TOSVERT VF-AS1 PID control Instruction Manual

Similar documents
6.9 Jump frequency - Avoiding frequency resonance

TOSVERT VF-AS1 My Function Instruction Manual

TOSVERT TM VF-nC3 Parameter List

TOSVERT VF-AS1 E Parameter List (V154)

Before you operate the inverter, the parameters that you must first program are the basic parameters.

VFS11 Parameter List for up to CPU version 105

TOSVERT VF-PS1 E Parameter List (V654)

Multi-function, Compact Inverters. 3G3MV Series

PID-CONTROL FUNCTION AND APPLICATION

[ 4 ] Using pulse train input (F01 = 12)

TOSVERT VF-AS1 Option Function Manual CCL001Z

MA7200 PLUS INVERTER SERIES PID Quick Start Manual For Fan and Pump Applications

VFS9 Parameter List for Version110 or later

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class

S11 Adjustable Speed Drive Engineering Specification

OPC-E1-PG3 Specifications

V&T Technologies Co., Ltd. Vectorque TM V6-H-M1 SERIES INVERTER ADDITIVE MANUAL (M1) V6-H Series ADDITIVE MANUAL V& T

ROLL TO ROLL FUNCTION MANUAL FR-A (0.4K)-04750(90K)-R2R FR-A (0.4K)-06830(280K)-R2R FR-A (315K)-12120(500K)-R2R

CHAPTER 8 PARAMETER SUMMARY

ADJUSTABLE SPEED DRIVES FS1

Optidrive Applications Support Library

E3 Adjustable Speed Drive Engineering Specification

QUICK GUIDE PUMP CONTROL. High performance Compact Inverter. Date Version 22/09/

Enhanced PID for Air Compressors F7 Drive Software Technical Manual

VF-nC1 Adjustable Speed Drive Engineering Specification

SJ100 Series Inverter Quick Reference Guide. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class

ADJUSTABLE SPEED DRIVES. AS1 Drive

INTERNATIONAL SERVICE BULLETIN - I #2-319 Liberty - Delta M+ VFD parameter list. A VFD parameter list is required when replacing a DELTA M+ VFD.

AZ Series. Function Edition. Closed Loop Stepping Motor and Driver Package. Operation. I/O signals. Parameter

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6

MITOS VT6 AIR USER MANUAL. 02/10/2015 Manual_MITOS_VT6_AIR_ver3p3_eng

Operating Instructions

CHAPTER 8 SUMMARY OF PARAMETER SETTINGS

FUJI Inverter. Standard Specifications

VA TECH ELIN EBG Elektronik. Operating and Mounting instructions. >pdrive< CX profi. The Power Drives Company

Application Note CTAN #287

NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives

Appendix F: PID Control...F 1 PID Control...F 2

Hitachi P1 Closed Loop Hoist Basic Instruc on Manual

Fan and Pump AC Inverter

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

Optional add-on cassette Vector-option unit Instruction manual

Experiment 9. PID Controller

Configuring Drive Parameters

About this Manual: Chapter 1 provides a summary of the Servo System and all gains used for the Servo System loops.

GS1 Parameter Summary Detailed Parameter Listings...4 9

L100-M Series Inverters

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS

Dual-inverter Wire Drawing Machine CHV130 series Frequency inverter Operation manual

efesotomasyon.com -Toshiba inverter,drive,servo,plc TOSVERT VF-AS1/PS1 * The data given in this manual are subject to change without notice.

Closed-Loop Position Control, Proportional Mode

User s Manual. Model US1000 Digital Indicating Controller Functions. IM 5D1A01-02E 2nd Edition IM 5D1A01-02E

No. MXDP Indexer Application Software Model: 3G3MX2 CX-Drive Version QUICK START GUIDE

Generator Speed Controller Model GSC 1

1. INTRODUCTION Fire Mode PID Application Parameter lists DESCRIPTION OF PARAMETERS... 8

The GS1 Digital Keypad LED Display Function Keys Displaying the Status of the GS1 AC Drive Programming the GS1 AC Drive...

