Output Voltage (Vfan) & Current

Similar documents
Output Voltage (Vfan) Convection-cooled (6,7) Forced-cooled (8) & Current

ECP225-A Series. 225 Watts. AC-DC Power Supplies. Models & Ratings

General. Environmental. EMC & Safety

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

ECC100 Series. -40 ºC to +75 ºC Operation. 100 W - Baseplate Cooled. High Efficiency Resonant Topology. Screw Terminals Available.

CCH400 & CCH600 Series

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

General. Environmental. EMC & Safety

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

Electrical Specifications

Electrical Specifications

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

Page 2 - ECS65 Page 13 - ECS100

Watts HCP Series

150 Watt Industrial (WLT)

Metal Case Power Supplies

C B. Models. Models 2MOPP

LFWLP W 12V 15.00A 25.00A 92%

VOF XX - XXX - X

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

Output C urrent E ffic ienc y (1)

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

For more information, please visit the product page. output. output current max (A)

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

Electrical Specifications

solo Ultra-high efficiency 1U size Xsolo Single Output Power Supply 500W W 2 FEATURES APPLICATIONS INCLUDE

VMS-300A - XX - XXX - X

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

LB115S 115W Single Output

XSOLO ULTRA-COMPACT, HIGH-EFFICIENCY 500 W AND 1000 W SINGLE OUTPUT POWER SUPPLIES

The MBC550 range is ideally suited to a wide variety of medical applications, and also where airflow is limited or not available.

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

PDAM500 Series 500W Power Supply

These medical power supplies are ideal for, monitoring, home health equipment as well as surgical devices.

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

MAD40 MULTI -OUTPUT SERIES OPP SCP OVP. 2 X 3.5 Inch AC-DC POWER SUPPLIES. UNIVERSAL INPUT RANGE UP TO 40Watts PART NUMBER STRUCTURE LOW CROSS REG.

MVAB120 Series 120W 2" x 4" AC-DC Power Supply Converter

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

Electrical Specifications. Input Current 115 VAC: 1.2 A max. 230 VAC: 0.65 A max.

Electrical Specifications. Adjustment range Main output ± 5% Total regulation (line and load) ± 2.0% ± 5.0% Turn-on 120 Vac Input 2.0 s max.

Output Current Efficiency (1)

Sirius 250/350 Watts, Single / Multi output AC-DC, modular power solution

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 115VAC to 78% at 90VAC)

CLP0112 Open Frame Power Supply Vac input; 12Vdc output; 150W Output Power

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

SF60/61P & SFU60/61P Series

Model Vnom Power Description Set Point Dynamic Vtrim Imax Remote Power (V) (W) Adjust Range (V) Range (V) (A) Sense Good

Output Voltage* (nom.)(adjustable)

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

CLP0224 Open Frame Power Supply Vac input; 24Vdc output; 200W Output Power

Electrical Specifications

M A D 65 U S 12 B - PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Power Supplies for every application

Medical / Industrial AC-DC Power Supply 1200W with 5V/2A Standby / MEB-1K2A series

Model Vnom Power Description Set Point Dynamic Vtrim Imax Remote Power (V) (W) Adjust Range (V) Range (V) (A) Sense Good

VP ELECTRONIQUE MASSY - Tel:

Ripple & Max. capacitive Output Current

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Electrical Specifications

MB120S 120W Single Output Medical Series

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Industrial Serie +600S

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

Three-phase AC input. Suitable for 3U or 5U height mounting. Single-wire current share or Droop current share

TB65 65W Single Output Test and Measurement/Industrial Series

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

POWER. NLP40 Series. Single, Dual and Triple Output. Data Sheet

Voltage Adjustment. Load Regulation

W a tts A H M S e r ie s A C D C. S p e c if ic a tio n. G e n e r a l. In p u t. E n v ir o n m e n ta l. E M C & S a f e ty.

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1. Automation Datacom IPC. Industry Measurement Telecom

MTC Series 15 W AC/DC Switching Power Supply Module Medical

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

POWER. CPS250-M Series. 250 Watt AC-DC Power Supplies. Data Sheet. Total Power: 250 Watts Input Voltage: V # of Outputs: Single

General. Efficiency Isolation. Dimensions Net Weight. Safety & EMC

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load

Output Voltage nom. (adjustable)

300µA max at 264Vac & 63Hz (normal condition, 500µA Single Fault Condition) Adjustment Range V V. Channel

Low Profile. 3 Year Warranty

POWER. CPS250-M Series. 250 Watt AC-DC Power Supplies. Data Sheet. Total Power: 250 Watts Input Voltage: V # of Outputs: Single

