LIQ_MAN_ABR_5081P-FF-FI/Rev. D January 2015

Similar documents
ESSENTIAL INSTRUCTIONS Read this page before proceeding!

LIQ_MAN_ABR_5081T-HT/Rev. L January 2015

Instruction Manual LIQ_MAN_5081A-FF/rev.M January A. FouNdAtIoN Fieldbus two-wire Chlorine, dissolved oxygen, and ozone transmitter

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers

FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

CERTIFICATE OF COMPLIANCE

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Instruction Manual PN P/rev.H November Model 5081-P. Two-Wire ph/orp Transmitter

Instruction Manual PN A-HT/rev.L January Model 5081-A-HT. HART Two-Wire Chlorine, Dissolved Oxygen, and Ozone Transmitter

Loop Powered Indicator

IP26 Series Current to Pneumatic Converter

IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Thie. Automation Products Rev. Chang Date Name Supersedes Dwg. : Part Class:

TWO-WIRE TRANSMITTERS FOR ph, ORP, CONDUCTIVITY, OXYGEN, OZONE, AND CHLORINE

Intrinsic Safety Control Drawing

TwO-wIRE TRANSmITTERS FOR ph, ORP, CONDUCTIvITy, OxygEN, OzONE, AND CHLORINE

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Instruction Manual PN 51-Xmt-P/rev.C February Model Solu Comp Xmt-P ph, ORP, and Redox Transmitter

Instruction Manual PN 51-Xmt-T/rev.C February Model Solu Comp Xmt-T Two-Wire Toroidal Conductivity Transmitter

JM Enclosure Dimensions (in mm)

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

MCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

D1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

AH71, AH72, and AH73 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions

EN Series Installation Manual

Product manual wire programmable RTD transmitter

HT880 and HT885 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions

1066 Liquid Analytical Fieldbus ph/orp Transmitter Transmitter Instruction Manual LIQ_MAN_1066-P-FF September 2013

1-830 SERIES DISPLACEMENT TRANSMITTER

Model LD-LPIX EXPLOSION-PROOF LOOP POWERED INDICATOR

Power supply. Calibration. Surface finishing. Seal. Process connection

TUpH 396RVP and 398RVP Retractable ph/orp Sensors

User s Manual. Manual Change No V-E. Please use the attached sheets for the pages listed below in IM 01F06F00-01EN (7th).

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

Instruction Manual PN A-HT/rev.C July Model 5081-A-HT. HART Smart Two-Wire Chlorine, Dissolved Oxygen, and Ozone Transmitter

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Interface DIN-Rail Models D1034S, D1034D D1034S - D1034D

Fisher 646 Electro Pneumatic Transducer

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

DPharp Differential Pressure and Pressure Transmitters

Instruction Manual PN A-FF/rev.H March Model 5081-A FOUNDATION Fieldbus Two-Wire Chlorine, Dissolved Oxygen, and Ozone Transmitter

Level Lance Model 5100

QN5O, QXBO, QNBO, QX7O, QN7O, QXCO, QNCO

White Paper. Requirements for fieldbus equipment installed in a Zone 2 and Division 2 hazardous area environment. March 24, 2005

FLEX Ex Power Supplies

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

ControlWave INTRINSICALLY SAFE PROXIMITY SENSOR INTF. BOARD

User s Manual YOKOGAWA. Model PH202G (S) ph Transmitter. IM 12B6C3-E-E 12th Edition

Certificate of Compliance

Universal Intelligent 2-wire DIN Rail Transmitters

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

Industrial Pressure Transducers

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters

General Specifications

ATEX Installation Drawings and Instructions

General Specifications

Head mounted Temperature Transmitter TF02/TF02-Ex

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

Fisher 646 Electro-Pneumatic Transducers

User's Manual Model SE14 Magnetic Flow Converter

General Specifications

Features and Applications

[ Rosemount 648 Wireless Temperature Transmitter. Rosemount 648 Wireless. Quick Installation Guide , Rev CA August 2011

Rosemount 3101, 3102, and 3105

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

EJX and EJA-E Series Differential Pressure and Pressure Transmitters Installation Manual. Contents 1. Introduction. 3. Installation. 5.

Safety Instructions Proline Promag 500

Submersion/Insertion Toroidal Sensor

Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc

INTRINSIC SAFETY BASIC PRINCIPLES

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

ABB MEASUREMENT & ANALYTICS DATA SHEET. TB82 2-wire conductivity transmitters

Universal Intelligent 2-wire DIN Rail Transmitters

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

R88000 T (including ATEX)

INTRINSICALLY SAFE DUPLEXER

FLEX Ex V ac In/Quad-Ex dc Out Power Supply

Rosemount 148 Temperature Transmitter

Rosemount 248 Wireless Temperature Transmitter

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters

Fisher 4200 Series Electronic Position Transmitters

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

Installation guide 971 SmartRadar LTi

PROline promag 53 Division 1

Rosemount 648 Wireless Temperature Transmitter

Micro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc

FLEX Ex Thermocouple/RTD Input Module

Rosemount 148 Temperature Transmitter

MEAS CAL ALARM CONF APT2000 TC

Transcription:

instruction Sheet 1a-01p-ff/fi LIQ_MAN_ABR_01P-FF-FI/Rev. D January 201 FOUNDATION fieldbus Two-Wire ph/orp Transmitter ESSENTIAL INSTRUCTIONS Read this page before proceeding! Your Rosemount Analytical instrument from Emerson Process Management is one of the finest available for your particular application. These instruments have been designed, and tested to meet many national and international standards. Experience indicates that its performance is directly related to the quality of the installation and knowledge of the user in operating and maintaining the instrument. To ensure their continued operation to the design specifications, personnel should read this manual thoroughly before proceeding with installation, commissioning, operation, and maintenance of this instrument. If this equipment is used in a manner not specified by the manufacturer, the protection provided by it against hazards may be impaired. Failure to follow the proper instructions may cause any one of the following situations to occur: Loss of life; personal injury; property damage; damage to this instrument; and warranty invalidation. Ensure that you have received the correct model and options from your purchase order. Verify that this manual covers your model and options. If not, call 1-00--2 or --00 to request correct manual. For clarification of instructions, contact your Rosemount representative. Follow all warnings, cautions, and instructions marked on and supplied with the product. Use only qualified personnel to install, operate, update, program and maintain the product. Educate your personnel in the proper installation, operation, and maintenance of the product. Install equipment as specified in the Installation section of this manual. Follow appropriate local and national codes. Only connect the product to electrical and pressure sources specified in this manual. Use only factory documented components for repair. Tampering or unauthorized substitution of parts and procedures can affect the performance and cause unsafe operation of your process. All equipment doors must be closed and protective covers must be in place unless qualified personnel are performing maintenance. If this equipment is used in a manner not specified by the manufacturer, the protection provided by it against hazards may be impaired. Special condition for intrinsically Safe use The 01 enclosure is made of aluminum alloy and given a protective polyurethane finish; however, care must be taken to protect it from impact, abrasion or friction with other metal surfaces if located in zone 0.

