Variations in breathing patterns increase low frequency contents in HRV spectra

Similar documents
HIGH FREQUENCY FILTERING OF 24-HOUR HEART RATE DATA

Chapter 5. Frequency Domain Analysis

Biosignal filtering and artifact rejection, Part II. Biosignal processing, S Autumn 2017

Relation between HF HRV and Respiratory Frequency

Spectral Analysis and Heart Rate Variability: Principles and Biomedical Applications. Dr. Harvey N. Mayrovitz

Uncertainty factors in time-interval measurements in ballistocardiography

Validation of the Happify Breather Biofeedback Exercise to Track Heart Rate Variability Using an Optical Sensor

Frequency Domain Analysis for Assessing Fluid Responsiveness by Using Instantaneous Pulse Rate Variability

Towards the standardization of ballistocardiography systems for J-peak timing measurement

A Comprehensive Model for Power Line Interference in Biopotential Measurements

Variability Analysis for Noisy Physiological Signals: A Simulation Study

Heart-Rate Variability and Event-Related ECG in Virtual Environments

Estimating Frequency Response Characteristics of Human Baroreflex System

Analysis and Interpretation of HRV Data with Particular. Principal Investigator Dorn VA Medical Center (OEF OIF) and Dorn Research Institute

Improved Heart Rate Variability Signal Analysis from the Beat Occurrence Times According to the IPFM Model

Can Very High Frequency Instantaneous Pulse Rate Variability Serve as an Obvious Indicator of Peripheral Circulation?

6.555 Lab1: The Electrocardiogram

Heart rate variability analysis using robust period detection

Quantifying errors in spectral estimates of HRV due to beat replacement and resampling

Computer Evaluation of Exercise Based on Blood Volume Pulse (BVP) Waveform Changes

An algorithm to estimate the transient ST segment level during 24-hour ambulatory monitoring

Non-contact video based estimation for heart rate variability using ambient light by extracting hemoglobin information

Effect of acupuncture on the autonomic nervous system as evaluated by noncontact heart rate variability measurement

An Approach to Detect QRS Complex Using Backpropagation Neural Network

Denoising of ECG signal using thresholding techniques with comparison of different types of wavelet

Biosignal filtering and artifact rejection. Biosignal processing I, S Autumn 2017

Accurate Identification of Periodic Oscillations Buried in White or Colored Noise Using Fast Orthogonal Search

INTERFERENCE REDUCTION IN ECG RECORDINGS BY USING A DUAL GROUND ELECTRODE

Arterial pulse waves measured with EMFi and PPG sensors and comparison of the pulse waveform spectral and decomposition analysis in healthy subjects

(b) What are the differences between FM and PM? (c) What are the differences between NBFM and WBFM? [9+4+3]

Comparison between the Fourier and Wavelet methods of spectral analysis applied to stationary and nonstationary heart period data

Development of Electrocardiograph Monitoring System

Fundamentals of Time- and Frequency-Domain Analysis of Signal-Averaged Electrocardiograms R. Martin Arthur, PhD

Design on Electrocardiosignal Detection Sensor

ON THE VALIDITY OF THE NOISE MODEL OF QUANTIZATION FOR THE FREQUENCY-DOMAIN AMPLITUDE ESTIMATION OF LOW-LEVEL SINE WAVES

HRV spectrum bands & single peak Coherence

International Journal of Emerging Technologies in Computational and Applied Sciences (IJETCAS)

AC-Coupled Front-End for Biopotential Measurements

MULTIPLE PULSE WAVE MEASUREMENT TOWARD ESTIMATING CONDITION OF HUMAN ARTERIES

Solution to Chapter 4 Problems

Chapter 2 Analog-to-Digital Conversion...

