Passive Component LCR Meter

Similar documents
Passive Component LCR Meter

Passive Component LCR Meter

R/C SMD Tweezers Multimeter Model RC200

400Amp True RMS AC/DC Clamp Meter Model EX613

Model True RMS AC/DC 30A Mini Clamp-on Meter. User Guide

400Amp True RMS AC Clamp Meter + NCV

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

User Guide. AC/DC Mini Clamp Meter. Model

LCR METER Model:

Compact MultiMeters + Voltage Detector

AMM-3035 User s Manual

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

Micro-Ohmmeter Model UM200

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

Benchtop LCR Meter. Model Tenma Test Equipment 405 S. Pioneer Blvd. Springboro, OH

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

EasyView Light Meter with Memory

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

Autoranging Multimeter Extech EX503

LCR METER OPERATION MANUAL. Model : LCR Hz 120 Hz 1 KHz 10 KHz 100 KHz, Precision

200Amp AC Clamp Meter + NCV Model MA250

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

LCR METER Model:

User s Guide. Digital AC/DC Clamp Meter Model 38394

USER'S MANUAL DMR-6700

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

AMМ-3320 Multi-function LCR USER`S MANUAL

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

User Guide. Digital AC/DC Clamp Meter Model 38394

OPERATING INSTRUCTION

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

User s Guide. Model MA A AC Mini Clamp-on Meter

MODEL: D03128 CLAMP METER

DDM350 Pen-Type Digital Multimeter User s Manual

USER GUIDE. IR Thermal Scanner. Model IRT500

User's Guide. Pinless Moisture/Humidity Meter with IR Thermometer + Bluetooth. Model MO297

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

USER GUIDE. Mini InfraRed Thermometer with Laser Pointer MODEL 42500

USER MANUAL. LUX/FC Light Meter. Model LT505. Additional User Manual Translations available at

Agilent U1731C, U1732C, and U1733C Handheld LCR Meter

User's Manual. Clamp-on Power Datalogger. Model

True RMS AC / DC Power Clamp Meter Model

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

Advanced Test Equipment Rentals ATEC (2832)

DM-45 Digital Multimeter

Heavy Duty CFM-CMM Thermo-Anemometer With built-in non-contact IR Thermometer and Laser Pointer Model HD300

BENCH METER Model>9803. Wavecom Instruments

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

Page 1 of IR Port 5 External power port 6 Calibration button port 7 DUT + jack 8 DUT - jack 9 Shielding grounding jack

Elma 6400 LCR Meter. English 31 EAN: riešenia na presné meranie

U1730C Series Handheld LCR Meters

User s Guide. 400A AC/DC Clamp Meter. Model MA220

AUTORANGING TRUE RMS MULTIMETER USER GUIDE. INST151 Doc 1.00

USER'S MANUAL DMR-4300

User Guide. EasyView Digital Light Meter. Model EA31

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

Sales: Technical: Fax:

USER'S MANUAL DMR-4350

APPA 300 Series. The Most User-Friendly High Performance Multimeter

USER GUIDE. Extech EX850 True RMS 1000 Amp Clamp Meter. Bluetooth TM and Android TM ready. Patented

Pocket Size Digital Multimeter with USB Model: A & A

OPERATION MANUAL. Multi-Function LCR LIST OF PRODUCTS MODEL KM 520B

USER MANUAL. Extech EX850 True RMS 1000 Amp Clamp Meter. Bluetooth TM and Android TM ready. Patented

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

Agilent U1700 Series Handheld LCR Meters

Not for Reproduction

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

DVM1190 DIGITAL MULTIMETER

Frequency up to 100 khz

Dawson DDM190. Digital Multimeter User s Manual

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

114, 115, and 117. True-rms Multimeters. Users Manual

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

5XP-A 15XP-A 35XP-A Compact Digital Multimeters

Bench LCR Meter Model 891

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Digital automotive analyser 13 function with ic

MW3105 DIGITAL CLAMP MULTIMETER

Analog Technologies. Multimeter 115C and 117C

User s Guide. Model Dual Input Type J/K Digital Thermometer INTRODUCTION

USER'S MANUAL AM-100 AM-105 TRMS AM-110 TRMS. Digital Multimeters

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

Models 885 & 886 LCR METER OPERATING MANUAL

AC/DC CLAMP METER USER S MANUAL

Transcription:

