Application for electricity connections Housing development for up to four dwellings

Similar documents
Click to edit Master title style. Click to edit Master title style. Northern Powergrid Asset Recording Guidance

Company Directive STANDARD TECHNIQUE: SD5F. Relating to connecting multiple small low voltage connections with limited network analysis

Planning Department APPLICANT S CHECKLIST

your home What do you need to do? What s the cost*? nienetworks.co.uk Connecting your home Complete an application

APPENDIX A See rule 3(1) þþ APPLICATION UNDER SECTION 217-C OF THE TAMIL NADU DISTRICT MUNICIPALITIES ACT 1920 TAMIL NADU ACT V OF 1920.

Last Name: First Name: M.I:

June 2014 For any information or queries relating to fundraising for headspace, please contact:

June 2014 For any information or queries relating to fundraising for headspace, please contact:

ELECTRIC NETWORK DESIGN APPROVAL APPLICATION

A Householder s Planning Guide for the Installation of Antennas, including Satellite Dishes

Lodgement checklist: water heater (solar or heat pump)

THIRD SCHEDULE Form of Application For A Revised Disability Access Certificate Article 20E(2)

Example Plans: Business Signs (Not For Construction)

PROCEDURE FOR INSPECTION OF ELECTRICAL INSTALLATIONS ABOVE 250KVA

Company Directive STANDARD TECHNIQUE: SD5R/2. Earth Fault Loop Impedances and Phase to Neutral Loop Impedances at LV Installations

City of Lompoc Building & Safety Services Section 100 Civic Center Plaza Lompoc, CA Phone: Fax:

For Office Use: Filing Date: Case Number: Zoning District: LIST ALL ADDRESSES INVOLVED IN YOUR PROJECT:

INCOMPLETE APPLICATION WILL NOT BE ACCEPTED COMPLETE ALL INFORMATION BELOW. Construction Value: $

SITE PLAN REVIEW GUIDELINES Rev. 2016

Residential Plot Plans

APPLICATION FOR THE APPROVAL OF BUILDING PLANS (Complete in black ink)

Guidance for UK Fire and Rescue Services. Dealing with incidents on or near National Grid high voltage overhead lines

The standards you can expect. The level of service that we provide and what you're entitled to if we don't.

DETERMINATION OF POPULATION REGULATION

REPORT OF DIRECTOR OF CITY OPERATIONS AGENDA ITEM: 7 PORTFOLIO: TRANSPORT, PLANNING & SUSTAINABILITY (COUNCILLOR RAMESH PATEL)

HAMILTON TOWNSHIP Department of Planning and Zoning Application for a Commercial / Industrial Site Plan Review

Residential Construction Checklist Single and Two Family Construction

Harwell Cemetery Regulations

Application Form for a GNSS Repeater Licence

EDS LV SUPPLIES TO MOBILE PHONE BASE STATIONS MOUNTED ON TRANSMISSION TOWERS

Clear Creek County Site Development

TS RES - OUTSTANDING ISSUES

EDS LV ELECTRICAL SERVICE DRAWINGS

Minor Site Plan Review Process

Permit Application. General Information

Service Altera on Guide to applying online for a Quota on

Mailing Address: Fax number: City: State: Zip: Property Owner: City: State: Zip: City: State: Zip:

Town of Skowhegan Application For Development Review

G81 PART 1 FRAMEWORK APPENDIX

APPLICATION FOR SITE PLAN REVIEW

REQUIRED MATERIALS FOR RESIDENTIAL ACCESSORY STRUCTURE PERMITS (Garages, Sheds, and other structures over 200 sq ft or on a permanent foundation)

Procedure to Petition for Plat Review and Site Plan Review

Estimated Cost of Project Contractor License No. Contractor Qualifier No.

Non-Police Personnel Vetting - (NPPV) Basic

SPECIFICATIONS FOR NEW UNDERGROUND RESIDENTIAL DISTRIBUTION SYSTEMS

BERKELEY COUNTY ENGINEERING AND

RANDY SCHMELING INSPECTIONS HARDER ROAD THREE RIVERS, MI Home Mobile

National Grid s commitments when undertaking works in the UK. Our stakeholder, community and amenity policy

WESTERN POWER DISTRIBUTION

Mussey Township Building Department. 135 N. Main, P.O. Box 118 Capac, MI Phone: Fax:

DOWNTOWN DEVELOPMENT REVIEW BOARD APPLICATION

NEW SINGLE FAMILY HOMES

TOWN OF NORTH BRANFORD

Business radio light licence application form OfW432

Remotes Case 2&3 Form REINDEER Cases 2&3 -Connection Impact Assessment (CIA) Application

