Commercial Microwave Technical Information. CAUTION All safety information must be followed as provided in Service Manual

Similar documents
CAUTION All safety information must be followed as provided in Service Manual

CAUTION All safety information must be followed as provided in Service Manual

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

CAUTION All safety information must be followed as provided in Service Manual

Service Commercial Microwave Oven DEC18M* & MDC18MT Models

Service / Training Manual High Speed Combination Oven

USER'S MANUAL DMR-6700

Intro Introduction by the author, John C Gallawa. EMnrgy Understanding the basic principles of electromagnetic energy

SERVICE MANUAL R-21AT SHARP CORPORATION COMMERCIAL MICROWAVE OVEN MODEL

1 SAFETY INSTALLATION OPERATION COMPONENTS FAULT DIAGNOSTICS FUNCTIONS TECHNICAL SPECIFICATIONS...

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

Load-Trainer Transformer Simulator

400Amp True RMS AC/DC Clamp Meter Model EX613

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

Load-Trainer Transformer Simulator

200Amp AC Clamp Meter + NCV Model MA250

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

R PROFLAME Instruction Book Collection

DVM1190 DIGITAL MULTIMETER

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Multimeter Definition

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

400Amp True RMS AC Clamp Meter + NCV

Page 1 T O O L S A N D M AT E R I A L S R E Q U I R E D. 1. Screwdriver 2. Carpenter's level 3. Electrical Tape PA R T S L I S T. A.

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

79/26 Series III Multimeter

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

Compact MultiMeters + Voltage Detector

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

EDACS WALL MOUNT STATION. Maintenance Manual. Mobile Communications LBI-31838A TABLE OF CONTENTS

Agilent U1253B True RMS OLED Multimeter. Quick Start Guide

POWERLINE HEAVY DUTY ISOLATORS

Remote Control Outlets Operating Instructions

AMM-1022 Digital Multimeter USER`S MANUAL

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

R/C SMD Tweezers Multimeter Model RC200

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

270 manual.qxd 5/9/2005 3:04 PM Page 1. Digital Clamp-on Meter Instruction Manual

M-1000D DIGITAL MULTIMETER

DPAfour125, DPAfour250 AMPLIFIERS. Operating Manual

Autoranging Multimeter Extech EX503

1507/1503. Insulation Testers. Users Manual

User s Guide. 400A AC/DC Clamp Meter. Model MA220

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

100V version: 100 volts AC, 50/60 Hz, 900W 120V version: 120 volts AC, 60 Hz, 900W 240V version: 240 volts AC, 50 Hz, 900W

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

FOXCART 400 MARK II OPERATION AND SERVICE MANUAL FOXTRONICS LOVE FIELD - DALLAS TEXAS MODEL PR APPROX. 550POUNDS THE POWER CART WITH MUSCLE

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

What is a multimeter?

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

Portable Appliance Testers. OmegaPAT MI 2140 BetaPAT MI 2141 User Manual Ver Code No

EVERGREEN EM INSTALLATION GUIDE

1.General instructions Specifications Description...7

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

UNITY/I TM. Installation Manual. UT3K, UT4K, UT5K and UT8K. Single-Phase Uninterruptible Power Systems

MULTIMETER TRAINING UNIT QUICKSTART GUIDE

User Manual. All rights reserved. Specifications are subject to change without notice.

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

LOM-15 CD-LOM15-01 PRODUCT OVERVIEW. Product. Description. Specifications SKU: LOM-15. Duplex Receptacle

Model DIGITAL MULTIMETER

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

SureTest Model ST-1THD & ST-1THDC Instructions

Module 1, Lesson 2 Introduction to electricity. Student. 45 minutes

BC145 SIGNAL ISOLATOR BOARD

OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

BULLETIN # B

Tap Changer Analyzer & Winding Ohmmeter RMO-TT

DM-45 Digital Multimeter

ATD-5519 Auto-Ranging Digital Multimeter Owner s Manual Features:

INDEX. Micro-ohmmeter MH-10 Page 3. MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4

LBI-4938C. Mobile Communications MASTR II POWER AMPLIFIER MODELS 4EF4A1,2,3. Printed in U.S.A. Maintenance Manual

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

Model 7000 Low Noise Differential Preamplifier

User Manual. All rights reserved. Specifications are subject to change without notice.

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

Tap Changer Analyzer & Winding Ohmmeter RMO-TD Series

Alternating Current Power

Agilent U1273A/U1273AX Handheld Digital Multimeter. Quick Start Guide

Advanced Test Equipment Rentals ATEC (2832)

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623

Continental's 816R -5B, 35 kw Single Tube Broadcast Transmitter. Includes the 802A solid -state exciter

Tap Changer Analyzer & Winding Ohmmeter RMO-TT

TECH SHEET - DO NOT DISCARD PAGE 1

The 21st Century R-390A/URR Reference Y2K-R3 Edited 7/09: No Technical Changes Chapter 2 - Operation. Page Table Of Contents 2-1

TWA Series Three-Phase Winding Ohmmeters & Tap Changer & Winding Analyzers

INSTALLATION GUIDE MICROWAVE OVEN UPMC3084ST. MFL _00

12B/18 MultiMeter Instruction Sheet

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

MFJ ENTERPRISES, INC.

