SAUDI COMMITTEE FOR PALESTINIAN RELEIF

Similar documents
Standard Specifications

Customer Connection Guide Updates Effective May 2017


Utility Structures. Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles

Section. DEVELOPMENT STANDARDS City of Ellensburg ILLUMINATION STANDARDS

SECTION PRECAST CONCRETE SECTIONAL MANHOLES

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-I) UNDERGROUND NETWORK GROUNDING. Rev. 01

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes

SECTION MANHOLES

SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEMS IN RESIDENTIAL SUBDIVISIONS. Notification of Completed Conduit Sections

A. Deviation from this standard must be approved by the Project Architect.

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 8

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING. Rev. 01

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

Page Electric Utility Service Specifications

SECTION UNDERGROUND POWER DUCT AND SUB-STRUCTURES. A. Section : Trenching, Backfilling, and Compacting

SCHEDULE OF WORK. Balmer Lawrie Co. Ltd. PRICED BID (PART-II) MMLH

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST

AL AQTAAR AL ARBAAH EST. COMPANY PROFILE. Panel Boards, Substation, Instrumentation, Automation.

MH Table of Contents Standard Title/Scope Page Table of Contents SCE Public

CONSTRUCTION SPECIFICATION FOR MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION

SECTION MANHOLES

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION

CONTINUING EDUC ATION

LOT 1: Provision and Installation of Electrical Networks for All Zones in Returnees Shelter Compound-Kilo 18- Ramadi- Anbar Governorate

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

CONTINUOUS COUNTERPOISE ON POLES

Manholes Table of Contents

METER - INSTALLATION Pad Mount Transformer

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

PART MATERIALS. Section Fencing Materials. Description

PORT OF ST. HELENS SCAPPOOSE INDUSTRIAL AIRPARK PARALLEL TAXIWAY B RELOCATON AIP PROJECT ADDENDUM NO. 1

SECTION 58 PRECAST CONCRETE BOX CULVERT. This work consists of furnishing and installing Pre-cast Concrete Box Culverts.

TECHNICAL SPECIFICATION OF ELECTRICAL MATERIALS CT & PT GROUP C

Low Voltage Products. Enclosed Third Harmonic Filter THF and THF star Enclosed units. Brochure THFS1GB 03_04 1SCC330003C0201

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS

MCset 17.5 kv. Installation instruction April Medium Voltage Distribution

CHAPTER-E-21. T1 Column With Beam Arrangement in Substation. T2 Column With Beam Arrangement in Substation

SECTION III STANDARD DRAWINGS ROYSE CITY GENERAL CONSTRUCTION NOTES & DETAILS

2' x 3' Polymer Pull Box Cover 4'-0" 7'-0" 24" x 76" Access Opening 3'-6"

Safety earthing. Sector Energy PTI NC. Copyright Siemens AG All rights reserved. Theodor Connor

POTENTIAL TRANSFORMER

MISTRAL SYSTEM IMPACT 2

Licensed Electricians Practical Assessment (LEP)

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts

StormTrap Guide Specification. StormTrap 2 SingleTrap on Aggregate Foundation Groundwater BELOW Invert Revised 11/30/17

Testing Manual for Electrical Equipment

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

Equipment Description Quantity as per drawings Actual quantity

NSP/004/107 (OHI 7) Guidance on the selection of conductor jumpers and non-tension connections

SECTION PRECAST CONCRETE STRUCTURES

APPENDIX FENCE GENERAL NOTES

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEM(S) FOR STREETLIGHTS. 1 Definitions. 2 Scope of Work. 3 Extent of Work

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD GROUNDING RESISTANCE MEASUREMENTS AND IMPROVEMENT

WBS 1100 Bill of Quantities

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

Electrical IP Red Seal Practice Exam

SECTION 5 TRANSFORMERS

International Tube & Conduit Company Ltd. BRITISH STANDARD STEEL CONDUITS & FITTINGS

SOUTH DUBLIN COUNTY COUNCIL Traffic Management Centre Roads (Traffic and Transportation) Department

Welcome to the Session on. HT Distribution Network

Appendix C Construction Details

SECTION CABLE TRAYS

Customer Requirements Commercial Secondary Service

MANUFACTURING GUIDELINES FOR PLC (LEVEL-1 AUTOMATION)

SECTION ELECTRICAL IDENTIFICATION

Section five. Connection systems. Isobar 4 Evo MCB pan assemblies Mulitclip busbar and Polybloc 126. Comb busbars 127

MPA Project No. M495-C1 Refrigerated Container Storage Improvements Project Location: Conley Terminal, Boston, MA