User's Guide Passive Component LCR Meter Model 380193 LCR Meter 380193 APO AUTO c PAL D 1kHz µ F -0 ENTER FREQ PAL SER 1 2 3 RANGE L/C/R Q/D/R 4 5 6 >2sec HOLD MIN MAX SET 7 8 9 REL Hi / Lo LIMITS TOL DO NOT APPLY VOLTAGE TO TERMINALS DISCHARGE CAPACITOR BEFORE TESTING + AUTO-POWER OFF

INTRODUCTION Congratulations on your purchase of Extech's Model 380193 LCR meter. This meter will accurately measure capacitors, inductors and resistors using the test frequencies of 120Hz and 1 khz. The dual display will simultaneously display the associated quality factor, dissipation or resistance value using a series or parallel equivalent circuit. The included RS-232c PC interface feature with Data Acquisition permits the user to capture readings to a PC for data storage, viewing, printing, and exporting to spreadsheet for graphing and other data manipulation tasks. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. International Safety Symbols! Caution! Refer to the explanation in this Manual Caution! Risk of electric shock Earth (Ground) Safety Precautions 1. Make sure any covers or battery doors are properly closed and secured. 2. Always remove the test leads before replacing the battery or fuses. 3. Inspect the condition of the test leads and the meter itself for any damage before operating the meter. Repair or replace any damage before use. 4. To reduce the risk of fire or electric shock, do not expose this product to rain or moisture. 5. Do not exceed the maximum rated input limits. 6. Always discharge capacitors and remove power from the device under test before performing Inductance, Capacitance, or Resistance. 7. Remove the battery from the meter if the meter is to be stored for long periods. 2

>2sec 1kHz METER DESCRIPTION 1. Q/D/R display 6 2. L/C/R display 3. Keypad 4. Test fixture 7 2 APO AUTO c LCR Meter 380193 PAL D µ F 1 5. Input jacks 6. External power input 7. Protective holster 3-0 ENTER PAL FREQ SER 1 2 3 RANGE L/C/R Q/D/R 4 5 6 HOLD MIN MAX SET 8. Battery compartment (rear) 4 7 8 9 REL Hi / Lo TOL LIMITS + AUTO-POWER OFF 8 5 Display Symbols and Annunciators APO Auto Power Off 1KHz 1kHz test frequency R Recording mode active 120Hz 120Hz test frequency MAX Maximum reading M Mega (10 6 ) MIN Minimum reading K kilo (10 3 ) AVG Average reading p pico (10-12 ) AUTO AutoRanging active n nano (10-9 ) H Data hold active micro (10-6 ) SET SET mode m milli (10-3 ) TOL Tolerance mode H Henry (inductance units) PAL Parallel equivalent circuit F Farad (capacitance units SER Series equivalent circuit Ohms (resistance units) D Dissipation factor Upper limit Q Quality factor Lower limit R Resistance Relative mode L Inductance Low battery C Capacitance % Tolerance (percentage) 3

OPERATING INSTRUCTIONS CAUTION: Measuring a DUT (device under test) in a live circuit will produce false readings and may damage the meter. Always remove power and isolate the component from the circuit to obtain an accurate reading. CAUTION: Do not apply voltage to the input terminals. Discharge capacitors before testing Note: Measurement considerations for resistance <0.5 ohms. 1. Use positive contact alligator clips. 2. Perform a SHORT calibration zero to remove stray impedances. 3. Clean the DUT leads / contacts of oxidation or film to minimize contact resistance. Power 1. Press the power key to turn the meter on or off 2. Auto-Power OFF (APO) If the keypad is inactive for 10 minutes, the meter will automatically shut down. If this occurs, press the key to resume operation. 3. Auto-Power Off disable. To disable the auto-power off feature, from the off position, press and hold the power on key until APO OFF appears in the display. Auto-Power Off will also be disabled if the MIN MAX record mode is used or if the meter is powered by an external power supply. Frequency Selection Press the FREQ key to select either 120Hz or 1kHz as the test frequency. The frequency selected appears in the display. Generally, 120Hz will be used for large electrolytic capacitors and 1kHz used for most other tests. Parallel/Series Selection Press the PAL SER key to select either a parallel (PAL) or series (SER) equivalent circuit. The selected mode will appears as SER or PAL in the display. This mode defines the R loss of an inductor or capacitor as a series loss or a parallel loss. Generally, high impedances are measured in the parallel mode and low impedances are measured in the series mode. Range Selection The meter turns on in the autoranging mode with AUTO indicated in the display. Press the RANGE key and the AUTO indicator will disappear. Each press of the RANGE key will now step through and hold the available ranges for the parameter selected. To exit the manual range mode, press and hold the RANGE key for 2 seconds. 4

