Type A. BWSC CAD Standards for Site Plans (Design and As-Built) Format. Scale. Fonts, Linetypes, Shapes

Similar documents
Minimum Drawing & Electronic Submittal Requirements For Record Drawings /As-Builts

Charlotte County Utilities DESCRIPTION

CAD STANDARDS & DRAWING RECORD REQUIREMENTS

Record Drawing Standards for Projects Version 2.1

UTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1

3. DESIGN SPECIFICATIONS

CONSULTANT: Wantman Group, Inc SERVICE AUTHORIZATION NO. _12-03 FOR CONSULTING SERVICES CITY PROJECT NO CONSULTANT PROJECT NO.

New Jersey American Water Geospatial Asset Planning Department. CAD to GIS Submission and Format Conversion

CITY OF LOMPOC DEVELOPMENT ASSISTANCE BROCHURE ENCROACHMENT PERMITS AND PUBLIC IMPROVEMENT PLANS

SCHEDULE 10 ENGINEERING DRAWING SUBMISSION

ACWWA DRAWING SUBMITTAL INFORMATION - UTILITY DRAWING REQUIREMENTS

Existing and proposed contours at 1-foot intervals. The fill and/or excavation quantities in cubic yards.

ELECTRONIC DRAFTING GUIDELINES

APPENDIX 1: CONSTRUCTION PLAN CHECKLIST

Section 4: Ontario Realty Corporation CAD Standards and Guidelines

SECTION 2.0 PREPARATION OF MASTER PLANS, CONSTRUCTION PLANS, AND RECORD DRAWINGS

Survey Requirements. Design Guidelines and Standards. June Office of the University Architect

3. The PAC (Permit Application Center) will notify the design professional of plan review results.

SECTION 9.00 AS-BUILT DRAWING REQUIREMENTS SUB-INDEX

Council Policy Engineering Drawing Submission Requirements

Autodesk AutoCAD Architecture 2015 Fundamentals

CITY OF TUMWATER 555 ISRAEL RD. SW, TUMWATER, WA (360)

CHAPTER 11. Plan Standards

1.1 GENERAL RECORD DRAWING REQUIREMENTS

UNIVERSITY OF ROCHESTER DESIGN STANDARDS FEBRUARY 29, 2012

How to Design and Submit a DOT Project with Civil 3D

It is expected that this standard will evolve over time; however the use of this standard should remain consistent within individual projects.

SECTION III SUBMITTALS AND APPROVALS

MINIMUM DRAWING REQUIREMENTS FOR WATER AND SEWER LINE PROJECTS

Table of Contents. List of Tables

List of Figures. List of Forms

10010 RECORD DRAWING INFORMATION

Table of Contents. List of Tables

Dean Muccio AutoCAD Interior Designer. for the. AutoCAD for Mac and PC SDC. Better Textbooks. Lower Prices.

DIGITAL DATA SUBMISSION STANDARDS Procedures and Guidelines

AutoCAD Architecture 2018 Fundamentals

NEWTON COUNTY WATER AND SEWERAGE AUTHORITY RESIDENTIAL, COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL SUBDIVISIONS CONSTRUCTION PLANS CHECK LIST

Dean Muccio. AutoCAD 2018 for the. Interior Designer. AutoCAD for Mac and PC SDC. Better Textbooks. Lower Prices.

WATER WASTEWATER CAD DELIVERABLES SUBMISSION STANDARDS

Section E NSPS MODEL STANDARDS FOR TOPOGRAPHIC SURVEYS Approved 3/12/02

Clarifications in italics added July 2018

CHECKLIST PRELIMINARY SUBDIVISION AND PRELIMINARY SITE PLAN

City of Massillon Site Plan Checklist

SECTION 100 PRELIMINARY CONSIDERATIONS & INSTRUCTIONS

Miami University. Physical Facilities Department. CAD Standards. April 2004

Specifications for Land Surveys January 2014 Version

Anne Arundel County Dept. of Inspections and Permits Water Sewer Plan Checklist

CCWA As-Built CAD Standards Effective Date: June 1, 2002 Latest Revision: March 2016

Introduction To Computer-Aided Boat Design (CAD)

ACSA PLAN REVIEW CHECKLIST (Guideline Only) (4) Standard water and sewer general plan notes (attached).

