MODIFIED CONTROL STRATEGY OF CASCADED H- BRIDGE MULTILEVEL CONVERTER IN GRID CONNECTED WIND ENERGY SYSTEM

Similar documents
A SPWM CONTROLLED THREE-PHASE UPS FOR NONLINEAR LOADS

29 Level H- Bridge VSC for HVDC Application

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

A New Single-Phase Multilevel Inverter with Reduced Number of Switches for Solar Applications

CAPACITOR VOLTAGE BALANCING IN SINGLE PHASE SEVEN-LEVEL PWM INVERTER

Bhanutej Jawabu Naveez Assistant Professor, Vignana Bharathi Institute of Technology, Aushapur, Ghatkesar, Hyderabad.

SIMULATION, DESIGN AND CONTROL OF A MODIFIED H-BRIDGE SINGLE PHASE SEVEN LEVEL INVERTER 1 Atulkumar Verma, 2 Prof. Mrs.

A Five Level Inverter for Grid Connected PV System Employing Fuzzy Controller

A New Multilevel Inverter Topology with Reduced Number of Power Switches

Original Article Development of multi carrier PWM technique for five level voltage source inverter

A Novel Cascaded Multilevel Inverter Using A Single DC Source

Analysis and Simulation of Multilevel DC-link Inverter Topology using Series-Parallel Switches

Simulation of Cascade H-Bridge Multilevel Inverter With Equal DC Voltage Source

Modified Hybrid Multilevel Inverter for Induction Motor Using Solar energy

Modified Multilevel Inverter Topology for Driving a Single Phase Induction Motor

Australian Journal of Basic and Applied Sciences. Simulation and Analysis of Closed loop Control of Multilevel Inverter fed AC Drives

Phase Shift Modulation of a Single Dc Source Cascaded H-Bridge Multilevel Inverter for Capacitor Voltage Regulation with Equal Power Distribution

A NEW TOPOLOGY OF CASCADED MULTILEVEL INVERTER WITH SINGLE DC SOURCE

Simulation and Experimental Results of 7-Level Inverter System

A COMPARITIVE STUDY OF THREE LEVEL INVERTER USING VARIOUS TOPOLOGIES

Srinivas Dasam *, Dr. B.V.Sanker Ram **,A Lakshmisudha***

Reduction of Harmonics and Torque Ripples of BLDC Motor by Cascaded H-Bridge Multi Level Inverter Using Current and Speed Control Techniques

Harmonic Reduction in Induction Motor: Multilevel Inverter

PSPWM Control Strategy and SRF Method of Cascaded H-Bridge MLI based DSTATCOM for Enhancement of Power Quality

Design of DC AC Cascaded H-Bridge Multilevel Inverter for Hybrid Electric Vehicles Using SIMULINK/MATLAB

A Comparative Study of Different Topologies of Multilevel Inverters

Multilevel Inverter Based Statcom For Power System Load Balancing System

Reduction in Total Harmonic Distortion Using Multilevel Inverters

COMPARATIVE STUDY OF DIFFERENT TOPOLOGIES OF FIVE LEVEL INVERTER FOR HARMONICS REDUCTION

Generating 17 Voltage Levels Using a Three Level Flying Capacitor Inverter and Cascaded Hbridge

A Hybrid Cascaded Multilevel Inverter for Interfacing with Renewable Energy Resources

Enhanced Performance of Multilevel Inverter Fed Induction Motor Drive

THE greatest drawback of modular multilevel topologies,

Three Phase Parallel Multilevel Inverter Fed Induction Motor Using POD Modulation Scheme

MMC based D-STATCOM for Different Loading Conditions

ISSN Vol.03,Issue.22 September-2014, Pages:

Single Phase Bidirectional PWM Converter for Microgrid System

A NOVEL APPROACH TO ENHANCE THE POWER QUALITY USING CMLI BASED CUSTOM POWER DEVICES

Literature Survey: Multilevel Voltage Source Inverter With Optimized Convention Of Bidirectional Switches

CARRIER BASED PWM TECHNIQUE FOR HARMONIC REDUCTION IN CASCADED MULTILEVEL INVERTERS

Nine-Level Cascaded H-Bridge Multilevel Inverter Divya Subramanian, Rebiya Rasheed

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 03 Issue: 11 Nov p-issn:

PF and THD Measurement for Power Electronic Converter

ADVANCES in NATURAL and APPLIED SCIENCES

Keywords Cascaded Multilevel Inverter, Insulated Gate Bipolar Transistor, Pulse Width Modulation, Total Harmonic Distortion.