Inductance, Capacitance, Resistance Selection The L/C/R key selects the primary parameter measurement function. Each press of the key will select either inductance (L), capacitance (C) or resistance (R) along with the proper units of H (henries), F (farads) or (ohms) in the main large display. Quality, Dissipation, Resistance Selection The Q/D/R key selects the secondary parameter measurement function. Each press of the key will select either the quality (Q) or dissipation (D) indicators or resistance ( ) units in the small secondary display. Hold and Backlight Selection The HOLD >2sec key selects the Hold feature and also enables the display backlight. Press the key and the H indicator will appear in the display and the last reading will freeze in the display. Press the key again and the reading will begin to update again. Press and Hold the key for 2 seconds and the display backlight will turn-on. To extinguish the backlight, press and hold the key again for 2 seconds or wait 1 minute for it to automatically disable. Minimum, Maximum and Average Selection The MAX MIN key selects the recording function. Press the key and the R indicator will appear in the display and the meter will begin recording the minimum, maximum and average measured values. When this mode is entered, the auto power off and the function keys are disabled. Max-Min operation 1. Set all the function parameters for the test. 2. Press the MAX MIN key. The R indicator will appear and a beep will sound after approximately six seconds. Two beeps will sound every time the max or min is updated. 3. Press the MAX MIN key. The MAX indicator and the maximum recorded value will appear in the display 4. Press the MAX MIN key. The MIN indicator and the minimum recorded value will appear in the display 5. Press the MAX MIN key. The MAX - MIN indicator and the difference between the maximum - minimum value will appear in the display 6. Press the MAX MIN key. The AVG indicator and the average of the recorded values will appear in the display. 7. Press and hold the MAX MIN key for 2 seconds to exit the mode. Notes: The average value is a true average and averages up to 3000 values. If the 3000 limit is exceeded, the AVG indicator will flash and no further averaging will take place. The max and min values will continue to update. If the HOLD key is pressed during min max recording, the recording is halted until the HOLD key is pressed again. Relative Mode The relative mode displays the difference between the measured value and the value of a stored reference. 1. Press the REL key to enter the Relative mode. 2. The value in the display when the REL key is pressed will become the stored reference value and the display will indicate zero or a value close to zero (since the measured value and the reference value are the same at this point). 3. All subsequent measurements will be displayed as a value relative to the stored value. 4. The reference value may also be a value that was stored into memory using the SET Relative procedure (see the Setting a Relative Reference paragraph). 5. To use the SET relative value, press the SET key while in the Relative mode. 6. To exit the Relative mode, press and hold the REL key for 2 seconds. 5

Hi / Lo Limits Mode The Hi / Lo limits mode compares the measured value to the stored high and low limit values and gives an audible and visible indication if the measured value is outside the limits. See the setting Hi/Lo limits paragraph below to store the limits in memory. 1. Press the Hi/Lo LIMITS key to enter the mode. The display will briefly show the stored upper limit with the indicator and then the stored lower limit with the indicator before displaying the measured value. 2. The meter will sound an audible tone and blink the upper or lower limit indicator if the measured value is outside the limits. 3. The meter will ignore an OL overload reading. 4. Press the Hi/Lo LIMITS key to exit the mode. % Tolerance Mode The % Tolerance Limits mode compares the measured value to a % high and low limit based on a stored reference value and gives an audible and visible indication if the measured value is outside the limits. Any % limit can be entered in the SET % Limit mode (see paragraph below) or standard 1%, 5%, 10% and 20% symmetrical limits can be selected directly in the % Tolerance mode. 1. Press the TOL key to enter the mode. The display will briefly show the stored reference value in the main display and the small display will indicate the % difference between the measured value and the reference value. See the SET % Limit paragraph to change the reference value. 2. Press the TOL key to step through and select the 1, 5, 10 or 20% settings. The selected % will briefly appear in the small display. 3. Previously stored user defined % limits are accessed by pressing the SET key. 4. The meter will sound an audible tone and blink the upper or lower limit indicator if the measured value is outside the limits. 5. Press and hold the TOL key for 2 seconds to exit the mode. Set Limits and Open/Short Calibration Selection The SET key is used to; 1. Set Hi/Lo limits, 2. Set % limits, 3. Set Tolerance reference value and 4. Perform the Open / Short calibration. The SET mode can only be activated if no other function is active. Entering the SET mode 1. Power ON and press the SET key. 2. The display will clear, SEt will appear in the small display and a flashing TOL and flashing indicators will appear in the display. 3. The 5 keys that are now active are; Power, SET, REL, Hi/Lo, and TOL Open and Short Calibration The Open and Short function removes stray parallel and series fixture impedances from the measured value. This feature improves accuracy for very high or low impedances. (Note: Remove any leads from the meter during this procedure. Leaving them connected will add impedance to the circuit causing the calibration to fail indicated by OUT UAL appearing on the display.) 1. Press the SET key 2 times and the display will indicate CAL OPEn. 2. Remove any devices or test leads from the input terminals and press ENTER (PAL SER). After several seconds the calibration will complete and display CAL SHrt. 3. Short the input terminals and press ENTER (PAL SER). After several seconds the calibration will complete and the meter will return to normal operation. 4. Press the SET to bypass either the open or short calibration. 6