Model Selection Model Output Current Total OVP Number Class Volts (Convection Cooled) Efficiency 1 Ripple &Noise 2 Regulation Threshold

Transcription:

C-DC Power Supplies 50/80/250/350 Watts Convection/Forced-cooled Ratings Universal 85-264 VC Input IT & Medical Safey pprovals (Class I & II) < 0.5 W Standby Power (50 & 80 Models) -40 C to +70 C Operation Remote On/Off Class B Emissions 3 Year Warranty The GCS Series has been designed to minimise the no load power consumption and maximise efficiency in order to facilitate equipment design to the latest environmental legislation. pproved for Class I and Class II applications, this range of single output C-DC power supplies are packaged in an industry standard 3.0" x 5.0" x.42" package and achieves EN550/22 Level B emissions compliance whilst maintaining very low earth leakage currents, making them suitable for a wide range of U and other industrial, IT and medical applications. Dimensions: GCS50/GCS80/GCS250/GCS350: 5.00 x 3.00 x.42 (27.0 x 76.2 x 36.3 mm) (-C): 5.50 x 3.48 x.70 (39.7 x 88.5 x 43.2 mm) (-TF): 5.50 x 3.48 x 2.20 (39.7 x 88.5 x 57.8 mm) (-EF): 6.35 x 3.48 x.70 (6.3 x 88.5 x 43.2 mm) (350-EF): 6.00 x 3.50 x.75 (52.4 x 88.9 x 44.4 mm) The series has single output versions from 2 V to 56 VDC, dual-fusing for compliance with IEC6060- and feature minimal excess heat generation as efficiencies reach 94%. They will deliver up to 350 W of power over an operating range of -40 C and up to +70 C and are available with a number of cover options. Models & Ratings Output Voltage V Output Current V Convection-cooled (6) Forced-cooled (7 CFM) Output Voltage (Vfan) & Current Max Output Power Model Number (,2,3,4,5) 2.0 VDC 9.2 2.5 2.0 VDC/0.6 57 W GCS50PS2 5.0 VDC 7.3 0.0 2.0 VDC/0.6 57 W GCS50PS5 24.0 VDC 4.6 6.3 2.0 VDC/0.6 57 W GCS50PS24 28.0 VDC 3.9 5.4 2.0 VDC/0.6 57 W GCS50PS28 48.0 VDC 2.3 3.2 2.0 VDC/0.6 57 W GCS50PS48 2.0 VDC 2.5 5.0 2.0 VDC/0.6 87 W GCS80PS2 5.0 VDC 0.0 2.0 2.0 VDC/0.6 87 W GCS80PS5 24.0 VDC 6.3 7.5 2.0 VDC/0.6 87 W GCS80PS24 28.0 VDC 5.4 6.4 2.0 VDC/0.6 87 W GCS80PS28 48.0 VDC 3. 3.7 2.0 VDC/0.6 87 W GCS80PS48 2.0 VDC 5.0 8.8 2.0 VDC/0.6 232 W GCS250PS2 5.0 VDC 2.0 5.0 2.0 VDC/0.6 232 W GCS250PS5 24.0 VDC 7.5 0.4 2.0 VDC/0.6 257 W GCS250PS24 28.0 VDC 6.4 8.9 2.0 VDC/0.6 257 W GCS250PS28 48.0 VDC 3.7 5.2 2.0 VDC/0.6 257 W GCS250PS48 56.0 VDC 3.2 4.5 2.0 VDC/0.6 257 W GCS250PS56 2.0 VDC 6.7 29.2 2.0 VDC/0.6 350 W GCS350PS2 5.0 VDC 3.3 23.4 2.0 VDC/0.6 350 W GCS350PS5 24.0 VDC 8.3 4.6 2.0 VDC/0.6 350 W GCS350PS24 28.0 VDC 7. 2.5 2.0 VDC/0.6 350 W GCS350PS28 48.0 VDC 4.2 7.3 2.0 VDC/0.6 350 W GCS350PS48 56.0 VDC 3.6 6.25 2.0 VDC/0.6 350 W GCS350PS56. dd suffix -C for convection cooled cover, e.g. GCS50PS2-C. 2. dd suffix -EF for fan cooled cover with end fan e.g. GCS50PS2-EF. Note Vfan output no longer available. 3. dd suffix -TF for fan cooled cover with top fan, e.g. GCS50PS2-TF. Note Vfan output no longer available. 4. dd suffix -R for remote on/off, e.g. GCS50PS2-R, GCS50PS2-RC with convection cover or GCS50PS2-REF/GCS50PS2-RTF with fan covers, (remote on/off is standard on GCS350 models). 5. GCS250PS2-C & GCS250PS5-C models derate 20% when convection cooled. 6. GCS350 convection rating quoted at 40 C, others at 50 C. 7. GCS350-C models derate 5% when convection-cooled at 40 C.

