Page 1 of IR Port 5 External power port 6 Calibration button port 7 DUT + jack 8 DUT - jack 9 Shielding grounding jack

Similar documents
LCR METER OPERATION MANUAL. Model : LCR Hz 120 Hz 1 KHz 10 KHz 100 KHz, Precision

LCR METER Model:

LCR METER Model:

AMM-3035 User s Manual

Models 885 & 886 LCR METER OPERATING MANUAL

AMМ-3320 Multi-function LCR USER`S MANUAL

U1730C Series Handheld LCR Meters

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL

Elma 6400 LCR Meter. English 31 EAN: riešenia na presné meranie

Passive Component LCR Meter

OPERATION MANUAL. Multi-Function LCR LIST OF PRODUCTS MODEL KM 520B

Passive Component LCR Meter

Analog Technologies. Multimeter DM4070

Passive Component LCR Meter

Model: &

M328 version ESR inductance capacitance meter multifunctional tester DIY

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

Bench LCR Meter Model 891

DIGITAL MULTIMETER AX-588B

Agilent U1731C, U1732C, and U1733C Handheld LCR Meter

Frequency up to 100 khz

SMART TWEEZERS Model ST-1 User s Manual Version 1.0

Benchtop LCR Meter. Model Tenma Test Equipment 405 S. Pioneer Blvd. Springboro, OH

MEASURING INSTRUMENT. Capacitance Leakage Current / IR Meter Model IR Features.

Pocket Size Digital Multimeter Models: and

Mini Clamp Meter Model:

AC/DC CLAMP METER USER S MANUAL

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

R/C SMD Tweezers Multimeter Model RC200

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

2000 A DCA/ACA CLAMP + DMM,

Multifunction Digital

Digital Multimeter AX-572. Instruction manual

MS2109A AC/DC Clamp Meter. User Manual. Contents

BENCH METER Model>9803. Wavecom Instruments

MT 4080 LCR METER OPERATING MANUAL

Digital Clamp Meter Model: &

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

Contents. Ⅰ. General. Ⅱ. Open-package Inspection. Ⅲ. Safety Note. Warning:

MULTIMETRE DIGITAL 3 3/4 AVEC ECHELLE AUTOMATIQUE & EXTINCTION AUTOMATIQUE MANUEL D UTILISATION

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

DVM1190 DIGITAL MULTIMETER

500 khz / 1 MHz Precision LCR Meter Models 894 & 895

Digital Multimeter, Pen Type

LCFesR 4.5 precise, wide range measuring unit

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

OPERATOR S INSTRUCTION MANUAL

Agilent U1730C Series Handheld LCR Meters

NOTE: Fully read and understand this manual before using this Digital Multimeter.

CONTENTS MS2033A. 1.Introduction Safety Information...01

The Keysight Technologies, Inc. U1730C Series handheld LCR meters allow you to measure at frequencies as high as 100 khz a capability typically found

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

Keysight Technologies U1730C Series Handheld LCR Meters Take your expectations higher with the latest LCR meters. Data Sheet

UT207A/208A/209A Operating Manual. Table of Contents

APPA 300 Series. The Most User-Friendly High Performance Multimeter

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL

Pocket Size Digital Multimeter with USB Model: A & A

Grundlagen der Impedanzmessung

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

500 khz / 1 MHz Precision LCR Meter Models 894 & 895

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Testing & Calibration Lab, 204, Diamond Industrial Estate No. 2, Ketki Pada Road, (Near Dahisar Toll Naka), Dahisar (East), Mumbai, Maharashtra

DM-46 Instruction Manual

4.5 Auto Power Off During use Preparation For Measurement Symbols...3

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

True RMS. AUTO RANGE MULTIMETER CAT III-1000 V category, Auto range, REL, Capacitance Hz, Duty, ACV, ACA, DCV, DCA, Ohms

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

770E DIGITAL MULTIMETER OPERATOR S MANUAL

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

S-11 S-11. Digital Multimeter Operating Instruction. Digital Multimeter Operating Instruction

Handy LCZ Chips Smart Tweezer latest/improved Model ST5S

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

Dawson DDM190. Digital Multimeter User s Manual

Table of Contents. Table of Contents Instrumentation Multimeter. Lucas Nülle GmbH Page 1/14

OPERATOR S INSTRUCTION MANUAL

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

AC750 DIGITAL CLAMP METER

Instruction Manual for Digital Grounding Resistance Meter

USER'S MANUAL DMR-6700

ATK Clamp Meter

AX-C Introduction. 2. Safety Information

The Meter Structure The Figure 2-1 shows the Meter structure.

