INVISIBLE 6 P/L ASSEMBLY AND OPERATING INSTRUCTIONS USA & CANADA
General Instructions Vitra products are manufactured according to the latest technology and comply with alid rules and regulations. Neertheless, these products can cause injury or damage if: the product is improperly installed the product is improperly used the product is improperly altered or modified original accessories are not used the safety regulations are not obsered. WARNING Each person inoled in the planning, installation and/or use of our products must be carefully read and obsere these instructions of use. The following are of course also alid: Releant accident preention regulations Generally recognized safety rules National regulations please consult Vitra if there is a discrepancy with the Assembly manual Safety instructions WARNING When playing, children often incorrectly assess danger. You must therefore make sure that your store fittings are not used as toys. Please pay attention to the following points: Structural conditions, in particular the design and bearing capacity of walls, ceilings and floors. If bearing capacity for the specified tractie or pressure load cannot be achieed by suitable fastening or stabilising elements, please refrain from installation. All the structural components supplied for stabilising structures are to be used in an unrestricted manner and must not be remoed. The products may only be loaded after all the installation steps hae been completed. Merchandise supports should be loaded as eenly as possible. Aoid loading in fits and starts. The maximum weight loads is to be obsered. This can be found in the instructions on assembly and use, as well as in our sales documentation. Furniture with castors is generally much more unstable than furniture with glides. Tall, heay structures on castors should thus be aoided. The recommendations of your safety officer should also be obsered. General care for chrome, silk and pearl In clothing retail applications, frequent dragging of clothes hangers along the surface can cause slight abrasion to their hooks. This effect is most pronounced - more so than with front-on horizontal or inclined-pole displays - where garments are hung side-on such that hangers hae to be moed more frequently. To preent garments from becoming soiled, cleaning of the hanging rods is essential. This abrasion can be considerably reduced by using a coat hanger coer (scliss, 929-449.2). No responsiblity can be accepted for damage caused by soiling, as the aboe mentioned abrasion depends on the material of the coathangers in use. With powder-coated surfaces subject to frequent use, use of special paints is recommended. We will be happy to adise you. Use and care of merchandise supports with anodised aluminium surfaces Vitra merchandise supports with anodised aluminium surfaces are hard-wearing. Howeer, the exchange of accessories might cause slight marks on the surface. Accessories with plastic inserts usually cause less wear or none at all. To remoe the marks, we recommend using cleaning agents ranging from ph 5 8 (do not use any detergents with acidic or alkaline reaction). Clean by washing the surfaces using a sponge and water containing a wetting agent. Then remoe any loose or greasy dirt. Rubbing off the surfaces with detergent using pure cotton waste or porous cleaning tissue and applying the necessary pressure in rubbing direction will remoe the marks. Aluminium profiles with widths exceeding 2 mm/ 7.874" must be subjected to abrasie cleaning using detergents specifically deeloped for this purpose. The cleaning agents deeloped for abrasie cleaning contain ery finely ground neutral polishing agents and hae to be adapted to the oxide layer. Alternatiely, cleaning can be carried out using an abrasie fibrous web (e.g. Scotch-Brite, type A, red, fine or ery fine) in combination with a non-abrasie detergent. Subsequently, residual cleaning agents should to be rinsed off using a sponge and clear water. Then rub off the part with a chamois. Copyright This manual is protected by copyright. Its use is permissible as part of the use of the product. Any use other than this is not permitted without written consent of the manufacturer. Our General Terms and Conditions apply for all orders. Dimensions are generally shown in millimeters and inches. www.itra.com retail@itra.com 2 1/218 (US)