C-DC Power Supplies Input Characteristic Minimum Typical Maximum Units & Conditions Input Voltage - Operating 85 5/230 264 VC Derate output power <90 VC. See fig. Input Frequency 47 50/60 63 Hz Power Factor >0.9 230 VC, 00% load.5/0.7 GCS50: 5/230 VC.8/0.8 GCS80: 5/230 VC Input Current - Full Load 2.2/. GCS250 2-5 V models: 5/230 VC 2.4/.2 GCS250 24 V models: 5/230 VC 3.6/.8 GCS350: 5/230 VC Inrush Current 80 230 VC cold start 25 C 0.5 ll GCS50 & GCS80 (including -R Models) 2.3 GCS50 & GCS80 -R Models with inhibit activated 5 ll GCS250 (including -R Models) 5V C No Load Input Power 3 ll GCS250 (including -R Models) 230V C W GCS250 -R Models with inhibit activated 5V C 3 GCS250 -R Models with inhibit activated 230V C 0.5 vailable for GCS250 models, contact sales 4 GCS350: 5/230 VC 60/20 200 GCS50: 5/230 VC/50 Hz Typ., 264 VC/60 Hz Max. Earth Leakage Current 95/85 250 GCS80: 5/230 VC/50 Hz Typ., 264 VC/60 Hz Max. µ 95/85 250 GCS250: 5/230 VC/50 Hz Typ., 264 VC/60 Hz Max. 95/85 250 GCS350: 5/230 VC/50 Hz Typ., 264 VC/60 Hz Max. Input Protection GCS50/80: F3.5 /250 V internal fuse in both lines. GCS250/350: F5.0 /250 V internal fuse in both lines. Input Voltage Derating Curve Figure 80 GCS80PSxx forced-cooled 70 250 240 Forced-cooled (24 V / 28 V / 48 V) 60 230 50 220 Output Power (W) 40 30 20 0 00 GCS80PSxx convection-cooled GCS50PSxx forced-cooled GCS50PSxx convection-cooled Output Power (W) 20 200 90 80 70 Forced-cooled (2 V / 5 V) Convection-cooled (ll models) 90 60 0 85 90 00 220 230 240 250 260 264 270 Input Voltage (VC) GCS50 & GCS80 0 85 90 00 220 230 240 250 260 264 270 Input Voltage (VC) GCS250 360 340 Forced-cooled 320 300 280 Output Power (W) 260 240 220 200 80 60 Convection-cooled (at 40 C) Convection-cooled (at 50 C) 0 85 90 00 220 230 240 250 260 264 270 Input Voltage (VC) GCS350 2

C-DC Power Supplies Output Characteristic Minimum Typical Maximum Units & Conditions Output Voltage - V 2 56 VDC See Models and Ratings table Initial Set ccuracy ± (V) & ±5 (Vfan) % 50% load, 5/230 VC Output Voltage djustment -V ±2 % Via potentiometer. See mech. details, Vfan will track Minimum Load 0 Start Up Delay 0.5 s 5/230 VC full load 20 GCS50 Models 6/8 GCS80 Models Hold Up Time 25 ms GCS250PS2 (225W) 7 GCS250 Other Models (250W) 7 GCS350 Drift ±0.2 % fter 20 min warm up Line Regulation ±0.5 % 90-264 VC Load Regulation ±0.5 (V), ±5 (Vfan) % 0-00% load Transient Response - V 4 % Recovery within % in less than 500 µs for a 50-75% and 75-50% load step Over/Undershoot - V 0 % Ripple & Noise - V % pk-pk 20 MHz bandwidth, 2V Models.5% max Overvoltage Protection - V 0 40 % Vnom DC. Output, recycle input to reset Overload Protection - V 0 50 % I nom See fig. 2. Trip and Restart Short Circuit Protection - V Continuous Temperature Coefficient 0.05 %/ C Overtemperature Protection C Not fitted Output Overload Characteristic Figure 2 GCS80PS2 example (other similar). 2 0 Output Voltage (V) 8 6 4 Trip & Restart 2 0 0 2 4 6 8 0 2 4 6 8 20 22 24 Output Load () 3