1a-01p-ff/fi January 201 Specifications physical SpecificaTionS Housing: Cast aluminum with epoxy coating. Type X (IP). Neoprene O-ring cover seals. dimensions:.3 in. x. in. x. in. (10 mm x 1 mm x mm); diameter.1 in (1 mm) Conduit Openings: 3/ in. FNPT reference impedance: Transmitter accepts high impedance (i.e. glass) reference electrodes as well as low impedance (i.e. silver-silver chloride) reference electrodes. response Time: Display reaches % of final reading within seconds. Temperature Sensors: The following RTDs can be used with the Model 01-P ph/orp transmitter: 3 and wire Pt 0 RTDs 3 and wire Pt 00 RTDs Transmitter can also be used with two-wire RTDs. Temperature range: F to 2 F (-1 C to 0 C) local display: Two line LCD; first line shows process variable (ph or ORP), second line shows temperature and output signal. When triggered, fault and warning messages alternate with temperature and output readings. Process variable: segment LCD, 0. in. (20 mm) high Temperature/output: segment LCD, 0.3 in. ( mm) high Display board can be rotated 0 degrees clockwise or counterclockwise. During calibration and programming, messages and prompts appear in the temperature/output area. power Supply and load requirements: A power supply voltage of -32 Vdc at 22 ma is required. Security: User selected security code prevents accidental changes to program settings. ambient Temperature: - to 1 F (-20 to C) relative Humidity: 0 to % (with covers sealed) Storage Temperature: -22 to 1 F (-30 to 0 C) ce: emi/rfi certified: EN2-1 instruction Sheet LIQ_MAN_ABR_01P-FF-FI/Rev. D HazardouS area classification: intrinsic Safety: Class I, II, III, Div. 1 Groups A-G T Tamp = 0 C Exia Entity Class I, Groups A-D Class II, Groups E-G Class III T Tamb = 0 C IECEx BAS 0.01X Ex ia IIC T Ga ATEX 000 II 1 G Baseefa03ATEX00 EEx ia IIC T Tamb = -20 C to + C non-incendive: Class I, Div. 2, Groups A-D Dust Ignition Proof Class II & III, Div. 1, Groups E-G Type X Enclosure Class I, Div. 2, Groups A-D Suitable for Class II, Div. 2, Groups E-G T Tamb = 0 C explosion-proof: Class I, Div. 1, Groups B-D Class II, Div. 1, Groups E-G Class III, Div. 1 Class I, Groups B-D Class II, Groups E-G Class III Tamb = C max Sira mc001/00 2

instruction Sheet 1a-01p-ff/fi LIQ_MAN_ABR_01P-FF-FI/Rev. D January 201 SpecificaTionS ph ph input range: 0 to 1 ph Temperature input range: F to 2 F (-1 C to 0 C) accuracy at 2 c: ±0.01 ph repeatability at 2 c: ±0.01 ph resolution: 0.01 ph and 0.1 C or F Stability at 2 c: 0.2% per year Temperature compensation: Automatic or manual between F to 2 F (-1 C to 0 C) Solution Temperature compensation: Transmitter will convert ph measured at any temperature to the ph at 2 C. Temperature coefficient is programmable between -0.0 ph/ C and 0.02 ph/ C fieldbus SpecificaTionS device itk profile: (Released for ITK.0.0/.0.1) Manufacturer identification (Manufac_id): 0x21 device Type (dev_type): 0x0 device revision (dev_rev): 0x03 physical layer profiles: 1, 3, linkmaster: Yes number of link objects: 20 Vcr s Supported: 20 SpecificaTionS - orp orp input range: -0 to 0 mv Temperature input range: F to 2 F (-1 C to 0 C) output Scale expansion: Continuously expandable between -0 and 0 mv accuracy at 2 c: ±1 mv repeatability at 2 c: ±1 mv resolution: 1 mv and 0.1 C or F Stability at 2 c: 0.2% per year 3

1a-01p-ff/fi January 201 instruction Sheet LIQ_MAN_ABR_01P-FF-FI/Rev. D Wiring Wire sensor per Figure 1. Refer to the sensor instruction manual for more details. If your sensor has an integral preamplifier or you are using a remote preamplifier, you will need to change the preamplifier location in the program menu. Please see Figure 1. Select trans for integral preamplifier or SnSr for J-box or sensor preamplifier. wiring THrougH a junction box with remote preamplifier Wire sensor as shown in Figure. Refer to the sensor instruction manual for more details. wiring THrougH a junction box Sensors with integral preamplifiers can be wired to the analyzer through a remote junction box (PN 230-00). Wire the extension cable and sensor cable point-to-point. Refer to the sensor instruction manual for more details. power wiring For general purpose areas, wire power as shown in Figure 1. For hazardous areas, please see hazardous area installation drawings. figure 1. 01-p-ff/fi wiring details

instruction Sheet 1a-01p-ff/fi LIQ_MAN_ABR_01P-FF-FI/Rev. D January 201 figure 2. exploded View of 01-p-ff/fi figure 3. wiring diagram Sensor with preamplifier DWG. NO. 01P30vA

1a-01p-ff/fi January 201 instruction Sheet LIQ_MAN_ABR_01P-FF-FI/Rev. D figure. wiring diagram sensor 31+ with preamplifier figure. wiring Through a junction box with remote preamplifier DWG. NO. 01P2vA DWG. NO. 01P2vA

instruction Sheet 1a-01p-ff/fi LIQ_MAN_ABR_01P-FF-FI/Rev. D January 201 Installation unpacking and inspection Inspect the shipping container. If it is damaged, contact the shipper immediately for instructions. Save the box. If there is no apparent damage, unpack the container. Be sure all items shown on the packing list are present. If items are missing, notify Rosemount Analytical immediately. rotating THe display The 01P-FF/F1 display can be rotated 0 left or right. Disengage the cover lock and remove the front cover. Remove the three screws holding the PCB stack and gently lift the display board. Do not disengage the ribbon cable between the display board and the CPU board. Rotate the display. The black infrared sensor will be at the top of the display. installation See Figure. 1. Although the analyzer is suitable for outdoor use, do not install it in direct sunlight or in areas of extreme temperatures. 2. Install the analyzer in an area where vibrations and electromagnetic and radio frequency interference are minimized or absent. 3. Keep the analyzer and sensor wiring at least one foot from high voltage conductors. Be sure there is easy access to the analyzer.. The conduit connections on the sides of the 01 housing should be sealed to prevent moisture from entering the enclosure.. The transmitter must not be mounted with both conduit openings at the top. figure. Mounting 01-p-ff/fi INCH MILLIMETER DWG. NO. 001vB

1a-01p-ff/fi January 201 instruction Sheet LIQ_MAN_ABR_01P-FF-FI/Rev. D figure. fm intrinsically Safe label 1.30 ±.02 X R.2 O..0 ±.01 D2 2.10 2. ±.02 2X FULL R 23-00/D. 2X..0 ±.01 FINISH: SILKSCREEN BLACK EPOXY PAINT (BAKED). 3. ARTWORK IS SUPPLIED BY ROSEMOUNT ANALYTICAL. 2. NO CHANGE WITHOUT FM APPROVAL. 1 MATERIAL: AISI 300 SERIES STAINLESS STEEL.01+/-.00 THICK. MATERIAL TO BE ANNEALED & PASSIVATED. MAXIMUM HARDNESS BRINELL 10. NOTES: UNLESS OTHERWISE SPECIFIED D1 DWG. NO. 2-01

instruction Sheet 1a-01p-ff/fi LIQ_MAN_ABR_01P-FF-FI/Rev. D January 201 figure. fmrc explosion-proof installation DWG. NO. 021