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

30XR-A Professional Digital Multimeter Users Manual

Transcription:

Commercial Microwave Technical Information 0 V, 0 Hz Models RCS0MPA P00M RCS0A P00M RCS0PBDA P00M RCS0MPSA P00M RFSMPSA P00M RFSSWA P00M RCS0SWA P0M RCS0MPA P0M Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit. Refer to Service Manual 0 for installation, operating, testing, troubleshooting, and disassembly instruction. CAUTION All safety information must be followed as provided in Service Manual 0.! To avoid the risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor Models RCS0MPA, RCS0MPSA, RCS0A, RCS0SWA, RCS0PBDA RFSMPSA, RFSSWA Power Source Voltage AC 0 VAC 0 VAC Amperage (Single Unit) A 0 A Frequency 0 Hz 0 Hz Single Phase, wire grounded X X Receptacle -R -0R Plug -P -0P Power Output Nominal microwave energy (IEC0) 000 Watts 00 Watts Minimum temperature rise ( T) 0ºF / ºC ºF /.ºC Operating Frequency 0 MHz 0 MHz Power Consumption Cook Condition Microwave 00 Watts /. Amps 00 Watts /. Amps Dimensions Cabinet Width /" cm /" cm Height /". cm /". cm Depth 0 /". cm 0 /". cm Oven Interior Width /". cm /". cm Height ". cm ". cm Depth /". cm /". cm Weight Crated lbs. kg lbs. kg Uncrated lbs. kg lbs. kg April 00 0 00 Maytag Services Replaces 0

Illustration Component Testing Results Thermal cutout Disconnect all wires from TCO. Measure resistance across terminals. Cavity TCO... Magnetron TCO... Closed at F (0 C) and Opens at 0 F (0 C) Closed at 0 F (0 C) and Opens at 0 F (0 C) Diode Capacitor Remove diode lead from capacitor and connect ohmmeter. Reverse leads for second test. Infinite resistance should be measured in one direction and 0KΩ or more in the opposite direction. NOTE: Ohmmeter must contain a battery of volts minimum. Magnetron Remove wires from capacitor terminals and connect ohmmeter, set on highest resistance scale to terminals. Also check between each terminal and capacitor case. Between Terminals: Meter should momentarily deflect towards zero then return to over MΩ. If no deflection occurs, or if continuous deflection occurs, replace capacitor. Terminal to Case: Infinite resistance Between Terminals: Less than Ω Blower motor Remove wires from magnetron and connect ohmmeter to terminals. Also check between each terminal and ground. Remove all wires from motor. Each terminal to ground measures Infinite resistance. Note: This test is not conclusive. If oven does not heat and all other components test good replace the magnetron and retest. Measure resistance across coil... Approximately Ω Stirrer motor Remove all wires from motor. Measure resistance across terminals... Approximately. KΩ Secondary Primary Filament Transformer Noise filter board Remove all wires from terminals. Measure resistance from: Primary... Filament... Secondary to Ground screw on transformer stack... Power In terminals... Power Out terminals... Less than < Ω Less than < Ω Approximately 00 0 Ω 0 VAC 0 VAC If no power in, check power outlet. If no power out, check fuses. 0 April 00 Replaces 0 00 Maytag Services

Illustration Component Testing Results Interlock switch assembly Disconnect wires to switch. Monitor Primary With door open measure resistance from: Monitor - Terminal -... Primary - Terminal -... Secondary - Terminal -... With door closed measure resistance from: Monitor - Terminal -... Primary - Terminal -... Secondary - Terminal -... Indicates continuity Infinite Ω Infinite Ω Infinite Ω Indicates continuity Indicates continuity After verifying or replacing the Secondary module, reconnect wires to switch and check operation of monitor circuit before operating the oven. Lamp receptacle Test continuity of receptacle terminals. Indicates continuity with bulb installed. Wire Harness Test continuity of wires Indicates continuity Electronic Control Panel Service Test Mode: Open door, Press and Hold pad for seconds to enter service test mode. Press... Press... Press... Press... Press... Press... Press... Press... Press... Press 0... Stop/Reset... Error codes: E-0... E-0... E-0... SERVICE appears in the display Indicates number of hours magnetron has been turned on Indicates number of times magnetron tube has been turned on and off Indicates number of door cycles CLEAR (Press pad to reset service data.) Indicates amperage RESET (Clear Service Alarm) Exit Service Test Mode Replace Control Board Replace Control Board Shorted or Open Keypad Test and replace if necessary Hidden Hidden Electronic Dial Control Panel Service Test Mode: Open door, Press and Hold Hidden for seconds to enter service test mode. 0% 0% DEFROST Press Hidden... Press Hidden again... Press Hidden again... Press Hidden again... Press Hidden again... Press Hidden again... Enters into Service Test Mode Indicates number of magnetron hours Indicates tube cycles Indicates number of door cycles Indicates amperage Turn dial to Clear Info When dial is rotated display indicates CLEARED INFO April 00 0 00 Maytag Services Replaces 0