C-DC Power Supplies General Characteristic Minimum Typical Maximum Units & Conditions Efficiency Isolation: Input to Output Input to Ground Output to Ground 93 % 230 VC Full load (see fig.3-5 ) 80 Plus Silver ll models except 2 V models 80 Plus Bronze 2 V models 4000 VC 500 VC 500 VC Switching Frequency 60 200 PFC Converter khz 90 50 Main Converter 7.4 GCS50 8.8 GCS80 Power Density 2. W/in 3 GCS250 6.4 GCS350 Mean Time Between Failure 569 khrs MIL-HDBK-27F, Notice 2 +25 C GB Weight: Open Frame 0.65 (0.29) lb (kg) End Fan Unit.30 (0.59) lb (kg) Top Fan Unit.5 (0.52) lb (kg) Covered Unit.05 (0.48) lb (kg) Efficiency Vs Load Figure 3 2 V Models 00.00% 90.00% 80.00% 70.00% Efficiency (%) 60.00% 50.00% 40.00% 30.00% 20.00% 0.00% 5V 230V 0.00% 20% 25% 50% 67% 75% 00% Load % Figure 4 24 V Models 00.00% 90.00% 80.00% Efficiency (%) 70.00% 60.00% 50.00% 40.00% 30.00% 5V 230V 20.00% 0.00% 0.00% 20% 25% 50% 67% 75% 00% Load % Figure 5 48 V Models 00.00% 90.00% 80.00% 70.00% Efficiency (%) 60.00% 50.00% 40.00% 30.00% 5V 230V 20.00% 0.00% 0.00% 20% 25% 50% 67% 75% 00% Load % 4

C-DC Power Supplies Signals & Controls Characteristic Remote Sense Remote On/Off (-R models) (Standard on GCS350 models) Inhibit Enable & Conditions Compensates for 0.5 V total voltage drop The inhibit lo (pin 4), should be pulled below 0.4 V to switch V & Vfan off. Open circuit or >4 V to switch on (see fig. 6) With the inhibit lo (pin 4) pulled low as detailed above, connecting inhibit hi (pin 5) to inhibit lo (pin 4) will enable V & V fan output. (see fig. 7) Remote On/Off (Inhibit) Figure 6 Remote On/Off (Enable) Figure 7 POWER SUPPLY Inhibit Hi Pin 5 POWER SUPPLY Inhibit Lo Pin 4 Inhibit Lo Pin 4 0 V 0 V Signals Connector Signals Connector Environmental Characteristic Minimum Typical Maximum Units & Conditions Operating Temperature -40 +70 C See derating curve, fig. 8 Storage Temperature -40 +85 C Forced Cooled >0 W GCS50 Cooling 7 Forced Cooled >50 W GCS80 CFM Forced Cooled >80 W GCS250 2 GCS350 Humidity 5 95 %RH Non-condensing Operating ltitude 5000 m Shock ±3 x 30g shocks in each plane, total 8 shocks. 30g = ms (+/-0.5msec), half sine. Conforms to EN60068-2-27 & EN60068-2-47 Vibration Single axis 0-500 Hz at 2g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6 Thermal Derating Curve Figure 8 00 Output Load (%) 50 Some specification parameters may not be met 0-40 -20 0 +50 +70 mbient Temperature (ºC) 5

C-DC Power Supplies EMC: Emissions Phenomenon Standard Test Level Criteria & Conditions Conducted EN550/22 Class B Radiated EN550/22 Class B Class Class B GCS50 GCS80/GCS250/GCS350 GCS80 & GCS250 with 3 turns of output cable through added ferrite core. (Manufacturer: Fair - Rite Products Corp, Part No: 2643800502) Harmonic Fluctuations EN6000-3-3 EMC: Immunity Phenomenon Standard Test Level Criteria & Conditions Low Voltage PSU EMC EN6204-3 High severity level as below Class ll models > 50 W GCS50 Harmonic Current EN6000-3-2 > 50 W GCS80 Class C > 80 W GCS250 >25 W GCS350 Radiated EN6000-4-3 3 EFT EN6000-4-4 3 Surges EN6000-4-5 Installation class 3 Conducted EN6000-4-6 3 Dips and Interruptions EN55024 (00 VC) EN55024 (240 VC) EN6060--2 (00 VC) EN6060--2 (240 VC) Dip >95% (0 VC), 8.3ms Dip 30% (70 VC), 46ms Dip >95% (0 VC), 460ms Dip >95% (0 VC), 0.0ms Dip 30% (68 VC), 500ms Dip >95% (0 VC), 5000ms Dip >95% (0 VC), 0.0ms Dip 60% (40 VC), 00ms Dip 30% (70 VC), 500ms Dip >95% (0 VC), 5000ms Dip >95% (0 VC), 0.0ms Dip 60% (96 VC), 00ms Dip 30% (68 VC), 500ms Dip >95% (0 VC), 5000ms B B B B B B Derate Output Power to 85 W (GCS50) Derate Output Power to 90 W (GCS80) Derate Output Power to 20 W (GCS250) Derate Output Power to 50 W (GCS350) Safety pprovals Safety gency Safety Standard & Conditions CB Report IEC60950-:2005 Ed 2 Information Technology IEC6060- Ed 3 Including Risk Management Medical UL UL60950- (2007), CS 22.2 No.60950--:08 Information Technology NSI/MI ES6060-:2005 & CS C22.2, No.6060-:08 Medical TUV EN60950-:2006 Information Technology EN6060-/2:2006 Medical CE LVD & RoHS Equipment Protection Class Class I & Class II See safety agency conditions of acceptibility for details Primary to Secondary Primary to Earth Secondary to Earth Means of Protection 2 x MOPP (Means of Patient Protection) x MOPP (Means of Patient Protection) x MOPP (Means of Patient Protection) Category IEC6060- Ed 3 6

C-DC Power Supplies Mechanical Details GCS50 5.0 (27.0) Note: Mounting points should be connected together for optimum EMI performance 4.5 (5.57) 0.20 (5.).42 (36.3) Q3 T C45 IRFLOW 3.00 (76.2) 2.5 (54.6) 2.55 (64.7) L3 C6 Q C23 C28 0.6 (5.6).8 (29.8) 2.40 (6.0) 0.20 (5.) 0.25 Faston Ground Tab 4 x 0.56 (3.96) mounting holes ø.32 (7.92) clearance top and bottom 0.4 (3.5) 0.8 (4.6) 0.5 (3.8) SMD Component Height GCS80 5.0 (27.0) Note: Mounting points should be connected together for optimum EMI performance 4.5 (5.57) 0.20 (5.).42 (36.3) Q3 T C45 IRFLOW 3.00 (76.2) 2.5 (54.6) 2.55 (64.7) L3 C6 Q C23 C28 0.6 (5.6).8 (29.8) 2.40 (6.0) 0.20 (5.) 0.25 Faston Ground Tab 4 x 0.56 (3.96) mounting holes ø.32 (7.92) clearance top and bottom 0.4 (3.5) 0.8 (4.6) 0.5 (3.8) SMD Component Height Input Connector J Molex pn. 09-65-2038 Line 2 Neutral. ll dimensions in inches (mm). 2. Tolerance.xx = ±0.02 (0.50);.xxx = ±0.0 (0.25) 3. Weight: 0.65 lbs (0.29 kg) Output Connector J2 Molex pn. 09-65-2068 +V 2 +V 3 +V 4 RTN 5 RTN 6 RTN Fan Connector J3 Molex pn. 22-04-02 Fan +(2 V) 2 Fan - 4. J mates with Molex Housing Pn. 09-50-03. J2 mates with Molex Housing Pn. 09-50-06 and both with Molex series 594 crimp terminals. J4 mates with JST Housing Pn. PHDR-0VS and with JST SPHD-00T-P0.5 crimp terminals. J3 mates with Molex Housing Pn. 59-0200 and with Molex series 50802 crimp terminals. Signal Connector J4 JST PN B0B-PHDSS +Sense 2 -Sense 3 XP Internal Use 4 Inhibit LO 5 Inhibit HI 6 N/C 7 N/C 8 N/C 9 N/C 0 N/C 7