Inisible 6 P/L Technical data sheet inisible 6 P/L Inisible 6 P/L has a CE label and a UL certificate for U.S. and Canada. Conerter 24 V for electrified profile Conerter with input oltage 12 24 V / mains frequency: 5 6 Hz electronic protection against oerload, oerheating and short-circuit. - Housing temperature max. 75 C / max. 167 F - Nominal output oltage: 24 V / SELV - Power supply with permissible nominal current of max. 4 A - Connection cable from conerter to infeed unit 5 mm/19.685" - Class 2 NOTICE! If dimmers are to be used, electronically controlled, low-oltage dimmers must be installed! 349-119.19 (96 W) ø 7.7 mm.33" NV (24 V) L = 5 mm / 19.685" 12 V L = 2 mm / 78.74" Please make sure that the inspector has access to the drier. We recommend to sole this with Inisible Change. Single power adapter 24 V Single power adapters can only be used with the Inisible 6 P/L system. Low oltage lighting and low oltage appliances may only be connected by trained personnel. If multiple adapters and appliances will be used, their total power consumption may not exceed the specified nominal current or fuse rating. The permissible nominal oltage and nominal acurrent are also limited according to the adapters used (see printed label and safety information). Permissible nominal current max. 4 A 225-945.19 225-946.19 Inisible 6 P/L rail capacity Profile length L = 324 mm/119" Max. amount of sheles with lighting, size 62 x 42 mm/24.49"x 16.535" 4 sheles Product safety Inisible 6 P/L electrification in detail: conductor rail with power supply, integrated into system support profile. Correct functioning and safety are guaranteed when properly used. No liability is accepted in eent of improper use. Product safety is based exclusiely on the use of original Inisible 6 P/L accessories from Vitra. No alterations may be made, for safety reasons; the only exception is the shortening of profiles from the right-hand side. The safety instructions of the assembly instructions must be followed as well as the instructions on the labels of the indiidual parts. The indicated nominal current (A) may not be exceeded. The number of sheles with lighting that are connected to the conductor rails also may not exceed the capacities indicated in the table. In eent of improper use or cleaning with liquids, a risk of an electric shock exists due to possibly exposed lie parts. Always disconnect from power before cleaning or sericing. If rails or adapters exhibit isible signs of damage, disconnect them immediately and inform your serice technician. Only use Inisible 6 P/L system accessories! Do not use any other parts. The user is responsible for ensuring that any connected equipment is electrically, mechanically and thermally compatible with the conductor rail. 3
Inisible 6 P/L Vitra connection system Check the power consumption of electrical appliances! The maximum power consumption should be 1% below the nominal power of the conerter. Powering with 96 W conerter 1 2 2 3 4 4 1 2 3 4 1 Power supply 24 V left 2 Power supply 24 V right, incl. isolation 3 24 V distributor, 6 way - optional 4 96 W LED conerter Dimensions of the 96 W conerter 394 15.512" 364 14.331" 5 1.969" 87 3.425" NV (24 V) L = 5 mm / 19.685" 364 14.331" 12 V L = 2 mm / 78.74" 55 2.165" 4
Inisible 6 P/L Assembly dimensions / layout The fastening material and the wall must be capable of supporting a min. tensile force of 396.8 lbs per fastening point. Please obsere the indications concerning weight loads and ensure that the substructure of the wall units/furniture and their fixtures can support the expected loads. With free-standing furniture, ensure that there is sufficient stability een with the intended merchandise supports. Important information on electrified Inisible 6 P/L can be found in Technical data sheet Inisible 6 P/L. 34.5 1.358" 72 2.835" 1.4.49" 3 1.181" Dimensions profile electrified All fastening points hae to be used in eent of maximum loads! End caps must be fitted on profile with conductor rail. L = 324 mm/119.55" lto: min. 75 max. 324 mm/ min. 27.756" max. 119.55" L = Total length (with infeed and end cap) ± 1/±.39" L - 24 = Length of profile ± 1 /±.39" 22.866" 28 1.12" ø 7.5.295" 156.25 6.152" 156.25 6.152" 156.25 6.152" 2.79" 72 2.835 optional Depending to your local regulations, a conduit must be used for the primary side of the drier. Dimensions - profile without electrical power All fastening points hae to be used in eent of maximum loads! L = 324 mm/119.55" lto: min. 75 max. 324 mm/ min. 27.756" max. 119.55" L = Length of profile ± 1 / ±.39" 5 1.969" ø 7.5.295" 156.25 6.152" 156.25 6.152" 156.25 6.152" 72 2.835" optional 5
Inisible 6 P/L Mounting to a substructure ca. 6 x 3 x 2.5 approx. 2.362"x 1.181"x.98" 7.276" 4.157" 5.197" 4.5.177" 1.1.398" 21.5.846" 1.4.49" 3.5 1.21" 4.5.177" 1.1.398" 18.79" 14.5.571" 16.63" 16.63" 11.433" 6 2.362" 3.5 1.21" 47.5 1.87" 23.75.935" 36 1.417" 3 1.181" 6.236" 22.866" 14.551" Mounting to a panel from the rear R 15.25.6" R 5.2.25" 14.551" 5.2.25" 22.866" Length of profile Length of profile + power supply +1 +.39" 5.2.25" 23.75.935" Fastening examples Obsere the indications concerning assembly on different surfaces. A A min. 7 min. 2.756" min. 25 min. 1" A A Solid wood edge strips (A) must be glued and screwed to the panel. A Assembly on different surfaces Depending on the type of wall the profil can be attached with different fixation material. The max. weight load of the profile depends on the nature of the wall, on the number of fixation points as well as on the fixation material used. With wooden substructures, a screw length of min. 5 mm must be obsered. Please obsere the instructions supplied by the dowel manufacturer. min. 5 Wood Metal (square tube) Porous material Concrete 6
Inisible 6 P/L Shortening a profile Total length 324/119.5 The electrical components and the end cap must be remoed before shortening the profile. Always shorten a profile from the right-hand side and burr the edges. Make sure that all shaings are remoed from the profile. The electrical components and end cap must be fitted back onto the profile. 22.866 L L - 24 L -.945 X 2.79 Maximum loads Optimal distance between the uprights: 312.5 mm/12.33" 312.5 12.33 312.5 12.33 ok! 2 28 1.12 312.5 12.33 312.5 12.33 28 1.12 ok! Fastening points The system s functionality can only be guaranteed if the profile lies completely flat against the aligned substructure surface! > Use pan-head screws! Merchandise support slightly inclined upwards (2 ). Profile assembly Increased carrying capacity (up to 2%) can be achieed by securing the Inisible profile to the panels by applying a suitable adhesie. Mount the power supply unit on the left-hand side of the wall. It must be ensured that access to the drier is possible for inspection and subsequent sericing. Leae a gap between the conerter housing and panel. 2.787 16.63 7
Inisible 6 P/L Instructions for use Insert the non electrified Inisible support bracket or shelf into the profile at a slight angle until the limit stop is reached. Then lower the support or shelf. Make sure that the Inisible merchandise support or shelf has correctly clicked into place. Inisible 6 P/L profile for attachment from the front, for walls Dimensions of holes All fixation points are to be used with maximum loads. 31 mm/122" lto = min. 25 max. 31 mm/min.1" max. 122" 25.984" 1 3.937" 1 3.937" ø 5.3.29" (75) (2.953") 34 1.339" 8.5.335" 65 2.559" Assembly 1. Screw the end caps to the profile with the screws proided. 