Nature Methods: doi: /nmeth Supplementary Figure 1. Schematic of 2P-ISIM AO optical setup.

Similar documents
Rapid Adaptive Optical Recovery of Optimal Resolution over Large Volumes

Nature Methods: doi: /nmeth Supplementary Figure 1

Aberrations and adaptive optics for biomedical microscopes

Nature Neuroscience: doi: /nn Supplementary Figure 1. Optimized Bessel foci for in vivo volume imaging.

Shaping light in microscopy:

Instant super-resolution imaging in live cells and embryos via analog image processing

Fast, high-contrast imaging of animal development with scanned light sheet based structured-illumination microscopy

Point Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy

LSM 710 Confocal Microscope Standard Operation Protocol

Why and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev. Microscopy course, Michmoret Dec 2005

Optical Components for Laser Applications. Günter Toesko - Laserseminar BLZ im Dezember

Rapid Non linear Image Scanning Microscopy, Supplementary Notes

2. Adaptive Optical Microscopy using Direct Wavefront Sensing 2.1 Introduction In this chapter we will review adaptive optics (AO) in biological

Supplementary Information. Stochastic Optical Reconstruction Microscopy Imaging of Microtubule Arrays in Intact Arabidopsis thaliana Seedling Roots

WaveMaster IOL. Fast and accurate intraocular lens tester

Spectral Imaging with the Opterra Multipoint Scanning Confocal

Martin J. Booth, Delphine Débarre and Alexander Jesacher. Adaptive Optics for

WaveMaster IOL. Fast and Accurate Intraocular Lens Tester

Confocal Imaging Through Scattering Media with a Volume Holographic Filter

SUPPLEMENTARY INFORMATION

LSM 780 Confocal Microscope Standard Operation Protocol

Nikon Instruments Europe

Life Science Instrumentation. New Generation. Light Sheet Fluorescence Microscope. Alph

Adaptive optics two-photon fluorescence microscopy

Examination, TEN1, in courses SK2500/SK2501, Physics of Biomedical Microscopy,

ANSWER KEY Lab 2 (IGB): Bright Field and Fluorescence Optical Microscopy and Sectioning

a) How big will that physical image of the cells be your camera sensor?

Flatness of Dichroic Beamsplitters Affects Focus and Image Quality

Reference and User Manual May, 2015 revision - 3

Advanced Optical Microscopy lecture. 03. December 2012 Kai Wicker

Practical Flatness Tech Note

Supplementary Information for. Surface Waves. Angelo Angelini, Elsie Barakat, Peter Munzert, Luca Boarino, Natascia De Leo,

Explanation of Aberration and Wavefront

A broadband achromatic metalens for focusing and imaging in the visible

1 Co Localization and Working flow with the lsm700

Technology Note ZEISS LSM 880 with Airyscan

FLUORESCENCE MICROSCOPY. Matyas Molnar and Dirk Pacholsky

Boulevard du Temple Daguerrotype (Paris,1838) a busy street? Nyquist sampling for movement

Multifluorescence The Crosstalk Problem and Its Solution

CHARA AO Calibration Process

Supplementary Materials

Development of a High-speed Super-resolution Confocal Scanner

3D light microscopy techniques

Basics of confocal imaging (part I)

Practical work no. 3: Confocal Live Cell Microscopy

The DCS-120 Confocal Scanning FLIM System

Supplemental Figure 1: Histogram of 63x Objective Lens z axis Calculated Resolutions. Results from the MetroloJ z axis fits for 5 beads from each

Nature Structural & Molecular Biology: doi: /nsmb Supplementary Figure 1

Microscopy. Lecture 2: Optical System of the Microscopy II Herbert Gross. Winter term

D2.1 Operating 2D STED Microscope

Reflecting optical system to increase signal intensity. in confocal microscopy

Ron Liu OPTI521-Introductory Optomechanical Engineering December 7, 2009

Final Exam, 150 points PMB 185: Techniques in Light Microscopy

Lecture 2: Geometrical Optics. Geometrical Approximation. Lenses. Mirrors. Optical Systems. Images and Pupils. Aberrations.

Nature Methods: doi: /nmeth Supplementary Figure 1. sospim principle and representation of the sospim beam-steering unit.