Quantitative Comparison of Time Frequency Distribution for Heart Rate Variability Using Performance Measure

Bivariate phase-rectified signal averaging a novel technique for cross-correlation analysis in noisy nonstationary signals

Michael F. Toner, et. al.. "Distortion Measurement." Copyright 2000 CRC Press LLC. <

Model : KY202M. Module Features. Heart Rate Variability Processing Module

Compensation of Analog-to-Digital Converter Nonlinearities using Dither

Module 1: Introduction to Experimental Techniques Lecture 2: Sources of error. The Lecture Contains: Sources of Error in Measurement

Dimensional analysis of the audio signal/noise power in a FM system

Low distortion signal generator based on direct digital synthesis for ADC characterization

BME 405 BIOMEDICAL ENGINEERING SENIOR DESIGN 1 Fall 2005 BME Design Mini-Project Project Title

Low-cost photoplethysmograph solutions using the Raspberry Pi

understand compatibility of photoplethysmographic pulse rate variability with electrocardiogramic heart rate variability

FOR PROOFREADING ONLY

Angle Modulated Systems

Protocol to assess robustness of ST analysers: a case study

Non-contact Video Based Estimation of Heart Rate Variability Spectrogram from Hemoglobin Composition

SHF Communication Technologies AG. Wilhelm-von-Siemens-Str. 23D Berlin Germany. Phone Fax

Response spectrum Time history Power Spectral Density, PSD

Biomedical Engineering Evoked Responses

Removal of Line Noise Component from EEG Signal

Outline. Communications Engineering 1

ANALOGUE TRANSMISSION OVER FADING CHANNELS

Local Oscillator Phase Noise and its effect on Receiver Performance C. John Grebenkemper

RHRV Quick Start Tutorial

Breath Amplitude Modulation of Heart Rate Variability in Normal Full Term Neonates

Design of FIR Filter for Efficient Utilization of Speech Signal Akanksha. Raj 1 Arshiyanaz. Khateeb 2 Fakrunnisa.Balaganur 3

Real Time Spatiotemporal Biological Stress Level Checking

Problem Sheet 1 Probability, random processes, and noise

ECE 201: Introduction to Signal Analysis

NOISE REDUCTION TECHNIQUES IN ECG USING DIFFERENT METHODS Prof. Kunal Patil 1, Prof. Rajendra Desale 2, Prof. Yogesh Ravandle 3

Multilayer Perceptrons for Time Series Prediction: A Case Study on Heart Signals

Dynamics of Mobile Toroidal Transformer Cores

Artifact Removal from the Radial Bioimpedance Signal using Adaptive Wavelet Packet Transform

New Features of IEEE Std Digitizing Waveform Recorders

Transfer Function (TRF)

Introduction to Wavelet Transform. Chapter 7 Instructor: Hossein Pourghassem

CME312- LAB Manual DSB-SC Modulation and Demodulation Experiment 6. Experiment 6. Experiment. DSB-SC Modulation and Demodulation

Wavelet Coherence Reveals Entrainment of Heart Rate Variability Among People Involved in Group Activities

Subsurface Resistivity Measurements Using Square Waveforms

Islamic University of Gaza. Faculty of Engineering Electrical Engineering Department Spring-2011

Biosignal filtering and artifact rejection. Biosignal processing, S Autumn 2012

Speech, music, images, and video are examples of analog signals. Each of these signals is characterized by its bandwidth, dynamic range, and the

Microwave Doppler Radar for Heart Beat Detection Versus Electrocardiogram: A Validation Approach

FFT 1 /n octave analysis wavelet

WARPED FILTER DESIGN FOR THE BODY MODELING AND SOUND SYNTHESIS OF STRING INSTRUMENTS

Estimation of Predetection SNR of LMR Analog FM Signals Using PL Tone Analysis

Phase Noise Modeling of Opto-Mechanical Oscillators

Improving histogram test by assuring uniform phase distribution with setting based on a fast sine fit algorithm. Vilmos Pálfi, István Kollár

III Lead ECG Pulse Measurement Sensor

EENG473 Mobile Communications Module 3 : Week # (12) Mobile Radio Propagation: Small-Scale Path Loss

SHORT PULSE CHARACTERIZATION OF NONLINEARITIES IN POWER ULTRASOUND TRANSDUCERS.