Tenant Sign Criteria. Guidelines. Requirements. Braelinn Village, Peachtree City

YOU ARE ADVISED TO SUBMIT THIS CHECKLIST IN CONJUNCTION WITH YOUR PLANNING APPLICATION

Request for Modification Review Information DO NOT COMMENCE ANY WORK PRIOR TO WRITTEN APPROVAL BY THE BOARD IF DIRECTORS

LAND AT LONG BUCKBY IMMEDIATE RESIDENTIAL LAND 0.42 ha

CITY OF EL MIRAGE DEVELOPMENT APPLICATION PROCESS

City of Thousand Oaks

Temporary Sign Permit

A guidance note on the national standards for the validation and determination of planning applications and other related consents in Scotland

ACCESS TO HIGH VOLTAGE APPARATUS

INFORMATION FOR OBTAINING A BUILDING PERMIT

CITY OF EL MIRAGE DEVELOPMENT APPLICATION PROCESS

SUBDIVISION PLAT APPLICATION

RESIDENTIAL DEMOLITION PERMIT APPLICANT CHECKLIST

White Lake Township Building Dept Highland Rd. (248) White Lake, MI Fax (248)

Conceptual, Preliminary and Final Site Plan Review in Holladay City

SUBMIT YOUR PIC APPLICATION:

Planning and Zoning Application & Checklist

OVER-HEIGHT FENCE/RETAINING WALL CERTIFICATION APPLICATION

Request for Proposals: Beacon Hill Pump House Mural Project

C I T Y O F M c K I N N E Y PLANNING

CITY OF LOVELAND HOMEOWNERS GUIDE FOR BUILDING PERMITS FOR HOME IMPROVEMENTS

SECTION SUBMITTAL PROCEDURES

Company Directive STANDARD TECHNIQUE: SD1E/2. Technical Requirements for Customer Export Limiting Schemes

Site Plans. City of Hopkins Inspections Division st Street South, Hopkins, MN Fax

Community & Economic Development Department Planning Division Frederick Street PO Box 8805 Moreno Valley, CA SUBMITAL REQUIREMENTS

Architectural Review Application

List of Figures. List of Forms

SMALL PROJECTS & IMPROVEMENTS: DOG RUNS, PATIO ENCLOSURES & FENCES, EXTERIOR IMPROVEMENTS (Abbreviated Design Review Application)

Section 1.0: Introduction. Section 3.0: Planning. Section 4.0: Power Quality. Manual 0295 Supply & Planning Manual Updated: 01/08/2017

SITE PLAN, SUBDIVISION & EXTERIOR DESIGN REVIEW PROCESS

Developer Services. Developers Guide to the Adoption and Vesting of a Development Site. November 2017

Procedure for Obtaining Design Review Committee Approval

NSP/007/019 - Guidance on Substation Design: EHV Substation Drawing Policy

Telecommunication Application Form

RELEVANT ELECTRICAL STANDARDS

OAK RUN BUILDING PERMIT

Hartwell Lake Application for Dry Dredging

SIGN PERMIT APPLICATION

City of Hamilton INFORMATION FOR CONDITIONAL USE PERMIT

CITY OF SCHENECTADY NEW YORK CITY PLANNING COMMISSION

2014 NEC Changes Part 1

Residential Room Addition / Remodel Submittal Requirement Checklist

CHECKLIST THE FOLLOWING INFORMATION AND DOCUMENTATION MUST BE SUBMITTED TO DEVELOPMENT SERVICES BEFORE YOUR APPLICATION CAN BE PROCESSED.

EE Limited - Public Wireless Network Licence Company Registration no First Issued: 26/03/93 - Licence Number: Rev: 20-10/01/17

SVRA ARCHITECTURAL PERMIT

Transcription:

