Condumax CLS21 and CLS21D

Similar documents
Condumax CLS21 and CLS21D

Condumax CLS15 and CLS15D

Technical Information Condumax CLS21D/CLS21

Condumax CLS15 and CLS15D

Condumax W CLS15 and CLS15D

Technical Information Condumax CLS15D/CLS15

Condumax W CLS15 and CLS15D

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Condumax CLS16 and CLS16D

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Technical Information Memosens CLS82D

Indumax CLS50/CLS50D. Technical Information

Technical Information Indumax CLS50D/CLS50

Technical Information Orbipac CPF81D/CPF82D and CPF81/CPF82

Orbipac CPF81/CPF82 and CPF81D/CPF82D

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16

Conductivity Sensor for High-Temperature Applications ConduMax W CLS 13

Memosens CPS96D. Technical Information

Technical Information Orbipore CPS91D and CPS91

Ceramax CPS341D. Technical Information

Indumax CLS54D. Technical Information

Technical Information Memosens CPS96D

Technical Information Indumax CLS54

Memosens New technology for contactless, inductive, digital transmission of ph signals

Technical Information Smartec CLD18

Technical Information Smartec CLD18

Conductive conductivity measurement mypro CLM 431 / CLD 431 conductive

Liquisys M CLM223/253

Indumax H CLS54. Technical Information

Inductive conductivity measurement mypro CLM 431 / CLD 431 inductive

Technical Information Smartec CLD18

Technical Information Liquisys M CLM223/253

Turbimax CUS71D. Technical Information. Ultrasonic interface sensor Immersion sensor for interface measurement

Tophit CPS491 and CPS491D

Conductivity measurement SmarTec S CLD 132

Tophit CPS441 and CPS441D

Technical Information Memosens CCS50D

The transducer component converts the measured signal and displays the actual value.

Tophit CPS491 and CPS491D

Submersible pressure sensor For oils and fuels Model LF-1

Digital conductivity transmitter

Submersible pressure sensor For water and wastewater Model LW-1

Submersible pressure sensor For superior applications Model LF-1

Conductivity sensor for hygienic applications

OPTIFLUX 5000 Technical Datasheet

Flow Measurement SITRANS F M

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

OPTIFLUX 5000 Technical Datasheet

Temposonics. Magnetostrictive Linear Position Sensors. ET Analog Data Sheet

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

Smartec S CLD134. Technical Information

SMARTPAT COND 1200 Technical Datasheet

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

VITO LT. Global Experience. Locally Applied. A dependable choice.

ph / ORP Measurement mypro CPM 431

Coriolis Massflowmeter

0 2 1 â Ó. itemp HART TMT182. Technical Information

Liquisys M COM223/253

Endress Hauser. SmarTec M CLD 133 Conductivity Measurement

LST100 Ultrasonic level transmitter for upstream oil and gas

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions...

OPTIFLUX 1000 Technical Datasheet

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU

BlackLine Lf-GT / -EC electrolytic 2-electrode conductivity cells

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26

Level Measurement Continuous level measurement Radar transmitters

Coriolis Massflowmeter

Conductivity measurement Mycom S CLM 153

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Rosemount 3101, 3102, and 3105

ph/orp Measurement OPM223/253

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

OEM radar transmitter, for aggressive media level measurement

Liquisys M CPM223/253

Measuring and Controlling Unit Multronic OC

Turbidity sensor TurbiMax W CUS 41

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

High-quality pressure transmitter For general industrial applications Model S-10

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Conductivity Transmitter

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Signet ph/orp Electrodes

Technical Information Liquisys M CCM223/253

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Level Measurement Continuous level measurement Radar transmitters

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Temperature transmitter itemp PCP DIN rail TMT 121

Liquisys M CCM223/253

0 2 1 â Ó. itemp HART TMT182. Technical Information

Coriolis Mass Flow Meter Model TM

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

OPTISENS ORP 8590 Technical Datasheet

Float Switches with Permanent Magnet For Vertical Installation Model RSM

RADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below

Transcription:

Technical Information Condumax CLS21 and CLS21D Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1 cm -1 Application Measurements in media of medium and high conductivities: Medium separation in medium conductivities (milk/water) Medium separation in high conductivities (alkaline solution/ water) Drinking water treatment Wastewater treatment The cell constant of the sensor is k = 1 cm -1. The measuring range reaches from 10 μs/cm to 20 ms/cm. Sensors with a temperature sensor are used together with conductivity transmitters equipped with automatic temperature compensation: Liquiline CM442 / CM444 / CM448 (CLS21D only) Liquiline CM42 Liquiline CM14 (CLS21D only) Mycom CLM153 Liquisys CLM223/253 For measurement of resistivity, MΩ cm measuring ranges are available in the menus of these transmitters. Your benefits Various designs guarantee optimum adaptation to the process conditions and methods of installation Installation in pipes or flow chambers Compact design Available with plug-in head or fixed cable High chemical, thermal and mechanical stability IP 65 (with four-pole plug-in head) / IP 67 (with fixed cable) / IP 68 (with Memosens plug-in head) Quality certificate with statement of the individual cell constant Further benefits offered by Memosens technology Maximum process safety through contactless inductive signal transmission Data safety through digital data transmission Easy handling thanks to storage of sensor-specific data in the sensor Predictive maintenance possible thanks to registration of sensor load data in the sensor TI00085C/07/EN/13.12 71195954

Function and system design Measuring principle Conductive measurement of conductivity AC U I The conductivity of liquids is measured with the following measurement setup: Two electrodes are immersed in the medium. An AC voltage is applied to these electrodes which generates a current in the medium. The electric resistance or its reciprocal value, the conductance G, is calculated according to Ohm s law. The specific conductivity κ is determined using the cell constant k that is dependent on the sensor geometry. Conductive measurement of conductivity AC Power supply I Current meter U Voltage meter a0003416 General properties Communication and data processing with CLS21D Electrodes The sensor has two coaxial electrodes made of graphite for a large measuring range. The graphite guarantees high chemical stability and low polarization effects. Temperature compensation A temperature sensor is integrated to measure the medium temperature. Durability The sensor is pressure-proof up to 16 bar at 20 C (232 psi at 68 F). It can be applied with temperatures of up to 135 C at 2.5 bar (275 F at 36.3 psi). Digital sensors are able to store the following system data in the sensor: Manufacturing data Serial number Order code Date of manufacture Calibration data Calibration date Cell constant Change in cell constant Number of calibrations Serial number of the transmitter used for the last calibration Application data Temperature application range Conductivity application range Date of first commissioning Maximum temperature value Operating hours at high temperatures 2 Endress+Hauser

Dependability with CLS21D Reliability The Memosens technology digitalizes the measured values in the sensor and transfers them to the transmitter contactlessly and free from interference potential. The result: An automatic error message is generated if the sensor fails or the connection between sensor and transmitter is interrupted. The availability of the measuring point is dramatically increased by immediate error detection. Maintainability Sensors with Memosens technology have integrated electronics that allow for saving calibration data and further information such as total hours of operation and operating hours under extreme measuring conditions. When the sensor is connected, the calibration data are automatically transferred to the transmitter and used to calculate the current measured value. Storing the calibration data in the sensor allows for calibration and adjustment away from the measuring point. The result: Sensors can be calibrated unter optimum external conditions in the measuring lab. Wind and weather do neither affect the calibration quality nor the operator. The measuring point availability is dramatically increased by the quick and easy replacement of precalibrated sensors. Maintenance intervals can be defined based on all stored sensor load and calibration data and predictive maintenance is possible. The sensor history can be documented on external data carriers and evaluation programs at any time. Thus, the current application of the sensors can be made to depend on their previous history. Integrity The inductive and non-contacting measured value transmission of Memosens guarantees maximum process safety and offers the following benefits: All problems caused by moisture are eliminated. The plug-in connection is free from corrosion. Measured value distortion from moisture is not possible. The plug-in system can even be connected under water. The transmitter is galvanically decoupled from the medium. EMC safety is guaranteed by screening measures for the digital measured value transmission. Measuring system A complete measuring system comprises: a CLS21 or CLS21D conductivity sensor a transmitter, e.g. Liquiline CM42 a measuring cable, e.g. CYK71 or CYK10 Memosens data cable 1 3 2 Measuring system example 1 Liquiline CM42 transmitter 2 CYK10 Memosens data cable 3 Condumax CLS21D sensor a0003417 Endress+Hauser 3