Elderly Health Care System of Systems by Non-Contacted Multiple Sensors

Digital Signal Processing

1. Explain how Doppler direction is identified with FMCW radar. Fig Block diagram of FM-CW radar. f b (up) = f r - f d. f b (down) = f r + f d

Biomedical Instrumentation B2. Dealing with noise

EET 223 RF COMMUNICATIONS LABORATORY EXPERIMENTS

Structure of Speech. Physical acoustics Time-domain representation Frequency domain representation Sound shaping

(i) Understanding of the characteristics of linear-phase finite impulse response (FIR) filters

Notes on Noise Reduction

The Effect of Quantization Upon Modulation Transfer Function Determination

Transcription:

Physiol. Meas. 21 (2000) 417 423. Printed in the UK PII: S0967-3334(00)13410-0 Variations in breathing patterns increase low frequency contents in HRV spectra M A García-González, C Vázquez-Seisdedos and R Pallàs-Areny Instrumentation and Bioengineering Division (DIB), Department of Electronic Engineering (DEE), Universitat Politècnica de Catalunya (UPC), C/Jordi Girona 1 3, Campus Nord Edifici C-4, 08034 Barcelona, Spain Department of Telecommunication, Universidad de Oriente, 90900 Santiago de Cuba, Cuba E-mail: magarcia@eel.upc.es Received 20 April 2000 Abstract. This paper shows that variations in breathing patterns broaden heart rate variability (HRV) spectral bands and increase the power amplitude of low-frequency bands. Because of these influences, spectral markers for HRV signals, such as the quotient between spectral power at different frequency bands, should be compared only under controlled breathing conditions or after considering the effect of variations in breathing patterns. Keywords: respiration heart rate variability, spectral analysis, respiratory sinus arrhythmia, controlled 1. Introduction Heart rate variability (HRV) analysis has become a useful tool to study the relationship between the autonomic nervous system (ANS) and the cardiovascular system (CS). HRV is usually studied from the RR time series, either by time-domain methods (Kleiger et al 1993), nonlinear dynamics (Wada et al 1993), or spectral analysis (Pagani et al 1986). HRV analysis has been applied, for example, to study the risk of cardiac electrical instability after myocardial infarction (Bigger et al 1991), to diagnose diabetic neuropathy (Pagani et al 1988), to assess re-innervation after cardiac transplantation (Sands et al 1989) and to evaluate exercise training (Arai et al 1989). Spectral analysis describes the frequency distribution of signal power. Analysis of rhythmic events in the RR time series permits us to infer the state of biological oscillators that modulate the CS, the sympathetic and vagal efferent activity, humoral factors and the sinus node (Task Force 1996). Usually, the power spectrum of the RR time series is divided into three bands: the very-low-frequency (VLF) band, the low-frequency (LF) band, and the high-frequency (HF) band. Vagal activity is the major contributor to the HF component mostly because of the respiratory sinus arrhythmia (Pomeranz et al 1985). The LF band is assumed to reflect sympathetic modulations or both sympathetic and vagal activity. In HRV spectral analysis, the biological oscillators that modulate the CS are commonly considered to remain invariable. Nevertheless, the amplitude and frequency of that modulation is seldom stationary in practice. 0967-3334/00/030417+07$30.00 2000 IOP Publishing Ltd 417

418 M A García-González et al This work investigates the effects of breathing-frequency variations in the spectral quantification of HRV signals. Respiratory activity causes a modulation in RR time series at the breathing frequency, which is termed respiratory sinus arrhythmia. The amplitude of this modulation depends on vagal tone (Kollai and Mizsei 1990) and on the breathing frequency itself (Womack 1971) (high breathing frequencies yield smaller amplitude oscillations in the RR spectrum than low breathing frequencies). Hence, changes in breathing frequency should be reflected in the RR time series as a modulation in both amplitude and frequency, and result in a modified spectrum of the RR time series as compared to that obtained during periodic breathing. Consequently, we can expect that variations in breathing patterns change spectral markers in both the HF and LF bands of RR time series spectra. These changes exclusively due to the breathing pattern (i.e. the cause) should not be mistaken for abnormal changes in HRV (i.e. changes in the cause-to-effect relationship). This paper shows that variations of the breathing frequency increase the LF/HF index. First, the theoretical spectrum of FM and low-pass filtered signals is presented in order to substantiate the working hypothesis. Next, spectral estimation methods of actual time series are briefly discussed in order to justify the spectral analysis method used here. Finally, simulation and experimental results are presented and discussed in order to draw some conclusions. 2. Theoretical spectrum of FM and low-pass filtered signals The spectrum of a sine wave whose frequency is f c and variance σ 2 c, x c (t) = σ c 2 cos(2πf c t) (1) is a spectral peak located at f c.iff c varies with time, the signal spectrum changes. Consider for example the frequency modulated (FM) signal x FM (t) = σ ) c cos (2πf c t +2π x m (λ) dλ (2) 2 where is the frequency deviation and x m (t) is the modulating signal with variance σm 2 and probability distribution function (PDF) p xm (x). The quasi-static approximation (Peebles 1976) shows that the two-sided power spectrum of x FM (t) when the frequency of variation is slow compared to f c is S xfm x FM (f ) = σ 2 c σ 2 m 2 [ ( ) ( )] f fc f + fc p xm + p xm. (3) Therefore, frequency variation implies a broadening of the spectral peak, which depends on the PDF of the modulating signal. Since there is a low-pass filtering action between breathing frequency and heart rate fluctuation (Womack 1971), we are interested in the spectrum of the output y(t) of that filter, which is S y (f ) = σ 2 c σ 2 m 2 [ ( ) ( )] f fc f + fc p xm + p xm H LP (f ) 2. (4) That is, the power spectrum of y(t)is that of x FM weighted by the filter transfer function. Hence, the low-frequency components of x FM (t) will be enhanced as compared to the high-frequency components.