Modeling of Single Stage Grid-Connected Buck-Boost Inverter for Domestic Applications Maruthi Banakar 1 Mrs. Ramya N 2

Comparative Analysis of Control Strategies for Modular Multilevel Converters

Hybrid PWM switching scheme for a three level neutral point clamped inverter

A Single Phase Multistring Seven Level Inverter for Grid Connected PV System

Multilevel Inverter with Coupled Inductors with Sine PWM Techniques

Simulation of Single Phase Multilevel Inverters with Simple Control Strategy Using MATLAB

A NOVEL SWITCHING PATTERN OF CASCADED MULTILEVEL INVERTERS FED BLDC DRIVE USING DIFFERENT MODULATION SCHEMES

Speed Control of Induction Motor using Multilevel Inverter

International Journal of Advance Engineering and Research Development

COMPARATIVE STUDY ON CARRIER OVERLAPPING PWM STRATEGIES FOR THREE PHASE FIVE LEVEL DIODE CLAMPED AND CASCADED INVERTERS

IJCSIET--International Journal of Computer Science information and Engg., Technologies ISSN

Analysis of IM Fed by Multi-Carrier SPWM and Low Switching Frequency Mixed CMLI

Published by: PIONEER RESEARCH & DEVELOPMENT GROUP(

MODELLING AND SIMULATION OF DIODE CLAMP MULTILEVEL INVERTER FED THREE PHASE INDUCTION MOTOR FOR CMV ANALYSIS USING FILTER

A Fifteen Level Cascade H-Bridge Multilevel Inverter Fed Induction Motor Drive with Open End Stator Winding

Simulation of Five-Level Inverter with Sinusoidal PWM Carrier Technique Using MATLAB/Simulink

Hybrid Five-Level Inverter using Switched Capacitor Unit

A Series-Connected Multilevel Inverter Topology for Squirrel-Cage Induction Motor Drive

MATLAB Implementation of a Various Topologies of Multilevel Inverter with Improved THD

Grid Connected Photovoltaic Micro Inverter System using Repetitive Current Control and MPPT for Full and Half Bridge Converters

Power Quality Improvement Using Cascaded Multilevel Statcom with Dc Voltage Control

Simulation of Single Phase Grid Connected Photo Voltaic System Based On PWM Control Of Switched Boost Inverter For DC Nanogrid Applications

Modified Transistor Clamped H-bridge-based Cascaded Multilevel inverter with high reliability.

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 04, 2016 ISSN (online):

SWITCHING FREQUENCY HARMONIC SELECTION FOR SINGLE PHASE MULTILEVEL CASCADED H-BRIDGE INVERTERS

Multilevel Inverter for Grid-Connected PV SystemEmploying MPPT and PI Controller

Hybrid Modulation Technique for Cascaded Multilevel Inverter for High Power and High Quality Applications in Renewable Energy Systems

A Single-Phase Carrier Phase-shifted PWM Multilevel Inverter for 9-level with Reduced Switching Devices

Levels of Inverter by Using Solar Array Generation System

Low Order Harmonic Reduction of Three Phase Multilevel Inverter

A Novel Multilevel Inverter Employing Additive and Subtractive Topology

PERFORMANCE EVALUATION OF MULTILEVEL INVERTER BASED ON TOTAL HARMONIC DISTORTION (THD)

Hybrid Modulation Switching Strategy for Grid Connected Photovoltaic Systems

Reduced PWM Harmonic Distortion for a New Topology of Multilevel Inverters

CHAPTER 3 SINGLE SOURCE MULTILEVEL INVERTER

A New Transistor Clamped 5-Level H-Bridge Multilevel Inverter with voltage Boosting Capacity

Multilevel Inverter for Single Phase System with Reduced Number of Switches

Improving Passive Filter Compensation Performance With Active Techniques

Intelligence Controller for STATCOM Using Cascaded Multilevel Inverter

A THREE PHASE SHUNT ACTIVE POWER FILTER FOR HARMONICS REDUCTION

Simulation and Comparision of Back To Back System using Bidirectional Isolated DC-DC Converter with Active Energy Storage

MLI HYBRID STATCOM WITH WIDE COMPENSATION RANGE AND LOW DC LINK VOLTAGE

A New Network Proposal for Fault-Tolerant HVDC Transmission Systems

Hardware Implementation of SPWM Based Diode Clamped Multilevel Invertr

Voltage Unbalance Elimination in Multilevel Inverter using Coupled Inductor and Feedback Control

