3000W ingle Output Power upply P-3000 series PECIFICAION MODEL OUPU INPU POECION FUNCION ENIONMEN OHE NOE DC OLAGE AED CUEN CUEN ANGE AED POWE OLAGE ADJ. ANGE LINE EGULAION LOAD EGULAION EUP, IE IME HOLD UP IME (yp.) OLAGE ANGE FEQUENCY ANGE EFFICIENCY (yp.) AC CUEN (yp.) INUH CUEN (yp.) LEAKAGE CUEN OELOAD OE OLAGE OE EMPEAUE ILIAY POWE() EMOE ON/OFF CONOL ALAM IGNAL OUPU OUPU OLAGE IM CUEN HAING WOKING EMP. WOKING HUMIDIY OAGE EMP., HUMIDIY P-3000-12 12 0A 0 ~ 0A 20W IPPLE & NOIE (max.) Note.2 150mp-p OLAGE OLEANCE Note.3 POWE FACO (yp.) 10.8 ~ 13.2 1.0% 0.5% 0.5% 0ms, ms at full load 10ms at full load 1 ~ 264AC 254 ~ 370DC 47 ~ 63Hz 0.95/230AC at full load 86% A/1AC A/230AC <2.0mA / 2AC 16A/230AC ~ 112% rated output power User adjustable continuous constant current limiting or constant current limiting with delay shutdown after 5 seconds, re-power on to recover 13.8 ~ 16.8 28.8 ~ 33.6 Protection type : hut down o/p voltage, re-power on to recover Protection type : hut down o/p voltage, recovers automatically after temperature goes down 12@0.1A(Only for emote ON/OFF control) Please see the Function Manual Please see the Function Manual 2.4 ~ 13.2 Please see the Function Manual 4.8 ~ 28 - ~ +70 (efer to output load derating curve) ~90% H non-condensing - ~ +85, 10 ~ 95% H P-3000-24 24 125A 0 ~ 125A 3000W 150mp-p 22 ~ 28 EMP. COEFFICIEN 0.05%/ (0 ~ 50 ) IBAION 10 ~ 500Hz, 2G 10min./1cycle, min. each along X, Y, Z axes AFEY ANDAD UL950-1, U EN950-1 approved WIHAND OLAGE I/P-O/P:3KAC I/P-:1.5KAC O/P-:0.5KAC AFEY & IOLAION EIANCE I/P-O/P, I/P-, O/P-:M Ohms / 500DC / 25 / 70% H EMC EMI CONDUCION & ADIAION Compliance to EN55022 (CIP22) (Note 4) HAMONIC CUEN Compliance to EN-3-2,-3 0mp-p 43 ~ 56 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 90% 90.5% P-3000-48 57.6 ~ 67.2 9.6 ~ 56 EM IMMUNIY Compliance to EN-4-2,3,4,5,6,8,11; EN504, EN55024, light industry level, criteria A MBF 104.5K hrs min. MIL-HDBK-217F (25 ) DIMENION 278*177.8*63.5mm (L*W*H) PACKING 4Kg; 4pcs/16Kg/1.89CUF 48 62.5A 0 ~ 62.5A 3000W 90 5 (12), 110 5 (24), 105 5 (48) (W1: detect on heatsink of power transistor) 90 5 (12), 85 5 (24), 75 5 (48) (W2 : detect on heatsink of o/p diode) File Name:P-3000PEC 10-10-18
+ 3000W ingle Output Power upply P-3000 series Mechanical pecification 278 236.3 27 Case No.982B Unit:mm 8-M4(Both ides) L=5mm 38 12.5 63.5 CN1 CN2 CN3 8 6 4 2 8 6 4 2 10 8 6 4 2 7 5 3 1 7 5 3 1 9 7 5 3 1 236.3 27 4-M4 L=5mm 7.9 OUPU LED 1 2 3 4 CN1 CN2 CN3 8 6 4 2 8 6 4 2 10 8 6 4 2 7 5 3 1 7 5 3 1 9 7 5 3 1 Air flow direction 162 177.8 INPU 13 10 16max. B1 Block Diagram I/P AC Input erminal Pin No. Assignment Pin No. 1 2 3 EMI FILE Assignment ACIE INUH CUEN LIMIING ECIFIE & PFC PFC CONOL O..P. POWE Control Pin No. Assignment(CN1,CN2) : H DF11-8DP-2D or equivalent Pin No. 1 2 3 4 POWE WICHING PWM CONOL LOAD HAING Assignment CG C P P O.L.P. FAN Pin No. 5,7 6 8 CG: emote ON/OFF Ground C : emote ON/OFF P :Output oltage External Control P : eference oltage erminal Control Pin No. Assignment(CN3) : H DF11-10DP-2D or equivalent Pin No. Assignment Pin No. Assignment Pin No. Assignment Pin No. Assignment 1 P OK GND 4 P OK2 7 G 10 OLD 2 P OK 5 CG 8 3 P OK GND2 6 C 9 OLP ECIFIE & FILE Assignment Mating Housing erminal (Current hare) H DF11-8D H DF11-**C or equivalent or equivalent O..P. DEECION CICUI EMOE CONOL ECIFIE & FILE : -emote ensing : Load hare : +emote ensing Mating Housing H DF11-10D or equivalent P OK GND: Power OK Ground CG: emote ON/OFF Ground : Auxiliary Output P OK: Power OK ignal (elay Contact) C: emote ON/OFF OLP: OLP/OLD:OLP mode select P OK2: Power OK ignal (L ignal) G: Auxiliary Ground erminal H DF11-**C or equivalent PFC fosc : 88KHz PWM fosc : KHz P OK C POWE (12/0.1A) File Name:P-3000PEC 10-10-18