400Amp True RMS AC/DC Clamp Meter Model EX613

Item ref: UK MTM01 DIGITAL MULTITESTER. User Manual

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

QUICK REFERENCE OVERVIEW. Display Area

Not for Reproduction

DM-46 Instruction Manual

DB230 Capacitor Tester

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

SAFETY PRECAUTIONS: Before use, read the following safety precautions

Digital automotive analyser 13 function with ic

DDM350 Pen-Type Digital Multimeter User s Manual

Current clamps for AC current

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

Transcription:

1. General instructions: Thank you for purchasing a MS5308 LCR digital bridge meter. The MS5308 LCR digital bridge meter is a professional instrument for measuring inductance, capacitance and resistance. It has many features, such as automatic identification, automatic measurement range, high measurement accuracy and speed, wide measuring range and so on. An ordinary multimeter only provides DC mode for resistance measurement, while the MS5308 provides both AC and DC measurement modes. A variety of test frequencies up to 100Khz can be provided for inductance, capacitance and resistance in AC mode to meet the actual needs better. Correct usage can ensure that the instrument will work precisely for a long time. Please read the instructions carefully before using and operate the instrument strictly in accordance with the instructions. 1.1. Panel description 1 Display 2 Functional buttons area 3 Power switch 4 IR Port 5 External power port 6 Calibration button port 7 DUT + jack 8 DUT - jack 9 Shielding grounding jack 1.2.Inspection When you get a new LCR meter, please check the instrument and its accessories. If something is damaged or missed, please contact the store you bought the instrument from for adjustment or replacement. 1.3 Accessories MS5308 LCR digital bridge meter SMD test probe Upper computer program CD Kelvin test clip (one pair) IR data line External power supply Page 1 of 18

MS5308 panel Page 2 of 18

2. Safety instructions: Operating environment and condition: Elevation <2000 m Relative humidity (RH) 80%RH Operating temperature 0 40 C Note: DO NOT input voltage at the measurement port. When measuring capacitance, please discharge first then measure, otherwise, the meter will be damaged. Storage and maintenance: Do not use alcohol or other solvents to clean the meter. If it will not be used for long time, please remove battery and put the meter in a dry and clean environment. 3. Description: 3.1 Definition Description APO: Auto power off LCR: This character showing on the LCD means that the tester works in automatic identification mode L P: Inductance parallel connection measurement mode L s: Inductance series connection measurement mode C P: Capacitance parallel connection measurement mode C s: Capacitance series connection measurement mode R P: Resistance parallel connection measurement mode R s: Resistance series connection measurement mode DCR: Resistance DC measurement mode D: Wastage factor Q: Quality factor θ : Phase angle value ESR: Equivalent resistance DUT: Object for measuring 3.1 Impedance parameter description (see Figure Ⅰ) Z= R s +jx s = Z θ R s- = Z Cosθ X s = Z Sinθ X s /R s =Tanθ θ =Tan -1 (X s /R s ) Page 3 of 18

If θ > 0, it means that the measured object is resistant, if θ < 0, it means that that the measured object is capacitive. 3.2 Series-parallel connection mode description This meter has series and parallel measurement modes. When the capacitance value of the measured object is large or inductance value is small, use the series mode for more accurate results. When the capacitance value of the measured object is small or inductance value is large, use the parallel mode for more accurate results. This meter can select the measurement mode automatically according to the measured object. 4. Functional characteristics description: 1. 19,999 (main)/1,999 (secondary) dual LCD display 2. LCR measures with automatic identification and automatic measurement range 3. L\C\R single measurement selection 4. Resistance measurement in DCR mode 5. D/Q/θ /ESR display on the secondary display 6. Series or parallel measurement modes are selectable 7. Comparison function under single measurement 8. Test frequency 100/120/1k/10k/100k is selectable in AC mode 9. The selection feature for measured components with the same series 10. Battery power display, auto power off if meter is not operated for 5 minutes. 11. With infrared transmission interface, the meter is secure (supporting hot plug). With special software, the meter is easily managed. 12. See table 1-3 for measurement accuracy and scope Remarks: This accuracy is the measurement standard. In DUT jack, the meter-specific probe should be used if required. Measurement with probe may be influenced by external environment. To avoid inaccurate measurements, please keep away from strong magnetic sources. Page 4 of 18

Measurem ent item Measurement frequency 100Hz/120 100Hz/120 100Hz/120 Hz Measurem ent 200.00Ω scope Resolutio n 0.01Ω Accuracy 1.0%+5d 2.0000KΩ 0.1Ω 0.3%+5d 20.000KΩ 1Ω 0.3%+5d Table 1 Resistance measurement scope Page 5 of 18