C-DC Power Supplies Mechanical Details GCS250 2-5 V models 5.0 (27.0) Note: Mounting points should be connected together for optimum EMI performance 4.5 (5.57) 0.20 (5.).42 (36.3) Q3 T C45 IRFLOW 3.00 (76.2) 2.5 (54.6) 2.55 (64.7) L3 C6 Q C23 C28 0.6 (5.6).8 (29.8) 2.40 (6.0) 0.20 (5.) 0.25 Faston Ground Tab 4 x 0.56 (3.96) mounting holes ø.32 (7.92) clearance top and bottom 0.4 (3.5) 0.8 (4.6) 0.5 (3.8) SMD Component Height GCS250 Other models 5.0 (27.0) Note: Mounting points should be connected together for optimum EMI performance 4.5 (5.57) 0.20 (5.).42 (36.3) Q3 T C45 IRFLOW 3.00 (76.2) 2.5 (54.6) 2.55 (64.7) L3 C6 Q C23 C28 0.6 (5.6).8 (29.8) 2.40 (6.0) 0.20 (5.) 0.25 Faston Ground Tab 4 x 0.56 (3.96) mounting holes ø.32 (7.92) clearance top and bottom 0.4 (3.5) 0.8 (4.6) 0.5 (3.8) SMD Component Height Input Connector J Molex pn. 09-65-2038 Line 2 Neutral. ll dimensions in inches (mm). 2. Tolerance.xx = ±0.02 (0.50);.xxx = ±0.0 (0.25) 3. Weight: 0.65 lbs (0.29 kg) 4. J mates with Molex Housing Pn. 09-50-03. J2 mates with Molex Housing Pn. 09-50-06 and both with Molex series 594 crimp Output Connector J2 Molex pn. 09-65-2068 +V 2 +V 3 +V 4 RTN 5 RTN 6 RTN Fan Connector J3 Molex pn. 22-04-02 Fan +(2 V) 2 Fan - terminals. J4 mates with JST Housing Pn. PHDR-0VS and with JST SPHD- 00T-P0.5 crimp terminals. J3 mates with Molex Housing Pn. 59-0200 and with Molex series 50802 crimp terminals. Signal Connector J4 JST PN B0B-PHDSS +Sense 2 -Sense 3 XP Internal Use 4 Inhibit LO 5 Inhibit HI 6 N/C 7 N/C 8 N/C 9 N/C 0 N/C 8

C-DC Power Supplies Mechanical Details GCS350 model 0.2 (5.72) 5.0 (27.0) 4.5 (5.57).49 (37.8) 0.40 (0.2) 3.0 (76.2).8 (46.7) 2.5 (64.7) J 2 0.22 (5.72) 0.20 (5.) 4 x ø.56 (3.96) mounting hole ø.32 (7.92) clearance top and bottom 0.25 faston ground tab 0.6 (4.) 2 + - 3 5 4 2 J3 J4 0.6 (5.6) 0.8 (4.6).8 (29.8) 0.5 (2.6).7 (44.8) 0.5 (3.8) SMD Component height + - M3 Screw M3 screw terminal bus bar Standard on 2/5 V models Optional on all other models 0.20 (5.) 0.29 (7.4) 6 2 2 6 3 5 4 2 J2 J3 2.4 (6.0) J4 2 7 J2 J3 3 5 J4 4 2.6 (40.6) 6 Position single row Standard on 24/28/48/56 V models 2 Position dual row Optional on 2/5 V models Input Connector J Molex pn. 09-65-2038 Line 2 Neutral Output Connector 6 position J2 Molex pn. 09-65-2068 +V 2 +V 3 +V 4 RTN 5 RTN 6 RTN. ll dimensions in inches (mm). 2. Tolerance.xx = ±0.02 (0.50);.xxx = ±0.0 (0.25) 3. Weight: 0.65 lbs (0.29 kg) Output Connector 2 position J2 Molex pn. 39-28-820-3 RTN 4-6 +V 7-9 RTN 0-2 +V Fan Connector J3 Molex pn. 22-04-02 Fan +(2 V) 2 Fan - 4. J mates with Molex Housing Pn. 09-50-03. 6 position single row J2 mates with Molex Housing Pn. 09-50-06 and both with Molex series 594 crimp terminals. 2 position dual row J2 mates with Molex Housing Pn. 39-0-225 and with Molex series 5556 crimp terminals. J3 mates with Molex Housing Pn. 59-0200 and with Molex series 50802 crimp terminals. J4 mates with JST Housing Pn. PHDR-0VS and with JST SPHD-00T-P0.5 crimp terminals. Signal Connector J4 JST PN B0B-PHDSS +Sense 2 -Sense 3 XP Internal Use 4 Inhibit LO 5 Inhibit HI 6 N/C 7 N/C 8 N/C 9 N/C 0 N/C 9