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

Performance Analysis of Three Phase Cascaded H-Bridge Multi Level Inverter for Voltage Sag and Voltage Swell Conditions

A Three-Phase AC-AC Buck-Boost Converter using Impedance Network

Current Rebuilding Concept Applied to Boost CCM for PF Correction

A Novel H Bridge based Active inductor as DC link Reactor for ASD Systems

ECEN 613. Rectifier & Inverter Circuits

Performance and Analysis of Hybrid Multilevel Inverter fed Induction Motor Drive

ANALYSIS OF PWM STRATEGIES FOR Z-SOURCE CASCADED MULTILEVEL INVERTER FOR PHOTOVOLTAIC APPLICATIONS

Z-SOURCE INVERTER BASED DVR FOR VOLTAGE SAG/SWELL MITIGATION

Harmonic Reduction in Five Level Inverter Based Dynamic Voltage Restorer

Transcription:

MODIFIED CONTROL STRATEGY OF CASCADED H- BRIDGE MULTILEVEL CONVERTER IN GRID CONNECTED WIND ENERGY SYSTEM M. SATHISH PG. Scholar, Jyothishmathi Institute of Technology & Science, Karimnagar, Telangana. Abstract-- The range of the output power is a very important and evident limitation of two-level inverters. In order to overcome this disadvantage, multilevel inverters are introduced. Recently, Cascade H-Bridge inverters have emerged as one of the popular converter topologies used in numerous industrial applications. In this paper we have discussed about a particular circumstance that the RMS value of the inverter output voltage fluctuates with certain frequency and amplitude. This paper presents the application of this special-outputting cascaded H-bridge (CHB) multilevel converter, gridconnected wind turbine converter testing. In this paper, by comparing with the other control strategies new control strategy is proposed which is simple and effective and also the modeling and analysis of this particular RMS value feedback control strategy is elaborated. Simulation work is done using the MATLAB software and experimental results have been presented to validate the theory. I. INTRODUCTION Now a days industrial applications needs higher power rating which reached to mega watt range. For a medium voltage grid. It is troublesome to connect only one power semiconductor switch directly. As a result, multilevel power converter structure has been introduced as an alternative in high power and medium voltage applications. A multilevel converter not only achieves high power ratings, but also enables the use of renewable energy sources such as photovoltaic, wind, and fuel cells can be easily interfaced to a multilevel converter system for medium voltage high power drives, distributed energy sources and hybrid electric vehicles. The range of output power is limited in two level inverters, this disadvantage is overcome by multilevel inverter and they have features such as high reliability due to its modular topology, less distorted input current and less switching losses. Among the topologies of multilevel inverter Cascade Multilevel Inverter (CMIL) is one of the most important topology because of following features G. SRIDHAR Associate Professor, Jyothishmathi Institute of Technology & Science, Karimnagar, Telangana. such as no specially designed transformer is needed as compared to multi pulse inverter, occupies less space and ability to synthesize better harmonic spectrum. With the advantages over other multilevel converters such as neutral point clamped converter [2] and flying capacitor converter [3], CHB multilevel converters are playing a more and more significant role in power converter family for highpower, high-voltage applications due to comparatively low cost, no need for numerous capacitors and diodes, ease of control, excellent performance and capability of fault tolerant. The major applications of the CHB multilevel converter are VAR compensation, middle-voltage variable speed drive and back-to-back system. Many researchers have contributed to the research of CHB multilevel converters. Nowadays, renewable energy systems are undergoing an important development. Among them wind energy stands out for its installed capacity, power generation steady growth. In this paper based on CHB structure wind turbine testing system control strategy is investigated. A grid connected wind turbine converter testing system. is constructed through the combination of CHB multilevel converter, three-phase PWM converter and transformers as depicted in Fig.1. In order to simulate a 35 kv-power grid and produce a fluctuating voltage whose RMS value fluctuates with certain frequency and amplitude, the control of CHB multilevel inverter should be conscientiously designed provided that the DC-link voltage is permanent and each phase is controlled separately as a single-phase inverter. The combination of three single-phase CHB multilevel inverters constructs a three-phase system in which every single CHB multilevel inverter works as a single-phase inverter. As a corollary to this statement, the control strategy of single-phase inverter can be considered as reference for CHB multilevel converter control. Many control schemes have been proposed during past decades for single-phase inverters, but those control strategies bring about draw backs, for instance, difficulty in modeling, complex design and