Measurem ent item R S /R P 100Hz/120 200.00KΩ 0.01kΩ 0.5%+5d 100Hz/120 Measurement 2.0000M Measure Resoluti 0.1kΩ Accuracy 1.0%+5d frequency 100Hz/120 20.000M ment 20.000nF on 1pF 1kΩ 1.0%+5d 1.0%+5d 100Hz/120 200.00M 200.00nF 0.01nF 0.1MΩ 0.5%+5d 2.0%+5d 1kHz Hz 20.000Ω 0.001Ω 1.0%+5d 1kHz 200.00Ω 0.01Ω 0.3%+5d 1kHz 2.0000KΩ 0.1Ω 0.3%+5d 1kHz 20.000KΩ 1Ω 0.3%+5d 1kHz 200.00KΩ 0.01kΩ 0.5%+5d 1kHz 2.0000M 0.1kΩ 1.0%+5d 1kHz 20.000M 1kΩ 2.0%+5d 1kHz 200.0MΩ 0.1MΩ 5.0%+5d 10kHz 20.000Ω 0.001Ω 1.0%+5d 10kHz 200.00Ω 0.01Ω 0.5%+5d 10kHz 2.0000KΩ 0.1Ω 0.3%+5d 10kHz 20.000KΩ 1Ω 0.5%+5d 10kHz 200.00KΩ 0.01kΩ 1.0%+5d 100kHz 20.000Ω 0.001Ω 1.0%+5d 100kHz 200.00Ω 0.01Ω 1.0%+5d 100kHz 2.0000KΩ 0.1Ω 1.0%+5d 100kHz 20.000KΩ 1Ω 2.0%+5d Note: This accuracy is the measurement standard when D <0.1, if D> 0.1, it should be multiplied by the extraction of a root of 1 + D 2 Table 2 Capacitance measurement scope Page 6 of 18

Measurem ent item C S /C P 100Hz/120 2000.0nF 0.1nF 0.5%+5d Measurement 100Hz/120 frequency 100Hz/120 100Hz/120 Measureme 20.000uF 1nF Resolutio 0.5%+5d Accuracy nt 20.000mH 200.00uF scope 0.01uF n 1uH 1.0%+5d 200.00mH 2000.0uF 0.1uF 0.01mH 2.0%+5d 0.5%+5d 100Hz/120 20.00mF 0.1mF 2.0%+5d 1kHz 2000.0pF 0.1pF 1.0%+5d 1kHz 20.000nF 1pF 1.0%+5d 1kHz 200.00nF 0.01nF 0.5%+5d 1kHz 2000.0nF 0.1nF 0.5%+5d 1kHz 20.000uF 1nF 0.5%+5d 1kHz 200.00uF 0.01uF 1.0%+5d 1kHz 2000.0uF 0.1uF 1.0%+5d 10kHz 200.00 0.01pF 1.0%+5d 10kHz 2000.0pF 0.1pF 1.0%+5d 10kHz 20.000nF 1pF 1.0%+5d 10kHz 200.00nF 0.01nF 1.5%+5d 10kHz 2000.0nF 0.1nF 2.0%+5d 100kHz 200.00 0.01pF 2.0%+5d 100kHz 2000.0pF 0.1pF 1.0%+5d 100kHz 20.000nF 1pF 2.0%+5d 100kHz 200.00nF 0.01nF 5.0%+5d Note: This accuracy is the measurement standard. When D <0.1, if D> 0.1, it should be multiplied by the extraction of a root of 1 + D 2 Table 3. Inductance measurement scope Page 7 of 18

L S /L P 100Hz/120 2000.0mH 0.1mH 0.5%+5d 100Hz/120 20.000H 1mH 0.5%+5d 100Hz/120 200.00H 0.01H 1.0%+5d 100Hz/120 2000.0H 0.1H 1.0%+5d 100Hz/120 20.000kH 1H 2.0%+5d 1kHz 2000.0uH 0.1uH 1.0%+5d 1kHz 20.000mH 1uH 0.5%+5d 1kHz 200.00mH 0.01mH 0.5%+5d 1kHz 2000.0mH 0.1mH 1.0%+5d 1kHz 20.000H 1mH 1.0%+5d 1kHz 200.00H 0.01H 2.0%+5d 1kHz 2000.0H 0.1H 5.0%+5d 10kHz 200.00 uh 0.01uH 1.0%+5d 10kHz 2000.0uH 0.1uH 0.5%+5d 10kHz 20.000mH 1uH 0.5%+5d 10kHz 200.00mH 0.01mH 1.5%+5d 10kHz 2000.0mH 0.1mH 2.0%+5d 10kHz 20.000H 0.001H 5.0%+5d 100kHz 20.000 uh 0.001uH 1.0%+5d 100kHz 200.00 uh 0.01uH 2.0%+5d 100kHz 2000.0uH 0.1uH 2.0%+5d 100kHz 20.000mH 1uH 2.0%+5d 100kHz 200.00mH 0.01mH 5.0%+5d Note: This accuracy is the measurement standard. When D <0.1, if D> 0.1, it should be multiplied by the extraction of a root of 1 + D 2 5. Meter probe measurement Use Kelvin clip or SMD clamp to connect according to the Page 8 of 18

following diagram: Schematic diagram for using SMD clamp to measure Remarks: insert the plug correctly according to the diagram. Measurement can t be done if inserted incorrectly Page 9 of 18