1a-01p-ff/fi January 201 instruction Sheet LIQ_MAN_ABR_01P-FF-FI/Rev. D figure. fm intrinsically Safe installation (1 of 2) HAZARDOUS AREA FIELDBUS FM INTRINSIC SAFETY INSTALLATION +PH SENSOR 01-P-FF IS CLASS I, II, III, DIVISION 1, GROUPS A, B, C, D, E, F, G; NI CLASS I, DIVISION 2, GROUPS A,B,C,D; SUITABLE CLASS II, DIVISION 2, GROUPS F & G; SUITABLE CLASS III, DIVISION 2 1 2 3 1 1 1 INFRARED REMOTE CONTROL UNIT (RMT PN 232-00) FOR USE IN CLASS I AREA ONLY 01-P-FF +PH SENSOR PREAMP (NOTE ) FM APPROVED PREAMP THAT MEETS REQUIREMENTS OF NOTE 3 RECOMMENDED CABLE PN 20023 (UNPREPPED) PN 23-01 PREPPED COND, 2 SHIELDS 2 AWG SEE NOTE 2 +PH SENSOR PREAMP (NOTE ) FM APPROVED PREAMP THAT MEETS REQUIREMENTS OF NOTE 3 PH SENSOR WITH TC RECOMMENDED CABLE WIRES SHIELDED 22 AWG. SEE NOTE 2 SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY OR SUITABILITY FOR DIVISION 2. TB1- WARNING- WARNING- TO PREVENT IGNITION OF FLAMMABLE OR COMBUSTIBLE ATMOSPHERES, DISCONNECT POWER BEFORE SERVICING. UNCLASSIFIED AREA SAFETY BARRIER (SEE NOTES 1 & ) SAFETY BARRIER (SEE NOTES 1 & ) SAFETY BARRIER (SEE NOTES 1 & ) UNSPECIFIED POWER SUPPLY 30 VDC MAX UNSPECIFIED POWER SUPPLY 30 VDC MAX UNSPECIFIED POWER SUPPLY 30 VDC MAX 1 1 2 3 1 1 1 1 2 3 1 1 01-P-FF 01-P-FF SAFETY BARRIER (SEE NOTES 1 & ) UNSPECIFIED POWER SUPPLY 30 VDC MAX 1 1 2 3 1 1 DWG. NO. 0200FvF

instruction Sheet 1a-01p-ff/fi LIQ_MAN_ABR_01P-FF-FI/Rev. D January 201 figure. fm intrinsically Safe installation (2 of 2) DWG. NO. 02000

1a-01p-ff/fi January 201 instruction Sheet LIQ_MAN_ABR_01P-FF-FI/Rev. D figure. csa intrinsically Safe label DWG. NO. 2

instruction Sheet 1a-01p-ff/fi LIQ_MAN_ABR_01P-FF-FI/Rev. D January 201 figure. csa intrinsically Safe installation (1 of 2) FIELDBUS CSA INTRINSIC SAFETY INSTALLATION 01-P-FF HAZARDOUS AREA IS CLASS I, GRPS A-D CLASS II, GRPS E-G CLASS III +PH SENSOR INFRARED RED REMOTE CONTROL UNIT (RMT PN 232-00) FOR USE IN CLASS I AREA ONLY 01-P-FF +PH SENSOR PREAMP (NOTE ) 01-P-FF +PH SENSOR PREAMP (NOTE ) 01-P-FF PH SENSOR WITH TC TB1- WARNING- WARNING- UNSPECIFIED POWER SUPPLY 30 VDC MAX UNSPECIFIED POWER SUPPLY 30 VDC MAX UNSPECIFIED POWER SUPPLY 30 VDC MAX UNSPECIFIED POWER SUPPLY 30 VDC MAX 1 2 3 1 1 1 1 1 2 3 1 1 1 1 2 3 1 1 1 1 2 3 1 1 NI CLASS I, DIV 2 GRPS A-D CLASS II, DIV 2 GRPS E-G CSA APPROVED PREAMP THAT MEETS REQUIREMENTS OF NOTE 3 RECOMMENDED CABLE PN 20023 (UNPREPPED) PN 23-01 PREPPED COND, 2 SHIELDS 2 AWG SEE NOTE 2 CSA APPROVED PREAMP THAT MEETS REQUIREMENTS OF NOTE 3 RECOMMENDED CABLE WIRES SHIELDED 22 AWG. SEE NOTE 2 SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY OR SUITABILITY FOR DIVISION 2. TO PREVENT IGNITION OF FLAMMABLE OR COMBUSTIBLE ATMOSPHERES, DISCONNECT POWER BEFORE SERVICING. UNCLASSIFIED AREA SAFETY BARRIER (SEE NOTES 1 & ) SAFETY BARRIER (SEE NOTES 1 & ) SAFETY BARRIER (SEE NOTES 1 & ) SAFETY BARRIER (SEE NOTES 1 & ) DWG. NO. 0202vE