Electricity Thank you for considering Western Power Distribution for your electricity connections. We have put together these notes to help you fill out your and to ensure we receive all the correct information for your application to be processed easily. Section A Your details Please complete this section with your contact details as well as the site where the electricity connection is to take place. Please advise us of the builder/developer s details if you are applying on their behalf. Section B Number and type of connections required Please complete this section stating your connection requirements and if the application is for a Budget Estimate or firm Connection Offer. A Budget Estimate will be non-binding and for indicative costs only. A Connection Offer will set out detailed terms and conditions and once accepted will be binding on both parties. Section C Load requirements If you are connecting any motors or welders, please let us know about them. Please tell us the following: Motors Type, 1 or 3 phase, Rating kw/hp, DOL/Star Delta, Starting current, Starts per hour. Welders Input voltage, Rating, Phases, Welds per minute. The manufacturer or equipment installer should be able to help you with this. Off-peak means the heating that can only operate during a pre-arranged time (usually 7 hours) in the range of hours 23:00 07:00 and is usually controlled by the Meter Operator s time-switch. Section D - Generation Please tell us if there will be any on-site generation. Please note that if you require a Connection Offer we will require further technical information. Information and forms to download are available on our website at http://www.westernpower.co.uk/generationconnections.asp Section E Protective multiple earthing (PME) To find out if we can provide you with a PME, please advise us if the site consists of metal framed buildings. Section F Site conditions It is a requirement of the Compliance with the Construction (Design & Management) Regulations 2007 that a proper assessment is made of the risks on site. Please complete this section to help us process your application efficiently, in a way appropriate to the environmental and practical considerations on and around the site. Section G Additional information Please provide any additional information that may be relevant to your application. Section H Signature Please ensure you sign and date this form on page 4, and enclose one copy of the Location and Site Layout Plan. Guidance is given on pages 5-6. Important To prevent your application from being delayed, please ensure you have enclosed all the required information. Did you know? You can get a competitive quote from an Independent Connections Provider (ICP) for your electricity connection. We can provide you with a complete connection service but you may also ask an ICP or Independent Distribution Network Operator (IDNO) to undertake some of the works (known as the contestable works ). Find out more www.westernpower.co.uk/connections/competition-in-connections 1/6

Section A - Your details Address for correspondence Title, initials and surname Company name Building name/number Street Town Site address (where connection(s) required) Customer name Site name/plot numbers Street Town City City Postcode Postcode Contact details Please provide details of whom we should contact in the event of any queries Name Fax Telephone Mobile Email Section B Number and type of connections required Total number of dwellings requiring connection/increased supply. Connection requirements. New Increased load Decreased load Do you require a temporary supply? Yes No If temporary, duration required (months). If temporary, maximum power required in kva. Do you require an indicative Budget Estimate or a firm Connection Offer? Budget Estimate Connection Offer We will normally provide a Connection Offer that sets out the charge for WPD undertaking all of the connection works. If you prefer we can provide a Connection Offer for WPD undertaking only the non-contestable connection works, so that an ICP or IDNO can be appointed to undertake the design and construction of the contestable works. Do you require WPD to provide a Connection Offer for undertaking all work or an offer for non-contestable works only (POC)? All Works POC only 2/6

Section C Load requirements The normal maximum capacity for individual domestic properties is 15kW. If you require a greater capacity, please enter the capacity here: Date connection required: (We will do our best to meet your connection requirements but cannot guarantee to make this date. If you accept our Connection Offer we will agree a date to make the connection.) Disturbing loads If you are connecting any electrical equipment which may cause a disturbance on the electricity system (e.g. motors, welders), please provide us with details. The notes at the front of this form will advise you on what we need to know. Details of electrical loading Please choose your space heating type: Gas Electric (Storage and Direct) For electric storage heating total off peak load per property is For electric direct heating total load per property is kw kw kw D M Y Electric boiler Other Ground source heat pumps If other, please specify Note: For electric boilers and heat pumps, please provide the manufacturer s specification sheet. Please choose your water heating type: Gas Electric (Storage and Direct) Electric boiler Other Ground source heat pumps If other, please specify Please provide any further information in Section G Additional Information on page 4. Section D Generation Will there be any on-site electricity generation? Yes No Will generators be capable of operating in parallel with WPD s system? Yes No Please visit our website www.westernpower.co.uk for information on connecting electricity generation. Section E Protective multiple earthing (PME) PME is normally provided for each supply. However, some methods of building, in particular multioccupancy steel framed buildings, do not allow this means of earthing. In such cases alternative earthing solutions can be provided by your electrical contractor. Is your building steel framed and subdivided into units? Yes No Section F Site conditions 3/6 Are there any site conditions that you need to make us aware of (for example potential hazards such as asbestos, air pollution, ground contamination). If so, please include in the Additional information section. We may ask you for more information.