AutoCAD Standards University of California, Santa Cruz Physical Planning & Construction

Plan Submittal and Review Checklist

Completed project drawing (dimensions added for reference)

SECTION SITE SURVEYS

APPENDIX D: DRAWING SUBMISSION STANDARDS

CITY OF MUSKEGO DRAFTING STANDARDS

Using Layers and Object Properties

Create styles that control the display of Civil 3D objects. Copy styles from one drawing to another drawing.

AutoCAD Civil 3D 2013 South African Country Kit

APPENDIX K CITY OF SAN BERNARDINO MUNICIPAL WATER DEPARTMENT AUTOCAD STANDARDS

Chapter 6 Title Blocks

AutoCAD Civil 3D 2009 ESSENTIALS

September 21, Mannik Smith Group 1771 North Dixie Highway Monroe, Michigan RE: LA Fitness City File No.: CVLP

Harris County Flood Control District. CAD Standards Manual

BRASELTON WATER AND WASTEWATER DEPARTMENT CONSTRUCTION PLAN REVIEW CHECKLIST May 2006

1: INTRODUCTION TO AUTOCAD

OVERRIDE PRESETS. Use the properties window on individual lines to accomplish this change.

CITY OF LA MARQUE CHAPTER GRAPHIC REQUIREMENTS CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS

Engineering Department DRAWING STANDARD SPECIFICATIONS

Survey Data and TOPO Checklist

CADD & Civil 3D User Guidelines

PART XII: TOPOGRAPHIC SURVEYS

CHAPTER 11 SURVEY CADD

Exercise 1: The AutoCAD Civil 3D Environment

Zooming in on Architectural Desktop Layouts Alexander L. Wood

Come Back to the Other Side - AutoCAD for MicroStation Users

Stanford University-Facilities Design Guideline SECTION Plans Review Submission Guidelines

City of Kitchener Infrastructure Services Department Engineering Services Division. CAD Standards for Engineering

SITE PLAN, SUBDIVISION & EXTERIOR DESIGN REVIEW PROCESS

KC Water Rules and Regulations For Water Main Extensions and Relocations

AutoCAD LT Drawing Formats

Montana Association of Registered Land Surveyors Conference 2013

Revit Structure 2012 Basics:

06/17/02 Page 1 of 12

Rhinoceros modeling tools for designers. Using Layouts in Rhino 5

B.2 MAJOR SUBDIVISION PRELIMINARY PLAN CHECKLIST

What is a Survey? The site plan is usually based on an professional land survey.

ADDENDUM NO. 01 Charlotte Douglas International Airport FAR Part 150 Noise Exposure Map Update January 12, 2014

Mastering AutoCAD 2D

Tutorial Guide to AutoCAD 2015

Engineering and Construction Services Division Construction Drawings for Sewers and Watermains. T No. Revision T No. Revision Remarks All T drawings

ARC By default AutoCAD will draw an ARC through three selected points. Options can be set at the start and within the command.

Chapter 13 Plan Submittals

Digital Drawings Submittal Process

Plan Preparation Checklist

Project Booklet. Structural Drafting with AutoCAD

BASIC CADD DRAWING PROCEDURES

CMW DELIVERABLES SPECIFICATION Version 1.0

COURSE OUTLINE. Course Number Course Title Credits DRA190 Introduction to Computer-Aided Drafting 2

Porter County Plan Commission

Transcription:

BWSC CAD Standards for Site Plans (Design and As-Built) Type A The following CAD standards are for Type A application and involve no work in Public Street, except for connection(s) to the Boston Water and Sewer Commission (BWSC) facilities and no addition or modification to BWSC facilities. The BWSC Engineering Services Department will determine which type of application will apply to you. Format All drawings submitted to the Boston Water and Sewer Commission (BWSC) must be provided on disk or CD in DWG format. DXF and DGN (Microstation) formats must be converted to DWG format to be accepted by BWSC. Version of AutoCAD software must be at least Release 14 up to Release 2016. Prior to delivery to the BWSC, the following must be done on all drawings: 1. If the site plan itself is a block, it must be exploded. 2. PURGE all unused objects and AUDIT all drawings. 3. The ZOOM EXTENTS command must be issued in Model Tab (Model Space) and in each layout (Paper Space). 4. Lost objects must be removed from each tab. Scale All drawings provided must be done in MODEL SPACE at real scale (1:1) and must be printable from a layout (PAPER SPACE) at scale 1 =1 (1:1). BWSC Standard scale for viewports is 1 =20. Other scales must be pre-approved by the BWSC. The height of text when printing drawings from Paper Space at the scale 1:1 must not be smaller than 0.09 inch. Fonts, Linetypes, Shapes The BWSC will not accept drawings that require special font files, linetypes, and shape files. All fonts and linetypes used on as-built plans should be selected among the fonts and linetypes provided by Autodesk with their software. Special linetypes that require shape files are not acceptable. Cad Standards For Site Plans.Doc Page 1 of 5

