Gamma Scientific Display Measurement Systems

Similar documents
NEAR EYE DISPLAY (NED) SPECTRORADIOMETER SYSTEMS DATASHEET

Model S471-LED Optometer

Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration

PHOTO RESEARCH, INC. PR-730 / PR-735 and PR-740 / PR-745 SpectraScan

Achieving 100,000 : 1 contrast measurement

Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup.

LM Test Report. For. T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D

Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup.

We bring quality to light. MAS 40 Mini-Array Spectrometer

CS-2000/2000A. Spectroradiometer NEW

L Test Report. LED TUBE 1odel: LED11.5WT8/48/850-PET-G7DR

BTS2048-VL-CP-ILED-B-IS-1.0-HL

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

BTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser.

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

FPD IN-LINE SPECTRAL TESTING SOLUTION

Miniaturized Spectroradiometer

High-Accuracy Luminance & Chromaticity Measurement Comparable to Many Spectroradiometers

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

Broadbandradiometer specbos 1211

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

Multispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2

JETI Specbos Instruments

Spectroradiometer specbos 1201

LM Test. for LED. Cabinet

specification display & lighting hera spectrometer

Imaging Photometer and Colorimeter

Report No.: HZ h. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

Report No.: HZ c

LED Tester BTS256-LED

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A

Report No.: HZ a. 60 mins Note. 4000K, frosted lens Table 1: Executive Data Summary

Report No.: HZ d

OL Series 426 Low Light Level lntegrating Sphere Calibration Standards

Photometry and Light Measurement

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

Catalog Number UPC Number LED Spot Bullet Flood Light 42W 4204 Lumens White

Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

PR-655 PR-670 PR-680 and PR-680L SpectraScan

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LED Lighting Flux and Color Measurement System (LFC)

Sample Report. IES LM Test Report. LED Lamp 001. Test results reported for: Orb Optronix report: LEDC WG. Original issue date:

NVLAP LAB CODE:

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

NVLAP LAB CODE:

NVLAP LAB CODE:

BTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED.

ISS-30-VA. Product tags: Integrating Sphere Source. Gigahertz-Optik GmbH 1/5

Product tags: VIS, Spectral Data, Color Temperature, CRI, Bilirubin, PAR, Scotopic, Luminous Color, Photometry, General lighting

NVLAP LAB CODE:

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Product tags: VIS, Spectral Data, Color Temperature, CRI, Waterproof, WiFi, Luminous Color, LED, Photometry, General lighting

LEADING THE WAY in Light Measurement Systems

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Morris Products 53 Carey Road, Queensbury, NY 12804

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

The Right Tool for a Spectrum of Applications

Catalog Number UPC Number LED Spot Bullet Flood Light 15W 1620 Lumens Bronze

Table of Content. Fiber-Coupled LED s Light-Guide-Coupled LED s LED Collimator Sources Low-cost LED Spot Lights...

BTS256-EF. Product tags: VIS, Spectral Measurement, Waterproof, WiFi. Gigahertz-Optik GmbH 1/7

IES LM MEASUREMENT AND TEST REPORT. Test Model: SRLED-RTUS24-4K. Jeanne Han/Safety Manager

NVLAP LAB CODE:

IESNA LM-79: Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE. Dec 08, 2014

IESNA LM-79: Measurement and Test Report for Jiawei Technology (USA) Limited Lincoln Ave.Hayward, CA USA.

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

illumia Plus Temperature Controlled Light Measurement Systems

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC. Sep 09, 2013 LED8WMR16/38/830-DIM. David Zhang BTR

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG

Chameleon Spectroradiometer

NVLAP LAB CODE:

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

QPL ID # PLG2YNJ831VZ

Dark Sky Wallpack 50W. General ACD12 Aluminum Heat Sink High Light Transmittance Polycarbonate, Anti-UV and Fire Resistant Finish:

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

Diogen Lighting,Inc 14 Inverness Drive East,Ste.E-128 Englewood, CO T8L W BEST Test Service Shenzhen Co., Ltd.

Checked X.CAO

A High-Speed Imaging Colorimeter LumiCol 1900 for Display Measurements

Checked X.CAO

High Precision CCD Spectroradiometer & Integrating Sphere Test System LPCE-2(LMS-9000B) Brochure. Global Office of Lisun Electronics Inc.