Leica Sp5 II Confocal User Guide

Multicolor 4D Fluorescence Microscopy using Ultrathin Bessel Light sheets

Chapter 25. Optical Instruments

Supplementary Figure S1. Schematic representation of different functionalities that could be

Proposed Adaptive Optics system for Vainu Bappu Telescope

Zeiss LSM 880 Protocol

Multi-channel imaging cytometry with a single detector

Leica TCS SP8 Quick Start Guide

Invitation for a walk through microscopy. Sebastian Schuchmann Jörg Rösner

Maria Smedh, Centre for Cellular Imaging. Maria Smedh, Centre for Cellular Imaging

Things to check before start-up.

OPAL. SpotOptics. AUTOMATED WAVEFRONT SENSOR Single and double pass O P A L

Leica SP8 Resonant Confocal. Quick-Start Guide

Lecture 2: Geometrical Optics. Geometrical Approximation. Lenses. Mirrors. Optical Systems. Images and Pupils. Aberrations.

Travel to New Dimensions- LSM 880. The Resolution of a Microscope is limited. The Resolution of a Microscope is limited. Image. Image. Object.

High contrast imaging lab

CCAM Microscope Objectives

Better Imaging with a Schmidt-Czerny-Turner Spectrograph

Opterra II Multipoint Scanning Confocal Microscope. Innovation with Integrity

Training Guide for Leica SP8 Confocal/Multiphoton Microscope

Quick Start Guide. Leica SP5 X

Lecture 4: Geometrical Optics 2. Optical Systems. Images and Pupils. Rays. Wavefronts. Aberrations. Outline

Resolution. Diffraction from apertures limits resolution. Rayleigh criterion θ Rayleigh = 1.22 λ/d 1 peak at 2 nd minimum. θ f D

Adaptive Optical Microscopy Using Direct Wavefront Measurements

Dynamic closed-loop system for focus tracking using a spatial light modulator and a deformable membrane mirror

Akinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report. Introduction and Background

Supplementary information, Figure S1A-S1H The thickness and the uniformity of the light sheet at different DOFs. By

Deep and fast live imaging with two-photon scanned light-sheet microscopy

Leica TCS SP8 Quick Start Guide

Lecture 16. OMX - Structured Illumination Microscopy Ian Dobbie x Microscopy Course Lecture 16 1

Breadboard adaptive optical system based on 109-channel PDM: technical passport

Rates of excitation, emission, ISC

INTRODUCTION TO OPTICAL MICROSCOPY

Beam Profiling. Introduction. What is Beam Profiling? by Michael Scaggs. Haas Laser Technologies, Inc.

1.The Problem LIGHT-LEVEL LEVEL IMAGING. light-level level Cameras. 3. Solutions. 2. Low-light LOW-LIGHT

BASICS OF CONFOCAL IMAGING (PART I)

Adaptive Optics for LIGO

Development of a Low-order Adaptive Optics System at Udaipur Solar Observatory

Non-Descanned FLIM Detection in Multiphoton Microscopes

Fundamentals of Light Microscopy II: Fluorescence, Deconvolution, Confocal, Multiphoton, Spectral microscopy. Integrated Microscopy Course

Bandpass Edge Dichroic Notch & More

Imaging Beyond the Basics: Optimizing Settings on the Leica SP8 Confocal

Bio 407. Applied microscopy. Introduction into light microscopy. José María Mateos. Center for Microscopy and Image Analysis

Wavefront Sensing In Other Disciplines. 15 February 2003 Jerry Nelson, UCSC Wavefront Congress

Imaging Introduction. September 24, 2010

Transcription:

Supplementary Figure 1 Schematic of 2P-ISIM AO optical setup. Excitation from a femtosecond laser is passed through intensity control and shuttering optics (1/2 λ wave plate, polarizing beam splitting cube, and electro-optic modulator, EOM), spatially filtered (pinhole, 100 µm diameter), beam expanded 5-fold (lens pair L1 and L2, f1 = 40 mm, f2 = 200 mm; and iris) and directed onto a 2D galvanometric mirror (excitation scanner). The point between each galvo surface is made conjugate to a deformable mirror, via lens pair L3 and L4 (f3, f4 = 250 mm). Lens pair L5 and L6 (f5, f6 = 200 mm) images the deformable mirror onto the back focal plane of a 1.2 NA water objective, thereby creating diffraction limited excitation at the sample. Fluorescence is collected along the same path until a dichroic mirror, placed between the excitation scanner and L3, diverts it onto a second 2D galvanometric mirror (emission scanner). Lens pair L4 and L3 images the back focal plane of the objective onto this scanner, which serves to rescan fluorescence emission before imaging onto an electron multiplying CCD (EM-CCD) via lens L7 (f7 = 250 mm), enabling super-resolution imaging. Alternatively, for wavefront measurement, the emission scanner is set to descan the fluorescence, and a flip mirror directs this descanned signal onto a Shack Hartmann sensor. Lens pair L8 and L9 (f8 = 250 mm, f9 = 100 mm) serve to image the point between galvo surfaces in the emission scanner onto the Shack Hartman sensor, thus mapping the back focal plane of the objective onto this sensor. Note that lens pairs L1 and L2; L3 and L4; L5 and L6; and L8 and L9 are placed in 4f imaging configurations, thereby ensuring that the back focal plane of the objective, galvanometric scanners, and deformable mirror are conjugate planes. Filters F1 and F2 serve to reject excitation from reaching the EM-CCD and SHS, respectively. See Methods, Supplementary Table 2 for more detail.