Breathing patterns influence HRV spectral bands 419 3. Spectral estimation of RR time series The spectral estimation of time series must consider the finite number of samples available and the sampling process itself. In an RR time series (tachogram), the information is provided by each QRS arrival, which results in non-uniform sampling, leading to spectral artifacts (Mateo and Laguna 2000). Resampling the tachogram with splines yields a uniformly sampled and interpolated RR time series, which avoids artifacts. Spectral estimation methods can be either non-parametric, such as the periodogram and its modifications (Barlett, Welch and Blackman Tukey periodograms), or parametric (AR, MA and ARMA modelling). The need for high-frequency resolution, the finite length of the time series, the smoothness of the spectra and its capability of identifying periodical components immersed in noise favoured the extended use of parametric estimation methods. Nevertheless, non-parametric methods are more accurate than parametric methods to quantify power distribution in frequency bands (Mateo and Laguna 2000), which is the basis for markers in HRV spectral analysis. Hence, we estimate the spectra from the periodogram (squared modulus of the FFT) of the tachogram resampled and interpolated by cubic splines. Finally, frequency bands in HRV variability analysis must be delimited according to the intended application. Since the narrower the LF band, the smaller the LF/HF index, we normalize the LF/HF index to the signal bandwidth according to LF/HF n = S LF BW HF. (5) S HF BW LF We are interested in variations in the LF/HF n index because of variations in breathing frequency. Therefore, we will analyse RR time series during different breathing patterns that involve respiratory frequencies from 0.1 Hz to 0.2 Hz. Consequently, we define the three following frequency bands (see figure 1): 0.03 Hz VLF band 0.03 Hz < 0.09 Hz LF band (6) 0.09 Hz <f <0.4 Hz HF band. According to this definition, BW LF = 0.06 Hz and BW HF = 0.31 Hz. 4. Results from simulated tachograms The first step in assessing how variations in respiratory frequency affect the LF/HF n index is to analyse simulated tachograms that include different beat-to-beat interval modulations. A 5 min fragment of a periodic RR signal (in milliseconds) with f c = 0.15 Hz is RR p (n) = 1000 + 100 cos(2π 0.15n) n [1,...,300] (7) where n is the heartbeat number. Hence, the shortest RR interval is 900 ms, the longest is 1100 ms and the average is 1000 ms. A 5 min fragment of an FM modulated RR signal (in milliseconds) with the same maximum, minimum and mean of RR p and with f c = 0.15 Hz, = 0.05 Hz and f m = 0.01 Hz is RR FM (n) = 1000 + 100 cos [ 2π 0.15n +2π 0.05 n i=1 ] cos(2π 0.01i) n [1,...,300]. (8) Both tachograms are resampled at 4 Hz prior to the spectral estimation. Figure 1 shows that the respective frequency spectra are quite different in spite of the average breathing frequency