IESNA LM-79: Measurement and Test Report for Green Creative Ltd. Room , New Victory House, Wing Lok Street, Central, HONG KONG

REVOLUTION LIGHTING TECHNOLOGIES INC

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

Cat# LED Classic Large Wall-Pack

The Art of Light Measurement. Avantes BV Apeldoorn, The Netherlands

LED14.5WPAR30S/FL/827-DIM

Transcription:

Gamma Scientific Display Measurement Systems 9925 Carroll Canyon Road San Diego, CA 92131 858-279-8034 contact@gamma-sci.com www.gamma-sci.com

Since 1961 Gamma Scientific has produced LED, display and light measurement test solutions for production and R&D environments. Gamma Scientific instruments are trusted by leading global organizations that require high-speed, precision measurements and custom configurations for the most challenging environments. Gamma Scientific also operates a NVLAP accredited laboratory that performs LM-79/ LM-80 LED testing and is ISO 17025 compliant. NVLAP Lab Code 200823-0. To view the complete line of test and measurement solutions from Gamma Scientific, please visit our website at www.gamma-sci.com. Gamma Scientific 9925 Carroll Canyon Road San Diego, CA 92131 858-279-8034 contact@gamma-sci.com www.gamma-sci.com With over 50 years of experience in developing commercial light measurement instruments, Gamma Scientific is trusted by the world s leading organizations to provide accurate and repeatable test systems. Gamma Scientific Display Measurement Systems can capture spectral measurements of displays in milliseconds with ultra-low uncertainty. Any application which demands high sensitivity in the blue-light region, such as LED backlit displays, will benefit from the systems back-thinned CCD technology. Display Measurement Systems from Gamma Scientific are available in six models covering multiple spectral ranges and featuring two different spectroradiometer configurations. Interchangeable system components are available for easy customization and integration. Gamma Scientific s powerful Light Touch spectral data acquisition and analysis software package, available in both engineering/ R&D and QC/production line versions, powers all Display Measurement Systems. Original system calibration is performed in Gamma Scientific s NVLAP accredited laboratory using NIST-traceable standards. Gamma Scientific spectroradiometers can be selfcalibrated and do not have to be returned to the factory for calibration.

Since 1961 Gamma Scientific has produced LED, display and light measurement test solutions for production and R&D environments. Gamma Scientific instruments are trusted by leading global organizations that require high-speed, precision measurements and custom configurations for the most challenging environments. Gamma Scientific also operates a NVLAP accredited laboratory that performs LM-79/ LM-80 LED testing and is ISO 17025 compliant. NVLAP Lab Code 200823-0. To view the complete line of test and measurement solutions from Gamma Scientific, please visit our website at www.gamma-sci.com. Gamma Scientific 9925 Carroll Canyon Road San Diego, CA 92131 858-279-8034 contact@gamma-sci.com www.gamma-sci.com FEATURES Luminance measurements down to 0.0005 cd/m 2 Contrast measurements to 1,000,000:1 Superior wavelength and color accuracy via low thermal expansion co efficient materials Near-real-time measurement High resolution: 0.4 nm/pixel Spectral ranges: 310-930 nm, 360-1100 nm, and 360-800 nm Low polarization error User-selectable half power bandwidth Six different measurement apertures AVS Viewing System or Reflex Viewing System USB interface Windows-based control/analysis software NIST-traceable accuracy Self-calibrated, system never has to be returned to lab for calibration

Since 1961 Gamma Scientific has produced LED, display and light measurement test solutions for production and R&D environments. Gamma Scientific instruments are trusted by leading global organizations that require high-speed, precision measurements and custom configurations for the most challenging environments. Gamma Scientific also operates a NVLAP accredited laboratory that performs LM-79/ LM-80 LED testing and is ISO 17025 compliant. NVLAP Lab Code 200823-0. To view the complete line of test and measurement solutions from Gamma Scientific, please visit our website at www.gamma-sci.com. FEATURES Luminance measurements down to 0.0015 cd/m2 Superior wavelength and color accuracy via low thermal expansion coefficient materials Near-real-time measurement High resolution: 0.3 nm/pixel Spectral ranges: 250-900 nm, 360-900 nm, and 360-1100 nm Low polarization error User-selectable half power bandwidth Six different measurement apertures AVS Viewing System USB interface Windows-based control/analysis software NIST-traceable accuracy Self-calibrated, system never has to be returned to lab for calibration Gamma Scientific 9925 Carroll Canyon Road San Diego, CA 92131 858-279-8034 contact@gamma-sci.com www.gamma-sci.com