2. Drill holes into the wall at 1 mm/3.937" interals (note: to select the right fixtures, see below Front assembly on different surfaces ). Screw the profile to the wall. 3. Fit the profile coer. 1 2 3 1 mm 3.937" Assembly on different surfaces The Inisible 6 P/L profile for attachment from the front can be mounted on different wall types. The max. weight load of the Inisible 6 P/L profile depends on the nature of the wall, on the number of fixation points as well as on the fixation material used. With wooden substructures, a screw length of min. 5 mm/1.969" must be obsered. Please obsere the instructions supplied by the dowel manufacturer. For mounting on plaster, the following dowels are recommended (manufacturer Hilti): Hollow toggle plug HTB-S M5x6 Hollow plug HHD-S M5/12x52 Gypsum min. 5 1.969 Wood Metal (square tube) Porous material Concrete 8
Inisible 6 P/L Inisible 6 holder Assembly dimensions The arrangement of the holders must be adapted to the respectie assortment and expected load. 6 2.362" R5.197" 34 1.339" 15 19.591".748" Wood 19 mm/.748 5 +.2 1.969" +.8" 44 +.2 1.732" +.8" ø 2 x 8.79"x.315" 9 3.543" 6 2.362" 3 1.181" 17.669" 65 +.2 2.559" +.8" R5 +.2.197 +.8" 15 +.2.591" +.8" +.2 17 16.5.669" +.8".65" Assembly Inisible 6 P/L holder The Inisible holder is screwed on from the back with 6 screws. Ensure that the rabbet size and a material thickness of 19 mm are respected as otherwise the coer cap set cannot be correctly fitted 19.748" 3.118" 16.63" 16.63" Spacers are only needed when holders are fixed in combination with the profile into a 16 mm wooden panel. Reduced load-carrying capacity with 16 mm clamping plate! Spacer 929-192.6 3.118" Examples of fixation 19.748" 18.79" 16.63" Spacer 929-192.6 9
Inisible 6 P/L Change by Inisible 6 P/L Dimensions of the substructure It is possible to shorten the profile by a grid pitch of 2 mm - max. 8 mm. 2795 11.39" 265 14.331" 255 1.394" 23 9.551" 22 86.614" 21 82.677" 195 76.772" 185 72.835" 17 66.929" 16 62.992" 135 53.15" 125 49.213" 115 45.276" 9 35.433" 65 25.591" 55 21.654" 4 15.748" 2 7.874" 2 7.874" 2 7.874" 55 21.654" 2 7.874" 2 7.874" 5.2.25" 539.6 21.244" 32 1.26" 8 31.496" 75.2 2.961" 15 6.591" 2.362" 24.5.965" 1
Inisible 6 P/L Alignment and installation of the substructure 312.5 12.33" 312.5 12.33" 1 2 Attaching the panels Click! 312.5 12.33" Click! Click! Production drawings of the panel is aailable for downloading on www.itra.com or can be receied on request. Drawing no. 365-32 11
Inisible 6 P/L Side coer set 1 77 3.32" (83) (3.268") 44 1.732" 3.118" Wooden shelf dimensions for LED lighting fixture with cable connection - length 2 62 mm / 7.874" 24.49" - depth 1 343 mm / 3.937" 13.54" - thickness 25 45 mm /.984" 1.772" 321-729.31 225-946.19 349-118.12 Production drawings of wooden sheles are aailable for downloading on www.itra.com or can be receied on request. Drawing no. 247-148 22.835" (58 mm) 332-42.5/.6 3 K (6W) 332-436.5/.6 4 K (6W) Wooden shelf with lighting set: Distance to back panel Assembly option 1 Assembly option 2 34 1.339" Countersunk screw M5 x 2/.787" 3.5.138" 12.472" Countersunk screw M5 x 2/.787" 12
Inisible 6 P/L Wooden shelf without electrification 321-729.31 Production drawings of wooden sheles are aailable for downloading on www.itra.com or can be receied on request. Drawing no. 286-517 Wooden shelf dimension for bracket concealed 987-348.31 and bracket for side hanging rail 987-881.1/.3 Distance to back panel 987-348.31 34 1.339" 987-881.1/.3/.7 (3.5) (.138") Production drawings of wooden sheles are aailable for downloading on www.itra.com or can be receied on request. Drawing no. 286-517 Glass sheles (safety glass) 6 mm with cutouts to be inserted into the profile. The cutouts make it possible to insert further stepped brackets (987-881.1/3) for side hanging rail. Production drawings of glass sheles are aailable for downloading on www.itra.com or can be receied on request. Drawing no. 374-263 Locking deice for shelf elements The locking deice is used to secure the locks of the shelf elements inside the profile. It can be used for glass, aluminum (Fig. A) and wood shelf elements (Fig. B). A set of locking deices (left and right) is included in the scope of deliery for glass and aluminum shelf elements. If the customer produces a wood or glass shelf element, by himself, the locking deice must be ordered separately. These locking deices are a compulsory requirement and must be used for all shelf elements! Merchandise support slightly inclined upward (2 ). A B 13
Inisible 6 P/L Careful handling with merchandise support for Inisible 6 P/L 1. Lift the merchandise support slightly and insert it into the profile at a 9 angle until you reach limit stop A. 2. Release the merchandise support and check that it is correctly secured. Do not try to force it to the left or right. 9 A Single power adapter for Inisible 6 P/L 1. Insert power adapter into profile at a 9 angle until limit stop is reached. 2. Lock adapter in place by pressing the catches at the side. Shelf with lighting for Inisible 6 P/L In order to aoid any damage to the contact on the electrical adapters, it is important that the shelf is slightly inclined downwards when inserted into the electrical profile. max. 2 kg Inisible 6 P/L profile When attaching supports or sheles, please obsere a min. distance of 4 mm/1.575" to the power adapter (left-hand side of profile). Warning: Only use the conductor rail for sheles with lighting and for low oltage appliances up to 13 watts (24 V). min. 4/1.575" min. 4/1.575" Inserting electrified glass or aluminum shelf elements Proceed as follows to insert electrified glass or aluminum shelf elements: 1. Insert the locking deices (2) into the profile. 2. Introduce shelf element (1) into the profile, tilt it slightly downwards, with the two contact springs upwards, until to the stop. 3. Ensure that the shelf element is correctly engaged in the profile (B). 2 A 1 B 14
Inisible 6 P/L Fixing set for Inisible 6 P/L profiles To be screwed to the back of wooden panels. Cannot be used in Inisible 6 P/L holder set 28 1.12 Weight loads The indicated weight loads are always based on the total weights of the merchandise support and goods. Please note that max. permissible load decreases as the merchandise support increases in length. Please note that the inclination of the merchandise support changes with an increase in load. Different weights on the merchandise supports result in an uneen oerall appearance of the goods display. Please note that the weight limit can be reduced considerably when mounting in glass and sheet metal. The max. permissible load of the Inisible 6 P/L depends on the nature of the wall, the number of fastening points as well as the fastening material used. All fastening points hae to be used in eent of a maximum weight load. Please also obsere the weight loads indicated in our sales documentation. Max. load Profile per 625 mm/24" 88 lbs Holder set per holder 44 lbs Front arm Ø 25 mm/1" 55 lbs Front arm 3 x 15 mm/1 3 16" x 5 8" 55 lbs Front arm Ø 12 mm/½" 22 lbs Front arm 4 mm/ 5 32" 22 lbs Hook Ø 7.5 mm/ 9 32" 4.4 lbs Side hanging rail T arm Ø 25 mm x 6 mm/1" x 24" for use in Inisible 6 P/L holder set 44 lbs Side hanging rail T arm Ø 15 x 39 mm/ 5 8" x 15 3 8" for use in Inisible 6 P/L holder set 22 lbs Side hanging rail T arm 3 x 15 mm, 6 mm/1 3 16" x 5 8", 24" for use in Inisible 6 P/L holder set 44 lbs Side hanging rail T arm 2 x 1 mm, 39 mm/ 3 4" x 3 8", 15 3 8" for use in Inisible 6 P/L holder set 22 lbs T-bracket for wooden or glass shelf for use in Inisible 6 P/L holder set 44 lbs Bracket for side hanging rail Ø 25 mm/1 per bracket 44 lbs Bracket for side hanging rail Ø 15 mm/ 5 8" per bracket 22 lbs Bracket for side hanging rail 3 x 15 mm/1 3 16" x 5 8" per bracket 44 lbs Bracket for side hanging rail 2 x 1 mm/ 3 4" x 3 8" per bracket 22 lbs Bracket for wooden shelf per bracket 44 lbs Bracket for glass shelf per bracket 44 lbs Bracket 4 mm/ 5 32" for wooden shelf per bracket 22 lbs Bracket Ø 15 mm/ 5 8" for wooden shelf per bracket 33 lbs Angled shelf 33 lbs Hook rail for ties, belts etc. 22 lbs Uniersal bracket 44 lbs Fixing set for Inisible 6 P/L profile 44 lbs Tempered glass shelf 6 mm with cutouts (374-263) 33 lbs Tempered glass shelf 6 mm (286-617) 44 lbs 15
www.itra.com retail@itra.com