1a-01p-ff/fi January 201 instruction Sheet LIQ_MAN_ABR_01P-FF-FI/Rev. D figure. csa intrinsically Safe installation (2 of 2). NO REVISION TO DRAWING WITHOUT PRIOR CSA APPROVAL.. THE ASSOCIATED APPARATUS MUST BE CSA APPROVED.. CONTROL EQUIPMENT CONNECTED TO ASSOCIATED APPARATUS MUST NOT USE OR GENERATE MORE THAN 20 Vrms OR Vdc.. ASSOCIATED APPARATUS MANUFACTURER'S INSTALLATION DRAWING MUST BE FOLLOWED WHEN INSTALLING THIS EQUIPMENT.. THE ENTITY CONCEPT ALLOWS INTERCONNECTION OF INTRINSICALLY SAFE APPARATUS WITH ASSOCIATED APPARATUS WHEN THE FOLLOWING IS TRUE: FIELD DEVICE INPUT ASSOCIATED APPARATUS OUTPUT Vmax OR Ui Voc, Vt OR Uo; Imax OR Ii Isc, It OR Io; Pmax OR Pi Po; Ci+ Ccable; Ca, Ct OR Co Li+ Lcable. La, Lt OR Lo. RESISTANCE BETWEEN INTRINSICALLY SAFE GROUND AND EARTH GROUND MUST BE LESS THAN 1.0 Ohm.. DUST-TIGHT CONDUIT SEAL MUST BE USED WHEN INSTALLED IN CLASS II AND CLASS III ENVIRONMENTS.. SENSORS WITHOUT PREAMPS SHALL MEET THE REQUIREMENTS OF SIMPLE APPARATUS AS DEFINED IN ANSI/ISA RP. AND THE CEC (CSA C22.1). THEY CAN NOT GENERATE NOR STORE MORE THAN 1.2V, 0.1A, 2mW, AND 20uJ. SEE TABLES I AND II.. INSTALLATION SHOULD BE IN ACCORDANCE WITH ANSI/ISA RP.0.01 "INSTALLATION OF INTRINSICALLY SAFE SYSTEMS FOR HAZARDOUS (CLASSIFIED) LOCATIONS" AND THE CANADIAN ELECTRICAL CODE (CSA C22.1).. PREAMPLIFIER TYPE 23-00, 233-00, 231-00 OR 002 MAY BE UTILIZED INSTEAD OF THE 01-A-FF TRANSMITTER INTEGRAL PREAMPLIFIER CIRCUIRTY. A WEATHER RESISTANT ENCLOSURE MUST HOUSE THE TYPE 23-00 REMOTE PREAMPLIFIER. 3. INTRINSICALLY SAFE APPARATUS ( 01-A-FF, FIELDBUS TERMINATOR AND ANY ADDITIONAL FIELDBUS DEVICES) AND ASSOCIATED APPARATUS (SAFETY BARRIER) SHALL MEET THE FOLLOWING REQUIREMENTS: THE VOLTAGE (Vmax) AND CURRENT (Imax) OF THE INTRINSICALLY SAFE APPARATUS MUST BE EQUAL TO OR GREATER THAN THE VOLTAGE (Voc OR Vt) AND CURRENT (Isc OR It) WHICH CAN BE DELIVERED BY THE ASSOCIATED APPARATUS (SAFETY BARRIER). IN ADDITION, THE MAXIMUM UNPROTECTED CAPACITANCE (Ci) AND INDUCTANCE (Li) OF THE INTRINSICALLY SAFE APPARATUS, INCLUDING INTERCONNECTING WIRING, MUST BE EQUAL OR LESS THAN THE CAPACITANCE (Ca) AND INDUCTANCE (La) WHICH CAN BE SAFELY CONNECTED TO THE APPARATUS. (REF. TABLE III). 2. THE 01-A-FF TRANSMITTER INCLUDES INTEGRAL PREAMPLIFIER CIRCUITRY. AN EXTERNAL PREAMPLIFIER MAY BE ALSO USED. THE OUTPUT PARAMETERS SPECIFIED IN TABLE II ARE VALID FOR EITHER PREAMPLIFIER. THE CAPACITANCE AND INDUCTANCE OF THE LOAD CONNECTED TO THE SENSOR TERMINALS MUST NOT EXCEED THE VALUES SPECIFIED IN TABLE I WHERE Ca Ci (SENSOR) + Ccable; La Li (SENSOR) + Lcable. 1. ANY SHUNT ZENER DIODE SAFETY BARRIER APPROVED BY CSA HAVING THE FOLLOWING OUTPUT PARAMETERS: SUPPLY/SIGNAL TERMINALS TB1-1, 1 Voc OR Vt NOT GREATER THAN 30 V Isc OR It NOT GREATER THAN 300 ma Pmax NOT GREATER THAN 0. W NOTES: UNLESS OTHERWISE SPECIFIED TABLE I GAS OUTPUT PARAMETERS GROUPS Ca La (uf) (mh) A, B C 0.. 3.1.3 D 21. 2 OUTPUT PARAMETERS Vt It Pt TABLE II 01-P-FF TB1-1 THRU.02 Vdc. ma 1 mw TABLE III 01-P-FF ENTITY PARAMETERS SUPPLY / SIGNAL TERMINALS TB 1-1, 1 NO. Vmax (Vdc) Imax (ma) Pmax (W) Ci (nf) Li (mh) 01-P-FF 30 300 1.3 2. 0 DWG. NO. 0202vE 1

instruction Sheet 1a-01p-ff/fi LIQ_MAN_ABR_01P-FF-FI/Rev. D January 201 figure 1. atex intrinsically Safe label.0 ±.00 O. 2.10 ±.00 2. ±.02. ±.00 2X FULL R..0 ±.01 X R.2 1.30 ±.02 DIRECTION OF NATURAL GRAIN FINISH: SILKSCREEN BLACK EPOXY PAINT (BAKED). 3. ARTWORK IS SUPPLIED BY ROSEMOUNT ANALYTICAL. 2. NO CHANGE WITHOUT BASEEFA APPROVAL. 1 MATERIAL: AISI 300 SERIES STAINLESS STEEL.01 ±.00 THICK. MATERIAL TO BE ANNEALED & PASSIVATED. MAXIMUM HARDNESS BRINELL 10. NOTES: UNLESS OTHERWISE SPECIFIED DWG. NO. 22-00vE 1

1a-01p-ff/fi January 201 instruction Sheet LIQ_MAN_ABR_01P-FF-FI/Rev. D figure 1. fm label Ø. 2X FULL R X R.2 R ROSEMOUNT ANALYTICAL FM 01-P-FI- APPROVED INTRINSICALLY SAFE FOR CLASS I, II & III, DIV. 1, GRPS. A,B,C,D,E,F & G HAZARDOUS AREA WHEN CONNECTED PER DWG. 02 T Tamb= 0 C NON-INCENDIVE CLASS I, DIV. 2, GRPS. A,B,C & D DUST IGNITION PROOF CLASS II AND III, DIV. 1, GRPS. E, F & G WARNING: COMPONENT SUBSTITUTION MAY IMPAIR INTRINSIC SAFETY OR SUITABILITY FOR DIV. 2. NEMA X ENCLOSURE. EXPLOSION PROOF CLASS I, DIV.1, GRPS. B,C & D CLASS II, DIV. 1, GRPS. E,F & G CLASS III, DIV. 1 PER DWG. 02.0 ±.01 2.10 2. ±.02. 23-01/A. 1.30 ±.02 2X.0 ±.01 FINISH:SILKSCREEN BLACK EPOXY PAINT (BAKED). 3. ARTWORK IS SHEET 2 OF 2. 2. NO CHANGE WITHOUT FM APPROVAL. 1 MATERIAL: AISI 300 SERIES STAINLESS STEEL.01+/-.00 THICK. MATERIAL TO BE ANNEALED & PASSIVATED. MAXIMUM HARDNESS BRINELL 10. NOTES: UNLESS OTHERWISE SPECIFIED DWG. NO. 23-01 1

SOL BE 0 0 / B instruction Sheet 1a-01p-ff/fi LIQ_MAN_ABR_01P-FF-FI/Rev. D January 201 figure 1. fm field installation 3 3 USE ONLY APPROVED CONDUIT SEALS AND FITTINGS. 2. SEAL REQUIRED AT EACH CONDUIT ENTRANCE. 1. INSTALLATION MUST CONFORM TO THE NEC. WIRING LABEL 3 POWER SUPPLY 1. VDC MAX 1 2 3 1 1 1 RECOMMENDED SENSORS: 320B 320HP 32A 330B 30 31 31+ 3+ 3 3 3P 3R 3PVP 3RVP 3VP 3 3 3R 3RVP 3VP 3 3VP SAFE AREA RIGID METAL CONDUIT AND APPROVED SEALS ph SENSOR OPTIONAL PREAMP/J-BOX 01-P-FI- HAZARDOUS AREA CLASS I, DIV 1, GPS B-D CLASS II, DIV 1, GPS E-G CLASS III, DIV 1 0 v C MAX RIGID METAL CONDUIT AND APPROVED SEALS SAFE AREA -V +V ANODE/ RESERVED 1 CATHODE/ RESERVED 1 HT/FF (-) 1 HT/FF (+) ph/orp IN ph/orp GUARD GND REF-IN RAT F OR E D RI NG MUS T WI 0 ^C REF- GUARD RTD IN RTD SENSE 3 RTD RTN 2 RESERVED PN 2 1 1-1 RESERVED DWG. NO. 02 1