Schematic diagram for using Kelvin clip to measure Page 10 of 18

Remarks: insert the plug correctly according to the diagram. Measurement can t be done if inserted incorrectly. 6 Measurement operation description: 6.1. Automatic measurement: When the instrument is turned on, the instrument will enter automatic identification mode by default. At this time, insert the object to be measured to the measurement side. The instrument will automatically recognize that the object to be measured is capacitive resistance or inductor and display the measurement value in the main display, and display a corresponding D/Q/θ /value in the secondary display. In this mode, you can change measurement frequency by operating Frequency. 6.2. Single measurement When the instrument is turned on, the instrument will enter automatic identification mode by default. At this time, you can select L, C, R, DCR and other single measurement modes by operating Function button. Read the measurement value on the LCD display after inserting the object to be measured and selecting the proper mode. In L, C, R mode, you can change the measurement frequency by operating Frequency button, and you also can operate Series/Parallel buttons to select parallel connection measurement or series connection measurement. 6.3. Comparison and selection When the instrument is turned on, the instrument will be switched to single measurement mode for the objects to be selected. Connect the sample objects to be selected at measurement port. At this time, you can operate Comparison Page 11 of 18

button to enter comparison and selection mode. PASS or FAIL, will display on the main display and the measurement value of current object will display on the secondary display. In this state, press Setup button to select parameters, and the sample value and error will display on the LCD. You can modify sample value and error by operating direction arrows. Select the modification item by operating Ok button, and confirm the settings. Press Comparison button again to quit selection mode. 6.4. Deviation proportion measurement When the instrument is turned on, the instrument will switch to single measurement mode for the objects to be tested. Insert reference object in measurement port, press Relevant Measurement button to save the current vale (D CUR ) as reference value (D REF ). At this time, REL will display on the LCD. Insert the object for measuring in the measurement port and press Relevant Measurement button again. At this time, REL will flash on the LCD the reference value will display on the main display, and the deviation proportion REL% will display on the secondary display, REL%=(D CUR -D REF )/D REF *100%. When D CUR is more than two times of D REF, OL% will display on the secondary display. Press Relevant Measurement button for more than 2 seconds to quit the measurement state. 6.5 Data Hold function: press Hold button to stop reading measurement value and show the current measurement value on the main display continuously. At this time, only Communication and Backlight keys are available. Press the Hold key again to return normal measurement mode. 7. Additional functions Page 12 of 18

7.1 Auto power off function: To prolong battery life, when the external power supply is not used, APO will display on the LCD, which means that auto power off is available. The instrument will automatically power off without any operation for 5 minutes. 7.2 Backlight function: backlight will be enabled when you press Backlight button. Press Backlight button again to turn off the backlight. The backlight will turn off automatically after it is on for 60 seconds. 7.3 Battery power detection function: The meter has a battery power detection function. Battery power includes four levels and displays on the LCD screen. When displays for battery, please replace battery. This meter uses 8 1.5V SIZEAA battery. Batteries with the same model should be used for battery replacement. Please remember that you can t use the meter until the rear cover is tightened. 8 Upper computer software installation: Open CD Click LCR_TERSTER.MSI to enter the following screen based on the diagram Page 13 of 18

Click NEXT to enter the next screen Page 14 of 18

Click change to select the position to be changed Click OK to enter the next screen based on the diagram Click NEXT Page 15 of 18

Click INSTALL and start installing Page 16 of 18

Click finish, and the following icon will show on the desk Installation complete 9 Data transmission: Press Communication button. The RS232 symbol will show on the LCD display. At this time, you can send data via infrared port. Connect the infrared communication line between computer and MS5308. When the software is opened on the computer, the screen is shown as following Figure Ⅰ. Click CONNECT in the screen, the screen will be shown as following Figure Ⅱ, and start receiving data. The number of data recording groups can be up to 50000. Click the storage mark on the screen to save the Page 17 of 18

recordings in the format of EXCEL or text. Screen Ⅰ Screen Ⅱ Page 18 of 18