ADC COMPACT FULL-LEG/FULL-SPINE APPLICATION SOFTWARE USER MANUAL

Similar documents
MUSICA Nerve Center. Artificial Intelligence. Intelligent tools for your Digital Radiography workflow. Fluoroscopy. Workflow Optimization

CR35-SP+ Computed Radiography (CR) System. Innovations in Digital Imaging

DR _ solutions. We understand that customers don t need just products, they want. solutions

The Flash IIP Console is the heart of every FCR system. It s designed to maximize productivity in the busiest environments.

PANalytical X pert Pro High Resolution Specular and Rocking Curve Scans User Manual (Version: )

FCR XL-2 and FCR XC-2. High-quality digital x-ray that's perfect for your private practice.

Nuclear Associates , , , , , ,

Alignment of the camera

Principles of CT scan

COMPUTED RADIOGRAPHY CHAPTER 4 EFFECTIVE USE OF CR

CR Basics and FAQ. Overview. Historical Perspective

Exposure Indices and Target Values in Radiography: What Are They and How Can You Use Them?

PANalytical X pert Pro Gazing Incidence X-ray Reflectivity User Manual (Version: )

DR General Radiography System. DR Series

Product data Remote Controlled Table

R/F. Comparison of Long View Radiography Systems. 1. Introduction. 2. Methods of Long View Radiography

Calibration Aids for Metron

OTC18 OVERHEAD TUBE CRANE SYSTEM

ddraura Series Productivity meets versatility

Geometric Functions. The color channel toolbar buttons are disabled.

Touch Screen Technology. Classic WAIV. with Touch Screen Technology. Legendary Reputation...Sensitivity to your budget

Medical Imaging. Digital R/F remote controlled table. radiology ahead

RAD 150 RADIOLOGIC EXPOSURE TECHNIQUE II

Digital Imaging CT & MR

STEM Spectrum Imaging Tutorial

VARVE MEASUREMENT AND ANALYSIS PROGRAMS OPERATION INSTRUCTIONS. USING THE COUPLET MEASUREMENT UTILITY (Varve300.itm)

History of digital imaging

Cassette DR Solution. FDR D-EVO G43i. Square shaped cassette enabling enhanced operability and multipurpose use ISS. Wireless

Attikon, Rimini 1, , Athens, Greece , Athens, Greece , Athens, Greece

X o- System. Chiro- Systems. Chiropractic X-Ray Systems and Digital Solutions. Digital Radiography Computerized Radiography Chiropractic Systems

SYLLABUS. TITLE: Equipment Operation I. DEPARTMENT: Radiologic Technology

Maximizing clinical outcomes

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS

Why Agfa HealthCare? Power Drop-and-go cassette buffer Throughput

The Versatile and Powerful ACLxy. ACLxy

Registering and Distorting Images

efficiency ddrcompact Series

Enhanced Functionality of High-Speed Image Processing Engine SUREengine PRO. Sharpness (spatial resolution) Graininess (noise intensity)

Ysio Max. The most direct way to the image. Answers for life.

Stitching MetroPro Application

X-RAYS - NO UNAUTHORISED ENTRY

Advanced Diploma in. Photoshop. Summary Notes

Y11-DR Digital Radiography (DR) Image Quality

Be aware that there is no universal notation for the various quantities.

Digital Imaging Considerations Computed Radiography

MXHF-1500RF is controlled by Digital key panel console that displays KV, ma and mas with APR menu programmed.

Operation Manual. Canon CXDI-1 System Digital Radiography

Confocal Application Notes Vol. 5 July 2010

Cropping and Scaling for High Resolution Prints

X-RAY MEDICAL EQUIPMENT

Related topics Beam hardening, cupping effect, Beam hardening correction, metal artefacts, photon starvation

Invisible sophistication. Visible simplicity. CS Welcome to the simplicity of compact panoramic imaging

Luminos RF Classic. Where value meets performance.

The Fastest, Easiest, Most Accurate Way To Compare Parts To Their CAD Data

Advance Steel. Tutorial

Philips EasyDiagnost Eleva

Photoshop Elements Hints by Steve Miller

Solutions Page Content ImagePilot. Primary keywords: Digital radiography Computed radiography Image viewing and storage

Objective Evaluation of Radiographic Contrast- Enhancement Masks

DIGITAL RADIOGRAPHY ARTIFACTS

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

Digital radiography (DR) post processing techniques for pediatric radiology

IDEXX-PACS * 4.0. Imaging Software. Quick Reference Guide

Observer Performance of Reduced X-Ray Images on Liquid Crystal Displays

ddraura Series Productivity meets versatility

FMT18 FLOOR MOUNTED SYSTEM

CS The Ideal Solution for the Transition to Digital

CONSOLE ADVANCE The He art of Your FDR/ FCR System

Quick Operation Guide

DX-M CR SOLUTION DX-M. The next generation CR System for Digital Mammography and General Radiography.