3000W ingle Output Power upply P-3000 series Derating Curve tatic Characteristics a=25 90 LOAD (%) 50 LOAD (%) 70-0 10 30 50 70 AMBIEN EMPEAUE ( ) (HOIZONAL) 1 185 190 195 0 210 2 230 2 250 264 INPU OLAGE () Hz Function Manual 1.emote ON/OFF (1)emote ON/OFF control becomes available by applying voltage in CN1 & CN2 & CN3. (2)able 1.1 shows the specification of emote ON/OFF function. (3)Fig.1.2 shows the example to connect emote ON/OFF control function. able 1.1 pecification of emote ON/OFF Connection Method Fig. 1.2(A) Fig. 1.2(B) Fig. 1.2(C) Output on W Open W Open W Close W Logic Output off W Close W Close W Open Fig.1.2 Examples of connecting remote ON/OFF (A)Using external voltage source (B)Using internal 12 auxiliary output C 12 C 12 typ. CG W 12 typ. CG G W G (C)Using internal 12 auxiliary output C 12 typ. W CG G File Name:P-3000PEC 10-10-18
3000W ingle Output Power upply P-3000 series 2.Alarm ignal Output (1)Alarm signal is sent out through "P OK" & "P OK GND" and P OK2 & P OK GND2 pins. (2)An external voltage source is required for this function. (3)able 2.1 explain the alarm function built-in the power supply. Function Description Output of alarm(p OK, elay Contact) Output of alarm(p OK2, L ignal) he signal is "Low" when the power supply is above Low (0.5 max at 500mA) Low (0.5 max at 10mA) % of the rated output voltage-power OK POK he signal turns to be "High" when the power supply is under % of the rated output voltage-power Fail High or open (External applied voltage, 500mA max.) High or open (External applied voltage, 10mA max.) able 2.1 Explanation of alarm POK POK2 0.1uF POKGND External voltage and (he max. sink is 500mA and ) P OK GND2 External voltage and (he max. sink is 10mA and 30) Fig. 2.2 Internal circuit of P OK (elay, total is 10W) Fig. 2.3 Internal circuit of P OK2 (Open collector method) 3.Output oltage IM (1)Connecting an external DC source between P and on CN1 or CN2 that is shown in Fig. 3.1. (2)Adjustment of output voltage is possible between ~110%(yp.) of the rated output which is shown in Fig. 3.2. educing output current is required when the output voltage is trimmed up. 1 out OP >1% P 1~6 OUPU OLAGE (%) Non-Linear OUPU CUEN (%) Fig. 3.1 Add on 1~6 external voltage 1 2 3 4 5 6 EXENAL OLAGE (DC) 1 OUPU OLAGE (%) Fig. 3.2 Output voltage trimming File Name:P-3000PEC 10-10-18
3000W ingle Output Power upply P-3000 series 4.Current haring (1)Parallel operation is available by connecting the units shown as below (, and are connected mutually in parallel): (2)he voltage difference among each output should be minimized that less than 2% is required. (3)he total output current must not exceed the value determined by the following equation. (Output current at parallel operation)=(he rated current per unit) x (Number of unit) x 0.9 (4) In parallel operation 3 units is the maximum, please consult the manufacturer for other applications. (5) When remote sensing is used in parallel operation, the sensing wire must be connected only to the master unit. (6) Wires of remote sensing should be kept at least 10 cm from input wires. No.1(Master) CN1 No.2(lave) CN2 Load CN1 CN2 No.3(lave) CN1 CN2 (7) When in parallel operation, the minimum output load should be greater than 2% of total output load. (Min. Load >3% rated current per unit number of unit) (8) Under parallel operation, the "output voltage trim" function is not available. 5.elect O.L.P mode (1)emove the shorting connector on CN3 that is shown in Fig 5.1, the O.L.P. mode will be "continuous constant current limiting". (2)Insert the shorting connector on CN3 that is shown in Fig 5.2, the O.L.P. mode will be "constant current limiting with delay shutdown after 5 seconds, re-power on to recover. OLD OLP OLD OLP Fig. 5.1 emove the CN3 Fig. 5.2 Insert the CN3 OLP Mode : constant current limiting OLP Mode : constant current limiting with delay shutdown after 5 seconds File Name:P-3000PEC 10-10-18
3000W ingle Output Power upply P-3000 series 6.hree Phase Connect FIG. A: 3 3W 2AC YEM (ANDAD MODEL FO OCK) 2 2 L1 1 N1 L2 N2 2 L3 N3 3 N (NC) FIG. B: 3 4W 2/3AC YEM 2 N N L1 1 N1 L2 N2 2 L3 N3 3 3 FIG. C: 3 4W 190/110AC YEM 110 N (N.C.) L1 1 N1 L2 N2 2 L3 N3 3 N (NC) 190 File Name: P-3000PEC 10-10-18