Layers All drawings submitted to the BWSC must comply with the following layers and colors: Name On Freeze Lock Color Linetype Plot BWSC-DRAIN 104 CONTINUOUS Proposed and as-built drain pipes, catch basins, manholes, laterals related annotations, etc. Existing drain on separate layer color 253 BWSC-SEWER 30 CONTINUOUS Proposed and as-built sewer and combined sewer pipes,manholes, laterals and related annotations, etc. Existing sewer on separate layer color 253 BWSC-WATER 160 CONTINUOUS Proposed and as-built water pipes, valves, hydrants, service connections, meter, related annotations, etc. Existing water on separate layer color 253 BWSC-DIM 240 CONTINUOUS Dimensions, measurements, ties, and stations to proposed and as-built water, sewer and drain facilities, miscellaneous as-built annotations. BWSC-Street Names 180 CONTINUOUS For street names only. Color 180 is defined with a line width of 0.70 mm in all BWSC PC3 files. Building Outline 7 CONTINUOUS Thick polyline for proposed building outline in black. Prop-Roadway 7 CONTINUOUS For proposed or new roadways, property limits. Limited linework and annotations if possible ALL OTHER UTILITIES LAYERS in 253 CONTINUOUS MODEL space All existing and proposed utilities, existing water, sewers, and drains, existing roadways, sidewalks, parking lots, vegetation, proposed curbs, existing and proposed electric, telephone, gas, etc. ALL LAYERS IN TITLE BLOCKS 7 CONTINUOUS Frame, text and all object in title block must be black The color of all AutoCAD entities must be set to BYLAYER. Structural and other details can be in any color except yellow, cyan and the colors used above (30, 104, 160, 180, 240). For the applicant s convenience, the BWSC will provide a drawing file with the above layers already created. This file may be inserted in your drawings. External Reference and Image Files When submitting Site Plan Record Plan Drawings to Engineering Customer Service, please make sure that there are no External Cad Standards For Site Plans.Doc Page 2 of 5

Reference files (XREFS) and external images included in the Drawing. You can choose to bind a XREF to a drawing using either the Bind option or the Insert option. The option you choose determines how the file names are merged from the reference file into the drawing file. Using Bind will avoid overriding existing block definitions. If you use Insert, the symbol names are merged into the drawing file. If duplicate symbols exist, AutoCAD uses the symbols already defined in the current drawing and overrides them. External images must be removed from drawings and re-inserted as an embedded (OLE) object. (Copying and pasting images from MS Word is a quick method for embedding images). Surveyed Information AEC survey points, if available should be present in the drawing on frozen or non-printable layers. If available, benchmark elevation and description should be noted with location description. Annotations The default Standard text style and Dimension Style must not be used. The applicant must create their own text styles and dimension styles. The ASBUILT text style included in the BWSC template should be used for proposed (design) and for as-built annotations. As-built and proposed annotations should be on the appropriate BWSC layer (see table above). Miscellaneous proposed annotations should be black. Street names must be at least 0.30 inch high on prints. The Street Names layer with color 180 should be used so that street names will be printed in black with a line width of 0.80 mm. No other entities should be present on this layer. Private streets must be named and annotated with the words (PRIVATE WAY). Annotations should be set to print no smaller than 0,09 inch high from the layout (PAPER SPACE). Fonts used must be selected among the fonts present on the Autodesk CD. Fonts used for logos should be exploded. Windows default True Type Fonts Arial, Swiss, and Times are also acceptable. Size and type of pipes as well as year of installation should be noted. Cad Standards For Site Plans.Doc Page 3 of 5