Supplementary Figure 2 AO improves performance of 2P-ISIM in aberrated phantom samples. a) 200 nm yellow green fluorescent beads were placed within the inner surface of a curved coverslip and imaged without b) and with c) AO correction, and d) subsequently deconvolved. Lateral (top) and axial (bottom) views are shown, as are corresponding wavefront maps (root-mean square, RMS, wavefront error 0.222 µm before AO correction (c), 0.030 µm after AO, (d)). e) Lateral (top) and axial (bottom) line profiles as indicated in b-c) indicate a 40-fold increase in peak signal (note that profiles without AO have been magnified 10-fold for clarity). See also Supplementary Fig. 4. For a second test, we embedded 100 nm (small circles) and 1 µm (larger circles) yellow green fluorescent beads within a polyacrylamide gel f). 1 µm beads were used for AO correction due to their strong fluorescence signal, and the nearby 100 nm beads were used for system resolution measurement. Lateral (h) and axial (i) images through representative beads at indicated depth alternately show images without (odd images) and with (even images) AO correction and subsequent deconvolution. Spherical aberration (g) due to the refractive index mismatch increases with depth, and is mitigated using AO at all depths, see also Supplementary Fig. 5. Scale bars: 0.5 µm.

Supplementary Figure 3 Estimating system resolution at coverslip surface in AO-2P ISIM. a) Exemplary images of 100 nm yellow-green fluorescence beads on coverslip surface, as viewed in lateral (top) and axial (bottom) cuts through the image stacks. From left to right: two-photon wide-field (non-rescan) image, two-photon wide field image after deconvolution, two-photon ISIM image (i.e. after rescanning), two-photon ISIM image after deconvolution. System aberrations were corrected by measuring the wavefront distortion using a Shack-Hartmann sensor, and subsequently compensating for the aberrated wavefront by using a deformable mirror. b) Modulation transfer functions corresponding to a). c) Comparative line-profiles through the center of each lateral (left) and axial (right) bead image further emphasize improvement after deconvolution. (d) Statistical comparison of estimated lateral (left) and axial (right) resolution (FWHM of bead image), derived from > 30 beads. Means and standard deviations are shown. Scale bars: 0.5 µm.

Supplementary Figure 4 Correcting aberrations through a curved glass surface with AO-2P ISIM. a) Raw (left) and AO-corrected (right) 2P-ISIM images of a 200 nm bead at the curved surface. b) Corresponding images of wavefront measured by Shack-Hartmann sensor. RMS wavefront error is 0.222 µm without AO, and 0.030 µm with AO. c) Decomposition of wavefront into aberration modes (representative Zernike modes shown at right), indicating substantial astigmatism and coma. See also Supplementary Fig. 2. Scale bars: 0.5 µm.

Supplementary Figure 5 Correcting aberrations through a polyacrylamide gel. a) 2P ISIM fluorescence (pre-ao correction) image measured at depth of 200 µm above the coverslip. The strong fluorescence from 1 µm beads (arrowhead) was used for AO correction and the nearby 100 nm beads (arrows) were used for resolution assessment. b) Decomposition of wavefront into Zernike aberration modes, indicating substantial spherical aberration due to refractive index mismatch. Aberration modes are color-coded according to depth in polyacrylamide gel. c) Representative lateral slices (top) and corresponding wavefront maps (bottom) through 100 nm yellow green beads 50 µm into gel, indicating apparent size of bead without (left) and with (right) correction. No deconvolution was applied. d) Intensity line profiles as indicated in c). Note ~2x increase in peak intensity. e) Statistical comparison of relative peak intensity increase after AO correction at indicated depth in the sample. Data are derived from 10 beads. Means and standard deviations are shown. See also Fig. 2. Scale bars: 2 µm in a), 0.5 µm in c).