The new Yaskawa Varispeed G7 Inverter

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

QUICK GUIDE SINGLE PUMP CONTROL. Frequency inverter for pump control applications SG_PUMP_CONTROL_HVAC_EN_1.1.0

MD310 Quick Start Manual. General-Purpose AC Drive

user's manual nx frequency converters beam pump application asfiff13

Application Note: Replacing J300 with SJ300 Series Inverters

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

VS-616G5 Series (Revision F) Programming Manual. Constant Torque Inverter with Adaptive Vector Control (AVC )

HITACHI INVERTER SJ700-2 SERIES SERVICE MANUAL. After reading this manual, keep it handy for future reference. NTS204X

SJ700-2 SERIES HITACHI INVERTER SERVICE MANUAL. Phone: Fax: Web: -

HPVFP High Performance Full Function Vector Frequency Inverter

ADTECH Solar inverter

(Supplement to Instruction Manual)

Automate. Hardware: Software: 1. Somove Lite V (or latest version available) for drive configuration optional

AV-300i Specifications. Saftronics Inc. PC10 Product Specifications PC10. Mini Vector AC Drive

ADJUSTABLE SPEED DRIVES VF-S11 Sords Electric

Manual Overview...1 2

13. Before making a service call Trip information and remedies

vacon nx all in one application manual ac drives Phone: Fax: Web: -

PSF-520 Instruction Manual

NX Series Inverters. HVAC Pocket Programming Guide

FRENIC MEGA in Injection Moulding Machine s applications

>pdrive< CX single >pdrive< CX compact

NX series Constant and variable torque Variable Speed Drives for induction motors

Application sheet for Green 300 series controllers. Title. Purpose. Application Controller Loop Configuration: Wiring: Explanation :

Instruction Manual D

SV9000 SVReady USER MANUAL CONTENTS OPEN SV9000 USER MANUAL. SV9000 Page 0-1

Closed Loop Stepping System with Network based Motion Controller

Copyright / Trademarks -This manual and its contents are copyrighted. -You may not copy this manual,in whole or part,without written consent of

AV-300i Specifications. Saftronics Inc. VG10 Product Specifications VG10. Dynamic Vector Drive

G320X MANUAL DC BRUSH SERVO MOTOR DRIVE

Inverter Drive /Vector Drive Motors & Controls

Compact & Powerful Inverter STARVERT ig5a 0.4~1.5kW 1phase 200~230Volts 0.4~22kW 3Phase 200~230Volts 0.4~22kW 3Phase 380~480Volts

Programming and Operation Manual

Configuration Example of Temperature Control

α α Retry count clear Alarm reset Active End of retry S-curve time during accelerati on H04: (Count) setting S curve time during decelerati on

Think About Control Fundamentals Training. Terminology Control. Eko Harsono Control Fundamental - Con't

Pump / compressor Duty Cycle control function with FRENIC MEGA

USE OF INVERTERS WITH COPELAND STREAM COMPRESSORS

Drive System Application

Transcription:

TOSVERT VF-AS1 PID control Instruction Manual The technical information in this manual is provided to explain the principal functions and applications of the product, but not to grant you a license to use the intellectual property or any other property of Toshiba Schneider Inverter Corporation or a third party. Toshiba Schneider Inverter Corporation 2005 All rights reserved.