Ritz Instrument Transformers GmbH. Welcome

MULTIBLOC 00.ST8 Size A, 690VAC Bottom Fitting, 1-,2-,4-pole

REGATTA PATH LIGHT (RGP)

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

STRUCTURES FOR SANITARY AND STORM SEWERS

Licensed Electricians Practical Assessment (LEP)

SECTION III SUBMITTALS AND APPROVALS

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

STORM M ANHOLE FOR 42" PIPE AND SM ALLER JOB NO. SHEET NO. DATE MARCH 2015 OF MIN OF 3 CRSES MAX OF 5 CRSES 30"MAX 3 OR 3.5 PRECAST ECCENTIC CONC

Item 550 Chain Link Fence

50-SDMS-01 SPECIFICATIONS FOR

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. Hand or power. kpa/34.

STANDARD BID ITEM NUMBERS

ZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR

REVISIONS INDEX 2016 ROAD & BRIDGE STANDARDS

TABLE OF CONTENTS 7.0 CABLE INSTALLATION IN UNDERGROUND STRUCTURES

TRANSMITTAL LETTER. As Builts Change Order Contract Copy of Letter Insurance. For approval Approved as submitted Resubmit copies for approval

American Electrical Institute

Power Quality. Case Study. Conrad Bottu Laborelec January 2008

Premoulded cable joint SMPGB

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. The main is drilled out under pressure.

A. Product Description: Stranded conductor insulated wire.

SECTION PUBLIC UTILITY MANHOLES AND STRUCTURES. 2. Modular precast concrete pump wetwell. 5. Manhole bedding and cover materials.

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5

DATA SHEET. Switchboard instruments,

Transcription:

SAUDI COMMITTEE FOR PALESTINIAN RELEIF ITB 2014-042 PAL 10-49740 /Construction of 300 Residential Units in Rafah Package #12: Electrical and Telecommunication Works Part C. SECTION 9: PRICE SCHEDULE (Bill of Quantities) Electronic copy of the BOQ shall be submitted along with the signed hard copy thereof. In case of any discrepancy between the soft and the hard copies, the hard copy shall prevail.

Supplying, installing, testing and commission of the electrical works as per drawings, specifications, and engineer's instructions. The prices of the follwing items include all necessary junction boxes, wires, conduits, clamps, bolts, connectors and connecting all new and existing cables to switch,boards & Pillars. The price includes all measurement devices,equipments, machinary,..., ets. All installation shall be in accordance with : * The drawings, specifications, instructions and demands of the engineer and coordination with GEDCO. * The electricity law and electrical code requirments of the BRITISH standards. *The contractor should repair any damage of the existing infrastructures. *The Ressistance of any Earthing system must be less than 2 Ω, and the contractor must find and do the solution to be < 2 Ω. Unit Quantity 1.1 Supply, Install, Connect,and Test 36 kv Switch Disconnector (Isolating Switch) on the existing pole with builtin arc interrupter, Master key lock, Compression Lugs with all needed Arms on the two existing poles to complet the work, six complete tension units (with its all Tension Glass Disks, Half Moons and all needed for Fixing & Connection ), heatshrinc termination kits,wires for earthing,all needed clamps, and all acessories for Fixing & Installation. The price include all M.V ACSR wires to connect the new network to the closer existing network (between two poles). All works must be According to supervisor Instructions and Approval of GEDCO. L.S. 1 1.2 Supply, Instal, Connect, and Test 24 kv, 630A Switchgear, and 16 ka Short Circuit Current Ring Main Unit SF6, 2 incoming switch Disconnectors, one Transformer Protection fuse switch combination (CTC) With 22 kv Porcelain Fuses 63 A. The price include connecting the existing cables to CTC. The Work Include wires, Clamps,70mm2 wires for earthing,shielded Fore Connectors with Cable Adapter & Jacket Seal for all in/out cables & all needed acessories. All works and materials must be According to supervisor Instructions and Approval of GEDCO. Unit 2

1.3 Supply, Instal, Connect,and Test 22/0.4 KV Low Losses, 3 phase, Indoor Distribution Transformer 1250 KVA Rating Type :3 phase oilimmersed Hermetically Sealed. Reference Manufacturing: IEC 60076 or DIN42500 Standards. Complete with all needed Bushings and Arms for Fixing the Cable beside the Transformer with cable ladder. The Work Includes connecting the existing cables and all needed new cables to connect CTC with Transformer and Transformer with LVDB, all needed Lugs, Clamps,70mm2 Wires for Earthing system for transformer. The item include supplying & fixing Fire Extinguisher, Emergency lighting & all needed steel wire mesh protection to isolate the Transformer. All works and materials must be According to supervisor Instructions and Approval of GEDCO. Unit Quantity 2 1.4 Supply, Instal, Connect,and Test L.V Distribution Board 2000A (bus bars system ) with Main CB IZM 2000A (7 Feeder). Bus Bars,6 Vertical LTL 630/400A & 1Vertical LTL 160/100A (Jean Moeller Type or equivalent ), Current and Voltage Instruments With CTs, LTL3*32/6A, MCB 3*32A, wires, Clamps,70mm2 wires for earthing, all needed acessories & all components in the drawings. The price include connecting all the existing & newer feeder cables to the board. The size and specifications of board & all works and materials must be According to the drawing, supervisor instructions, specifications and approval of GEDCO. 2 1.5 Supply, Instal, Connect,and Test 630A M.LV Pillar (bus bars system ) with main Vertical LTL (630/400 A), 3 Vertical LTL (250/160A),(Jean Moeller Type), Bus bars for phases + N + E, 4 Inch sleeves and all needed wires, accessories and PVC Terminals connections. The price include all needed civil structure according the drawing, specifications of GEDCO, supervisor instruction, and comply with the existing Pillars. The price include earthing system ( manholes, electrodes,35mm2 wires, treatment of the soil, all accessories and all needed to be the Ressistance less than 2 Ω ) The work include connecting all the in/out feeder cables to the Pillar. All works and materials must be According to the drawing, supervisor instructions, specification and approved of GEDCO. Unit 2

1.6 Supply, Instal, Connect,and Test 250A LV Pillar (bus bars system ) with main Vertical LTL (250/160 A), 6 Vertical LTL (160/63A), (Jean Moeller Type), Bus bars for phases + N + E, 4 Inch sleeves and all needed wires, accessories and PVC Terminals connections. The price include all needed civil structure according the drawing, specifications of GEDCO, supervisor instruction, and comply with the existing Pillars. The price include earthing system ( manholes, electrodes,35mm2 wires, treatment of the soil,all accessories and all needed to be the Ressistance less than 2 Ω ) The work include connecting all the in/out feeder cables to the Pillar. All works and materials must be According to the drawing, supervisor instructions, specification and approved of GEDCO. Unit Quantity Unit 6 1.7 Supply, Install Connect and Test external lighting HEIMEL Control Panel box, as the following: The panel must be made of water proof fiberglass, (80*60*25 cm) size, including : LTL 3*160/100A, 3ph KWHM, NZM1 3*80A, 3A Kaga photocell,(no. 3) Moller Contactors DIL/M65 30KW, PSK Timer, over/under voltage relay protect,triple switches, MCB's, wires, busbars, all according to the drawings & all needed connectors and accessories. The item include supplying & installing all needed cable XLPE 3*25+16 between LVDB and lighting panel, Cables Guards to protect the cables, and Cable Holders to fix the cables. All works must be According to drawing and supervisor Instructions. Unit 2 1.8 Supply, Install Connect and Test 0.6/1KV, L.V Cable 3*150+75 mm 2 CU, XLPE. The work include the following : Excavation of the cable trenches in any soil with dim. ( 50 cm width & 110 cm depth ). Supply & lay UPVC pipes (SN8 6") at cross road trenches. Supply & backfill by clean sand around the cables,as drawings. Supply & fixed 45x45x5cm concrete slabs with flexural strength (5 Mpa), along the trenches including the warning tape after Backfill clean Sand 10 cm Thickness.All needed to complete the work The work includes watering & compaction to 100% of MDD each layer with 25cm depth as per drawings & supervisor instructions. All works must be According to drawings and supervisor Instructions. L.m. 120 1.9 Ditto but 3*50+25 mm2 CU, XLPE. L.m. 300