Section G Additional information Boundary Plan request Please provide a plan clearly showing the ownership and boundaries of your site. Where appropriate, we will design a cable route that is within the boundary of your land, avoiding the need for third party agreement. This can reduce legal costs and lead times required to complete the work. This information may be available from: The Land Registry your planning application your property deeds hand drawings on an existing plan. Note: This is the preferred option, but if a Boundary plan is not available, we ll accept the boundary being marked on the Location Plan instead. Please make sure the detail is accurate, so we can avoid delays later. Section H Signature Signature of applicant Date Print name Position in company Under section 16(1) of the 1989 Electricity Act, we are obliged to provide a Connection Offer to any person entitled to apply for a new, increased or reduced connection to our Distribution System. Applications for a connection to our Distribution System can either be made by the owner or occupier of the premises, or by an approved contractor, supplier or agent, acting with the consent of the owner or occupier. Our response time to any person seeking a new, increased or reduced capacity connection will be in accordance with our Licence, and the Electricity (Connection Standards of Performance) Regulations 2010 or, where we are providing only non-contestable services, Licence Condition 15. It will be no later than 3 months after the application date, except in cases where a longer period has been agreed with the applicant. Our Connection Charges Statement provides information on the typical costs involved in providing a connection and information on the standards of service to the provision of a connection. Further details about the Statement of Charges can be obtained at www.westernpower.co.uk/new-connections/connections.aspx 4/6

Procedure for the submission of site plans for a new connection enquiry Introduction In order to provide a connection offer, we require one copy of the Location Plan and one copy of the Site Layout Plan, together with your. The Location Plan shows where to find the proposed site for the new connection. The Site Layout Plan provides further details on how the site is laid out and includes dimensions of the new connection. Location Plan 1 All applications should have one Location Plan enclosed. You must highlight the site location on the plan. 2 Location Plans can be obtained by using A-Z street maps or via the internet, which is now available at most public libraries. The following internet sites offer instant Location Plans: multimap.com ordsvy.gov.uk Diagram 1 - Example of a Location Plan 5/6

Procedure for the submission of the site plans for a new connection enquiry Site Layout Plan 1 In the absence of an architect s drawing, all applications need to have two Site Layout Plans enclosed. You must draw all proposed buildings and accesses onto the site plan showing accurate measurements. 2 The full site address and proposed meter position should be marked onto the plan with an X (see across for guidelines on meter positions). 3 The size of the new building should be shown on the plan as well as its position onsite in relation to existing features of the site plan using measurements. 4 Measurements should be taken and drawn on the plan to show the position and size of the new building to the nearest 0.1m. 5 Measurements should be taken from permanent features on-site eg existing buildings, boundaries, footpaths and kerb lines. Measurements should be legible and easy to read. 6 Any existing buildings to be demolished should also be marked on the plan. 7 Please include the site boundary. 8 Please mark any access roads and temporary accesses to the site. Please do not take measurements from doorways, gate posts, bay windows, temporary posts and garden gateways or street furniture eg lamps, signs and bollards. 3 Show the size and position of the new building 4 Measurements taken should be to the nearest 0.1m NEW HOUSE X Meter position New and re-serviced domestic housing services and commercial supplies (up to 100 Amps) should be installed in outdoor meter boxes. These should be mounted onto an external wall on the front or side elevation of the property in front of any fence or gates to allow unrestricted public access. They should be fitted at a minimum height of 400mm and a maximum height of 1,000mm from ground level to the bottom of the box. Properties converted into flats must have either external meter boxes where practcable or internal at a common area adjacent to the front door. The following meter positions are not permitted: at the rear of the property at the side of the property behind fences or gates facing or opening directly onto public footpaths or into alleyways or entries within a coal dustbin, refuse store, garage or porch under windows, unless minimum installation height can be achieved. Note: any proposal of indoor meter positions will only be accepted where the developer can demonstrate that the Local Planning Authority will not permit an outdoor meter box by virtue of the building being listed, in a conservation area, or for a commercial supply where a meter box is not feasible eg shop frontage. 1 Proposed buildings and their access must be shown on site layout (East ) plc Registered in England and Wales No. 2366923 (West ) plc Registered in England and Wales No. 3600574 () plc Registered in England and Wales No. 2366985 () plc Registered in England and Wales No. 2366894 Registered Office: Avonbank, Feeder Road, Bristol BS2 0TB 7 Mark the site boundary 5 Measurements to be taken from permanent features on site 2 Show the site address and meter position 8 Show the access roads and temporary accesses PROPOSED NEW PROPERTY 26 CHURCH STREET ANYTOWN TO BE DEMOLISHED 6 Show any existing buildings that are to be demolished X - METER POSITION Diagram 2 - Example of a Site Layout Plan 6/6 Note: Site Layout Plans can be obtained from Local Council offices, high street map shops and Ordnance Survey stockists. There is a charge for this service. Site plans are at a scale of 1:1250 or 1:500 and show the existing geographical area.