Supplementary Figure 6 AO improves 2P ISIM imaging at depth in Drosophila tissue. a) Schematic of brain lobe, square indicates imaging region. Comparative images at indicated depth (rows), showing 2P excitation, no rescan (b); raw 2P ISIM (c); raw 2P ISIM with AO correction (d); 2P ISIM deconvolved after AO correction (e). (f) Wavefronts are shown before (left column) and after (right column) aberration correction; root mean square (RMS) values are also indicated. See also Fig. 1, Supplementary Video 1. Scale bars: 5 µm.

Supplementary Figure 7 2P ISIM images of Zygnema algae. Before (a) and after (b) wavefront correction. Autofluorescence from the sample was used to derive wavefronts in each case, which are shown to the right of each image (RMS and peak-to-valley values are also shown). Images were acquired 7 µm into the stack (the largest algal cross-section in our imaging field) and ~50 µm from the coverslip. Scale bar: 5 µm.

Supplementary Figure 8 Fiducial-based AO Correction in live biological samples, as demonstrated in larval nematodes expressing GFP. Neural structures were tagged with GFP in larval nematodes and imaged without rescan (a, no AO; d, with AO), with rescan (b, without AO; e, with AO) and with rescan and followed by deconvolution (c). The best resolution and contrast are obtained in (c). Lateral (upper) and axial maximum intensity projections are shown. The field of view was chosen near the head of the animal as indicated by red box in schematic f). Comparative wavefronts before and after AO correction are shown in (g); wavefronts were derived by scanning the beam over the neuron marked with red asterisk in (c). In this sample, the cell body region marked in (c) was used for AO. Scale bars: 5 µm.

Supplementary Figure 9 Fiducial-based AO correction improves 2P ISIM imaging of microtubule bundles in fixed cells embedded in a 3D matrix, at depths exceeding 200 µm from the coverslip surface. Results without (a, d) and with (b, e) AO correction and subsequent deconvolution. The latter images show obvious improvements in spatial resolution and contrast (compare insets in a, b) and signal (line profiles in c, corresponding to red/green lines indicated in a, b. Representative images are shown 50 µm (a, b) and 230 µm (d, e) from the coverslip. From the MTFs (see Methods for details on calculations), we estimate that AO improves the lateral resolution from 0.45 µm (a) to 0.20 µm (b) and the axial resolution from 1.50 µm (a) to 0.55 µm (b) 50 µm from the coverslip. AO improved lateral resolution from 1.05 µm (d) to 0.33 µm (e) and axial resolution from 2.34 µm (d) to 0.65 µm (e) 230 µm from the coverslip. Images (d, e) also show the fluorescent bead (red asterisk in d) used for correction; note that image contrast has been adjusted to show the much fainter signal in the biological sample, which is why bead appears saturated. Comparative wavefronts corresponding to (d, e) are shown in (f). All images are maximum intensity projections. Scale bars: 5 µm.

Supplementary Figure 10 Dye-based AO improves 2P-ISIM imaging in somites (b-e) and neural tube (g-h) of live embryonic zebrafish at 30-32 hpf. a) Schematic of embryo, indicating imaging region (higher magnification view). Selected imaging fields at indicated axial depth are shown, before (b, d, g) and after (c, e, h) AO correction and subsequent deconvolution. Comparative wavefronts are also shown as inset. f) Indicates spectral bandwidth used for AO correction with CellTracker Orange and 2P-ISIM imaging. See also Fig. 3. Scale bar: 10 µm.

Supplementary Figure 11 Dye-based AO improves 2P-ISIM imaging of gastrocnemius muscle of excised mouse leg. Rhodamine phalloidin was used to stain actin fibers within the muscle leg and CellTracker Green was added for AO correction. a) Graph indicates spectral region used for AO correction vs. imaging. Selected image slices through two gastrocnemius muscle fibers of differing contractility before (b, e, h, k) and after (c, f, i, l) AO and deconvolution. Normalized line profiles (40 pixels in width) corresponding to red/black lines indicated in each depth are shown in (d, g, j). Higher magnification views of dashed yellow rectangular regions are shown, as are wavefronts (insets). Scale bars: 5 µm for zoomed-out panels, 2 µm for higher magnification views.

Supplementary Figure 12 Dye-based AO improves 2P-ISIM imaging of presumed gut granules in live larval C. elegans. a) Schematic of larvae, indicating approximate region (higher magnification views) used in imaging. Worms were incubated overnight with CellTracker Orange mixed with OP50 prior to imaging. The 400 nm-700 nm spectral region was used for AO correction. Imaging was performed before (b, d, f, h, j) and after (c, e, g, i, k, all with subsequent deconvolution) AO, using a 525/70 bandpass emission filter. Scale bar in brightfield transmission image: 100 µm; in fluorescence images: 10 µm.