Setting Absolute Hi/Lo Limits The Hi/Lo limits set allows the user to enter an upper and lower limit value into memory for comparison to the measured value. 1. Press the SET key and then the Hi / Lo LIMITS key. The upper limit indicator will flash and the previously stored upper limit will appear with the first digit flashing. 2. Set the value of the flashing digit by pressing the appropriate numeric key. The adjustment selection will then proceed through each digit from left to right. 3. Press the - 0 key after the last digit is set to change the value of the sign to negative or positive. 4. Press the ENTER key to store the value and continue on to the lower limit adjustment. 5. The lower limit indicator will flash and the previously stored lower limit will appear. 6. Adjust the limits as described for the upper limit and press the ENTER key when complete. Setting % Tolerance Limits The % tolerance set allows the user to enter an upper and lower percentage limit into memory for comparison of the measured value to a reference value. 1. Press the SET key and then the TOL key. The TOL indicator will flash and the previously stored reference will appear with the first digit flashing. 2. To adjust the reference, set the value of the flashing digit by pressing the appropriate numeric key. The adjustment selection will then proceed through each digit from left to right. 3. Press the ENTER key to store the value and continue on to the % upper limit adjustment. The upper limit indicator will flash and the previously stored upper % limit will appear. 4. Adjust the % limit as described for the reference value and press the ENTER key when complete. The lower limit indicator will flash and the previously stored lower % limit will appear. 5. Adjust the lower % limit and press ENTER when complete. Setting a Relative Reference The relative set allows the user to store a relative reference value into memory for later use in the REL mode. 1. Press the SET key and then the REL key. The indicator will flash and the previously stored reference will appear with the first digit flashing. 2. To adjust the reference, set the value of the flashing digit by pressing the appropriate numeric key. The adjustment selection will then proceed through each digit from left to right. 3. Press the - 0 key after the last digit is set to change the value of the sign to negative or positive. 4. Press the ENTER key to store the reference value. 7

PC INTERFACE The Model 380193 LCR Meter includes a PC interface feature for use with the supplied Windows TM software. The interface allows the user to: View measurement data in real time on the PC Save, Print, and Export measurement data. Set standard and high / low limits for data analysis Generate calibration reports in spreadsheet format Plot SPC (statistical process control) analyses Database compatibility (supports ODBC) for use with: SQL server, Access TM, and other database utilities Instructions for use of the PC interface are included on the supplied Program Disk and are beyond the scope of this operation manual. For complete details and instructions refer to the HELP file on the supplied Program Disk. You, as the end user, are legally bound (EU Battery ordinance) to return all used batteries, disposal in the household garbage is prohibited! You can hand over your used batteries / accumulators at collection points in your community or wherever batteries / accumulators are sold! Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle 8