Unit Quantity 1.10 Supply, Instal, Connect,and Test L.V Cable 4*16 mm 2 Cu., L.m. 2000 XLPE. The work include the following : Excavation of the cable trenches in any soil with dim. ( 40 cm width & 90 cm depth ). Supply & lay spring pipe 3" at the trench. Supply & backfill by clean sand around the pipes, first layers with 50 cm depth. then warning tape and after Backfill clean Sand with 40 cm thickness. The work include all needed to connect the dwelling units M.D.Bs with electricity. All work must be according the drawings and Engineer approval. 1.11 Ditto but 4*25 mm2 CU, XLPE. L.m. 90 1.12 Supply and Install concrete base for future installation of 35 1.13 Hot galvanized octagonal street light pole 8m long including bsupply l and l Install d 3" lspring b pipe d layed at 80cm fdeep das L.m. 1000 following (pipe then 30cm soft sand then warning tape then 50cm sand). As per drawings and Engineer instruction. 1.14 Ditto but UPVC 6'' SN8 for future XLPE 3*150+70mm cable at depth 110 cm L.m. 40 1.15 Supply and Install Octagonal lighting Pole 8m, the work include supplying and installing the following : Single Arm, with 105 degree angle. 150W M.H Luminaire,chock coil, condenser, ballast ( Type : Philips Malaga SGS102/SON T150W ). 3*2.5mmsq cable inside 1 Inch flexible conduit for Luminaire. control box with 1x10 A m.c.b. All needed Bolts,Nuts,Washers,Terminal connections, Accessories, & all needed rinforced cement. All works must be According to drawing and supervisor Instructions Unit 75 1.16 Supply, Instal, Connect,and Test N2XY Cu cable 5*10mm 2. The work include the following : Laying the cables inside the existing or new spring pipes. Repairing any damages in the existing spring pipes as required. All works must be According to the drawing and supervisor instructions. L.m. 2100

1.17 Supply and install 60 cm internal diameter precast circular reinforced concrete manhole for St. Light Earthing System, with iron cover with frame 8 ton capacity. The work includes excavation in any type of soil to any depth, backfilling with clean sand and compaction 98% MDD up to the design leveling of the roads. The item inclue all needed (4 Parallel, 18mm,3m Cu electrodes) with 3m minimum distance,cu stranded wire 35mm2 in 2'' flixable pipe to connect between the electrodes and pole, clamps,chemical treatment of the soil, all accessories to be the Ressistance less than 2 Ω. The Manhole above one electrode only. All works must be According to the drawings and supervisor instructions. Unit Quantity Unit 15 1.18 Supply and install 35*3mm hot galvanized steel strip to connect between all existing and new earting manhols of Electrical Pillars with the proposed earthing system. The work includes excavation up to 100 cm depth, backfilling with clean sand and compaction 98% MDD up to the design leveling of the roads.the work includes all needed clamps, 70mm wires, accessories,..., etc. The price includes suppy and install 60 cm internal diameter precast manhole, with iron cover with frame 8 ton capacity. The work includes excavation and backfilling, also all needed Cu electrodes, wires 35mm2, clamps. The number of manhols and electrodes is according to be the Resistance of earthing system less than 2 Ω. All works must be According to the drawings and supervisor instructions. L.S. 1 1.19 Supply and install 60 cm internal diameter precast circular reinforced concrete manhole, with iron cover with frame 8 ton capacity. The work includes excavation in any type of soil to any depth, backfilling with clean sand and compaction 98% MDD up to the design leveling of the roads. Unit 4

Bill No (2) Comunication Works Unit Quantity Communication Works 1.The contractor has to submit detailed shop drawings of the coming items for the approval by the PalTel Company before starting the work. 2. The Contractor has to visit the site for inspection. 3.The price includes the cost of excavation to depth indicated in drawings and using retaining shuttering, shoring according to the instructions of Engineer, bedding of 15 cm clean sand under,around and above the pipe with compaction, backfilling of the trench up to design level in layers 25cm thick for each with compaction 98% MDD and all required tests. 4.The work includes connection of the manholes to the existing PalTel line after cleaning and adjusting the level and orientation of the existing pipes if needed according to engineer instructions. 5.The holes of the manholes have to be done using core machine. 6.The price includes reinstate repairing any damage resulted from the work, all according to specification & as per engineer instructions 2.1 Supply, install and join single line of flexible PVC pipes 3" diameter for the PalTel house connection including excavation in any ground for min. 1.5m depth, shoring, shuttering, safety measures, testing, sand beds, opining in the existing manholes and concrete around PVC pipes all according to the drawings, specifications and Engineer s 50 2.2 Supply, install and join single line of PVC pipes 4" diameter V1. for the PalTel network with approved gasket rubber ring including excavation in any ground for min. 1.5m depth, shoring, shuttering, safety measures, testing, sand beds all L.M 25 according to the drawings, specifications and Engineer s instruction. 2.3 Ditto but double lines of PVC pipes 4" V2 L.M 25

OVERALL SUMMARY DESCRIPTION $ Bill 1 Bill 2 ELECTRICAL WORKS TELCOMUNICATION WORKS Sub $ Deduction Ratio Grand After Deduction in numbers... in letters... Name of the contractor...... Authorized signature...... Signature and Sealing. Title... Telephone. Fax. Mobile.