Direct Print User Guide You don t even need a computer! Just connect your camera to your printer and print

Digital Design and Communication Teaching (DiDACT) University of Sheffield Department of Landscape. Adobe Photoshop CS4 INTRODUCTION WORKSHOPS

Chapter 6: TVA MR and Cardiac Function

China Resources Wandong Medical Equipment Co., Ltd. High Frequency 50kW Digital RF System - HF51-5

Drawing with precision

RADspeed Pro. EDGEpackage C501-E041C

Acquisition, Processing and Display

v Introduction Images Import images in a variety of formats and register the images to a coordinate projection WMS Tutorials Time minutes

AUTOMATION OF 3D MEASUREMENTS FOR THE FINAL ASSEMBLY STEPS OF THE LHC DIPOLE MAGNETS

DirectView CR 850 System. A fast, premium single-cassette CR system

AF DDRS Phosphor Storage Plate Placement Guide

5 Press the Up/Down arrow keys to select the desired tray, followed by the Confirm

A Practical Overview of the Clinical and Operational Impact of Computed Radiography(CR) Implementations. Shirley Weddle, RT(R)(M), CIIP, BBA

Fire CR Calibration Guide

COMPUTED RADIOGRAPHY (CR)

Essentials of Digital Imaging

Shape sensing for computer aided below-knee prosthetic socket design

productivity ddrformula Series

PLD5600A High Frequency Digital Gastrointestinal &DR System(630mA)

Parity and Plane Mirrors. Invert Image flip about a horizontal line. Revert Image flip about a vertical line.

Photoshop CS2. Step by Step Instructions Using Layers. Adobe. About Layers:

ISO INTERNATIONAL STANDARD

User Manual Veterinary

Lesson 6 2D Sketch Panel Tools

Printer Software Guide

Artefacts found in computed radiography

Teaching Digital Radiography and Fluoroscopic Radiation Protection

Communication Engineering Prof. Surendra Prasad Department of Electrical Engineering Indian Institute of Technology, Delhi

How to combine images in Photoshop

3D Brachytherapy with Afterloading Machines

Transcription:

ADC COMPACT FULL-LEG/FULL-SPINE APPLICATION SOFTWARE USER MANUAL

TABLE OF CONTENTS Full-leg/full-spine image stitching: a new and accurate CR-based imaging software 1 The conventional approach 1 CR and the automation of full-body imaging 1 Steps in the image-stitching algorithm 3 Clinical advantages of the full-body imaging technique 4 Full-Leg/Full-Spine Stitching : how to proceed? 5 Introduction 5 Performing the examination 5 Method 1 : several plates in a full-leg/full-spine cassette 5 Plate and cassette selection 5 Making up the cassette 6 Exposure 7 Method 2 : several ADC cassettes in a special cassette-holder 8 i

Image Stitching 10 Opening the Full-Leg/Full-Spine mode and selecting the image series, using the Controller button 10 Full-Leg/Full-Spine mode and pre-composition adjustments 13 Image stitching proper 17 Manual correction 19 Returning to the Full-Leg/Full-Spine browser screen 21 ii

Full-leg/full-spine image stitching: a new and accurate CR-based imaging software The conventional approach Full-leg and full-spine radiological examinations require a larger portion of the body to be imaged than can be fitted onto even the largest single imaging cassette. Conventional screen/film radiography has evolved methods for dealing with this problem. When the sub-images generated on separate films are put together, grid lines are used to ensure that they are correctly aligned. However, the overall process is exacting and not always completely accurate. CR and the automation of full-body imaging The process for obtaining a full-leg/full-spine image using the ADC Compact system is similar to the method used in conventional radiography, except that the screen/film system is obviously replaced with phosphor plates. During exposure an attenuating grid is present in the path of the X-ray beam, which leaves the imprint of a regular framework of thin parallel horizontal and vertical lines on the images. But once the images have reached the workstation, they cannot easily be brought into perfect alignment, as the degree of distortion is not qualified or quantified. The automates the process of forming a geometrically accurate full-body image, with as little user interaction as possible. There are several sources of misalignment or skew, any or all of which may be present: overlap Typically, four 24 x 30 cm plates are arranged in a 30 x 90 cm cassette for a full-spine exam, and three 35 x 43 cm plates are arranged in a 35 x 105 cm cassette for a full-leg exam. Where the plates overlap, the image will be normally exposed for the plate lying on top, and less exposed for the plate underneath. 1

shift The displacement of an image in a direction perpendicular to the body axis. rotation Image rotation is caused by a slight rotation of the imaging plate in the cassette. interline distance foreshortening in vertical and/or horizontal direction is caused by a slight tilt in the plates from the vertical or horizontal plane. The digital image-processing algorithm of the ADC Compact Full-Leg/Full- Spine Application Software has been designed to correct all of these distortions simultaneously, and to assemble one composite image showing geometric continuity of body parts. This is the technique known as image stitching, as the anatomic entities crossing image borders are re-arranged in an uninterrupted and seamless way. 2

Steps in the image-stitching algorithm What are the key elements of the image-stitching algorithm used in the ADC Compact Full-Leg/Full-Spine Application Software? First, the sub-images are input into the user interface of the ADC Compact Interactive Processing software, where the operator indicates the order of the constituent images and rotates them where necessary, so that all body parts are in the upright position. From here, the stitching process proceeds automatically. The grid lines are now extracted from each image and stored in analytical form. In the grid calibration step, horizontal and vertical periodicity vectors are extracted and new target coordinate positions of all grid lines in each sub-image determined. A de-skewing operation follows, in which firstly the vertical grid lines and secondly the horizontal grid lines are shifted to their associated perfect target positions. Linear interpolation determines how much each pixel in the target image should be adjusted. A further interpolation process is now needed to resample the input image. The method selected for this (known as the cubic B-spline interpolating kernel ) computes the target pixel s value from the input image pixels in such a way as to maintain maximum image resolution. The result of this process is an image with equidistant and perfectly horizontal/vertical grid lines. It now remains to correct the overlap between successive images. After this has been done, the image-stitching module finally builds a composite total body image from the adjusted sub-images, omitting any overlap regions. 3

Clinical advantages of the full-body imaging technique Orthopedic diagnosis will benefit from this new and innovative application software in areas such as the assessment of scoleosis. Potential applications include, for example: accurate measurement of spine angles and distances between anatomic entities, assessment of the evolution of therapy over time, identification of orthopedic surgery indications. Others will no doubt emerge during routine use of the software package. 4

Full-Leg/Full-Spine Stitching : how to proceed? Introduction As explained above, full-spine and full-leg examinations require the use of several overlapping plates in a single cassette or the use of several ADC Compact cassettes in a specially-built cassette-holder. The sub-images that are created are then combined into a single image with the help of attenuating grid lines to ensure accurate alignment during exposure. The compensates for the various sources of misalignment referred to above, like overlap, shift, rotation and perspective foreshortening. The complete procedure is as follows. Performing the examination The requires the use of a special Planfeld grid during exposure. The minimal line distance of this grid must be more than 30 mm and the maximum line distance must be less than 70 mm. Currently there are two different methods for performing the exposure: Several plates in a full-leg/full-spine cassette Several ADC cassettes in a specially designed cassette-holder. The ensuing image composition or stitching process is identical whichever exposure method is used. Method 1 : several plates in a full-leg/full-spine cassette Plate and cassette selection Select the size of plate and cassette you are going to use. Typically, this will be : Four 24 x 30 cm plates with a 30 x 90 cm cassette for a full-spine examination. 5

Three 35 x 43 cm plates with a 35 x 120 cm cassette for a full-leg examination. Making up the cassette In order to make up the cassette, proceed as follows : 1 Put the first plate in the cassette on the extreme left-hand side. The plates phosphor side should be facing the black tube side of the cassette. Take care that the first (bottom of image) plate is completely exposed, as this is the reference plate. 2 Insert the remaining plates from left to right, as shown in the illustration below. All overlaps between the plates should be approximately 2 cm, except for the final one, which may need to be as much as 10 cm. z y x Plates Cassette Tube side 6

3 Close the cassette 4 Make sure that the special grid is in place, on the tube side of the cassette or in the cassette proper. Its line distance should be between 30 and 70 mm. 5 Use intensifying screens if appropriate. 6 The gradual filter is not necessary, as it can be simulated using Musica processing. Exposure After having made up the cassette, proceed as follows : 1 Make a complete exposure of the cassette. 2 Open the cassette and put all the plates back in the ADC cassettes. This can be done in daylight. 7

Method 2 : several ADC cassettes in a special cassette-holder The procedure to be followed is very similar to the first method using plates and cassettes. 1 Put three ADC Compact cassettes in the specially built cassette-holder, as shown above. The ADC cassettes used for this method are typically 14 x 17" cassettes. 2 Make a complete exposure of all three cassettes 3 Remove the cassettes from the cassette-holder and have them digitized 8

Note When identifying the Full-Leg/Full-Spine sub-images using the ADC Compact Identification Software, see to it that the relevant sub-images are identified as "full spine" or "full leg" examinations to make sure that the constituent images are accurately aligned, in an upright position and processed using the same image processing parameters. 9

Image Stitching In order to stitch the Full-Leg/Full-Spine sub-images into one composite image, proceed as follows: Opening the Full-Leg/Full-Spine mode and selecting the image series, using the Controller button 1 Click the Controller button in the interactive processing browser screen. Then select [Full Leg/Spine] in the drop-down menu, as shown below. Note When the [Full-Leg/Full-Spine] option has been opened using the Controller drop-down menu, the browser screen that is returned is identical to the browser screen used in interactive image processing, with the exception that it features two buttons, viz. an [INFO] button and a [STITCH] button. The Controller drop-down menu features the Full Leg/Spine functionality only when the has been licensed. 10

2 On the Full-Leg/Full-Spine browser screen, select all sub-images that will make up the desired composite image, starting with the anatomically bottommost image first and ending with the topmost image, as shown in the sample screen below. 3 Only after the selection of an image from the Full-Leg/Full-Spine browser screen do the [INFO] and [STITCH] buttons become active. The [INFO] button provides access to information pertaining to any selected image, but unlike the Info screens used in the Interactive Processing browser mode, the information shown in the Full-Leg/Full-Spine browser mode cannot be modified or edited. 11

The [STITCH] button can only be activated when at least two images have been selected in the Full-Leg/Full-Spine browser screen. Pressing the [STITCH] button initiates the first step in the stitching process. 12

Full Leg / Full Spine mode and pre-composition adjustments 1 Pressing the [STITCH] button in the Full-Leg/Full-Spine browser screen, causes a screen to appear displaying all the constituent images, one above the other, on the left-hand side of the screen. The first selected image is displayed at the bottom. If the constituent images are not displayed in the proper order, press [CANCEL] to return to the Full-Leg/Full-Spine browser screen and restart the whole process, selecting the constituent images that will make up the desired composite image, starting with the anatomically bottommost image first and ending with the topmost image. 13

2 Make any adjustments that are necessary. Wrong orientation of any individual constituent image can be corrected by turning the image in 90 steps, or by flipping it horizontally or vertically, using the set of three orientation buttons on the right of each constituent image, as shown in the sample screen below. 3 In the sample screen above, the third "abdominal" image appears to be wrongly orientated. Press the [TURN 90 ] button until the image is properly orientated and aligned. After the image has been rotated into its proper upright position, the system shows the following screen. 14

4 If all images are incorrectly orientated, as in the sample screen below, their orientation can be adjusted jointly using the bottommost set of orientation buttons. 15

Press the [TURN 90 ] button in the bottommost set of buttons twice to rotate all four constituent images together by 180. The system shows a screen displaying the constituent images properly orientated. 16

Image stitching proper 1 When the order and orientation of the constituent images is correct, press the [STITCH] button. The now assembles the sequence of constituent images into one composite image. A message asks you to wait until the total image has been calculated. This might take a few minutes because of the need for precision image rotation, skewing and deskewing operations and re-sampling of the image with retention of maximum image sharpness. 17

2 The resulting composite, "stitched" image is then displayed on the right. 18

Manual correction 1 Where overlap values are very small, the overlap computation may be erroneous, due to there not being enough pixels for reliable computation of cross-correlation values. 2 You can now manually correct, i.e. increase or decrease, the overlap between the constituent images vertically, using the [MORE] and [FEWER] correction buttons and, if necessary, shift the images to the right or to the left using the [ L ] and [ R ] buttons. These correction buttons appear to the left of the stitched image, one button for each image pair (1-2, 2-3 and 3-4). 19

3 Press [STITCH] a second time. This corrects the overlap value by the integral amount of Planfeld grid periods indicated by the vertical shift value. Although horizontal overlap errors are very unlikely to occur, a similar correction may be made to adjust the horizontal shift by an integral number of periods. 20

4 Again, a waiting message asks you to wait until the overlap has been recalculated. The system then shows the stitched image with the corrected overlaps. The stitched image is characterized by the presence of line-like sub-image separations. They are due to the non-scanned top portion of the second, third and fourth plate. Returning to the Full-Leg/Full-Spine browser screen 1 Press [SAVE] to save the correct composite image. If [CANCEL] is pressed the stitching result is ignored and you then simply return to the Full-Leg/Full- Spine browser screen. 21

2 Pressing [SAVE] causes the stitched image to appear in the browser. The newly created composite image is a 12-bit pyramidal image, which has all the image processing features that were applied to the first, i.e. bottommost, constituent image. Patient data associated with the composite image are also those linked with the first constituent image. 22

3 The newly composed image is now ready for operations such as MUSICA image enhancement enlargement of specific image portions 23

annotation, analyzing and angle measurements printing, and so on. For a more detailed description of the above image processing operations, refer to the relevant ADC Compact User Manuals. 24

25

Printed in Belgium Published by Agfa-Gevaert N.V., B-2640 Mortsel-Belgium