420 M A García-González et al Figure 1. Spectra of simulated RR FM and RR p. Table 1. Normalized power-spectra ratio index (LF/HF n ) for the RR time series under periodic (RR p ) and FM modulated (RR FM ) breathing after low-pass filtering with different cut-off frequencies. 0.05 Hz 0.07 Hz 0.10 Hz 0.13 Hz 0.15 Hz 0.20 Hz Periodic 796 10 6 6.9 10 6 0.7 10 6 5.80 10 9 2.07 10 9 3.62 10 6 FM 0.68 0.48 0.23 0.12 0.09 0.05 being the same (0.15 Hz). The LF/HF n index is also very different: 0.03 for RR FM and 7 10 9 for RR p. An improved simulation includes the low-pass filtering effect reported by Womack (1971). We have computed the LF/HF n index for the outputs of several low-pass filters whose inputs were RR p and RR FM. The filters used were Butterworth fourth-order and bidirectional, with cutoff frequencies 0.05 Hz, 0.07 Hz, 0.10 Hz, 0.13 Hz, 0.15 Hz and 0.20 Hz. Table 1 shows the results. For the RR FM signal, the lower the cut-off frequency, the higher the LF/HF n index. For the RR p signal, the cut-off frequency strongly affects the LF/HF n index because of the small power in the LF band. In any case, the LF/HF n index is always smaller for periodic RR signals than for FM RR signals. Actual RR signals will be influenced by other heart rate variability factors in addition to the respiration. Therefore, in order to consider the spectral power in the LF band resulting only from the breathing pattern, we will high-pass filter the tachogram before performing spectral analysis. We have filtered the signals with a Butterworth fourth-order bidirectional high-pass filter with a cut-off frequency of 0.05 Hz. The results show that this filter has a negligible effect on the LF/HF n index for the simulated signals. 5. Experimental results We have recorded RR time series and breathing signals in 20 healthy subjects (30.9±5.1 years) in supine position. Measurements for each subject induced five stages with well defined conditions. Each stage lasted for 5 minutes and was followed by a 2 minute resting interval.

Breathing patterns influence HRV spectral bands 421 Figure 2. Measurement system. Before starting, subjects were in supine position for 5 minutes. In the first stage, subjects breathed at will. In the second stage, subjects were asked to breathe periodically at 0.15 Hz by following a signal on an oscilloscope screen. In the third stage, subjects were asked to breathe according to an oscilloscope displaying a 0.15 Hz signal modulated in frequency by 0.01 Hz with a 0.05 Hz frequency deviation. In the fourth stage, subjects returned to periodical breathing at 0.15 Hz, and during the fifth stage, subjects breathed at will again. Figure 2 shows the measurement setup. The isolated ECG amplifier (bandwidth 0.5 Hz to 500 Hz, gain 1000) recorded the standard II ECG lead. A nasal NTC thermistor yielded the breathing rhythm and amplitude. Since we were interested in the effects of breathing frequency, not amplitude, records whose amplitude were too different were discarded. ECG and breathing signals were sampled at 500 Hz in eight subjects and at 4 khz in twelve subjects by a plugin PC data-acquisition card (DT2821, Data Translation) and stored for further processing. RR time series were derived in two steps. The first step yielded an estimated location of each QRS complex by detecting when the ECG signal, low-pass filtered at 30 Hz and further differentiated, exceeded a threshold set at 75% of the maximal amplitude of the filtered signal. The second step corrected the estimated location by maximizing the correlation between the first QRS detected and the following ones. After properly detecting each QRS, the tachogram was computed by differentiating the position of each QRS. From the tachogram, a resampled RR time series was obtained with a sampling frequency of 4 Hz by interpolating with cubic splines. In order to remove low-frequency components present in the tachogram but unrelated to breathing patterns, the tachogram was high-pass filtered with a Butterworth fourth-order bidirectional filter with cut-off frequency at 0.05 Hz. Next, the periodogram was estimated for each subject and each stage, and the LF/HF n was computed. Figure 3 summarizes the results for the 20 subjects. Both sampling frequencies yielded the same results. The LF/HF n index is largest when breathing freely and smallest when Table 2. Significance of the differences between LF/HF n for the different breathing stages. If p<0.05, the difference is considered to be significant. Periodic 1 FM Periodic 2 Free 2 Free 1 0.0009 0.0254 0.0006 0.1926 Periodic 1 0.0014 0.3390 <0.0001 FM 0.0144 0.0003 Periodic 2 <0.0001