Supplementary Table 1, Adaptive recovery of resolution at progressively increasing distances from the coverslip (aberrations increase with distance). Lateral system -50 µm -100 µm -150 µm -200 µm -250 µm resolution (0 µm, at coverslip) 2P WF AO off 300 ± 23 nm 328 ± 24 nm 350 ± 33 nm 2P WF AO on 260±22 nm 267 ± 11 nm 287 ± 25 nm 313 ± 27 nm 2P WF AO on + decon 186±17 nm 161 ± 9 nm 183 ± 18 nm 219 ± 19 nm 2P ISIM AO off 249 ± 19 nm 270 ± 11 nm 272 ± 35 nm 290 ± 13 nm 302 ± 26 nm 2P ISIM AO on 212 ± 27 nm 228 ± 7 nm 229 ± 7 nm 229 ± 9 nm 238 ± 11 nm 259 ± 17 nm 2P ISIM AO on + decon 140 ± 20 nm 142 ± 7 nm 142 ± 5 nm 146 ± 7 nm 151 ± 8 nm 176 ± 10 nm Axial system -50 µm -100 µm -150 µm -200 µm -250 µm resolution (0 µm, at coverslip 2P WF AO off 1047 ± 82 nm 1351 ± 99 nm 1686 ± 163 nm 2P WF AO on 611±32 nm 684 ± 34 nm 799 ± 36 nm 1029 ± 49 nm 2P WF AO on + decon 383±27 nm 389 ± 16 nm 497 ± 42 nm 664 ± 35 nm 2P ISIM AO off 966 ± 81 nm 1120 ± 37 nm 1274 ± 63 nm 1397 ± 83 nm 1616 ± 112 nm 2P ISIM AO on 629±67 nm 695 ± 15 nm 788 ± 41 nm 887 ± 42 nm 943 ± 40 nm 1032 ± 45 nm 2P ISIM AO on + decon 390±43 nm 439 ± 16 nm 513 ± 30 nm 594 ± 27 nm 623 ± 33 nm 729 ± 39 nm 100 nm fluorescent beads were placed in a polyacrylamide gel and imaged as indicated (left column) at indicated depth. In all cases, AO correction (using nonlinear-excitation induced signal derived from 1 µm fluorescent beads) improved lateral and axial resolution, as indicated by FWHM values measured from 100 nm beads. At least 10 beads were used for measurements. 1

Supplementary Table 2, Acquisition parameters and fluorescence filters used in this work. Sample Figure/Vide o Excitation Wavelength, nm 2P-ISIM Imaging, F1 Wavefront Sensing, F2 Frame Acquisitio n, s Frame Average Axial nm Step, Number planes of Volume Imaging Time, s Beads Cells in gel Zygnema algae Drosophila larval brain Zebrafish embryos Nematode embryos S2a,S3,S4 900 FF01-720/SP FF01-720/SP 0.5 10 100 45 240 S2b,S5 900 FF01-720/SP FF01-720/SP 0.5 10 100 40 210 2, Video 3 830 FF01-720/SP FF01-720/SP 0.5 5 300 50 140 S9 930 FF01-720/SP FF01-720/SP 0.5 5 300 50 140 S7 900 FF01-720/SP FF01-720/SP 0.5 5 500 15 60 1, S6, Video 1 3, S10, Video 4 Video 2 930 930 FF01-520/70-25 FF01-720/SP 0.5 5 500 150 700 900 FF01-520/70-25 FF01-720/SP 0.5 5 1000 70 280 FF01-720/SP FF01-520/70 & FF01-720/SP 0.5 1 1000 30 20 Larval nematodes S8 900 FF01-720/SP FF01-720/SP 0.5 5 300 40 110 S12 850 Mouse leg S11 870 FF01-720/SP & FF01-520/70-25 FF01-720/SP & FF562-Di03-25x36 FF01-720/SP 0.5 5 300 65 260 FF01-720/SP 0.5 5 1000 60 240 Frame Average: the number of raw frames averaged to produce a single image; Axial Step: the axial step size between planes; Number of planes: the total number of planes in a 3D volume; Volume Imaging Time: total time for acquiring a 3D volume, including imaging, frame averaging, wavefront measurement, and instrument overhead (~0.5 s, including flipping mirror, moving piezoelectric stage). All fluorescence filters are from Semrock; F1 and F2 refer to Supplementary Fig. 1. 2