Hydrant manufacturer must be noted near hydrants. Valves manufacturer must be noted near water valves. Water meter number and MTU serial number must be noted near the meter if known. Sump manholes should be noted as such. Depths o Rim elevations and inverts taken must refer to Boston City Base (BCB) elevation (NGVD Mean Sea Level Datum 1929-5.65). o Depths on valves must be indicated as well as on tees, crosses, and bends. o For all manholes, inverts must be noted. Inverts must start with the outlet of the manhole, then all inverts IN must be listed from the outlet in a clockwise order. If two or more inverts are the same, they all must be listed. o Rim elevations must be taken and noted on plans for all proposed manholes and catch basins. Stationing o If stationing has been performed, it should be left on the drawing(s) on a black (color 7) layer. o When possible STA 0+00 should be aligned with the corner of the property line of the street where work is taking place. o All manholes, valves, tees, crosses, bends and service connection must be stationed. Symbols Symbols provided in the BWSC template file and in the BWSC Symbol Library file must be used as indicated. Symbols are to be used as provided, scale 1:1 in model space, not exploded. The valve symbol may be scaled to fit pipe. Bends must be notes along water mains as horizontal or vertical. Complex situations should have a detailed view and/or picture. When manhole is not centered on the pipe, it must be shown as such. A wide variety of other symbols (AutoCAD 2006-2016 dynamic blocks format only) is available upon request from the Commission from devlindm@bwsc.org. Cad Standards For Site Plans.Doc Page 4 of 5

Wye connections must be inserted so that they are in the direction of the flow. Dimensions The default Standard dimension style must not be used. The applicants must create their own dimension styles or use the As-Built dimension style provided. Swing ties must be taken to locate valves, tees, crosses, bends, manholes, catch basins, service connections, etc. Offsets from the property line must be taken at valves, tees, crosses, bends, manholes, service connections, and every 50 feet along the pipes. Profiles Profiles must be created for as-built sewers and drains and show the following: o Existing grade or finished grade must be shown and based on Boston City Base elevation. o Station number, rim, and invert elevations must be noted at each manhole. o If a profile is provided, the color of layers created by the software must be changed according to the above chart. Pipes Although the BWSC standard is to show pipes widths at real size, proposed and as-built pipes may be represented with a solid polyline th with a printed width of at least 1 / 16 of an inch (1.50 mm). Services pipes must be shown with service gates or corporation stop and up to the meter. Fire pipes must be shown up to the OS&Y valve or to the cross connection device. Abandoned services left in place should be noted on plans. Sewer and drain connections must be shown up to the building. Questions about the BWSC CAD Standards should be directed to: Denise Devlin Director of CAD Tel: 617-989-7424 devlindm@bwsc.org Cad Standards For Site Plans.Doc Page 5 of 5

The Inspection Sign-Off Schedule must be included with each proposed and as-built site plan submission. See AutoCAD template for form. Item No. To Be Submitted with Proposed Plans INSPECTION SIGN-OFF SCHEDULE Service Connections To Be Submitted with As-Built Plans Description of Service Qty BWSC Inspector/Date Comments 1 2" Domestic Service 1 Tom Krabey / 3.23.09 See GSA 1235 2 4" Fire Pipe Service 1 Tom Krabey / 3.23.09 See GSA 1236 3 6" Drain Overflow 1 Leo Grastorf / 3.24.09 Modified Installation 4 Infiltration (6' dia. Drywell) 1 Leo Grastorf / 3.24.09 GSA 1234 5 Particle Separator 1 Leo Grastorf / 3.24.09 Not Installed 6 Cut & Cap Water 1 Leo Grastorf / 3.24.09 Completed 7 Cut & Cap Sewer 1 Leo Grastorf / 3.24.09 Completed 8

The As-Built Certification form must be included with each as-built site plan submission. See AutoCAD template for form. AS-BUILT PLAN CERTIFICATION I certify that these plans were prepared in accordance with the Boston Water and Sewer Commission ( Commission ) minimum standards for As-built plans. The undersign further certifies that the survey measurements, materials, sizes, field conditions and related information are based on both a field survey and/or the latest plan of record available. Engineer s Name, P.E./P.L.S. Date Construction Timetable P. E. Number: Expiration Date: Actual Construction Start Date: Actual Construction Completion Date: