Instruction manual for Ocean Optics USB4000 and QE65 Pro spectroradiometers

Similar documents
BTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED.

BTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser.

Miniaturized Spectroradiometer

metcon meteorologieconsultgmbh, Instruments for Atmospheric Research W1aa_Feb_2017_1.doc 1 -

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration

BTS2048-VL-CP-ILED-B-IS-1.0-HL

ISS-30-VA. Product tags: Integrating Sphere Source. Gigahertz-Optik GmbH 1/5

We bring quality to light. MAS 40 Mini-Array Spectrometer

BTS256-E WiFi - mobile light meter for photopic and scotopic illuminance, EVE factor, luminous color, color rendering index and luminous spectrum.

Company synopsis. MSU series

RaySphere Solar Analysis System (RaySphere and RaySphere 1700) Installation and Operation Manual Document Number RAYSPHERE

Broadbandradiometer specbos 1211

LED Lighting Flux and Color Measurement System (LFC)

BTS256-EF. Product tags: VIS, Spectral Measurement, Waterproof, WiFi. Gigahertz-Optik GmbH 1/7

Instruction manual for Bentham DM-150 and DTMc300 spectroradiometers

Integrated Diode Laser System DioPower

Development of 2 Total Spectral Radiant Flux Standards at NIST

Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration

Product tags: VIS, Spectral Data, Color Temperature, CRI, Waterproof, WiFi, Luminous Color, LED, Photometry, General lighting

Spectroradiometer specbos 1201

Instruction Manual of Luminance and Spectral Radiance Calibrations

BTS256-PAR. Product tags: VIS, Spectral Data, PAR, Waterproof, General lighting.

Specifications Summary 1. Array Size (pixels) Pixel Size. Sensor Size. Pixel Well Depth (typical) 95,000 e - 89,000 e -

JETI Specbos Instruments

BiRT-2.0 Bi-directional Reflectance and Transmittance Distribution Function Measurement System

Miniature Spectrometer Technical specifications

We bring quality to light. CAS 120 CCD Array Spectrometer

ULS24 Frequently Asked Questions

JETI SCPI commands schematic and in examples

We bring quality to light. CAS 140CT Array Spectrometer

Microscope-Spectrometer

A Laser-Driven Light Source (LDLS) as a portable spectral irradiance calibration source in the UV range and other radiometric applications.

TracQ. Basic Data Acquisition and Spectroscopy Software

Product tags: VIS, Spectral Data, Color Temperature, CRI, Bilirubin, PAR, Scotopic, Luminous Color, Photometry, General lighting

Current and Future Realizations NRC Photometric and Spectroradiometric Calibration Chains

Chameleon Spectroradiometer

Multispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2

Solid State Luminance Standards

QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers

HR2000+ Spectrometer. User-Configured for Flexibility. now with. Spectrometers

Application Note (A16)

Program for UV Intercomparison 2014 in Davos:

LED Tester BTS256-LED

GHOLOGRAPHIC COMPANY LIGHT MEASUREMENT SYSTEM

operating manual iliad for Windows & Mac OS X software application rc81

Agilent Cary 7000 Universal Measurement Spectrophotometer (UMS)

Spectroradiometer characterisations for traceable solar radiation measurements

High Precision CCD Spectroradiometer & Integrating Sphere Test System LPCE-2(LMS-9000B) Brochure. Global Office of Lisun Electronics Inc.

Influence of the light spectral distribution used in the radiometers calibration

CAS 120. CCD Array Spectrometer. Two Global Leaders. One Complete Solution.

Spectral Analysis of the LUND/DMI Earthshine Telescope and Filters

Radiometric Measurement Traceability Paths for Photovoltaic Calibrations. Howard W. Yoon Physical Measurement Laboratory NIST

SPECTRAL SCANNER. Recycling

The PMOD/WRC Precision Spectroradiometer PSR

VS7550 VUV/UV Mini Spectrograph Operating Manual

Overview Full Featured Silicon Photomultiplier Module for OEM and Research Applications The is a solid state alternative to the Photomultiplier Tube (

OL Series 426 Low Light Level lntegrating Sphere Calibration Standards

ROTATING SHADOWBAND SPECTRORADIOMETER MODEL RSS-1024/UVRSS-1024 BULLETIN RSS/UVRSS-1024

A stray light corrected array spectroradiometer for complex high dynamic range measurements in the UV spectral range.

UV-LED radiation source (ULS)

Keysight Technologies Optical Power Meter Head Special Calibrations. Brochure

SOLARONIX. Solixon A-1525-V

A dual-field-of-view spectrometer system for reflectance and fluorescence measurement

IBIL setup operation manual for SynerJY software version

CAS 140D. Array spectrometer for high accuracy light measurement. We bring quality to light.

WHITE PAPER. Guide to CCD-Based Imaging Colorimeters

Thermo Scientific SPECTRONIC 200 Visible Spectrophotometer. The perfect tool. for routine measurements

Camera Requirements For Precision Agriculture

Page 1 BIOIMAGER. Spectrophotometers. Toll Free: (855) BIO- IMAG / (855) , E: S:

Lab Junior Educational UV-VIS Spectrometer

Quality Manual of Luminous Flux Measurements

OtO Photonics. Light Source Datasheet. Description. Balance Light Series LS-BA. Halogen Light Series LS-HA

UM1380/ UM2380 UM1390/ UM2390 Datasheet

illumia Plus Temperature Controlled Light Measurement Systems

pco.1300 solar cooled digital 12bit CCD camera system

CAS 140D. Array spectrometer for high accuracy light measurement. We bring quality to light.

Thermo Scientific SPECTRONIC 200 Visible Spectrophotometer. The perfect. teaching instrument

Dual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE

LEADING THE WAY in Light Measurement Systems

Camera Requirements For Precision Agriculture

Experimental Analysis of Luminescence in Printed Materials

11Beamage-3. CMOS Beam Profiling Cameras

DV420 SPECTROSCOPY. issue 2 rev 1 page 1 of 5m. associated with LN2

UV / VIS Spectrophotometer EMCLAB Instruments GmbH

A dual-field-of-view spectrometer system for reflectance and fluorescence measurement

Using DIAGNOSE.EXE with a ColorQuest 45/0

T92+ UV-VIS SPECTROPHOTOMETER

2008 Stray Light Correction Work

Developement of the method for realization of spectral irradiance scale featuring system of

Thermo Scientific SPECTRONIC 200 Education

Quantitative Estimation of Vvariability in the Underwater Radiance Distribution (RadCam)

MultiCam A Multi-Spectral Imager for Airborne, Laboratory and Field Applications Instruction Manual

Spark Spectral Sensor Offers Advantages

Thermo Scientific SPECTRONIC 200

Upgrade to Andor s high-resolution Luca EM R EMCCD; the new price/performance benchmark.

MK350 Portable Spectrometer

Vernier SpectroVis Plus Spectrophotometer (Order Code: SVIS-PL)

product overview pco.edge family the most versatile scmos camera portfolio on the market pioneer in scmos image sensor technology

Sabeeh Irfan Ahmad, Physlab, 23 July 2016

Camera Calibration Certificate No: DMC III 27542

Transcription:

Aalto University School of Electrical Engineering Metrology Research Institute Hans Baumgartner Instruction manual for Version 1.0 24/11/2016

Page 2 (9) 1. Table of contents 1. Table of contents... 2 2. Overview... 3 3. Measurement instructions... 4 3.1. Powering up the instrument and warm-up... 4 4. Calibration instructions... 5 4.1. Level calibration... 5 4.1.1. QE65 Pro... 5 4.1.2. USB4000... 6 4.1.3. Calibration analysis Excel... 7 4.2. Wavelength calibration... 8 References... 9

Page 3 (9) 2. Overview QE65 Pro (Figure 1) are array spectroradiometers that can be used in various photometric, colorimetric and radiometric measurements. The wavelength range for the USB4000 spectroradiometer is 116.59 884.65 nm and the CCD array consists of 3648 elements, leading to a wavelength interval of about 0.2 nm. For the QE65 Pro spectroradiometer, the wavelength range is 301.42 1088.22 nm divided into 1044 pixels leading to a wavelength interval of 0.79 nm. The sensor of the QE65 Pro instrument is Peltier-cooled to improve the signal-to-noise ratio. The sensor of the USB4000 device is not temperature controlled. Figure 1:.

Page 4 (9) 3. Measurement instructions Both spectroradiometers, USB4000 and QE65 Pro, are operated using SpectraSuite software. Instrument drivers are installed at the same time with the operating software. Basic use of SpectraSuite software is straight forward. The attached instrument is recognized by the software at startup. The device starts measuring automatically after starting SpectraSuite. Below is a step-by-step guide to start measuring with the instrument: 1. Turn on the instrument (warm-up time of 20 minutes or more is required). 2. Connect the instrument to the computer. 3. Open SpectraSuite software. The device starts measuring automatically. 4. Choose the integration time, averaging, and the wanted error correction options. 5. The device is measuring continuously; wait for the measurement to be finished. 6. Save the measurement data. 3.1. Powering up the instrument and warm-up The electronics of the Ocean Optics spectroradiometers are powered through the USB ports of the devices. In addition, QE65 Pro model includes a separate power plug and power supply unit for the TEC cooler of the CCD cell array. Only the dedicated Ocean Optics AC power adapter (model PW160) should be used to power up the instrument.

