitivity 30 % maximum base sensitivity 5 % Step : 1 % transformer rated current 27 0 1 2 3 4 5 6 1.25 pu bias current in per unit

Restricted Earth Fault Protection Internal fault External fault zone of protection zone of protection I L1 I L1 I L2 I L2 I L3 I L3 3I 0 I N I FAULT I I FAULT N 3I 0 I N I N internal fault external fault 3I 0 MTA ROA reference is neutral current MTA ROA 3I 0 operate for internal fault ROA -I N restrain for external fault operate for internal fault ROA -I N restrain for external fault reference is neutral current 28

Differential Protection 29 Switch-on-to-fault Built-in logic to improve operating speed for switch-on-to-fault condition Possible to record the differential currents and/or bias current by the disturbance recorder channels 31-40 Differential currents Instantaneous or RMS Bias current RMS

Restricted Earth Fault Protection 3I0 < 3% of Ibase I N > 50% of Idset Directional check 1 1 TRIP START 30

Restricted Earth Fault Protection Up to 4 three-phase CT inputs makes it possible to handle autotransformers in 1½ CB applications Enhanced function for autotransformer applications I1 I2 I3 I3P I1 I2 I3 I1 I2 I3 I3P I3P REFx I1 I3PRI1 I3PRI2 I3SEC1 I3SEC2 I I1N 31

Restricted Earth Fault Protection 32 Switch-on-to-fault Built-in logic to improve operating speed for switch-on-to-fault condition Possible to record differential currents and/or bias current by the disturbance recorder Differential currents Instantaneous or RMS Bias current RMS

High Impedance Differential Protection Three instances 1 or 3 high impedance differential External stabilizing resistors & metrosils are used Typical applications High impedance REF Restricted Earth Fault protection Tee - feeder differential protection Bus differential 33

Overexcitation Protection V/Hz measurement Positive sequence or single phase-to-phase voltage Transformer magnetic core cooling time constant setting IEEE inverse time and User defined trip curves available Alarm level as percentage of trip level 34

Thermal Overload protection function 49-1 Ith 86/94 I->O 49-1 Ith Two thermal overload functions Tripping of load will give cooling chance to restore normal temperatures. Settable thermal time constants for short circuits and low overloads Measures RMS current Lockout reset level (in % of heat content trip value) 86/94 I->O Alarm levels 1 and 2 (each in % of heat content trip value) 35

TOF/TUF/RVF(df/dt) Frequency Protection Over-frequency and under-frequency Six steps OF & UF settable frequency and time delay Measures Ph-Ph or Positive sequence voltage Under-voltage blocking Df/dt with positive or negative derivative setting High accuracy Short operating time Accuracy 2 mhz for three phase Accuracy 10 mhz for single phase 36 Voltage dependent tripping time possible!

Frequency Protection - Applications Under frequency 37 Load shedding systems Remedial action schemes Over frequency Generation shedding Remedial action schemes Rate-of-change of frequency Generation shedding Load shedding Remedial action schemes

Six Pre-configured RET 670 - Ready To Use RET 670-A30 Two winding transformer, single circuit breaker RET 670-B30 Two winding transformer, multi circuit breaker (1½ CB or double CB on either, or both, sides of the transformer) RET 670-A20 Three winding transformer, single circuit breaker RET 670-A31 Three winding transformer, single circuit breaker, current and voltage inputs RET 670-A40 Three winding transformer, single circuit breaker (1½ CB or double CB on any, or all, sides of the transformer) RET670 B40 Three winding transformer, multi circuit breaker (1½ CB or double CB on any, or all, sides of the transformer) 38

Two Winding Transformer Single Circuit Breaker DR 50BF 3I>BF 50/51-1 3I> 86/94 I->O RET 670-A30 81O/81U f</> O5 51N-1 I 87N-1 Ind> 87T 3Id/I> 52PD PD 24 U/f> O4 87N-2 Ind> 59N UN 59N UN 51N-2 I 59 3U> 27 3U< O2 60 FF 50BF 3I>BF 90 VCTR 50/51-2 3I> 86/94 I->O 21 Z< O1 25/27 SC/VC 60 FF 59 3U> 27 3U< DR Contr Interl O3 39

Two Winding Transformer Multi Circuit Breaker 50BF 3I>BF 60 FF 25/27 SC/VC 60 FF 50BF 3I>BF 51N-1 I 50BF 3I>BF Σ DR 50/51-1 3I> 87N-1 Ind> 87T 3Id/I> 87N-2 Ind> 59N UN 51N-2 I 50/51-2 3I> 59 3U> 86/94 I->O 86/94 I->O 81O/81U 2* f</> O8 52PD PD 24 U/f> 50BF 3I>BF 59N UN 59 3U> 27 3U< 21 Z< 27 Contr 3U< Interl DR RET 670-B30 2* 2* 25/27 SC/VC O7 O6 O4 O5 O2 O1 O3 40

Three Winding Transformer Single Circuit Breaker 51N-1 I DR 50BF 3I>BF 50/51-1 3I> 87N-1 Ind> 87T 3Id/I> RET 670-A20 86/94 I->O 60 FF 25/27 SC/VC 24 U/f> 51N-3 I 87N-3 INd> O6 O4 O5 87N-2 Ind> 59N UN 50BF 3I>BF 50/51-3 3I> 59N UN 51N-2 I 59 3U> 27 3U< O2 60 FF 25/27 SC/VC 60 FF 50BF 3I>BF 50/51-2 3I> 59 3U> 27 3U< DR 86/94 I->O 86/94 I->O 21 Z< Contr Interl 81O/81U f</> 52PD PD O1 O3 O7 41

Three Winding Transformer Multi Circuit Breaker 50BF 3I>BF Σ DR 50BF 3I>BF 50/51-1 3I> RET670 B40 86/94 I->O 81O/81U f</> 52PD PD 60 FF 25/27 SC/VC O7 O8 O6 50BF 3I>BF 50/51-3 3I> 60 FF 25/27 SC/VC 60 FF 51N-1 I 50BF 3I>BF 87N-1 Ind> 87T 3Id/I> 87N-2 Ind> 59N UN 51N-2 I 50/51-2 3I> 59 3U> 27 3U< DR 86/94 I->O 86/94 I->O 24 U/f> 51N-3 I 87N-3 INd> 59N UN 59 3U> 27 3U< 21 Z< Contr Interl O4 O5 O2 O1 O3 42

Benefits of RET670 Functional flexibility Every step you take - ABB has the solution 43 Configuration flexibility High performance User friendly Pre-defined packages IED 670 series member means; Less spare parts needed Simplified engineering and maintenance Common look and feel and common tools Extensive Self-supervision Remote communication flexibility Easy integration in Substation Automation Systems

Benefits of RET670 outstanding features 44 Fast, sensitive and secure differential function tap-changer compensated Fast and sensitive negative sequence differential function -> half cycle operation Multi-CT inputs increases security and functionality High or low impedance restricted earthfault winding differential funcions Extensive function library and options Up to 12 general I -V functions; distance and extra differential functions High reset voltage functions Extendable analog and digital I/O Full control functionality Large HMI option

Potencia y productividad para un mundo mejor