Standard Practice for In-Use Resistance Testing of Gloves and Finger Cots

Similar documents
Footwear Foot Grounders Resistive Characterization (not to include static control shoes)

Worksurfaces Resistance Measurements

Application of ANSI/ESD S20.20 to Semiconductor Manufacturing. Carl Newberg River s Edge Technical Service, Inc.

American National Standard for Electric Power Systems and Equipment Voltage Ratings (60 Hertz)

Continuous On-line Measurement of Water Content in Petroleum (Crude Oil and Condensate)

American National Standard. For Wet Process Porcelain Insulators Indoor Apparatus Type ANSI/NEMA C (R2002, R2012)

NOTICE. (Formulated under the cognizance of the CTA R7 Home Networks Committee.)

Staticmaster Model 6110 Air Assist Bar Ionizer

ANSI/IEC American National Standard for Environmentally Conscious Design for Electrical and Electronic Products

1000BASE-T1 EMC Test Specification for Common Mode Chokes

AEC-Q REV A June 1, 2000

NOTICE. (Formulated under the cognizance of the CTA R4 Video Systems Committee.)

The BioBrick Public Agreement. DRAFT Version 1a. January For public distribution and comment

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Consideration of External Pressure in the Design and Pressure Rating of Subsea Equipment API TECHNICAL REPORT 17TR12 FIRST EDITION, MARCH 2015

NOTICE. (Formulated under the cognizance of the CTA R6 Portable, Handheld and In-Vehicle Electronics Committee.)

INTERNATIONAL STANDARD

NOTICE. (Formulated under the cognizance of the CTA R4 Video Systems Committee.)

Agilent G1888 Network Headspace Sampler

American National Standard. Physical Aspects of Watthour Meters Safety Standard. ANSI C Revision of ANSI C

Recommended Practice for Wet and Dry Thermal Insulation of Subsea Flowlines and Equipment API RECOMMENDED PRACTICE 17U FIRST EDITION, FEBRUARY 2015

EIA STANDARD TP-70B TEMPERATURE RISE VERSUS CURRENT TEST PROCEDURE FOR ELECTRICAL CONNECTORS AND SOCKETS EIA/ECA B. June 2007 EIA/ECA B

INTERNATIONAL STANDARD

STP-PT-054 CONCENTRATED SOLAR POWER (CSP) CODES AND STANDARDS GAP ANALYSIS

American National Standard For Roadway and Area Lighting Equipment Wireless Networked Lighting Controllers

IMPACT TESTING EXEMPTION CURVES

STP-NU ROADMAP TO DEVELOP ASME CODE RULES FOR THE CONSTRUCTION OF HIGH TEMPERATURE GAS COOLED REACTORS (HTGRS)

TETRIS User's Guide. High Impedance Active Probe DO177-1

Semiconductor Fab Electrostatic Charge Program Improvement Opportunities and Pitfalls

Charged Device Model (CDM) Component Level

EIA STANDARD TP-95. Full Mating and Mating Stability Test Procedure for Electrical Connectors EIA/ECA EIA

NATIONAL RADIO SYSTEMS COMMITTEE

201AP Charge Amplifier User Manual

TETRIS 1000 High Impedance Active Probe. Instruction Manual

Ultra-Small Footprint P-Channel FemtoFET MOSFET Test EVM

Machine Model (MM) Component Level

NEMA XR X-ray Equipment for Interventional Procedures User Quality Control Mode

AWS C7.4/C7.4M:2008 An American National Standard. Process Specification and Operator Qualification for Laser Beam Welding

NEMA Standards Publication ICS Adjustable Speed Electrical Power Drive Systems

Standard for Subsea High Integrity Pressure Protection Systems (HIPPS) API STANDARD 17O SECOND EDITION, JULY 2014

Recommended Practice for Flexible Pipe

Precision Gold Terminated Thin Film Chip Resistor Array for Conductive Gluing

QWEST Communications International Inc.

NATIONAL RADIO SYSTEMS COMMITTEE

January 7, 1997 COATED PRINTING PAPER, GS-10 1 GS-10 SECOND EDITION JANUARY 7, This standard has been superseded by Edition 2.

9 PIECE TUNGSTEN CARBIDE HOLE SAW KIT. Model 90721

STP-PT-032 BUCKLING OF CYLINDRICAL, THIN WALL, TRAILER TRUCK TANKS AND ASME SECTION XII

This is a preview - click here to buy the full publication

Progressing Cavity Pump Systems for Artificial Lift Surface-drive Systems

This document is a preview generated by EVS

AS/NZS IEC :2013

NOTICE. (Formulated under the cognizance of the CTA R6 Portable, Handheld and In-Vehicle Electronics Committee.)

T+ and T+ PRO Electrical Tester

30 Bending Brake. Model Assembly and Operating Instructions. Distributed exclusively by Harbor Freight Tools.

41P Portable Calibrator User Manual

VCS+SOCIALCARBON Project Development Process

BRADY B-731 MATTE BLACK LASER MARKABLE STATIC DISSIPATIVE POLYIMIDE LABEL STOCK

ND1603:2003/04. Specification of the KCH Metallic Path Facility. Issue 2. NICC DSL Task Group

AT Advanced Wire Tracer. Users Manual

NVMT Static Protective Laminate Installation and Maintenance

This document is a preview generated by EVS

American National Standard. For Electric Connectors Non-Sealed, Multiport Connector Systems Rated 600 Volts or Less for Aluminum and Copper Conductors

Petroleum, Petrochemical and Natural Gas Industries Steam Turbines Special-purpose Applications

American National Standard for Portable Cells and Batteries Environmental

Standard Recommended Practice. High-Voltage Electrical Inspection of Pipeline Coatings

C L - L C 4 N 1 - C

Alternating-Current High-Voltage Power Vacuum Interrupters Safety Requirements for X-Radiation Limits

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

Glossary. for Electrostatic Discharge Terminology. ESD ADV Revision of ESD ADV

9 QUICK RELEASE WOODWORKING VISE

Operator s Manual. PP016 Passive Probe

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

z48831 / z :1/ 16:1 6 GHz Multiplexer Module

TI Designs: Biometric Steering Wheel. Amy Ball TIDA-00292

Silicon Tuning Varactor Diodes in Hermetic Surface Mount Package

IAPMO IGC a Crimp-Style Metal Insert Fittings for SDR 9 PEX and PE-RT Tubing

Shell-and-Tube Heat Exchangers API STANDARD 660 NINTH EDITION, MARCH 2015

Manual of Petroleum Measurement Standards Chapter 20.3 Measurement of Multiphase Flow

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

FM Series Evaluation Module User's Guide

VGM Series. 100 & 60 W, Efficient, CV Class 2 LED Drivers for Signage Applications ORDERING INFORMATION

200B Clipper Module User Manual

EIA STANDARD TP-27B. Mechanical Shock (Specified Pulse) Test Procedure for Electrical Connectors EIA B ELECTRONIC INDUSTRIES ASSOCIATION

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

ModieLoad. Static capacitive load unit 9.8A 240vac single phase. CAUTION: Ensure only Phase to Neutral connection CAT IV 300V

Controlling Changes Lessons Learned from Waste Management Facilities 8

Low Voltage Brushed Motor System

Radio System Strobe Wizard Plus Freemask

DATA SHEET THICK FILM CHIP RESISTORS AUTOMOTIVE GRADE AC series ±5%, ±1%, ±0.5%

1523, 1524 Thermometer Readout User s Guide

Test Standard for the Determination of the Visible Entrance Field of an X-Ray Image Intensifier System

2015 RIGOL TECHNOLOGIES, INC.

PKT 512A-RO High Impedance Passive Cable Divider

INTERNATIONAL STANDARD

LOVAG GENERAL INSTRUCTION G2 MEASUREMENT UNCERTAINTY. This instruction of a general nature and does not relate to specific standards.

TX Miniature Triggered Spark Gaps Description and Use Application Note

Owner s Manual & Safety Instructions

Scotchlok UR2 Connector

AMERICAN NATIONAL STANDARD

CerePlex W. Instructions for Use. 630 Komas Drive Suite 200 Salt Lake City UT USA P F

Transcription:

for the Protection of Electrostatic Discharge Susceptible Items Standard Practice for In-Use Resistance Testing of Gloves and Finger Cots ANSI/ESD SP15.1-2005 Electrostatic Discharge Association 7900 Turin Road, Bldg. 3 Rome, NY 13440 An American National Standard Approved January 11, 2006

ESD Association Standard Practice for Protection of Electrostatic Discharge Susceptible Items In-Use Resistance Testing of Gloves and Finger Cots Approved September 11, 2005 ESD Association Inc.

CAUTION NOTICE ESD Association standards and publications are designed to serve the public interest by eliminating misunderstandings between manufacturers and purchasers, facilitating the interchangeability and improvement of products and assisting the purchaser in selecting and obtaining the proper product for his particular needs. The existence of such standards and publications shall not in any respect preclude any member or non-member of the Association from manufacturing or selling products not conforming to such standards and publications. Nor shall the fact that a standard or publication is published by the Association preclude its voluntary use by non-members of the Association whether the document is to be used either domestically or internationally. Recommended standards and publications are adopted by the ESD Association in accordance with the ANSI Patent policy. Interpretation of ESD Association Standards: The interpretation of standards in-so-far as it may relate to a specific product or manufacturer is a proper matter for the individual company concerned and cannot be undertaken by any person acting for the ESD Association. The ESD Association Standards Chairman may make comments limited to an explanation or clarification of the technical language or provisions in a standard, but not related to its application to specific products and manufacturers. No other person is authorized to comment on behalf of the ESD Association on any ESD Association Standard. DISCLAIMER OF WARRANTIES The contents of ESDA s standards and publications are provided as-is, and ESDA makes no representations or warranties, express or implied, of any kind with respect to such contents. ESDA disclaims all representations and warranties, including without limitation, warranties of merchantability, fitness for particular purpose or use, title and non-infrigement. Disclaimer of Guaranty: ESDA standards and publications are considered technically sound at the time they are approved for publication. They are not a substitute for a product seller s or user s own judgment with respect to any particular product discussed, and ESDA does not undertake to guaranty the performance of any individual manufacturers products by virtue of such standards or publications. Thus, ESDA expressly discliams any responsibility for damages arising from the use, application, or reliance by others on the information contained in these standards or publications. Limitation on ESDA s Liability: Neither ESDA, nor its members, officers, employees or other representatives will be liable for damages arising out of or in connection with the use or misuse of ESDA standards or publications, even if advised of the possibility thereof. This is a comprehensive limitation of liability that applies to all damages of any kind, including without limitation, loss of data, income or profit, loss of or damage to property and claims of third parties. Published by: Electrostatic Discharge Association 7900 Turin Road, Bldg. 3 Rome, NY 13440 Copyright 2005 by ESD Association All rights reserved No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the publisher. Printed in the United States of America ISBN: 1-58537-071-1

ESD Association Standard Practice ANSI/ESD SP15.1-2005 (This foreword is not part of ESD Association ESD SP15.1-2005) Foreword This standard practice is intended to provide test procedures for measuring the intrinsic electrical resistance of gloves and finger cots; and electrical resistance of gloves or finger cots and personnel together as a system. This standard practice applies to all gloves and finger cots used to control Electrostatic Discharge (ESD). This standard practice provides data that are relevant in the user s specific environment and application. The test uses ANSI/ESD STM11.11, Surface Resistance Measurement of Static Dissipative Planar Materials, ANSI/ESD STM 11.12, Volume Resistance Measurement of Static Dissipative Planar Materials, ANSI/ESD STM 11.13, Two-Point Resistance Measurement of Dissipative and Insulative Materials and a Constant Area and Force Electrode (CAFE) specifically designed for resistance measurements at the thumb and finger-tips. A further advantage of the CAFE is that it can be used to test finger cots as well as gloves using an identical procedure. The user of the CAFE test method should note that the in-use resistance of the glove or finger cot can be much lower than its intrinsic resistance as measured by ANSI/ESD STM11.11, STM11.12, or STM11.13. In addition, once a glove or finger cot is worn it can be measured only once because the glove or finger cot may be contaminated by a person's skin emissions. This contamination could affect the accuracy and reproducibility of further measurements on a particular glove or finger cot. It is suggested for the best reproducibility for a test group that gloves or finger cots be selected from the same lot. In the case of testing for lot-to-lot product auditing, compliance verification or variation, gloves or finger cots should be selected from multiple lots. Electrical resistance is one property that can be used to evaluate the electrostatic characteristics of gloves. However, resistance does not fully characterize these materials. An additional property to be considered in the selection and use of gloves and finger cots includes charge accumulation. Suggested test methods for personnel and glove and finger cot charging will be forthcoming. A common source of electrostatic charge in a work environment is the separation of gloves from the items being picked-up or released, resulting in the generation of electrostatic charge that can accumulate on personnel, gloves or finger cots and induced into items. The effect of this generation and accumulation of electrostatic charge can be minimized with appropriate selection of glove or finger cots. To effectively control electrostatic discharge on personnel and equipment, gloves and finger cots must be used in combination with other grounding devices. A glove material, which is conductive enough to discharge a person or an object, may also pose a safety hazard. The work performed on an ESD susceptible item often entails the use of tools and test instruments that operate at voltages high enough to cause electrical shock. The presence of a material tested using the methods described in this document will not guarantee personnel safety. This document includes test methods that may be applicable for measurement of gloves and fingers cots that reside in the conductive range, however effects due to skin resistance and electrode resistance may create significant errors. Test voltage may also be an issue for conductive materials. Beneficial comments (recommendations, additions, deletions and pertinent data, which may be of use in improving future versions of this document, should be addressed to: ESD Association Chairperson Subcommittee Workgroup - Gloves 7900 Turin Rd., Bldg. 3 Rome, NY 13440 1

At the time the work-in-process document was presented to the Standards Committee, working group 15 subcommittee had the following members: Gene Chase, Chair Electro-Tech Systems, Inc. Tom Albano ITT Space Systems Division Steve Gerken United States Air Force Johanna Morris Components Intel de Costa Rica Julius Turangan Western Digital Alan Barber Dow Reichhold Specialty Latex Arleigh Hartkopf Ansell Healthcare Carl Newberg Rivers Edge Technical Service Stan Weitz Electro-Tech Systems, Inc. Bill Casselman QRP, Inc. Tim Jarrett Guidant Corporation Rick Rodrigo SIMCO The following individuals made significant contribution to the development of SP15.1-2005: Jacquana T. Diep Advanced Micro Devices Mike Manders United States Air Force David E. Swenson Affinity Static Control Consulting, LLC Julie Vaughn Noveon, Inc

TABLE OF CONTENTS 1.0 PURPOSE AND SCOPE...1 1.1 Purpose...1 1.2 Scope...1 2.0 NORMATIVE REFERENCES...1 3.0 DEFINITION OF TERMS...1 3.1 Constant Area and Force Electrode (CAFE)...1 3.2 In-Use Resistance Test...1 4.0 PERSONNEL SAFETY...1 5.0 EQUIPMENT...2 5.1 A wrist strap with a ground cord containing an integral one megohm resister...2 5.2 A wrist strap with a ground cord that does not contain an integral one megohm resister.2 5.3 Low Resistance Meter...2 5.4 High Resistance Meter...2 5.5 Constant Area and Force Electrode (CAFE)...2 6.0 MATERIAL TESTING...2 6.1 Sample Size...2 6.2 Sample Preparation...2 6.3 Surface and Volume Resistance Measurements of Glove Material...2 6.4 Two-Point Resistance Measurements of Finger Cot Material...2 6.5 Baseline Resistance Measurement of Operator...2 6.6 Low Voltage System Resistance Test (less than 1.0 x 10 6 ohms)...3 6.7 Low Voltage System Resistance Test (greater than 1.0 x 10 6 ohms)...3 6.8 High Voltage System Resistance Test (greater than 1.0 x 10 7 ohms)...4 7.0 TEST RESULTS...4 8.0 BIBLIOGRAPHY...9 FIGURES: Figure 1. Constant Area and Force Electrode (CAFE)...5 Figure 2. Photo of CAFE Test Setup...6 Figure 3. Resistance Test Data Sheet...7 Figure 4. Constant Area and Force Electrode (CAFE) Test Data Sheet...8 3

ESD Association Standard Practice For the Protection of Electrostatic Discharge Susceptible Items - In-Use Resistance Measurement of Gloves and Finger Cots 1.0 PURPOSE AND SCOPE 1.1 Purpose This document provides test procedures for measuring the intrinsic electrical resistance of gloves and finger cots as well as their electrical resistance together with personnel as a system. The system test provides data that are relevant in the user s specific environment and application. 1.2 Scope This document applies to all gloves and finger cots used as part of a user defined Electrostatic Discharge (ESD) Control Program Applicability. This document is intended to provide test procedures for measuring the electrical resistance of gloves or finger cots. Intrinsic resistance measurements include surface, volume, and point-to-point resistance using ANSI/ESD STM11.11, 11.12, and 11.13, respectively. In-use resistance measurement of the glove/finger cot and personnel together as a system is defined using a constant area force electrode (CAFE). The resistance of the glove or finger cot may be much lower during use than its intrinsic resistance due to the interior of the glove/finger cot becoming hydrated once it is placed on the hand/finger of the operator. 2.0 NORMATIVE REFERENCES ANSI/ESD S1.1, Wrist Straps ANSI/ESD STM11.11, Surface Resistance Measurement of Static Dissipative Planar Materials ANSI/ESD STM11.12, Volume Resistance Measurement of Static Dissipative Planar Materials ANSI/ESD STM11.13, Two-Point Resistance Measurement of Dissipative and Insulative Materials ESD ADV1.0, Glossary of Terms 3.0 DEFINITION OF TERMS Terms used in this document are in accordance with the definitions found in ESD ADV1.0 Glossary of Terms. 3.1 Constant Area and Force Electrode (CAFE) An electrode designed to be held by a person's finger, gloved or ungloved, to reproducibly measure resistance from the finger to a counter electrode such as a ground strap worn on the wrist of the same hand. This electrode is suitable for measuring the resistance of a finger wearing a finger cot. See Figures 1 and 2. 3.2 In-Use (System) Resistance Test A system resistance test from a Constant Area and Force Electrode, through a glove or finger cot, to a person's finger or thumb, using a wrist strap as the second electrode.

4.0 PERSONNEL SAFETY The procedures and equipment described in this document may expose personnel to hazardous electrical conditions. Users of this document are responsible for selecting equipment that complies with applicable laws, regulatory codes and both external and internal policy. Users are cautioned that this document cannot replace or supersede any requirements for personnel safety. Ground fault circuit interrupters (GFCI) and other safety protection should be considered wherever personnel might come into contact with electrical sources. Electrical hazard reduction practices should be exercised and proper grounding instructions for equipment must be followed. 5.0 EQUIPMENT 5.1 A wrist strap with a ground cord containing an integral one megohm resistor Since an integral one megohm resistor is included in series with the wrist strap, the actual lower limit for the resistance measurement using this ground cord will be in the single-digit megohm range. The integral one megohm resistor should be verified using the test method described in ANSI/ESD S1.1. 5.2 A wrist strap with a ground cord that does not contain an integral one megohm resistor 5.3 Low Resistance Meter A DC ohmmeter shall be used for gloves that have intrinsic or in-use resistances less than 1.0 x 10 6 ohms. The DC ohmmeter shall be capable of measuring a DC resistance of 0.1 ohm through 10 megohms ± 10% with an open circuit voltage greater than 1.5 volts and less than 10 volts. 5.4 High Resistance Meter 5.4.1 The meter shall have an output voltage of 100 volts (± 5%) while under load for measurements of 1.0 x 10 6 ohms and above, and 10 volts (± 5%) while under load for measurements less than 1.0 x 10 6 ohms. 5.4.2 The meter must be capable of making measurements from 1.0 x 10 3 ohms (±10% accuracy) to 1.0 x 10 11 ohms (±10% accuracy). A power supply and ammeter, or an integrated instrument that combines those functions may be used. 5.5 Constant Area and Force Electrode (CAFE) The electrode design, materials, and specifications are shown in Figure 1. 6.0 MATERIAL TESTING 6.1 Sample Size Six specimens of each glove type or finger cot type are required for this test procedure. 6.2 Sample Preparation 6.2.1 Standard test conditions for this testing will be 23 ± 3 C, 12% ± 3% RH and 50%± 5% R.H. 6.2.2 The samples shall be conditioned at the standard conditions for 48 hours minimum. 6.3 Surface and Volume Resistance Measurements of Glove Material 5

The resistance of glove material shall be conditioned and tested using ANSI/ESD STM11.11, Surface Resistance Measurement, and ANSI/ESD S11.12, Volume Resistance Measurement at the two humidity conditions listed in 6.2.1 6.4 Two Point Resistance Measurements of Finger Cot Material The resistance of finger cot material shall be conditioned and tested using Two-Point Resistance STM11.13 at the two humidity conditions listed in 6.2.1. 6.5 Baseline Resistance Measurement of Operator The baseline resistance measurement is made with an ungloved operator. The reading verifies the functionality of the test system and establishes the minimum resistance of the operator only. All in-use testing should be performed at environmental conditions similar to those in which the gloves will be used. 6.5.1 This measurement shall be performed using the DC ohmmeter as specified in Section 5.3. 6.5.2 Select the test subject's hand of preference that will eventually be used to wear the glove/finger cot. Select the thumb and/or finger(s) to be tested. Attach the wrist cuff to the wrist of that hand. Attach the ground cord without the one megohm resistor to one input of the resistance meter. Ensure that the wrist cuff makes a good connection with the skin. An appropriate lotion may be used to assure a good connection. If a lotion is used, use care not to contaminate the gloves/finger cots during subsequent tests. 6.5.3 Attach the Constant Area and Force Electrode (CAFE) via the banana jack to the other input of the resistance meter. See Figure 2. 6.5.4 Balance the CAFE on the fingerprint side of the thumb or first finger of choice of the hand that has the wrist strap connected to it. See Figure 2. 6.5.5 Record the resistance measurement between the electrode on the bare finger and the wrist strap after 15 seconds electrification time. Repeat the test on any other digit that is selected for testing. 6.5.6 Clean the electrode (CAFE) with isopropyl alcohol prior to performing the following steps. 6.6 Low Voltage System Resistance Test (less than 1.0 x 10 6 ohms) 6.6.1 This resistance shall be measured first using an ohmmeter as specified in Section 5.3. 6.6.2 Attach the wrist cuff to the hand that will wear the glove. Attach the wrist strap cord without the one megohm resistor to one lead of the ohmmeter. Ensure that the wrist cuff makes a good connection with the skin. 6.6.3 Attach the (CAFE) to the other lead of the ohmmeter. See Figure 2. 6.6.4 Wear the glove and wait a minimum of 15 seconds to begin the electrical testing 6.6.5 Balance the CAFE on the fingerprint side of the thumb or first finger of choice of the hand wearing the glove. See Figure 2. 6.6.6 Record the resistance after 15 seconds electrification time. If the resistance measured is less than 1.0x10 6 ohms, record the resistance measurement between the electrode and the wrist cuff. Repeat the test on any other digit that was selected for testing. If the resistance is greater than 1.0x10 6 ohms, perform the testing as specified in section 6.7. 6.6.7 Repeat the above procedure for all of the test specimens at both humidity conditions. 6.7 Low Voltage System Resistance Test (greater than 1.0 x 10 6 ohms)

6.7.1 Use a meter capable of applying a voltage of 10 volts as specified in Section 5.4. 6.7.2 Attach the wrist cuff to the hand that will wear the glove. Attach the wrist strap cord without the one megohm resistor to one input of the resistance meter. Ensure that the wrist cuff makes a good connection with the skin. 6.7.3 Attach the CAFE to the other input of the resistance meter. See Figure 2. 6.7.4 Wear the glove and wait a minimum of 15 seconds to begin the electrical testing. 6.7.5 Balance the CAFE on the fingerprint side of the thumb or first finger of choice of the hand wearing the glove. See Figure 2. 6.7.6 Apply 10 volts to the electrode. Record the resistance after 15 seconds electrification time. If the resistance measured is less than 1.0 x 10 7 ohms, then record the resistance reading between the electrode and the wrist cuff. Repeat the test on any other digit that was selected for testing. If the resistance measured is greater than 1.0 x 10 7 ohms, perform testing as specified in section 6.8. 6.7.7 Repeat the above procedure for all of the test specimens at both humidity conditions. 6.8 High Voltage System, High Resistance Test greater than1.0 x 10 7 ohms. 6.8.1 Use a meter capable of applying a voltage of 100 volts as specified in Section 5.4. 6.8.2 Attach the wrist cuff to the hand that will wear the glove. Attach the wrist strap cord with the one megohm resistor to one input of the resistance meter. Ensure that the wrist cuff makes a good connection with the skin. 6.8.3 Attach the CAFE to the other input of the resistance meter. See Figure 2. 6.8.4 Wear the glove and wait a minimum of 15 seconds to begin the electrical testing. 6.8.5 Balance the CAFE on the fingerprint side of the thumb or first finger of choice of the hand wearing the glove. See Figure 2. 6.8.6 Apply 100 volts to the electrode. Record the resistance after 15 seconds of electrification time. Record the resistance measurement between the electrode and the wrist cuff. Repeat the test on any other digit that was selected for testing. 6.8.7 Repeat the above procedure for all of the test specimens at both humidity conditions. 7.0 TEST RESULTS Report all data on the attached data recording sheets. See sample data sheets, Figures 3 and 4. 7

Figure 1: Constant Area and Force Electrode (CAFE)

Figure 2: Photo of CAFE Test Setup 9

Material Measurement Data Sheet Test Facility: Date of Testing: Conditioning Temperature: C Conditioning Humidity: %R.H. Conditioning Time: Test Temperature: C Test Humidity: %R.H. Operator: Glove or Finger Cot Type: Test Voltage: Glove or Finger Cot# 1 2 3 4 5 6 Average Std. Dev. Minimum Maximum STM11.11 Surface Resistance STM11.12 Volume Resistance STM11.13 Point-to Point Resistance Glove or Finger Cot# 1 2 3 4 5 6 Average Std. Dev. Minimum Maximum STM11.11 Surface Resistance STM11.12 Volume Resistance STM11.13 Point-to Point Resistance Figure 3: Resistance Test Data Sheet

Test Facility: Date of Testing: Conditioning Temperature: C Conditioning Humidity: % R.H. Conditioning Time: Test Temperature: C Test Humidity: %R.H. Operator: Bare Finger - Baseline Resistance of Operator: No Glove # Finger 1 Finger 2 Finger 3 Finger 4 Thumb Glove Type: Test Voltage: Glove # Finger 1 Finger 2 Finger 3 Finger 4 Thumb 1 2 3 4 5 6 Average Std. Dev. Minimum Maximum Data Summary for All Fingers: Average Std. Dev. Minimum Maximum Glove Type: Test Voltage: Glove # Finger 1 Finger 2 Finger 3 Finger 4 Thumb 1 2 3 4 5 6 Average Std. Dev. Minimum Maximum Data Summary for All Fingers: Average Std. Dev. Minimum Maximum Figure 4: Constant Area and Force Electrode (CAFE) Gloves/Finger Cot Test Data Sheet 11

8.0 BIBLIOGRAPHY ESD TR 03-99 ESD Glove and Finger Cots ANSI/ESD S20.20, ESD Association Standard for the Development of an ESD Control Program for the Protection of Electrical and Electronic Parts Assemblies and Equipment (Excluding Electrically Initiated Explosive Devices). ASTM D257-93, Standard Test Methods for DC Resistance or Conductance of Insulating Materials