FISCO INTRINSIC SAFETY INSTALLATION ONE ph SENSOR, OF VARING CONFIGURATIONS, MAY BE ATTACHED HAZARDOUS (CLASSIFIED) LOCATION NON-HAZARDOUS (UNCLASSIFIED) LOCATION OPTIONAL SIMPLE APPARATUS: ph SENSOR 01-P-FI IS CLASS I, II, III, DIVISION 1, GROUPS A, B, C, D, E, F, G 1 2 3 1 1 1 OPTIONAL SIMPLE APPARATUS: ph SENSOR RECOMMENDED CABLE PN 20023 (UNPREPPED) PN 23-01 PREPPED COND, 2 SHIELDS, 2 AWG. SEE NOTE 1 FM APPROVED PREAMP (NOTE 2) OR OR INFRARED REMOTE CONTROL UNIT (RMT PN 232-00) FOR USE IN CLASS I AREA ONLY ANY FM APPROVED TERMINATOR ANY FM APPROVED ASSOCIATED APPARATUS OPTIONAL SIMPLE APPARATUS: ph SENSOR FM APPROVED PREAMP (NOTE 2) OPTIONAL SIMPLE APPARATUS: ph SENSOR WITH TC OR TO PREVENT IGNITION OF FLAMMABLE OR COMBUSTIBLE ATMOSPHERES, DISCONNECT POWER BEFORE SERVICING. ANY FM APPROVED INTRINSICALLY SAFE APPARATUS RECOMMENDED CABLE WIRES SHIELDED, 22 AWG, SEE NOTE 1 ANY FM APPROVED TERMINATOR FIELDBUS (NON-FISCO) INTRINSIC SAFETY INSTALLATION HAZARDOUS (CLASSIFIED) LOCATION NON-HAZARDOUS (UNCLASSIFIED) LOCATION IS CLASS I, II, III, ONE ph SENSOR, OF VARING CONFIGURATIONS, MAY BE ATTACHED DIVISION 1, THIS DOCUMENT IS GROUPS A, B, C, D, E, F, G CERTIFIED BY OPTIONAL SIMPLE APPARATUS: ph SENSOR 1 2 3 1 1 1 OPTIONAL SIMPLE APPARATUS: ph SENSOR RECOMMENDED CABLE PN 20023 (UNPREPPED) PN 23-01 PREPPED COND, 2 SHIELDS, 2 AWG. SEE NOTE 1 FM APPROVED PREAMP (NOTE 2) OR OR INFRARED REMOTE CONTROL UNIT (RMT PN 232-00) FOR USE IN CLASS I AREA ONLY 01-P-FI SAFETY BARRIER (SEE NOTE ) UNSPECIFIED POWER SUPPLY 30 VDC MAX FM REV B REV REV REV REV REV REVISIONS NOT PERMITTED W/O AGENCY APPROVAL OPTIONAL SIMPLE APPARATUS: ph SENSOR FM APPROVED PREAMP (NOTE 2) OPTIONAL SIMPLE APPARATUS: ph SENSOR WITH TC WARNING- TB1- OR WARNING- TB1- TO PREVENT IGNITION OF FLAMMABLE OR COMBUSTIBLE ATMOSPHERES, DISCONNECT POWER BEFORE SERVICING. RECOMMENDED CABLE WIRES SHIELDED, 22 AWG, SEE NOTE 1 1a-01p-ff/fi January 201 instruction Sheet LIQ_MAN_ABR_01P-FF-FI/Rev. D figure 1. fisco and fieldbus intrinsically Safe installation DWG. NO. 02vC 1