Detector and Wavelength Specifications Model Number GS-1290-DMS-1 GS-1290-DMS-2 GS-1290-DMS-3 Spectral Range (nominal) 360-930 nm 360-1100 nm 310-930 nm with quartz optics 350-1100 nm with quartz optics 360-800 nm Wavelength Resolution 0.6 nm/element 0.9 nm/element 0.4 nm/element Spectral Bandwidth Built-In User Selectable Half-Power Bandwidth (HPBW) Bold is factory setting 10 nm 20 nm 10 nm 5.0 nm 10 nm 5.0 nm 2.5 nm 5.0 nm 2.5 nm 1.8 nm 2.7 nm 1.4 nm 1.2 nm 1.8 nm 1.0 nm Wavelength Repeatability 0.02 nm 0.03 nm 0.02 nm Wavelength Accuracy +/- 0.25 nm +/- 0.25 nm +/- 0.25 nm Stray Light Less than 1 x 10-4 (at 8 times the HPBW from a HeNe laser line) Polarization Error 1 < 1% Measuring Angle 5, 2, 1, 0.5, 0.3, or 0.1 (user-selectable) Min. measuring distance 69 mm with macro lens. Single calibration valid from 100 mm to infinity. Integration Time 0.008 to 520 seconds Computer Interface USB 2.0 Control Software Analysis in CIE1931 XYZ and xy; CIE1976 UCS u v ; CIE1976 L*u*v* and L*a*b*; CIE 1964 XYZ Operating Temp / Humidity 5 to 35 C / relative humidity 0 to 90%, non-condensing Size 12.1 L x 6 W x 11.8 H (30.8 cm L x 15.1 cm W x 29.9 cm H) Weight 20 lbs. (9.1 kg) Power AC Adapter (100-240 V~, 50-60 Hz) 1: Measuring 100% linearly polarized light through a Glan-Thompson Prism 2: Sensitivities are for a 10:1 signal-to-noise ratio based on the percent coefficient of variance measuring the luminance of a CIE Illuminant A source. 3: The information contained in this data sheet is based on Gamma Scientific's internal evaluation and is subject to change at any time without notice.