GN/YE } Condumax CLS21 / CLS21D Input Measured variable Measuring range Conductivity Temperature Conductivity (referenced to water at 25 C (77 F)) CLS21D and CLS21 10 μs/cm to 20 ms/cm valid in the specified temperature range specified measuring accuracy up to 100 C (212 F) Temperature CLS21D CLS21-20 to 100 C (-4 to 212 F) -20 to 135 C (-4 to 275 F) specified measuring accuracy up to 100 C (212 F) Cell constant Temperature compensation k = 1.0 cm 1, nominal CLS21D NTC CLS21 Pt 100 (class A acc. to IEC 60751) Power supply Electrical connection CLS15 The sensor is connected to the transmitter using the measuring cable CYK71 or the fixed cable. Cable GY Coax BK Coax inner Sensor Plug ) shield (outer electrode) 2 conductivity (inner electrode) Outer shield (see wiring diagram of transmitter) Measuring cable, CYK71 or fixed cable GN WH YE BN n.c. } 3 1 Pt 100 a0005252-en CLS15D The sensor is connected to the transmitter via the measuring cable CYK10. Measuring cable CYK10 a0003350 4 Endress+Hauser

Performance characteristics, in general Measured error Each individual sensor is factory measured in a solution of approx. 5 ms/cm on a reference measuring system referred to NIST or DKD. The accurate cell constant is entered in the supplied quality certificate. The maximum measured error in cell constant determination is 1.0 %. Performance characteristics, CLS15D only Conductivity response time Temperature response time Maximum measured error Repeatability t 95 3 s t 90 296 s 5 % of the measured value 0.2 % of the measured value Installation Installation conditions The sensors are mounted directly via the process connection. Optionally, they can be installed in flow assemblies. Installation in the CLA751 flow assembly a0003418 Installation in the CLA752 flow assembly a0003422 Endress+Hauser 5

For installation of sensors with G1 thread in tanks, the CLA111 immersion and process assembly is available (see Accessories). Dipfit CLA111, mounting versions A, B and D a0003419 The measuring surfaces must be completely immersed in the medium during operation. Environment Ambient temperature Storage temperature -20 to +60 C (-4 to +140 F) 25 to +80 C (-10 to +180 F) Humidity 5 to 95% Protection degree CLS21 Fixed cable version IP 67 / NEMA 6 Plug-in head version IP 65 / NEMA 4X CLS21D IP 68 / NEMA Type 6P (10 m water column, 25 C, 168 h) 6 Endress+Hauser

Process Process temperature -20 to +135 C (-4 to 275 F) at 2.5 bar (36 psi) The maximum temperature for communication between Memosens sensors and the transmitter is 130 C (266 F). Process pressure 16 bar (230 psi) at 20 C (68 F) Pressure/temperature load curves p [psi] p [bar] 250 232 16 200 12 150 100 8 50 4 36.3 2.5 0 0 135-20 0 30 60 90 120 150 4 20 68 275 60 100 140 180 220 260 300 Mechanical pressure-temperature stability of T [ C] T [ F] a0003425 Mechanical construction Design, dimensions of CLS21 1 2 3 Fixed cable version with NPT 1" thread 1 Fixed cable 2 NPT 1" thread 3 Sensor shaft a0003426 Plug-in head version with Clamp 2" 1 Four-pole connector 2 Pg 9 cable gland 3 2" clamp 4 Sensor shaft a0003434 Endress+Hauser 7

NPT 1" AF 35 NPT 1" mm (inch) Ø24 (0.94) 16 (0.63) 61 (2.40) 14 (0.55) 113 (4.45) Dimensions of fixed cable version with NPT 1" thread 157 (6.18) a0003427 144 (5.67) 113 (4.45) 15 (0.59) 61 (2.40) 16 (0.63) Ø 34 (1.34) Ø64 (Ø 2.52) Ø24 (Ø 0.94) Dimensions of fixed cable version with Clamp 2" mm (inch) a0003428 144 (5.67) 61 (2.40) 54 (2.13) 10 (0.39) 5 (0.2) Ø 34 (1.34) Ø 47 (1.85) Ø55 (Ø 2.17) Ø24 (Ø 0.94) 16 (0.63) Dimensions of fixed cable version with SMS mm (inch) a0007560 8 Endress+Hauser