422 M A García-González et al Figure 3. LF/HF n index for the 20 subjects measured and the five stages (starting and finishing with breathing at will free ). Mean, standard deviation, fifth and 95th percentiles, and maximum and minimum are represented for each stage. breathing periodically. FM breathing yields an intermediate index value. Differences between stages were tested by a paired Student t-test whose results are shown in table 2. There are no significant differences between the two stages of free breathing, nor between the two stages of periodic breathing. There are significant differences between free and periodic breathing between free and FM breathing and between periodic and FM breathing. 6. Discussion The experimental results for periodic breathing show an LF/HF n index smaller than that for FM breathing, the same as for the simulated data in figure 1 (signal RR p ). Nevertheless, the LF/HF n index is larger for experimental than for simulated data. This is because the LF band of experimental data includes other modulations, such as those of the baroreceptor that are not completely rejected by the high-pass filter applied to the tachogram. It may also be due to drifts of the mean heart rhythm, to the non-sinusoidal waveform of the respiratory sinus arrhythmia and to changes in the transfer function between the breathing rhythm and the heart rate. FM breathing yields a large LF/HF n index as predicted from the theoretical analysis and from simulated data (RR FM ). Free breathing yields even larger values for the LF/HF n index than FM breathing, which is consistent with the large variability in breathing patterns when subjects are allowed to breathe at will. Therefore, interpreting changes in the LF/HF n index requires us to consider the breathing patterns simultaneous with the recorded RR series. 7. Conclusions The respiratory sinus arrhythmia reflects the relationship between the autonomic nervous system and the cardiovascular system, but it also reflects the breathing pattern. Any variation in this pattern influences the RR time series and modifies its power spectrum. Periodic breathing yields low values for the LF/HF n index. Breathing at will yields the larger LF/HF n values. Therefore, comparisons between the LF/HF n index for different subjects in HRV studies must consider the actual breathing pattern.

Breathing patterns influence HRV spectral bands 423 References Arai Y, Saul J P, Albrech P et al 1989 Modulation of cardiac autonomic activity during and immediately after exercise Am. J. Physiol. 256 H132 H141 Bigger J T, Fleiss J L, Rolnitzky L M, Steinman R C and Schneider W J 1991 Time course of recovery of heart period variability after myocardial infarction J. Am. Coll. Cardiol. 18 1643 9 Kleiger R E, Bosner M S, Rottman J N and Stein P K 1993 Time-domain measurements of heart rate variability J. Ambul. Monit. 6 1 18 Kollai M and Mizsei G 1990 Respiratory sinus arrhythmia is a limited measure of cardiac parasympathetic control in man J. Physiol. 424 329 42 Mateo J and Laguna P 2000 Improved heart rate variability signal analysis from the beat occurrence times according to the IPFM model IEEE Trans. Biomed. Eng. 47 Pagani M et al 1986 Power spectral analysis of heart rate and arterial pressure variabilities as a marker of sympathovagal interaction in man and conscious dog Circ. Res. 59 178 93 Pagani M, Malfatto G, Pierini S et al 1988 Spectral analysis of heart rate variability in the assessment of autonomic diabetic neuropathy Automedica 4 155 67 Peebles P Z 1976 Communication System Principles (Reading, MA: Addison-Wesley) Pomeranz B et al 1985 Assessment of autonomic function in humans by heart rate spectral analysis Am. J. Physiol. 248 H151 H153 Sands K E, Appel M L, Lilly L S, Schoen F J, Mudge G H and Cohen R J 1989 Power spectrum analysis of heart rate variability in human cardiac transplant recipients Circulation 79 76 82 Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology 1996 Heart rate variability, standards of measurement, physiological interpretation, and clinical use Eur. Heart J. 17 354 81 Wada T, Mizuno H, Ohba F and Kawashima H 1993 Nonlinear analysis of heart rate variability using bispectrum Annu. Int. Conf. IEEE Eng. Med. Biol. Soc. vol 15, pp 918 19 Womack B F 1971 The analysis of respiratory sinus arrhythmia using spectral analysis and digital filtering IEEE Trans. Biomed. Eng. 18 399 409