Page 5 (9) 4. Calibration instructions The Ocean Optics spectroradiometers are calibrated for irradiance by carrying out the required measurements using SpectraSuite software and making a dedicated calibration Excel file. The calibration Excel file for the QE65 Pro spectroradiometer should be named as qe_calib_yyyymmdd.xlsx, where yyyy, mm, and dd are the year, month, and day of the calibration, respectively. For the USB4000 spectroradiometer, the calibration Excel file should be named as usb4000_calib_yyyymmdd.xlsx. The created calibration Excel file is used to correct the raw measurement data. The device has a factory calibrated wavelength scale and a correction for the nonlinearity. This manual do not cover the calibration of the wavelength scale or the nonlinearity. 4.1. Level calibration 4.1.1. QE65 Pro The QE65 Pro spectroradiometer is calibrated against a FEL lamp in the optical rail laboratory. The calibration distance is 500 mm and a shutter is used between the lamp and the diffuser head of the spectroradiometer. The diameter of the shutter aperture should be set to 50 mm. The measurement parameters for calibrating the device are as follows: Integration time: 1 s Scans to average: 10 Boxcar width: 0 Several corrections can be applied for the device measurement data; electric dark, nonlinearity, and stray light corrections. The calibration should be carried out for every correction combination separately. For the most convenient and fast way of calibrating and using the device is to use only electric dark and nonlinearity corrections. However, the corrections required depend on your application. Figure 1 shows a screenshot of the SpectraSuite software with the typical calibration measurement settings.

Page 6 (9) Figure 2: Ocean Optics SpectraSuite software is used to control the QE65 Pro spectroradiometer. The calibration is carried out by first measuring the dark signal of the device with the 50 mm shutter closed. After the dark signal measurement, the shutter is opened and the reference light signal measured. Before saving the data, the spectroradiometer data needs to be allowed to stabilize at least 1 minute. When saving the data, a tab delimited text file with headers should be chosen as the saving format. 4.1.2. USB4000 The USB4000 spectroradiometer is calibrated against a FEL lamp in the optical rail laboratory. The calibration distance is 500 mm and a shutter is used between the lamp and the diffuser head of the spectroradiometer. The diameter of the shutter aperture is 50 mm. The measurement parameters for calibrating the device are as follows: Integration time: 200 ms Scans to average: 10 Boxcar width: 0 Several corrections can be applied for the device measurement data; electric dark, nonlinearity, and stray light corrections. The calibration should be carried out for every correction combination separately. For the most convenient and fast way of calibrating and using the device is to use only electric dark and nonlinearity corrections. However, the corrections required depend on your application. Figure 3 shows a screenshot of the SpectraSuite software with the typical calibration measurement settings.

Page 7 (9) Figure 3: Ocean Optics SpectraSuite software is used to control the USB4000 spectroratiometer. The calibration is carried out by first measuring the dark signal of the device with the 50 mm shutter closed. After the dark signal measurement, the shutter is opened and the reference light signal measured. Before saving the data, the spectroradiometer data needs to be allowed to stabilize at least 1 minute. When saving the data, a tab delimited text file with headers should be chosen as the saving format. 4.1.3. Calibration analysis Excel The calibration measurement files are analyzed using a calibration Excel file. The first sheet of the Excel file includes the calibration data of the FEL lamp used in the calibration measurements. The FEL calibration data can be found from the calibration certificate of the lamp. The spectroradiometer calibration measurement data will be added to the second sheet of the Excel file, called QE calib. The dark measurement of the FEL lamp will be added to the column named Dark. The lamp spectrum measurement will be added to the column named FEL-460 measurement. The calibration coefficients are calculated to the column Calib. After calibration, the Correction sheet of the calibration Excel can be used to correct the measured spectrum for absolute irradiance. The sheet named 360-830 interpolates the data of the Correction sheet for the wavelength range between 360 and 830 nanometers using a wavelength interval of 1 nm.

Page 8 (9) 4.2. Wavelength calibration The wavelength calibration of the Ocean Optics spectroradiometers has not been tested.

Page 9 (9) References