2 6 GCS Series C-DC Power Supplies Mechanical Details Covered (-C) 0.39 (0.0) 0.93 (23.7) 4.72 (20.0) 4 x M3 x 0.5 THD 0.6 (4.0) max screw penetration 5.50 (39.7) J 2.39 (60.7) 2 2 0 3.48 (88,5) 2.64 (67.0) 0.85 (2.6) J2 J3 J4 0.25 Faston Ground Tab 0.45 (.4) 0.43 (0.8) 0.45 (.4).70 (43.2) 4 x M3 x 0.5 THD 0.6 (4.0) max screw penetration.96 (50.0) 0.39 (0.0) 4.72 (20.0) 0.76 (9.3) Input Connector J Molex pn. 09-65-2038 Line 2 Neutral. ll dimensions in inches (mm). 2. Tolerance.xx = ±0.02 (0.50);.xxx = ±0.0 (0.25) 3. J mates with Molex Housing Pn. 09-50-03. J2 mates with Molex Housing Pn. 09-50-06 and both with Molex series 594 crimp terminals. J4 mates with JST Housing Pn. Output Connector J2 Molex pn. 09-65-2068 +V 2 +V 3 +V 4 RTN 5 RTN 6 RTN Fan Connector J3 Molex pn. 22-04-02 Fan +(2 V) 2 Fan - PHDR-0VS and with JST SPHD-00T-P0.5 crimp terminals. J3 mates with Molex Housing Pn. 59-0200 and with Molex series 50802 crimp terminals. 4. In class II installations the cover is floating and provides x MOPP (2 x MOOP). 5. Weight:.05 lbs (0.48 kg) Signal Connector J4 JST PN B0B-PHDSS +Sense 2 -Sense 3 XP Internal Use 4 Inhibit LO 5 Inhibit HI 6 N/C 7 N/C 8 N/C 9 N/C 0 N/C 0

6 GCS Series C-DC Power Supplies Mechanical Details Top Fan (-TF) 0.39 (0.0) 0.93 (23.7) 4.72 (20.0) 2 x M3 x 0.5 THD 0.6 (4.0) max screw penetration 5.5 (39.7) 2.39 (60.7) 2 J 2 2 0 J2 J3 J4 0.85 (2.6) 3.48 (88,5) 2.64 (67.0) 0.25 Faston Ground Tab 0.45 (.4) 0.43 (0.8) 0.45 (.4) 2.2 (57.8).7 (43.2) 4 x M3 x 0.5 THD 0.6 (4.0) max screw penetration.96 (50.0) 0.76 (9.3) 0.39 (0.0) 4.72 (20.0) Input Connector J Molex pn. 09-65-2038 Line 2 Neutral. ll dimensions in inches (mm). 2. Tolerance.xx = ±0.02 (0.50);.xxx = ±0.0 (0.25) 3. J mates with Molex Housing Pn. 09-50-03. J2 mates with Molex Housing Pn. 09-50-06 and both with Molex series 594 crimp terminals. J4 mates with JST Housing Pn. Output Connector J2 Molex pn. 09-65-2068 +V 2 +V 3 +V 4 RTN 5 RTN 6 RTN Fan Connector J3 Molex pn. 22-04-02 Fan +(2 V) 2 Fan - PHDR-0VS and with JST SPHD-00T-P0.5 crimp terminals. J3 mates with Molex Housing Pn. 59-0200 and with Molex series 50802 crimp terminals. 4. In class II installations the cover is floating and provides x MOPP (2 x MOOP). 5. Weight:.5 lbs (0.52 kg) Signal Connector J4 JST PN B0B-PHDSS +Sense 2 -Sense 3 XP Internal Use 4 Inhibit LO 5 Inhibit HI 6 N/C 7 N/C 8 N/C 9 N/C 0 N/C

6 End Fan (-EF) GCS50/80/250 6.35 (6.3).90 (48.2) J 2 GCS Series C-DC Power Supplies Mechanical Details 0.43 (0.8) J4 2 0 3.48 (88.5) 2.63 (66.9) J3 J2 2 0.84 (2.5).0 [27.8] 5.50 (39.7) 0.45 (.4) 0.45 (.4) 2 x M3 x 0.5 THD 0.6 (4.0) max screw penetration 0.25 Faston (Right ngle) Ground Tab 0.93 (23.7).70 (43.2) 0.39 (0.0) 4.72 (20.0) 0.76 (9.3) 4 x M3 x 0.5 THD 0.6 (4.0) max screw penetration.96 (50.0) 0.39 (0.0) 4.72 (20.0) Input Connector J Molex pn. 09-65-2038 Line 2 Neutral. ll dimensions in inches (mm). 2. Tolerance.xx = ±0.02 (0.50);.xxx = ±0.0 (0.25) 3. J mates with Molex Housing Pn. 09-50-03. J2 mates with Molex Housing Pn. 09-50-06 and both with Molex series 594 crimp terminals. J4 mates with JST Housing Pn. Output Connector J2 Molex pn. 09-65-2068 +V 2 +V 3 +V 4 RTN 5 RTN 6 RTN Fan Connector J3 Molex pn. 22-04-02 Fan +(2 V) 2 Fan - PHDR-0VS and with JST SPHD-00T-P0.5 crimp terminals. J3 mates with Molex Housing Pn. 59-0200 and with Molex series 50802 crimp terminals. 4. In class II installations the cover is floating and provides x MOPP (2 x MOOP). 5. Weight:.30 lbs (0.59 kg) Signal Connector J4 JST PN B0B-PHDSS +Sense 2 -Sense 3 XP Internal Use 4 Inhibit LO 5 Inhibit HI 6 N/C 7 N/C 8 N/C 9 N/C 0 N/C 2