instruction Sheet 1a-01p-ff/fi LIQ_MAN_ABR_01P-FF-FI/Rev. D January 201 figure 1. division 2 nonincendive field wiring installation 1 NON-INCENDIVE FIELD WIRING METHODS MAY BE USED FOR CONNECTING SENSORS TO THE INSTRUMENT. ATTACHED SENSORS MUST BE FM APPROVED AS NON-INCENDIVE FOR CLASS 1, DIVISION 2, GROUPS ABCD WITH INPUT VALUES OF Vmax AND Imax > Voc (Vt) AND Isc (It) LISTED IN TABLE II AND THE Ci AND Li OF THE SENSOR AND INTERCONNECTED WIRING MUST BE < Ca AND La LISTED IN TABLE 1 OR BE CLASSIFIED AS "SIMPLE APPARATUS". SIMPLE APPARATUS ARE DEVICES WHICH ARE INCAPABLE OF GENERATING OR STORING MORE THAN 1.2 V, 0.1 A, 2 mw OR 20 µj (CONTACTING CONDUCTIVITY SENSORS QUALIFY AS SIMPLE APPARATUS). 1 INSTALATION TO BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE. 1 DIVISION 2 WIRING METHOD PER THE NEC (EXCLUDING NONINCENDIVE FIELD WIRING). INTRINSICALLY SAFE APPARATUS ( 01-P-FI, FIELDBUS TERMINATOR AND ANY ADDITIONAL FIELDBUS DEVICES) AND ASSOCIATED APPARATUS (SAFETY BARRIER) SHALL MEET THE FOLLOWING REQUIREMENTS: THE VOLTAGE (Vmax) AND CURRENT (Imax) OF THE INTRINSICALLY SAFE APPARATUS MUST BE EQUAL TO OR GREATER THAN THE VOLTAGE (Voc OR Vt) AND CURRENT (Isc OR It) WHICH CAN BE DELIVERED BY THE ASSOCIATED APPARATUS (SAFETY BARRIER). IN ADDITION, THE MAXIMUM UNPROTECTED CAPACITANCE (Ci) AND INDUCTANCE (Li) OF THE INTRINSICALLY SAFE APPARATUS, INCLUDING INTERCONNECTING WIRING, MUST BE EQUAL OR LESS THAN THE CAPACITANCE (Ca) AND INDUCTANCE (La) WHICH CAN BE SAFELY TO THE APPARATUS. (REF. TABLE IV). 1 1 1 ANY SHUNT ZENER DIODE SAFETY BARRIER APPROVED BY FM HAVING THE FOLLOWING OUTPUT PARAMETERS: SUPPLY/SUGNAL TERMINALS TB1-1, 1 Voc OR Vt NOT GREATER THAN 30 V Isc OR It NOT GREATER THAN 300 ma Pmax NOT GREATER THAN 0. W. NO REVISION TO DRAWING WITHOUT PRIOR FM APPROVAL.. THE CONFIGURATION OF ASSOCIATED APPARATUS MUST BE FM APPROVED UNDER THE ASSOCIATED CONCEPT.. CONTROL EQUIPMENT CONNECTED TO ASSOCIATED APPARATUS MUST NOT USE OR GENERATE MORE THAN 20 Vrms OR Vdc.. ASSOCIATED APPARATUS MANUFACTURER'S INSTALLATION DRAWING MUST BE FOLLOWED WHEN INSTALLING THIS EQUIPMENT. ONE ph SENSOR, OF VARING CONFIGURATIONS, MAY BE ATTACHED OPTIONAL SIMPLE APPARATUS: ph SENSOR OPTIONAL SIMPLE APPARATUS: ph SENSOR RECOMMENDED CABLE PN 20023 (UNPREPPED) PN 23-01 PREPPED COND, 2 SHIELDS, 2 AWG. SEE NOTE 1 OPTIONAL SIMPLE APPARATUS: ph SENSOR 1 2 3 OPTIONAL SIMPLE APPARATUS: ph SENSOR WITH TC FM APPROVAL PREAMP (NOTE 2) FM APPROVAL PREAMP (NOTE 2) RECOMMENDED CABLE WIRES SHIELDED, 22 AWG, SEE NOTE 1 OR OR OR 1 1 NON-INCENDIVE FIELD WIRING CONNECTIONS FOR CLASS 1, DIVISION 2, GROUPS ABCD 01-P-FI DIVISION 2 HAZARDOUS AREA NI CLASS I, DIVISION 2, GROUPS A,B,C,D; SUITABLE CLASS II, DIVISION 2, GROUPS F & G; SUITABLE CLASS III, DIVISION 2 1 1 UNCLASSIFIED AREA. THE ENTITY CONCEPT ALLOWS INTERCONNECTION OF INTRINSICALLY SAFE APPARATUS WITH ASSOCIATED APPARATUS WHEN THE FOLLOWING IS TRUE: FIELD DEVICE INPUT ASSOCIATED APPARATUS OUTPUT Vmax OR Ui > Voc, Vt OR Uo Imax OR Ii > Isc, It OR Io Pmax OR Pi > Po 3Ci+ 3Ccable < Ca, Ct OR Co (FOR FISCO INSTALLATIONS) 3Li+ 3Lcable. < La, Lt OR Lo; OR Lc/Rc < (La/Ra OR Lo/Ro) AND Li/Ri < (La/Ra OR Lo/Ro) (FOR FISCO INSTALLATIONS) Ci+ Ccable < Ca, Ct OR Co (FOR FIELDBUS (NON-FISCO) INSTALLATIONS) Li+ Lcable. < La, Lt OR Lo (FOR FIELDBUS (NON-FISCO) INSTALLATIONS). RESISTANCE BETWEEN INTRINSICALLY SAFE GROUND AND EARTH GROUND MUST BE LESS THAN 1.0 Ohm.. DUST-TIGHT CONDUIT SEAL MUST BE USED WHEN INSTALLED IN CLASS II AND CLASS III ENVIRONMENTS.. SENSORS WITHOUT PREAMPS SHALL MEET THE REQUIREMENTS OF SIMPLE APPARATUS AS DEFINED IN ANSI/ISA RP. AND THE NEC, ANSI/NFPA 0. THEY CAN NOT GENERATE NOR STORE MORE THAN 1.V, 0.1A, 2mW OR A PASSIVE COMPONENT THAT DOES NOT DISSIPATE MORE THAN 1.3W. SEE TABLES I AND II. 3. INSTALLATION SHOULD BE IN ACCORDANCE WITH ANSI/ISA RP.0 "INSTALLATION OF INTRINSICALLY SAFE SYSTEMS FOR HAZARDOUS (CLASSIFIED) LOCATIONS" (EXCEPT CHAPTER FOR FISCO INSTALLATIONS) AND THE NATIONAL ELECTRICAL CODE (ANSI/NFPA 0) SECTIONS 0 AND 0. 2. PREAMPLIFIER TYPE 23-00, 233-00 OR 231-00 MAY BE UTILIZED INSTEAD OF THE 01-A-FI TRANSMITTER INTEGRAL PREAMPLIFIER CIRCUIRTY. A WEATHER RESISTANT ENCLOSURE MUST HOUSE THE TYPE 23-00 REMOTE PREAMPLIFIER. OTHER PREAMPS OR PREAMP CONTAINING SENSORS MAY BE USED IF OVERALL C AND L ARE LESS THAN THE LIMITS DETAILED IN NOTE 1 AND THE MAXIMUM ENTITY PARAMETERS ARE GREATER THAN THOSE LISTED IN TABLE II. 1. THE 01-P-FI TRANSMITTER INCLUDES INTEGRAL PREAMPLIFIER CIRCUITRY. AN EXTERNAL PREAMPLIFIER MAY BE ALSO USED. THE OUTPUT PARAMETERS SPECIFIED IN TABLE II ARE VALID FOR EITHER PREAMPLIFIER. THE CAPACITANCE AND INDUCTANCE OF THE LOAD CONNECTED TO THE SENSOR TERMINALS MUST NOT EXCEED THE VALUES SPECIFIED IN TABLE I WHERE Ca > Ci (SENSOR) + Ccable La > Li (SENSOR) + Lcable. GAS GROUPS A, B 0.. C D OUTPUT PARAMETERS Vt It TABLE II WARNING- WARNING- TABLE I OUTPUT PARAMETERS Ca (µf) 01-P-FI TB1-1 THRU.02 Vdc. ma Pt 1 mw 3.1.3 La (mh) 21. 2 SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY OR SUITABILITY FOR DIVISION 2. TO PREVENT IGNITION OF FLAMMABLE OR COMBUSTIBLE ATMOSPHERES, DISCONNECT POWER BEFORE SERVICING. GROUPS IIB/ C,D,E,F,G IIC/ A,B,C,D,E,F,G TABLE III 01-P-FI FISCO ENTITY PARAMETERS SUPPLY / SIGNAL TERMINALS TB1-1, 1 Vmax (Vdc) Imax (ma) Pmax (W) Ci (nf) Li (µh) 1. 30.32 1. 30 2.2 TABLE IV 01-P-FI FIELDBUS (NON-FISCO) ENTITY PARAMETERS SUPPLY / SIGNAL TERMINALS TB1-1, 1 Vmax (Vdc) Imax (ma) Pmax (W) Ci (nf) Li (µh) 30 300 1.3 2. 0 DWG. NO. 02vC 1