CONTENTS 1. PID CONTROL FUNCTION... 2 1.1. PID control block diagram... 2 1.2. Parameters for PID control function... 3 1.2.1. Parameters for PID control function... 3 1.2.2. Maximum frequency... 5 1.2.3. Upper limit frequency... 5 1.2.4. Specifying the feedback value... 5 1.2.5. Specifying the process value... 7 1.2.6. Acceleration/deceleration time... 9 1.2.7. Upper limit frequency, lower limit frequency and jump frequency... 9 1.2.8. Override processing... 9 1.2.9. Operation starting frequency... 9 1.2.10. Switching to open loop operation... 9 1.2.11. Resetting the integral gain and differential gain set for PID control... 10 2. ADJUSTING PID CONTROL GAINS... 11 2.1.1. Adjusting the proportional (P) gain... 11 2.1.2. Adjusting the integral (I) gain... 12 2.1.3. Adjusting the differential (D) gain... 12 2.1.4. Adjusting the delay filter... 12 2.1.5. Adjusting the PID deviation upper limit... 12 2.1.6. Adjusting the PID deviation lower limit... 13 2.1.7. Adjusting the target upper limit... 13 2.1.8. Adjusting the target lower limit... 13 2.1.9. Adjusting the PID start waiting time... 13 2.1.10. Adjusting the PID output upper limit... 13 2.1.11. Adjusting the PID output lower limit... 13 2.1.12. Adjusting the increase and decrease rates of the target value... 14 2.1.13. Converting the units of the process value and feedback value... 14 2.2. Adjusting the analog command voltage... 15 1

1. PID control function E6581329 The VF-AS1 has two types of PID control functions. By setting parameters, a type of PID control can be selected between process PID control which is performed gently in response to changes in temperature or pressure and speed PID control, such as speed control of a winder, which is performed at high speed in response to changes in speed. 1.1. PID control block diagram Here are block diagram showing the outline of PID control. [Process PID control (f359=1)] Process value Process upper limit f367 Process lower limit f368 - PID deviation upper limit (f364) PID deviation lower limit f365 PID control PID output upper limit f370 PID output lower limit f371 Jump frequency processing Output frequency upper limit ( ul) (acc,dec) Increase/ decrease rate Output frequency lower limit ll Feedback value [Speed PID control (f359=2)] Process upper limit (f367) Process value Process lower limit (f368) Feedback value (f372, PID deviation upper limit f373 ) PID output upper limit (f364) (f370) Increase/ decrase rate PID control Delay filter (f361) - PID deviation lower limit (f365) PID output lower limit (f371) Jump frequency processing Output frequency upper limit (ul) Output frequency lower limit (ll) 2

1.2. Parameters for PID control function 1.2.1. Parameters for PID control function The table below lists the parameters that need to be set for PID control. Title Function Adjustment range fmod Frequency setting mode selection 1 1: VI/II (voltage/current input) 2: RR/S4 (potentiometer/voltage input) 3: RX (voltage input) 4: Operation panel input enabled (including LED/LCD panel option input) 5: Operation panel RS485 (2-wire) communications input 6: Internal RS485 (4-wire) communications input 7: Communications option input 8: Option AI1 (differential current input) 9: Option AI2 (voltage/current input) 10: UP/DOWN frequency 11: RP pulse input 12: High-speed pulse input 13: Binary/BCD input Default setting 2 fh Maximum frequency 30.0~500.0 (Hz) 80.0 ul Upper limit frequency 0.0~fh (Hz) 60.0 ll Lower limit frequency 0.0~ul (Hz) 0.0 acc Acceleration time 1 0.1~6000 (sec.) Depends on the capacity dec Deceleration time 1 0.1~6000 (sec.) Depends on the capacity f207 Frequency setting mode Same as fmod (1~13) 1 selection 2 f240 Operation starting frequency 0.0~fh (Hz) 0.1 f241 Operation starting frequency 0.0~30.0 (Hz) 0.0 hysteresis f270 Jump frequency 1 0.0~fh (Hz) 0.0 f271 Jump step 1 0.0~30.0 Hz 0.0 f272 Jump frequency 2 0.0~fh (Hz) 0.0 f273 Jump step 2 0.0~30.0 Hz 0.0 f274 Jump frequency 3 0.0~fh (Hz) 0.0 f275 Jump step 3 0.0~30.0 Hz 0.0 f359 PID control switching 0: No PID 1: Process PID control (temperature, 0 pressure, etc.) 2: Speed PID control (potentials etc.) f360 PID control feedback control signal selection 3: Stop holding P control 0: Deviation input (no feedback input) 1: VI/II (voltage/current input) 2: RR/S4 (potentiometer/voltage input) 3: RX (voltage input) 4: Option AI1 (differential current input) 5: Option AI2 (voltage/current input) 6: PG feedback option f361 Delay filter 0.0~25.0 0.1 f362 Proportional (P) gain 0.01~100.0 0.10 f363 Integral (I) gain 0.01~100.0 0.10 0 3