hardware implementation, sensitive to system parameters and loading conditions, or simply steady state errors. Moreover, majority of these control strategies ordinarily only concern about the particular types of loads which shrinks the scope of the benefit discovered. Based on the controller structure, applying a single voltage regulator is enough for the control of single-phase inverter AC voltage, but this is not enough when dealing with more demanding applications with higher performance requirements, where usually at least one current-loop is required as well. Multiloop current-voltage PID control strategy is able to represents a simple solution when designed using frequency-response techniques providing a number of advantages in terms of design and ease of implementation, ultimately achieving good regulation and a well-defined region of predictable stability for the converter operation. These multiloop PID schemes usually use either filter inductor [35]- [38] or filter capacitor [39]-[43] current as feedback variables, or a more complex structure, both filter inductor current and load current as feedback variables [36]-[40], [44]-[48]. The demerit of this control is that it is subject to steady state errors due to its finite loop gain at fundamental frequency, and also that it has a variable dynamic response depending on the loading conditions. To overcome these shortcomings, several control schemes have been proposed including adding proportional plus resonant (PR) or PID plus resonant (PID+R) compensator into the outer voltage regulation loop, [40], [48]-[51], [59], or using singlephase d-q frame controls with orthogonal stationary β-axis terms [49]-[56], [59], the inverter can theoretically achieve zero steady-state error and fast dynamic response respectively. The comparison of these multiloop controls is given in [40], [59]. But all of these lead to inconveniency in practical applications because of the following reasons: 1) owing to the variation of the fluctuating frequency, parameter of the resonant compensator is hard to choose; 2) since the PR or PID+R compensator is always nonideal, zero steadystate error can t be achieved in practice; 3) because of the high power rating and high voltage, the controller parameter design should be simple and reliable; 4) current sensors with high ratings and wide bandwidth must be used which, in most cases, makes these multiloop controls economically unattractive; 5) what s more, difficulty in modeling, complex design and sensitive to system parameters and load conditions. This paper comprehensively investigates divergent multiloop controls for single-phase inverters and presents a special RMS feedback control with the advantages of ease of implementation and excellent performance. The experimental verification of the control strategy is carried out in the 35 kv-6 mw wind turbine converter testing equipment. Fig. 1 Main circuit topology of the wind turbine lowfrequency disturbance testing system II. PROPOSED TOPOLOGY The modulation control techniques for multi level inverters can be classified according to switching frequency. Modulation techniques which have many commutations for the semi conductors in one period of the fundamental output voltage have high switching frequency. Very popular methods in industrial application are carrier based PWM with triangular carriers, they are: phase shifted carrier based and level shifted carrier based PWM schemes. Modulation control techniques that work with low switching frequency generally perform one or two commutation of the power semi conductors during one cycle of the output voltage. generating stair case wave form. For this low switching frequency, popular control technique is selective harmonic elimination pwm method. A. PSC-PWM CHB Multilevel Converter:

The phase-shifted carrier PWM (PSC- PWM) is a widely utilized modulation strategy for CHB multilevel converter due to its low THD, good linearity and wide bandwidth. Nonetheless, since the PSC-PWM has divergent types of variations, the performance differentiates from each other, such as different phase-shifted angle [60], various modulations for every single H-bridge (two-level modulation and three level modulation). Some of these are only straightforward variations of previous approaches, while others make differences in intrinsic principle. In psc pwm all the triangular carriers have the same frequency and same peak-peak amplitude.but there is a phase shift between any two adjacent carrier waves. For m Voltage levels (m-1) carrier signals are required and they are phase shifted with an angle of θ=(360 /m-1). The gate signals are generated with proper comparison of carrier wave and modulating signal. This paper applies a specific PSC-PWM, in which every single H-bridge uses double frequency modulation, or so-called three-level modulation. Therefore, the output voltage of the CHB multilevel inverter has 2n + 1 levels and the equivalent switching frequency is 2nk (n is the number of the cascaded H-bridges, k is H-bridge carrier frequency). Note that for analysis purpose, the CHB multilevel inverter can be incorporated within the control loop as a fixed gain factor which equals to n times of the modulation index, provided that the switching frequency is much higher than the required output frequency and the inverter is not operating in overmodulation region. promotion of multiloop PID controls as mentioned before. Fig. 2 shows the filter capacitor current feedback control adding PR or PID+R compensator into the voltage regulation loop. When economic efficiency is taken into consideration, this control is the best choice for Uninterruptible Power Supply (UPS) with satisfactory steady-state and transient performance [40], since it requires only one current measurement with a relatively low cost current sensor. However, this scheme cannot incorporate inverter over current protection since the inverter output current is not available to implement an over current fault. Figure 2. Filter capacitor current feedback control Figure 3. Filter inductor current feedback control (or adding load current feedback control) B.Multi loop V-I Control: Multiloop current-voltage control is the most prevalent control scheme due to its ease of implementation and excellent performance [59]. Fig. 2 and Fig. 3 are the aforementioned control schemes that are widely utilized. These controls are the Fig. 3 shows the filter inductor current feedback control adding PR or PID+R compensator into the voltage regulation loop. This allows overcurrent protection to be easily added to the control circuitry. The measurement of inductor current however requires the use of current sensors with a higher rating and wider bandwidth, since the inductor current contains most of the harmonics drawn by the load. Furthermore, the transient performance of the control system will be compromised due to comparatively small bandwidthand lower low-frequency loop gain. Furthermore, by adding load current feedback (not so called Feed forward [59]) into the feedback loop which is also depicted in Fig. 3, it achieves the performance advantage ofthe filter