Sensitivity and Accuracy Chart 2 Aperture Size 5 2 1 0.5 0.33 0.1 Sensitivity (cd/m 2 ) 0.00015 to 36,500 0.00022 to 53,600 0.0009 to 220,000 0.0034 to 829,000 0.016 to 3,900,000 0.09 to 21,900,000 x,0 (0.0015-0.05 cd/m 2 ) (0.002-0.07 cd/m 2 ) (0.009-0.3 cd/m 2 ) (0.03-1.1 cd/m 2 ) (0.16-5.1 cd/m 2 ) (0.9-29 cd/m 2 ) Chromaticity Accuracy (GS-1290-DMS-1) (0.05-800 cd/m 2 ) (800-36,500 cd/m 2 ) (0.07-1,150 cd/m 2 ) (1,150-53,600 cd/m 2 ) (0.3-4,700 cd/m 2 ) (4,700-220,000 cd/m 2 ) (1.1-17,750 cd/m 2 ) (17,750-829,000 cd/m 2 ) (5.1-83,500 cd/m 2 ) (83,500-3.9M cd/m 2 ) (29-470,000 cd/m 2 ) (470,000-21.9M cd/m 2 ) Chromaticity Accuracy (GS-1290-DMS-2) x,y: ±0.0040 (0.0015-0.05 cd/m 2 ) (0.05-800 cd/m 2 ) (800-36,500 cd/m 2 ) x,0 (0.0015-0.05 cd/m 2 ) (0.002-0.07 cd/m 2 ) (0.07-1,150 cd/m 2 ) (1,150-53,600 cd/m 2 ) (0.002-0.07 cd/m 2 ) (0.009-0.3 cd/m 2 ) (0.3-4,700 cd/m 2 ) (4,700-220,000 cd/m 2 ) (0.009-0.3 cd/m 2 ) (0.03-1.1 cd/m 2 ) (1.1-17,750 cd/m 2 ) (17,750-829,000 cd/m 2 ) (0.03-1.1 cd/m 2 ) (0.16-5.1 cd/m 2 ) (5.1-83,500 cd/m 2 ) (83,500-3.9M cd/m 2 ) (0.16-5.1 cd/m 2 ) (0.9-29 cd/m 2 ) (29-470,000 cd/m 2 ) (470,000-21.9M cd/m 2 ) (0.9-29 cd/m 2 ) Chromaticity Accuracy (GS-1290-DMS-3) Size @ 69 mm (2.72") Size @ 100 mm (3.94") Size @ 69 mm (2.72") Size @ 100 mm (3.94") (0.05-800 cd/m 2 ) (800-36,500 cd/m 2 ) (0.07-1,150 cd/m 2 ) (1,150-53,600 cd/m 2 ) (0.3-4,700 cd/m 2 ) (4,700-220,000 cd/m 2 ) Canon 50 mm Compact Macro 1:2.5 (1.1-17,750 cd/m 2 ) (17,750-829,000 cd/m 2 ) (5.1-83,500 cd/m 2 ) (83,500-3.9M cd/m 2 ) (29-470,000 cd/m 2 ) (470,000-21.9M cd/m 2 ) ø 9.83 mm (0.387 ) ø 3.93 mm (0.155 ) ø 1.97 mm (0.077 ) ø 0.98 mm (0.039 ) ø 0.65 mm (0.026 ) ø 0.20 mm (0.008 ) ø 10.49 mm (0.413 ) ø 4.20 mm (0.165 ) ø 2.10 mm (0.083 ) ø 1.05 mm (0.041 ) ø 0.69 mm (0.027 ) ø 0.21 mm (0.008 ) ø 28.26 mm (1.113") ø 11.30 mm (0.445") ø 5.65 mm (0.223") ø 2.83 mm (0.111") ø 1.86 mm (0.073") ø 0.57 mm (0.022 ) Canon 50mm Compact Macro 1:2.5 with Life-size Converter EF; MAG = 1.46 ø 4.83 mm (0.190 ) ø 1.93 mm (0.076 ) ø 0.97 mm (0.038 ) ø 0.48 mm (0.019 ) ø 0.32 mm (0.013 ) ø 0.10 mm (0.004 ) ø 6.86 mm (0.270 ) ø 2.74 mm (0.108 ) ø 1.37 mm (0.054 ) ø 0.69 mm (0.027 ) ø 0.45 mm (0.018 ) ø 0.14 mm (0.005 ) ø 19.37 mm (0.763 ) ø 7.75 mm (0.305 ) ø 3.87 mm (0.153 ) ø 1.94 mm (0.076 ) ø 1.28 mm (0.050 ) ø 0.39 mm (0.015 ) Tamron 180 mm Macro 1:3.5 ø 10.49 mm (0.413 ) ø 4.20 mm (0.165 ) ø 2.10 mm (0.083 ) ø 1.05 mm (0.041 ) ø 0.69 mm (0.027 ) ø 0.21 mm (0.008 ) 1: Measuring 100% linearly polarized light through a Glan-Thompson Prism 2: Sensitivities are for a 10:1 signal-to-noise ratio based on the percent coefficient of variance measuring the luminance of a CIE Illuminant A source. 3: The information contained in this data sheet is based on Gamma Scientific's internal evaluation and is subject to change at any time without notice.

Detector and Wavelength Specifications Model Number GS-1220-DMS-0 GS-1220-DMS-1 GS-1290-DMS-2 Spectral Range (nominal) 250-900 nm 360-900 nm 360-1100 nm UV-VIS VIS VIS-NIR Wavelength Resolution 0.32 nm/element 0.32 nm/element 0.35 nm/element Spectral Bandwidth Built-In User Selectable Half-Power Bandwidth (HPBW) Bold is factory setting 10 nm 10 nm 10 nm 5.0 nm 5.0 nm 5.0 nm 2.5 nm 2.5 nm 2.5 nm 1.4 nm 1.4 nm 1.4 nm 1.0 nm 1.0 nm 1.0 nm Wavelength Repeatability 0.02 nm 0.02 nm 0.02 nm Wavelength Accuracy +/- 0.1 nm +/- 0.1 nm +/- 0.1 nm Stray Light Less than 1 x 10-4 (at 8 times the HPBW from a HeNe laser line) Polarization Error 1 < 1% Measuring Angle 5, 2, 1, 0.5, 0.3, or 0.1 (user-selectable) Min. measuring distance 69 mm with macro lens. Single calibration valid from 100 mm to infinity. Integration Time 2 μsec to 2.67 sec Computer Interface USB 2.0 Control Software Analysis in CIE1931 XYZ and xy; CIE1976 UCS u v ; CIE1976 L*u*v* and L*a*b*; CIE 1964 XYZ Operating Temp / Humidity 5 to 35 C / relative humidity 0 to 90%, non-condensing Size 5.25 H x 12.00 W x 10.20 L (13.34 cm H x 30.48 cm W x 25.91 cm L) Weight 10 lbs. (4.6 kg) Power AC Adapter (100-240 V~, 50-60 Hz) 1: Measuring 100% linearly polarized light through a Glan-Thompson Prism 2: Sensitivities are for a 10:1 signal-to-noise ratio based on the percent coefficient of variance measuring the luminance of a CIE Illuminant A source. 3: The information contained in this data sheet is based on Gamma Scientific's internal evaluation and is subject to change at any time without notice.