SPECIFICATIONS Capacitance @ 120Hz Range Cx accuracy DF accuracy Note 9.999mF ±(5.0% rdg + 5d) ±(10%rdg + 100/Cx + 5d) after short cal 1999.9μF ±(1.0% rdg + 5d) ±(2%rdg + 100/Cx + 5d) after short cal 199.99μF ±(0.7% rdg + 3d) 19.999μF ±(0.7% rdg + 3d) 1999.9nF ±(0.7% rdg + 3d) 199.99nF ±(0.7% rdg + 5d) after open cal 19.999nF ±(1.0% rdg + 5d) ±(2.0%rdg + 100/Cx + 5d) after open cal Capacitance @ 1kHz Range Cx accuracy DF accuracy Note 999.9μF ±(5.0% rdg + 5d) ±(10%rdg + 100/Cx + 5d) after short cal 199.99μF ±(1.0% rdg + 3d) ±(2.0%rdg + 100/Cx + 5d) after short cal 19.999μF ±(0.7% rdg + 3d) 1999.9nF ±(0.7% rdg + 3d) 199.99nF ±(0.7% rdg + 5d) 19.999nF ±(0.7% rdg + 5d) after open cal 1999.9pF ±(1.0% rdg + 5d) ±(2.0%rdg + 100/Cx + 5d) after open cal Inductance @ 120Hz Range Lx accuracy DF accuracy Note 10000H Not specified Not specified 1999.9H ±(1.0%rdg + Lx/10000 + 5d) ±(2.0%rdg + 100/Lx + 5d) after open cal 199.99H ±(0.7%rdg + Lx/10000 + 5d) ±(1.2%rdg + 100/Lx + 5d) 19.999H ±(0.7%rdg + Lx/10000 + 5d) ±(1.2%rdg + 100/Lx + 5d) 1999.9mH ±(0.7%rdg + Lx/10000 + 5d) ±(1.2%rdg + 100/Lx + 5d) 199.99mH ±(1.0%rdg + Lx/10000 + 5d) ±(3.0%rdg + 100/Lx + 5d) after short cal 19.999mH ±(2.0%rdg + Lx/10000 + 5d) ±(10%rdg + 100/Lx + 5d) after short cal Inductance @ 1kHz Range Lx accuracy DF accuracy Note 1999.9H Not specified Not specified 199.99H ±(1.0%rdg + Lx/10000 + 5d) ±(1.2%rdg + 100/Lx + 5d) after open cal 19.999H ±(0.7%rdg + Lx/10000 + 5d) ±(1.2%rdg + 100/Lx + 5d) 1999.9mH ±(0.7%rdg + Lx/10000 + 5d) ±(1.2%rdg + 100/Lx + 5d) 199.99mH ±(0.7%rdg + Lx/10000 + 5d) ±(1.2%rdg + 100/Lx + 5d) 19.999mH ±(1.2%rdg + Lx/10000 + 5d) ±(5.0%rdg + 100/Lx + 5d) after short cal 1999.9μH ±(2.0%rdg + Lx/10000 + 5d) ±(10%rdg + 100/Lx + 5d) after short cal Note: Where Lx or Cx is the the C or L reading in the display without range indication. i.e. For a reading of 18.888, use 18888 as the factor. 9

Resistance Range accuracy (1kHz & 120Hz) Note 10.000M ±(2.0%rdg + 8d) after open cal* 1.9999M ±(0.5%rdg + 5d) after open cal* 199.99k ±(0.5%rdg + 3d) 19.999k ±(0.5%rdg + 3d) 1.9999k ±(0.5%rdg + 3d) 199.99 ±(0.8%rdg + 5d) after short cal 0.020 to 19.999 ±(1.2%rdg + 8d) after short cal *Note: For resistance readings above 1MΩ, series and parallel impedances may affect readings (especially at 1kHz). This effect is often noticed on decade resistance boxes where the AC measured value can vary from the DC calibrated value. Use fixed value low inductance resistors (film or equivalent) for high resistance calibration or certification. Note: In the 20 range, effective readings must be over 20 counts. Test Frequency (accuracy) Display: Overload indication: Low battery indication: Measurement rate: Auto-power off: Operating environment: Storage environment: Power: Fuse Dimensions: Weight: 122.88Hz (±4Hz) and 1kHz (±4Hz) Dual 4 ½ digit backlit LCD OL One time per second After 10 minutes of inactivity 0 o C to 50 o C (32 o F to 122 o F), < 80% RH -20 o C to 60 o C (14 o F to 140 o F), < 80% RH, battery removed 9V battery or optional external 12V-15V @ 50mA (approx.) 0.1A/250V fast blow 19.2x9.1x5.25cm (7.56x3.6x2.1 ) 365g (12.9oz) Copyright 2011 2015 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form www.extech.com 10