151 (5.94) 79 (3.11) 36 (1.42) 21 (0.83) 36 (1.42) 18 (0.71) Ø 44 (1.73) Ø24 (Ø 0.94) G1 151 (5.94) 61 (2.40) 54 (2.13) 36 (1.42) 15 (0.59) Ø 34 (1.34) Ø64 (Ø 2.52) Ø24 (Ø 0.94) 16 (0.63) mm (inch) Dimensions of plug-in head version with G1 thread a0003429 16 (0.63) Dimensions of plug-in head version with Clamp 2" mm (inch) a0003431 151 (5.94) 61 (2.40) 54 (2.13) 36 (1.42) 10 (0.39) Ø 34 (1.34) DN 25/DN 40 Ø24 (Ø 0.94) 151 (5.94) 61 (2.40) 54 (2.13) 36 (1.42) 10 (0.39) 5 (0.2) Ø 34 (1.34) Ø 47 (1.85) Ø55 (Ø 2.17) Ø24 (Ø 0.94) 16 (0.63) mm (inch) 16 (0.63) mm (inch) Dimensions of plug-in head version with dairy fitting a0003432 Dimensions of plug-in head version with SMS a0003450 Endress+Hauser 9

Dimensions of CLS21D Version with G1 thread a0007506 Version with 2" clamp a0007503 Version with dairy fitting a0007505 Version with NPT 1" thread a0018973 Weight Material Depending on version, approx. 0.3 kg (0.7 lb.) Electrodes: graphite Sensor shaft: polyether sulfone (PES-GF20) Thermal conductivity socket for temperature sensor: titanium 3.7035 10 Endress+Hauser

Process connections CLS21 Fixed cable version: Thread NPT 1" Clamp 2" acc. to ISO 2852 SMS DN 38 (1½") CLS21D Thread G1 Thread NPT 1" Clamp 2" acc. to ISO 2852 Dairy fitting DN 25 acc. to DIN 11851 Plug-in head version: Thread G 1 Clamp 2" acc. to ISO 2852 Dairy fitting DN 25 or DN 40 acc. to DIN 11851 SMS DN 38 (1½") Clamp connection: Sensors with clamp connections can be fixed using sheet metal brackets or solid brackets. Sheet metal brackets have a lower dimensional stability, uneven bearing surfaces causing point loads and sometimes sharp edges that can damage the clamp. We strongly recommend to always use solid brackets because of their higher dimensional stability. Solid brackets may be applied over the total pressure-temperature range (see temperature-pressure load curve). Certificates and approvals Ex approval Quality certificate CLS21 ATEX II 1G Ex ia IIC T3 / T4 / T6 FM/CSA IS/NI CL I Div. 1 & 2 GP A - D in combination with the Liquiline CM42 and Mycom CLM153 transmitters CLS21D-**G ATEX /NEPSI II 1G Ex ia IIC T3 / T4 / T6, IECEx Ex ia IIC T6 Ga CLS21D-**O FM/CSA IS/NI CL I Div. 1 & 2 GP A - D in combination with the Liquiline CM42 transmitter CLS21D-**V ATEX/NEPSI II 3G Ex nl IIC T3 / T4 / T6 for the use in Zone 2 with transmitter Liquiline CM42-KV*** ATEX and FM/CSA versions of digital sensors with Memosens technology are indicated by an orange-red ring in the plug-in head. With statement of the individual cell constant Ordering information Product pages www.products.endress.com/cls21 www.products.endress.com/cls21d Product configurator 1. You can choose from the following options on the product page located on the right: 2. Click "Configure this product". 3. The configurator opens in a separate window. You can now configure your device and receive the complete order code that applies for the device. 4. Afterwards, export the order code as a PDF or Excel file. To do so, click the appropriate button at the top of the page. Endress+Hauser 11

Product structure Condumax CLS21 The following product structure represents the status of printing. You can create a complete and valid order code on the Internet using the configurator tool. Measuring range and cell constant C Measuring range: 10.0 μs... 20 ms/cm (k = 1) Process connection and materials 1E 1N 2A 2B 2C 3B Thread G 1, PES (plug-in head version only) Thread NPT 1", PES (fixed-cable version only) Dairy fitting DN 25, DIN 11851, PES (plug-in head version only) Dairy fitting DN 40, DIN 11851, PES (plug-in head version only) Process connection SMS DN 38, PES Clamp 2", PES Measuring cable connection 2 with 5 m / 16.41 ft fixed cable 3 with 10 m / 32.81 ft fixed cable 4 four-pole DIN connector with Pg 9, DIN 43650-A Temperature sensor A Integrated Pt 100 temperature sensor D No temperature sensor CLS21- complete order code Product structure Condumax CLS21D Measuring range and cell constant C Measuring range: 10.0 μs to 20 ms/cm (k = 1) L PWIS-free for measuring range 10.0 μs/cm to 20 ms/cm (k = 1) Process connection and materials 1E Thread G 1, PES 1N Thread NPT 1", PES 2A Dairy fitting DN 25, DIN 11851, PES 3B Clamp 2", PES Approval G ATEX/NEPSI II 1G Ex ia IIC T3/T4/T6 Ga, IECEx Ex ia IIC T6 Ga O FM/CSA IS/NI Cl I Div. 1 & 2 GP A - D V ATEX/NEPSI II 3G Ex nl IIC T3/T4/T6 1 Non-hazardous areas CLS21D- complete order code 12 Endress+Hauser

Accessories In the following sections, you find the accessories available at the time of issue of this documentation. For information on accessories that are not listed here, please contact your local service or sales center. Connection Measuring cables CYK71 measuring cable Non-terminated cable for the connection of sensors (e.g. conductivity sensors) or the extension of sensor cables Sold by the meter, order numbers: non-ex version, black: 50085333 Ex version, blue: 50085673 CYK10 Memosens data cable For digital sensors with Memosens technology ph, redox, oxygen (amperometric), chlorine, conductivity (conductive) Ordering as per product structure (-> online Configurator, www.products.endress.com/cyk10) CYK11 Memosens data cable Extension cable for digital sensors with Memosens protocol Ordering as per product structure (--> Online configurator, www.products.endress.com/cyk11) Junction boxes Junction box VBM For cable extension 10 terminals Cable entries: 2 x Pg 13.5 or 2 x NPT ½" Material: aluminum Ingress protection: IP 65 (i NEMA 4X) Order numbers: cable entries Pg 13.5: 50003987 cable entries NPT ½": 51500177 Junction box VBM-Ex For cable extension in hazardous areas 10 terminals (blue) Cable entries: 2 x Pg 13.5 Material: aluminum Ingress protection: IP 65 (i NEMA 4X) Order no.: 50003991 Calibration solutions Precision solutions referred to SRM (Standard Reference Material) of NIST for qualified calibration of conductivity measuring systems according to ISO, with temperature table CLY11-A 74 μs/cm (reference temperature 25 C (77 F)), 500 ml (16.9 fl.oz) order no. 50081902 CLY11-B 149.6 μs/cm (reference temperature 25 C (77 F)), 500 ml (16.9 fl.oz) order no. 50081903 CLY11-C 1.406 ms/cm (reference temperature 25 C (77 F)), 500 ml (16.9 fl.oz) order no. 50081904 CLY11-D 12.64 ms/cm (reference temperature 25 C (77 F)), 500 ml (16.9 fl.oz) order no. 50081905 For further information on calibration solutions see Technical Information TI00162C/07/EN. Endress+Hauser 13

Assemblies Dipfit CLA111 Immersion assembly for open and closed tanks with flange DN 100 Ordering acc. to product structure, --> online configurator: www.products.endress.com/cla111 Technical Information TI00135C/07/EN CLA751 flow assembly For installation of conductivity sensors with G 1 thread. Inlet (bottom) and outlet (lateral) DN 20 with union nuts G 1. Stainless steel 1.4571 (AISI 316Ti) Max. temperature: 160 C (320 F) Max. pressure: 12 bar (174 psi) Order no.: 50004201 Ø50 (1.97) G1 160 (6.30) Ø 20 (0.79) 120 (4.72) G1 CLA751 flow assembly G1 mm (inch) a0003436 CLA752 flow assembly For installation of conductivity sensors with G 1 thread Inlet (lateral) and outlet (lateral) DN 20 with G ½ internal thread Polypropylene (PP) Max. temperature: 90 C (194 F) Max. pressure: 6 bar (87 psi) Order no.: 50033772 G1 160 (6.30) G½ G½ mm / inch Ø 80 (3.15) CLA752 flow assembly a0003437 14 Endress+Hauser

Endress+Hauser 15

TI00085C/07/EN/13.12 71195954 FM9