capacitor current feedback scheme whilst also allowing inverter overcurrent protection to be implemented. Note that this kind of control is the most expensive one sinceit needs two high performance current sensors per phase measuring load and inductor current. Additionally, it can be observed how the LCF helps to further reduce the voltage error due to the low-frequency loop-gain improvement, especially under heavy loading condition. Moreover, thepid+r adding load and inductor feedback controller presents the highest bandwidth and loop gain which results in small steady state error and best dynamic response. Nevertheless, with the bandwidth and loop gain increased comparing with the conventional multiloop PI control; these controls suffer from instability with second order loads, such as LC filter loads [59]. and - Phase of the modulating sinusoidal signal respectively. Expanding (1) gives (2) It can be observed apparently that V distrub has three frequency components, they are fundamental component and two components that distribute symmetrically apart from the fundamental frequency by, which is the fluctuating frequency. C.Proposed Control Scheme From the proposed control scheme, the wind turbine works as a current source load pulling and feeding power into the testing equipment or the power grid, the RMS feedback control is a better choice for ease of control parameters design, precise output amplitude, and large stability margin (Fig. 4). Control diagrams are depicted in Fig. 6 and Fig. 7. Modeling andanalysis of this RMS feedback control is given in [61]. As mentioned before, the output voltage fluctuates with certain frequency and amplitude, therefore, the mathematical expression of this fluctuating signal is given by Figure 4. RMS feedback voltage control (adding sinusoidal signal in the instantaneous inner-loop) (1) Figure 5. RMS feedback voltage control (adding perturbation signal in the instantaneous inner-loop) According to the conventional RMS feedback control, theinstantaneous inner-loop reference signal is what needs to beproduced. When simply replacing the sinusoidal reference bythis fluctuating signal (Fig. 5), the accuracy of the fluctuating output will be deteriorated for the following reason: the outer loop reference is a constant value, while the feedback is the sliding window RMS of the fluctuating voltage which fluctuates as well, therefore the reference and the feedback can never match. Fig. 8 shows the proposed control scheme.unlike the conventional control, the reference of the outer loop is the sliding window RMS value of the perturbation signal. Note that the inner-loop uses a P controller for thesake of preventing single-side integral saturation which leads to transformer magnetic biasing [62]. Where, V distrub - fluctuating signal A- Amplitude - Angular frequency and φ- Phase of the modulated sinusoidal signal respectively. a m - Amplitude - Angular frequency