Sensitivity and Accuracy Chart 2 Aperture Size 5 2 1 0.5 0.33 0.1 Sensitivity (cd/m 2 ) 0.0015 to 1,125 0.002 to 1,650 0.009 to 6,750 0.03 to 28,100 0.16 to 120,000 0.9 to 675,000 Chromaticity Accuracy x,0 (0.0015-0.05 cd/m 2 ) (0.05-1,125 cd/m 2 ) (0.002-0.07 cd/m 2 ) (0.07-1,650 cd/m 2 ) (0.009-0.3 cd/m 2 ) (0.3-6,750 cd/m 2 ) (0.03-1.1 cd/m 2 ) (1.1-28,100 cd/m 2 ) (0.16-5.1 cd/m 2 ) (5.1-120,000 cd/m 2 ) (0.9-29 cd/m 2 ) (29-675,000 cd/m 2 ) Size @ 69 mm (2.72") Size @ 100 mm (3.94") Size @ 69 mm (2.72") Size @ 100 mm (3.94") Canon 50 mm Compact Macro 1:2.5 ø 9.83 mm (0.387 ) ø 3.93 mm (0.155 ) ø 1.97 mm (0.077 ) ø 0.98 mm (0.039 ) ø 0.65 mm (0.026 ) ø 0.20 mm (0.008 ) ø 10.49 mm (0.413 ) ø 4.20 mm (0.165 ) ø 2.10 mm (0.083 ) ø 1.05 mm (0.041 ) ø 0.69 mm (0.027 ) ø 0.21 mm (0.008 ) ø 28.26 mm (1.113") ø 11.30 mm (0.445") ø 5.65 mm (0.223") ø 2.83 mm (0.111") ø 1.86 mm (0.073") ø 0.57 mm (0.022 ) Canon 50mm Compact Macro 1:2.5 with Life-size Converter EF; MAG = 1.46 ø 4.83 mm (0.190 ) ø 1.93 mm (0.076 ) ø 0.97 mm (0.038 ) ø 0.48 mm (0.019 ) ø 0.32 mm (0.013 ) ø 0.10 mm (0.004 ) ø 6.86 mm (0.270 ) ø 2.74 mm (0.108 ) ø 1.37 mm (0.054 ) ø 0.69 mm (0.027 ) ø 0.45 mm (0.018 ) ø 0.14 mm (0.005 ) ø 19.37 mm (0.763 ) ø 7.75 mm (0.305 ) ø 3.87 mm (0.153 ) ø 1.94 mm (0.076 ) ø 1.28 mm (0.050 ) ø 0.39 mm (0.015 ) Tamron 180 mm Macro 1:3.5 ø 10.49 mm (0.413 ) ø 4.20 mm (0.165 ) ø 2.10 mm (0.083 ) ø 1.05 mm (0.041 ) ø 0.69 mm (0.027 ) ø 0.21 mm (0.008 ) 1: Measuring 100% linearly polarized light through a Glan-Thompson Prism 2: Sensitivities are for a 10:1 signal-to-noise ratio based on the percent coefficient of variance measuring the luminance of a CIE Illuminant A source 3: Standard Operating Range for Gamma Scientific Instruments- Temperature: Minimum: 0 C (32 F) - Maximum: 35 C (95 F); Relative Humidity (Non- Condensing): Minimum: 20% - Maximum 70% 4: The information contained in this data sheet is based on Gamma Scientific's internal evaluation and is subject to change at any time without notice 5: Revised on April 9, 2015