1a-01p-ff/fi January 201 instruction Sheet LIQ_MAN_ABR_01P-FF-FI/Rev. D figure 1. csa label Ø. X R.2.0 ±.01 2X FULL R. ±.00 R ROSEMOUNT ANALYTICAL R SA LR31 01-P-FI- ENCLOSURE Exia ENTITY INTRINSICALLY SAFE FOR CLASS I, GRPS A, B, C & D CLASS II, GRPS E, F & G CLASS III T Tamb = 0 C HAZARDOUS AREA WHEN CONNECTED PER DWG. 02 WARNING: COMPONENT SUBSTITUTION MAY IMPAIR INTRINSIC SAFETY. CLASS I, DIV. 2, GRPS A,B,C & D SUITABLE FOR CLASS II, DIV. 2, GRPS E, F & G T Tamb= 0 C WARNING-EXPLOSION HAZARD-DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS AREA IS KNOWN TO BE NON- HAZARDOUS. WARNING-EXPLOSION HAZARD-SUBSTITU- TION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIV 2. CLASS I, GRPS B,C & D CLASS II, GRPS E, F & G CLASS III Tamb = C MAX Tamb ABOVE 0 C USE C MINIMUM RATED WIRING SEAL REQUIRED TO BE INSTALLED WITHIN 0 mm OF THE ENCLOSURE. KEEP COVER TIGHT WHILE CIRCUITS ARE LIVE. 2-01/A 2.10 ±.00 2. ±.02..0 ±.01 1.30 ±.02 3. ARTWORK IS SHEET 2 OF 2. 2. NO CHANGE WITHOUT CSA APPROVAL. 1 MATERIAL: AISI 300 SERIES STAINLESS STEEL.01+/-.00 THICK. MATERIAL TO BE ANNEALED & PASSIVATED. MAXIMUM HARDNESS BRINELL 10. NOTES: UNLESS OTHERWISE SPECIFIED DWG. NO. 23-01 20

instruction Sheet 1a-01p-ff/fi LIQ_MAN_ABR_01P-FF-FI/Rev. D January 201 figure 20. fisco csa intrinsically Safe installation FISCO CSA INTRINSIC SAFETY INSTALLATION 01-P-FI HAZARDOUS AREA IS CLASS I, GRPS A-D CLASS II, GRPS E-G CLASS III +PH SENSOR INFRARED RED REMOTE CONTROL UNIT (RMT PN 232-00) FOR USE IN CLASS I AREA ONLY 01-P-FI +PH SENSOR PREAMP (NOTE 3) 01-P-FI +PH SENSOR PREAMP (NOTE 3) 01-P-FI PH SENSOR WITH TC TB1- WARNING- WARNING- UNSPECIFIED POWER SUPPLY 1. VDC MAX 1 2 3 1 1 1 1 1 2 3 1 1 1 1 2 3 1 1 1 1 2 3 1 1 NI CLASS I, DIV 2 GRPS A-D CLASS II, DIV 2 GRPS E-G CSA APPROVED PREAMP THAT MEETS REQUIREMENTS OF NOTE 2 RECOMMENDED CABLE PN 20023 (UNPREPPED) PN 23-01 PREPPED COND, 2 SHIELDS 2 AWG SEE NOTE 1 CSA APPROVED PREAMP THAT MEETS REQUIREMENTS OF NOTE 2 RECOMMENDED CABLE WIRES SHIELDED 22 AWG. SEE NOTE 1 SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY OR SUITABILITY FOR DIVISION 2. TO PREVENT IGNITION OF FLAMMABLE OR COMBUSTIBLE ATMOSPHERES, DISCONNECT POWER BEFORE SERVICING. UNCLASSIFIED AREA CSA APPROVED ASSOCIATED APPARATUS SUITABLE FOR FISCO SEE NOTE AND TABLE III CSA APPROVED ASSOCIATED APPARATUS SUITABLE FOR FISCO SEE NOTE AND TABLE III CSA APPROVED ASSOCIATED APPARATUS SUITABLE FOR FISCO SEE NOTE AND TABLE III CSA APPROVED ASSOCIATED APPARATUS SUITABLE FOR FISCO SEE NOTE AND TABLE III UNSPECIFIED POWER SUPPLY 1. VDC MAX UNSPECIFIED POWER SUPPLY 1. VDC MAX UNSPECIFIED POWER SUPPLY 1. VDC MAX DWG. NO. 02vB 21

1a-01p-ff/fi January 201 instruction Sheet LIQ_MAN_ABR_01P-FF-FI/Rev. D figure 21. fisco csa intrinsically Safe installation. NO REVISION TO DRAWING WITHOUT PRIOR CSA APPROVAL.. THE ASSOCIATED APPARATUS MUST BE CSA APPROVED.. CONTROL EQUIPMENT CONNECTED TO ASSOCIATED APPARATUS MUST NOT USE OR GENERATE MORE THAN 20 Vrms OR Vdc.. ASSOCIATED APPARATUS MANUFACTURER'S INSTALLATION DRAWING MUST BE FOLLOWED WHEN INSTALLING THIS EQUIPMENT.. THE ENTITY CONCEPT ALLOWS INTERCONNECTION OF INTRINSICALLY SAFE APPARATUS WITH ASSOCIATED APPARATUS WHEN THE FOLLOWING IS TRUE: FIELD DEVICE INPUT ASSOCIATED APPARATUS OUTPUT Vmax OR Ui Voc, Vt OR Uo; Imax OR Ii Isc, It OR Io; Pmax OR Pi Po; Ci+ Ccable; Ca, Ct OR Co Li+ Lcable. La, Lt OR Lo. RESISTANCE BETWEEN INTRINSICALLY SAFE GROUND AND EARTH GROUND MUST BE LESS THAN 1.0 Ohm.. DUST-TIGHT CONDUIT SEAL MUST BE USED WHEN INSTALLED IN CLASS II AND CLASSIII ENVIRONMENTS.. SENSORS WITHOUT PREAMPS SHALL MEET THE REQUIREMENTS OF SIMPLE APPARATUS AS DEFINED IN ANSI/ISA RP. AND THE CEC (CSA C22.1). THEY CAN NOT GENERATE NOR STORE MORE THAN 1.V, 0.1A, 2mW, AND 20uJ. SEE TABLES I AND II.. INSTALLATION SHOULD BE IN ACCORDANCE WITH ANSI/ISA RP.0.01 "INSTALLATION OF INTRINSICALLY SAFE SYSTEMS FOR HAZARDOUS (CLASSIFIED) LOCATIONS" AND THE CANADIAN ELECTRICAL CODE (CSA C22.1). 3. PREAMPLIFIER TYPE 23-00, 233-00, 231-00 OR 002 MAY BE UTILIZED INSTEAD OF THE 01-A-FI TRANSMITTER INTEGRAL PREAMPLIFIER CIRCUIRTY. A WEATHER RESISTANT ENCLOSURE MUST HOUSE THE TYPE 23-00 REMOTE PREAMPLIFIER. 2. INTRINSICALLY SAFE APPARATUS ( 01-A-FI, FIELDBUS TERMINATOR AND ANY ADDITIONAL FIELDBUS DEVICES) AND ASSOCIATED APPARATUS (SAFETY BARRIER) SHALL MEET THE FOLLOWING REQUIREMENTS: THE VOLTAGE (Vmax) AND CURRENT (Imax) OF THE INTRINSICALLY SAFE APPARATUS MUST BE EQUAL TO OR GREATER THAN THE VOLTAGE (Voc OR Vt) AND CURRENT (Isc OR It) WHICH CAN BE DELIVERED BY THE ASSOCIATED APPARATUS (SAFETY BARRIER). IN ADDITION, THE MAXIMUM UNPROTECTED CAPACITANCE (Ci) AND INDUCTANCE (Li) OF THE INTRINSICALLY SAFE APPARATUS, INCLUDING INTERCONNECTING WIRING, MUST BE EQUAL OR LESS THAN THE CAPACITANCE (Ca) AND INDUCTANCE (La) WHICH CAN BE SAFELY CONNECTED TO THE APPARATUS. (REF. TABLE III). 1. THE 01-A-FI TRANSMITTER INCLUDES INTEGRAL PREAMPLIFIER CIRCUITRY. AN EXTERNAL PREAMPLIFIER MAY BE ALSO USED. THE OUTPUT PARAMETERS SPECIFIED IN TABLE II ARE VALID FOR EITHER PREAMPLIFIER. THE CAPACITANCE AND INDUCTANCE OF THE LOAD CONNECTED TO THE SENSOR TERMINALS MUST NOT EXCEED THE VALUES SPECIFIED IN TABLE I WHERE Ca Ci (SENSOR) + Ccable; La Li (SENSOR) + Lcable. NOTES: UNLESS OTHERWISE SPECIFIED TABLE I GAS OUTPUT PARAMETERS GROUPS Ca La (uf) (mh) A, B C 0.. 3.1.3 D 21. 2 OUTPUT PARAMETERS Vt It Pt TABLE II 01-P-FF TB1-1 THRU.02 Vdc. ma 1 mw TABLE III 01-P-FI ENTITY PARAMETERS SUPPLY / SIGNAL TERMINALS TB 1-1, 1 NO. Vmax (Vdc) Imax (ma) Pmax (W) Ci (nf) Li (mh) 01-P-FI 1. 30.32 2. 0 DWG. NO. 02vB 22