Illustration Component Testing Results Electronic Control Keyboard assembly is indicated as 00 Ω and below. RCS0MPA RCS0SWA RFSSWA Electronic Control RCS0MPSA RFSMPSA Electronic Control RCS0A Dial Control RCS0PBDA 0 Keyboard assembly 0 Keyboard assembly 0 Keyboard assembly 0 is indicated as 00 Ω and below. is indicated as 00 Ω and below. is indicated as 00 Ω and below. 0 HOLD (0%) DEFROST (0%) MEDIUM (0%) MED-HI (0%) 0 QTY X HOLD (0%) DEFROST (0%) MEDIUM (0%) MED-HI (0%) 0 0 QUICK SET HIDDEN # HIDDEN # DEFROST (0%) MEDIUM (0%) MED-HI (0%) & & & & & & & & & & & 0 & 0 & 0 & 0 & 0 & 0 & 0 & & & & & & & & & & & & 0 & 0 & 0 & 0 & 0 & 0 & 0 & & & & & & & & & & & 0 & 0 & 0 & & & & 0 & 0 & 0 & 0 & 0 & 0 0 April 00 Replaces 0 00 Maytag Services

RY RLY TAB TAB CN Function Test Set-Up / Meter Probe Placement Results Condition Setting Control transformer All Conditions CN Pin to Pin (White to Black) 0 VAC input Oven light relay RY Standby... Ready... CN Pin to Pin (Yellow to Black).. CN Pin to Pin... 0 VAC 0 VAC Blower / Stirrer motor relay RY Secondary Interlock Switch Cook... Standby... Ready... Cook... Door Closed... Door Opened... CN Pin to Pin... CN Pin to Pin (Brown to White). CN Pin to Pin... CN Pin to Pin... CN Pin to Pin (Pink to Green)... CN Pin to Pin... 0 VAC 0 VAC 0 VAC 0 VAC < Ω Infinite Cook relay RY Disconnect wires from relay Current transformer input Current transformer output Standby... Ready... Cook... Relay Terminal to Terminal... Relay Terminal to Terminal... Relay Terminal to Terminal... Infinite Infinite < Ω All Conditions Tab to Power Cord White (Neutral) 0 VAC All Conditions Tab to Power Cord White (Neutral) 0 VAC April 00 0 00 Maytag Services Replaces 0

All Amana and Menumaster microwave oven power outputs are rated using the IEC0 standards. Using the IEC0 test method requires precision measurements and equipment that is not practical to be performed in the field. Using the test shown below will indicate if the oven performance is satisfactory. Test equipment required: 000 ml test container and thermometer (Amana power test kit R0 Fahrenheit / Menumaster power test kit MD Celsius). Digital watch / watch with a second hand for use on ovens with electromechanical timers. Important Notes: Low line voltage will cause low temperature rise / power output. Ovens must be on a dedicated circuit, properly grounded, and polarized. Other equipment on the same circuit may cause a low temperature rise / power output. This test and results are not a true IEC0 test procedures and are only intended to provide servicers with an easy means of determining if the microwave oven cooking output is correct. Procedure. Fill the test container to the 000 ml line with cool tap water. NOTE: Water temperature should be approximately 0 F / C. Using the thermometer, stir water for five to ten seconds; measure, and record the temperature (T).. Place test container of water in the center of oven cavity and close door.. Heat the water for a -second full power cycle. NOTE: Use a digital watch or a watch with a second hand for ovens with electromechanical timers.. At end of the cycle, remove test container. Using the thermometer, stir water for five to ten seconds and record temperature (T).. Subtract the starting water temperature (T), from the ending water temperature (T) to obtain the temperature rise ( T).. If the temperature rise ( T) meets or exceeds the minimum, the test is complete. If the temperature rise ( T) fails to meet the minimum temperature rise, test the line voltage to verify it is correct. Then repeat steps - making sure to change the water. If the temperature rise ( T) fails to meet the minimum temperature rise again the oven will require service. Minimum Temperature Rise at Thirty -Three () Seconds Run Time T Cooking T Cooking T Cooking T Cooking ( F) Power Output ( F) Power Output ( C) Power Output ( C) Power Output 0... 000 0... 000... 000... 000... 00... 00.... 00... 00... 00... 00.... 00... 00... 00... 00.... 00... 00... 00... 00.... 00... 00... 00... 00 0... 00... 00... 00 0... 000 0.... 00... 000 0 April 00 Replaces 0 00 Maytag Services

Wiring and Schematic Diagrams CONTROL OPTIONAL! HIGH VOLTAGE DANGER April 00 0 00 Maytag Services Replaces 0