f364 PID deviation upper limit ll~ul (Hz) ul f365 PID deviation lower limit ll~ul (Hz) ul f366 Differential (D) gain 0.00~2.55 0.00 f367 Process upper limit ll~ul (Hz) ul f368 Process lower limit ll~ul (Hz) ll f369 PID control waiting time 0~2400 (sec.) 0 f370 PID output upper limit ll~ul (Hz) ul f371 PID output lower limit ll~ul (Hz) ll f372 Process increasing rate (speed 0.1~600.0 10.0 type PID control) f373 Process decreasing rate (speed 0.1~600.0 10.0 f660 f661 f702 f703 f729 type PID control) Override addition input selection Override multiplication input selection Frequency free unit display magnification Frequency free unit conversion selection Operation panel override multiplication gain 0: Deselect 0 1: VI/II (voltage/current input) 2: RR/S4 (potentiometer/voltage input) 3: RX (voltage input) 4: Operation panel input enabled (including LED/LCD panel option input) 5: Operation panel RS485 (2-wire) communications input 6: Internal RS485 (4-wire) communication input 7:Communications option input 8:Option AI1 (differential current input) 9:Option AI2 (voltage/current input) 10:UP/DOWN frequency 11:RP pulse input 12:High-speed pulse input 13:Binary/BCD input 0:Deselect 0 1:VI/II 2:RR/S4 3:RX 4: f729 5:AI1 0.00:OFF, 0.01~200.0 0.00 0: All frequencies display free unit selection 1: PID frequencies free unit selection -100~100 (%) 0 0 [Input/output terminal function] Positive Negative logic logic Function 36 37 PID control OFF selection Input terminal 52 53 PID differentiation/integration reset 54 55 PID forward/reverse switching Output terminal 38 39 PID deviation limit [FM/AM pulse output and monitor output function] FM/AM/pulse output Monitor output Option No. Communi cation No. Option No. Communi cation No. 13 FD22 13 FE22 PID feedback value Function 4

For PID control, the process value and the feedback value are converted into frequencies for reasons of processing. However, the need to convert the process value and the feedback value into frequencies can be eliminated by the use of parameters f702 (free unit selection) and f703 (conversion item selection). (Refer to Section 2.1.13.) 1.2.2. Maximum frequency For the maximum frequency (fh), specify the highest frequency that the inverter can output. For PID control, you are recommended to specify a frequency 10% or so higher than the upper limit frequency (ul). (Refer to Section 1.2.5.) 1.2.3. Upper limit frequency For the upper limit frequency (ul), specify the upper limit frequency of the motor used. 1.2.4. Specifying the feedback value To select an input device for feedback value control signals, use the PID control feedback control signal selection parameter (f360). For analog input, refer to section 2.2. Set the zero point for the feedback value at 0Hz, and the maximum output for the feedback value at the maximum frequency. For example, if the output ranges from 4 to 20mA, set an output of 20% at 0Hz and an output of 100% at the maximum frequency. Example of VI/II terminal setting aif2 (80Hz) When maximum frequency is 80 Hz f202 (0Hz) 4mA f201 20%100% 20mA f203 100% 5