instruction Sheet 1a-01p-ff/fi LIQ_MAN_ABR_01P-FF-FI/Rev. D January 201 figure 22. atex/iece label.0 ±.00 O. 2.10 ±.00 2. ±.02. ±.00 2X FULL R..0 ±.01 X R.2 1.30 ±.02 DIRECTION OF NATURAL GRAIN FINISH: SILKSCREEN BLACK EPOXY PAINT (BAKED). 3. ARTWORK IS SUPPLIED BY ROSEMOUNT ANALYTICAL. 2. NO CHANGE WITHOUT BASEEFA APPROVAL. 1 MATERIAL: AISI 300 SERIES STAINLESS STEEL.01 ±.00 THICK. MATERIAL TO BE ANNEALED & PASSIVATED. MAXIMUM HARDNESS BRINELL 10. NOTES: UNLESS OTHERWISE SPECIFIED DWG. NO. 22-01vB 23

1a-01p-ff/fi January 201 instruction Sheet LIQ_MAN_ABR_01P-FF-FI/Rev. D infrared remote controller (irc) Key functions The infrared remote controller is used to calibrate and program the transmitter and to display diagnostic messages. See figure below for a description of the function of the keys. Hold the IRC within feet of the transmitter, and not more than 1 degrees from the center of the display window. figure 23. infrared remote controller reset - Press RESET to end the current operation and return to the main display. Changes will NOT be saved. reset does not return the transmitter to factory default settings. arrow KeyS - Use é and ê keys to increase or decrease a number or to scroll through items in a list. Use the ç or è keys to move the cursor across a number. A flashing word or numeral shows the position of the cursor. cal - Press CAL to access the calibration menu. prog - Press PROG to access the program menu. Hold - Press HOLD to access the prompts used for turning on or off the hold function. enter - Press ENTER to move from a submenu to the first prompt under the submenu. Pressing ENTER also stores changes in memory and advances to the next prompt. next - Press NEXT to advance to the next submenu or to leave a message screen. exit - Press EXIT to end the current operation. Changes are NOT saved. diag - Press DIAG to read diagnostic messages. 2

instruction Sheet 1a-01p-ff/fi LIQ_MAN_ABR_01P-FF-FI/Rev. D January 201 STarT-up configuration and calibration ph The 20 ma output is factory set to 0-1 ph. To change it, follow these steps: 1. Press PROG, ENTER. 2. Use the arrow buttons to enter the ma value. Press ENTER. 3. Use the arrow buttons to enter the 20 ma value. Press ENTER.. Press RESET. To perform a two-point buffer calibration, follow these steps: 1. Place the ph sensor in the first buffer solution. 2. On the remote, press CAL, ENTER, ENTER. 3. Use the arrow buttons to select the correct buffer value. Press ENTER.. Rinse the sensor and place it in the second buffer solution. Press ENTER.. Use the arrow buttons to select the correct buffer value. Press ENTER. figure 2. Menu Tree for ph CALIbRATE PROgRAM DIAgNOSE CALIbrAtE Std temp AdJ cal bf1 Std.00 temp 2.0 InPut. SLOPE OFFSt gimp 00 rimp 01-P-FF SoFt HArd FAULtS bf 1 SlOPe.01 none bf1.01 cal bf2 bf 2 bf2.01 diagnostic temp display buffer ISOPOtntAL LinE FrEq PAMP=trAnS roffst 00 diag OFF ImPtc ON tauto On tman 2.0 type PH temp c OUtPUt cur bauto On buffer Std StAbiliSe tcoef 00.00 ISO 0.00 Snr 0.00 line 0 NO default FActOrY YeS GFH 0 code 000 time GWH 00 GWl 020 GFl 0 cal 000 ref lo rfh rwh 00 delta 00.02 MENU Sub-menu PROmPT Diag message rwl 000 rfl 000 2

1a-01p-ff/fi January 201 instruction Sheet LIQ_MAN_ABR_01P-FF-FI/Rev. D STarT-up configuration and calibration orp To perform a one point standardization, follow these steps. 1. Place the ORP sensor in the ORP buffer solution. 2. On the Remote press CAL, ENTER, ENTER 3. Use the arrow buttons to adjust the value. Press ENTER. Press RESET figure 2. Menu Tree for orp MENU Sub-menu PROmPT Diag message 2

instruction Sheet 1a-01p-ff/fi LIQ_MAN_ABR_01P-FF-FI/Rev. D January 201 Table 1. program Menu Mnemonics 01-p display Manual TexT Meaning CALIbrAtE CALIbrAtE Calibration menu Std Std Standardize sensor bf1 / bf2 bf1 / bf2 Buffer 1 / Buffer 2 SLOPE SLOPE Sensor slope Hold HoLd Set hold FAULt FAULt Set fault dpn dpn Set output dampening diagnostic diagnostic Diagnostic submenu roffst roffst Reference offset IMPtC IMPtC Glass impedance temperature compensation GFH GFH Glass fault high GWJH GWH Glass warning high GFL GFL Glass fault low GWJL GWL Glass warning low CAL CAL [Factory use only] ref ref Set high/low impedance reference rfh rfh Reference fault high rwjh rwh Reference warning high rfl rfl Reference fault low rwjl rwl Reference warning low temp temp Temperature units tauto tauto Automatic temperature compensation tman tman Manual temperature compensation type type Measurement type (ph/orp) display display Display submenu 2

LIQ_MAN_ABR_01P-FF-FI Rev. D January 201 facebook.com/emersonrosemountanalytical AnalyticExpert.com twitter.com/raihome youtube.com/user/rosemountanalytical Credit Cards for U.S. Purchases Only. emerson process Management 200 Barranca Parkway Irvine, CA 20 USA Tel: () -00 Fax: () -20 rosemountanalytical.com Rosemount Analytical Inc. 201 201 Rosemount Analytical, Inc. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. Brand name is a mark of one of the Emerson Process Management family of companies. All other marks are the property of their respective owners. The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.