Figure 6. Control diagram of instantaneous innerloop Figure 7. Control diagram of RMS outer-loop Figure 9. Spectrum of the output voltage (10%-12Hz) Figure 8. Proposed control scheme III. SIMULATION RESULTS MATLAB-simulink simulations of the control strategy of cascaded H-Bridge multilevel converter system were performed. This paper presents an improved RMS feedback control which is suitable for this wind turbine converter testing system is simulated. The testing equipment topology is showed in Fig. 1, and the system parameters are as follows, LC Filter: L = 100 ¹H, C = 90 ¹F; carrier frequency: 2 khz, DC-link voltage: 1000 V. For the sake of safety in this high-power and high-voltage application, voltage waveform data is collected by Fluke-1760 and is analyzed by MATLAB (FFT analysis). In Fig. 9 and Fig. 10, the target fluctuating frequency is 10 Hz and fluctuating amplitude is 10% of the fundamental voltage. It is obvious that the experimental result under the proposed control is identical to the mathematical expression in (2), while the perturbation components under the conventional control exceed their theoretical value. Fig. 11 and Fig. 12 are the output voltages with a fluctuating frequency and amplitude of 10%, 12 Hz and 9%, 1 Hz. It can be observed that the voltage waveform is well regulated which is identical to the theoretical derivation results. Figure 10. Spectrum of the output voltage (9%-1Hz) Figure 11. Fluctuating output voltage (10%-12Hz) Figure 12. Fluctuating output voltage (9%-1Hz)

IV. CONCLUSION This paper presents an improved RMS feedback control which is suitable for this wind turbine converter testing system. The inner-loop P controller inherently leads to steady state error but free of phase lag, the RMS outer-loop guarantees the amplitude accuracy of the demand. Therefore, it successively achieves the control aim. All the theoretical findings are validated experimentally in the 35 kv-6 mw wind turbine converter testing equipment. REFERENCES [1]. F. Z. Peng and J. S. Lai, A multilevel voltagesource inverter withseparate DC sources for static var generation, IEEE Trans. Ind. Appl.,vol. 32, no. 5, pp. 1130 1138, Sep/Oct 1996. [2]. A. Nabae, I. Takahashi, and H. Akagi, A new neutral-point clampedpwm inverter, IEEE Trans. Ind. Appl., vol. IA-17, no. 5, pp. 518 523,Sep./Oct. 1981. [3]. T. A. Meynard and H. Foch, Multi-level choppers for high voltageapplications, Eur. Power Electron. Drives J., vol. 2, no. 1, p. 41, Mar.1992. [4]. Z. Du, L. M. Tolbert, B. Ozpineci, and J. N. Chiasson, Fundamentalswitching frequency strategies of a seven-level hybrid cascaded H- bridgemultilevel inverter, IEEE Trans. Power Electron., vol. 24, no. 1,pp. 25 33, Jan. 2009. [5]. D. Dong, T. Thacker, R. Burgos, F. Wang, and D. Boroyevich, On zero steady-state error voltage control of single-phase PWM inverters with different load types, IEEE Trans. Power Electron., vol. 26, no. 11, pp. 3285 3297, November 2011. [6]. N. M. Abdel-Rahim and J. E. Quaicoe, Analysis and design of a multiple feedback loop control strategy for single-phase voltage source UPS inverter, IEEE Trans. Power Electron., vol. 11, pp. 532 541, July 1996. [7]. N. Abdel-Rahim and J. E. Quaicoe, Indirect current control scheme for a single-phase voltage source utility interface inverter, in Proc. Can. Conf. Electr. Comput. Eng., 1993, pp. 305 308. [8]. H. Kim and S. K. Sul, Compensation voltage control in dynamic voltage restorers by use of feed forward and state feedback scheme, IEEE Trans. Power Electron., vol. 20, no. 5, pp. 1169 1176, Sep. 2005. [9]. A. Kawamura and T. Yokoyama, Comparison of five different approaches for real time digital feedback control of PWM inverters, in Proc. IEEE Ind. Appl. Soc. Conf., 1990, pp. 1005 1011. [10]. M. J. Ryan, W. E. Brumsickle, and R. D. Lorenz, Control topology options for single-phase UPS inverters, IEEE Trans. Ind. Applicat., vol. 33, pp. 493 501, Mar./Apr. 1997. M. Sathish, project title On Control Strategy of Cascaded H- Bridge Multilevel Converter with Fluctuating Output Voltage. Pursuing M.Tech (power electronics) in jyothishmathi institute of technology and sciences from 2012-2014. He has Completed his B.Tech in Electrical and Electronics engineering in Sindhura college of engineering and technology from 2008-2012. G. Sridhar obtained the B.Tech. degree in electrical engineering from University of Madras, INDIA in 2000 and M.Tech. degree in power systems with Emphasis on High Voltage Engineering in 2005. He is pursing Ph.D. degree in the area of multilevel inverters. He has 14-years teaching experience. At present he is working as Associate Professor in the Department of Electrical and Electronics Engineering, Jyothishmathi Institute of Science and Technology, Karimnagar. His research interests include Power Electronics and Multilevel inverters.