[ Feedback value input setting ] Description PID control feedback control signal selection (f360) Deviation input (no feedback input) 0 VI/II (voltage/current input) 1 RR/R4 (potentiometer/voltage input) 2 RX (voltage input) 3 AI1 (differential current input) 4 AI2 (voltage/current input) 5 PG feedback option 6 The characteristic can be reversed by changing parameter settings. Example of VI/II terminal setting f202 (80Hz) When maximum frequency is 80Hz aif2 (0Hz) 4mA f201 20% 20mA f203 100% The characteristic of the feedback value can also be reversed by means of a signal from an external device. Example: To use the S3 terminal as a PID normal/reverse characteristic switching signal input terminal Title Function Adjustment range Examples of settings f117 Input terminal function selection 7 (S3) 0~135 54 (positive logic) 55 (negative logic) [When switching between the PID normal and reverse characeristic of the feedback value (maximum frequency: 80Hz) to the VI/II terminal, using the S3 terminal] 80Hz 0Hz 4mA 20% 20mA 100% OFF between S3 and CC ON between S3 and CC Title Function Default setting aif2 VI/II input point 2 frequency 80 f117 Input terminal function 54 selection 7 (S3) f201 VI/II input point 1 setting 20 f202 VI/II input point 1 frequency 0 f203 VI/II input point 2 setting 100 6

1.2.5. Specifying the process value The process value is determined by the frequency command value set with a frequency setting mode selection parameter (fmod or f207). When specifying a frequency command value, set a target for the feedback value as the process value. For analog input, refer to section 2.2. The process value can also be specified with a preset speed operation frequency setting parameter. [ Process value input setting ] Description Frequency setting mode selection 1 (fmod) Frequency setting mode selection 2 (f207) VI/II (voltage/current input) 1 RR/S4 (potentiometer/voltage input) 2 RX (voltage input) 3 Operation panel input enabled (including LED/LCD 4 panel option input) Operation panel RS485 (2-wire) communication input 5 Internal RS485 (4-wire) communication input 6 Communications option input 7 Option AI1 (differential current input) 8 Option AI2 (voltage/current input) 9 UP/DOWN frequency 10 RP pulse input 11 High-speed pulse input 12 Binary/BCD input 13 7

An example of the setting of the process value In the system shown in the figure below in which the feedback value (4 to 20mA (1 to 2 atm)) is input via the VI/II terminal, the process value is input via the RR/S4 terminal and the maximum frequency is set at 80Hz, the process value is set so that the feedback value will be 1.5 atm when the pressure is set at 1.5 atm. In the example shown below, a process valueof 5V corresponds to a pressure of 1.5 atm and to a frequency command value of 40Hz. (Note that the actual output frequency is not always 40Hz.) Example of a system Parameter setting : fmod =2 (RR/S4 input) f360 =1 (VI/II input) fh =80.0 ul =70.0 Power supply R S T U V W M P Pressure sensor Pump External analog setting DC: 0~10V Feedback signal DC: 4~20mA (II input) DC: 2~10V (VI input) RR/S4 CC II CC (VI) 1 to 2 atm 2atm Feedback value Feedback value Process value Process value (converted into frequency) (converted into frequency) 80Hz 2atm 70Hz 1.5 atm 40Hz 1atm 0Hz 1atm 0Hz 4mA 20mA 4mA 20mA 0V 10V 0V 5V 10V Feedback value (4~20mA) Process value (0~10V) Operation frequency command value (Hz) 4 0 0 8 2.5 20 12 5.0 40 16 7.5 60 20 10 80 * The actual motor operation frequency varies according to the PID control results and does not always agree with this frequency. 8