C-DC Power Supplies Mechanical Details End Fan (-EF) GCS350 0.56 (4.) 0.6 (5.5) 6.00 (52.4).75 (44.4) 0.70 (7.7).75 (44.4).48 (37.7) 0.99 (25.) 3.50 (88.9) 3.50 (88.9) M3 Screw L N G Input Terminal Block Dinkle P/N DT-2C-02W-03 0.68 (7.2) 4.72 (20.0) 0.88 (22.3) 2 X M3 X 0.5 THD 0.6 (4.0) Max screw penetration 0.68 (7.2) 4.72 (20.0) 0.75 (8.9) 2.00 (50.8) 4 X M3 X 0.5 THD 0.6 (4.0) Max screw penetration Input Connector J Dinkle PN DJ-26-D2W-03 Line 2 Neutral 3 Output Connector 6 position J2 Molex pn. 09-65-2068 +V 2 +V 3 +V 4 RTN 5 RTN 6 RTN. ll dimensions in inches (mm). 2. Tolerance.xx = ±0.02 (0.50);.xxx = ±0.0 (0.25) 3. Weight: 0.65 lbs (0.29 kg) Output Connector 2 position J2 Molex pn. 39-28-820-3 RTN 4-6 +V 7-9 RTN 0-2 +V Fan Connector J3 Molex pn. 22-04-02 Fan +(2 V) 2 Fan - 4. 6 position single row J2 mates with Molex Housing Pn. 09-50-06 and both with Molex series 594 crimp terminals. 2 position dual row J2 mates with Molex Housing Pn. 39-0-225 and with Molex series 5556 crimp terminals. J3 mates with Molex Housing Pn. 59-0200 and with Molex series 50802 crimp terminals. J4 mates with JST Housing Pn. PHDR-0VS and with JST SPHD-00T-P0.5 crimp terminals. Signal Connector J4 JST PN B0B-PHDSS +Sense 2 -Sense 3 XP Internal Use 4 Inhibit LO 5 Inhibit HI 6 N/C 7 N/C 8 N/C 9 N/C 0 N/C 3

C-DC Power Supplies Thermal Considerations In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below must not be exceeded. Temperature should be monitored using K type thermocouples placed on the hottest part of the component (out of direct air flow). See Mechanical Details for component locations. Temperature Measurements (t mbient 50 C) Component Max Temperature C T Coil L3 Coil Q Body Q3 Body C6 C23 20 C 20 C 20 C 20 C 05 C 05 C -- Service Life The estimated service life of the GCS Series is determined by the cooling arrangements and load conditions experienced in the end application. Due to the uncertain nature of the end application this estimated service life is based on the actual measured temperature of a key capacitors with in the product when installed by the end application. The worst case of the two figures should be taken as the indicative service life in 24/7 operation. The graph below expresses the estimated lifetime of a given component temperature and assumes continuous operation at this temperature. Estimated Service Life vs Component Temperature GCS50/80 GCS250 GCS350 85000 20000 70000 65000 Lifetime (Hrs) 00000 80000 60000 40000 20000 Lifetime (Hrs) 60000 50000 40000 30000 20000 0000 Lifetime (Hrs) 45000 25000 05000 85000 65000 45000 25000 0 05 95 85 75 65 55 0 05 95 85 75 65 55 5000 05 95 85 75 65 55 C6 Temperature ( C) C6 Temperature ( C) C6 Temperature ( C) GCS50/80 GCS250 GCS350 Lifetime (Hrs) 85000 65000 45000 25000 05000 85000 65000 45000 25000 5000 05 95 85 75 65 C23 Temperature ( C) 55 Lifetime (Hrs) 85000 65000 45000 25000 05000 85000 65000 45000 25000 5000 05 95 85 75 65 C23 Temperature ( C) 55 Lifetime (Hrs) 85000 65000 45000 25000 05000 85000 65000 45000 25000 5000 05 95 85 75 65 C23 Temperature ( C) 55 2-Feb-5