Note: If the process value is 10V at 80Hz, the deviation will become zero when the feedback value is 20mA at 80Hz. If the actual output frequency increases at that time, the feedback value will be limited to the maximum frequency and it will not exceed 80Hz at 20mA, and therefore the output frequency will be fixed at 80Hz. In the example shown above, therefore, you can prevent the output frequency from being fixed at the maximum frequency by setting the upper limit frequency at 70Hz or so, as described in section 1.2.3, Upper limit frequency. Therefore, the process value or the frequency should be set lower than the maximum frequency. 1.2.6. Acceleration/deceleration time Set the acceleration/deceleration time (acc/dec) carefully so that it will not cause the inverter to trip. The longer acceleration/deceleration time, the slower the speed of response of process PID control. The smaller acceleration/deceleration time, the bigger the risk of tripping of the inverter. 1.2.7. Upper limit frequency, lower limit frequency and jump frequency The upper limit frequency (ul), the lower limit frequency (ll) and the jump frequencies set with parameters f270 to f275 are valid for output frequencies. 1.2.8. Override processing The override processing settings made with f660 and f661 are valid for the process value. These parameters are used to fine adjust the process value. 1.2.9. Operation starting frequency The operation starting frequency set with f240 or f241 is valid for output frequencies. Operation starts when the output frequency increases to the operation starting frequency (f240+f241) or above, and it stops when the output frequency decreases to the operation starting frequency (f240-f241) or below. 1.2.10. Switching to open loop operation To switch from PID operation (automatic operation) to open loop operation (manual operation), use the PID control OFF selection functions (input terminal functions: 36 and 37). When switching to open loop operation, take care because the acceleration/deceleration time is very short at that time because of PID control. (Use the acceleration/deceleration time 2 parameter or any other proper parameter, if necessary.) 9

1.2.11. Resetting the integral gain and differential gain set for PID control To reset the integral gain and differential gain set for PID control (automatic operation), use the PID differential gain and integral gain reset functions (input terminal functions: 52 and 53). 10

2. Adjusting PID control gains E6581329 Adjust PID control gains according to the process value, the feedback input signal and the item to be controlled. Here are the parameters used to adjust PID control gains. Default Title Function Adjustment range setting f361 Delay filter 0.0~25.0 0.1 f362 Proportional (P) gain 0.01~100.0 0.10 f363 Integral (I) gain 0.01~100.0 0.10 f364 PID deviation upper limit ll~ul (Hz) ul f365 PID deviation lower limit ll~ul (Hz) ul f366 Differential (D) gain 0.00~2.55 0.00 f367 Process upper limit ll~ul (Hz) ul f368 Process lower limit ll~ul (Hz) ll f369 PID control waiting time 0~2400 (sec.) 0 f370 PID output upper limit ll~ul (Hz) ul f371 PID output lower limit ll~ul (Hz) ll f372 f373 f702 f703 Process increasing rate (speed type PID control) Process decreasing rate (speed type PID control) Frequency free unit display magnification Frequency free unit conversion selection 0.1~600.0 10.0 0.1~600.0 10.0 0.00:OFF, 0.01~200.0 0.00 0:All frequencies display free unit selection 1:PID frequencies free unit selection 0 2.1.1. Adjusting the proportional (P) gain The proportional (P) gain set with f362 is the proportional (P) gain obtained by PID control. A proportional (P) gain, a factor by which the deviation (difference between the process value and the feedback value) is multiplied, is used to perform control in such a way as to make a correction in proportion to the deviation. Although setting this gain high is effective in increasing the response speed, setting it excessively high may cause an unstable operation, such as vibration. Output frequency High proportional gain f362 Fast response Process value reference Low proportional gain f362 Slow response Time 11

2.1.2. Adjusting the integral (I) gain The integral (I) gain set with f363 is the integral (I) gain obtained by PID control. The integral gain reduces the deviation remaining after proportional control to zero (offsetting of residual deviation). Although setting this gain high is effective in reducing the residual deviation, setting it excessively high may cause an unstable operation, such as vibration. Output frequency Low integral gain f363 Process value reference Residual deviation High integral gain f363 Time 2.1.3. Adjusting the differential (D) gain The differential (D) gain set with f366 is the differential (D) gain obtained by PID control. The differential gain increases the speed of response to rapid changes in deviation. If this gain is set excessively high, a phenomenon in which the output frequency greatly fluctuates may occur. Previous deviation - Current deviation Time Output frequency High differential gain Low differential gain Time 2.1.4. Adjusting the delay filter The delay filter set with f361 moderates changes in deviation (primary delay control). Its setting does not need to be changed under normal conditions. Specify a small value to increase the processing speed or a large value to reduce it. 2.1.5. Adjusting the PID deviation upper limit The PID deviation upper limit set with f364 is the upper limit to the increase (+) in deviation. It limits momentary deviations. It does not need to be changed under normal conditions. 12

2.1.6. Adjusting the PID deviation lower limit The PID deviation lower limit set with f365 is the lower limit to the decrease (-) in deviation. It limits momentary deviations. It does not need to be changed under normal conditions. 2.1.7. Adjusting the target upper limit The target upper limit set with f367 is the upper limit to the process value. It limits the process value. It is set at the same frequency as the upper limit frequency (ul) and it does not need to be changed under normal conditions. 2.1.8. Adjusting the target lower limit The target lower limit set with f368 is the lower limit to the process value. It limits the process value. It is set at the same frequency as the lower limit frequency (ll) and it does not need to be changed under normal conditions. 2.1.9. Adjusting the PID start waiting time If you do not want your inverter to start PID control before the control system becomes stable, for example, immediately after startup, you can specify a waiting time during which the inverter does not start PID control. During the PID control waiting time set with f369, the inverter carries out operation at the frequency determined by the process value, ignoring feedback input signals, and on expiration of the specified waiting time, it goes into PID control mode. 2.1.10. Adjusting the PID output upper limit The PID output upper limit set with f370 is the upper limit to frequencies output by PID control. It is set at the same frequency as the upper limit frequency (ul) and it does not need to be changed under normal conditions. 2.1.11. Adjusting the PID output lower limit The PID output lower limit set with f371 is the lower limit to frequencies output by PID control. It is set at the same frequency as the lower limit frequency (ll) and it does not need to be changed under normal conditions. 13

2.1.12. Adjusting the increase and decrease rates of the target value The target value increase and decrease rates set with f372 and f373, respectively, determine the feedback value or the response during speed PID control. To increase the speed of response, specify low rates. 2.1.13. Converting the units of the process value and feedback value For PID control, the process value and the feedback value need to be converted into frequencies for reasons of processing, but the need to convert them into frequencies can be eliminated by the use of parameters f702 (free unit selection) and f703 (conversion item selection). If f703 is set to 1, the values obtained by multiplying the frequencies displayed on the monitor or specified with the following parameters by the value specified with f702 are displayed. [Value displayed] = [Frequency displayed on the monitor or specified with a parameter] [value specified with ] [Parameters] Title f364 f365 f367 f368 Function PID deviation upper limit PID deviation lower limit Process upper limit Process lower limit [FM/AM pulse output and monitor display] FM/AM pulse output Monitor output Option No. Communication No. Option No. Communication No. Function 1 FD02 1 FE02 Operation frequency command value 13 FD22 13 FE22 PID feedback value 14

2.2. Adjusting the analog command voltage E6581329 For items which can be adjusted by feedback input, such as voltage/current input (VI/II input), potentiometer/voltage input (RR/S4 input) and voltage input (RX input), adjust the voltage scaling factor if necessary. For example, when feedback signals are very weak, the gain can be increased by this adjustment. Example of setting when VI/II is used as a voltage input terminal (factory default setting) aif2 (80Hz) Example of setting when VI/II is used as a current input terminal aif2 (80Hz) (f108 needs to be set to 1) f202 (0Hz) 2V f201 20 10V f203 100 f202 (0Hz) 4mA f201 20 20mA f203 100 Example of RR/S4 terminal setting (default setting) avf2 (80Hz) f211 (0Hz) 0V 10V f210 f212 0% 100% Example of RX terminal setting (default setting) f219 (80Hz) f217 (0Hz) 0V 10V f216 f218 0% 100% 15