Simulation & Hardware Implementation of APFC Meter to Boost Up Power Factor Maintain by Industry.

Similar documents
Power Factor. Power Factor Correction.

ARDUINO BASED POWER FACTOR CORRECTION

Electrical Theory. Power Principles and Phase Angle. PJM State & Member Training Dept. PJM /22/2018

AC Power Instructor Notes

POWER FACTOR CORRECTION USING BOOST CONVERTER

ELG 4125: ELECTRICAL POWER TRANSMISSION AND DISTRIBUTION: TUTORIAL 1: - BY:

Question Paper Profile

POWER FACTOR CORRECTION AND ITS PITFALLS

CHAPTER 3 IMPROVEMENT OF LOAD POWER FACTOR USING FACTS CONTROLLERS

Aligarh College of Engineering & Technology (College Code: 109) Affiliated to UPTU, Approved by AICTE Electrical Engg.

AUTOMATIC POWER FACTOR CORRECTION AND MONITORING BY USING PIC MICROCONTROLLER

Power Factor Compensation Using PIC

Improve Power Factor and Reduce the Harmonics Distortion of the System

Study of Power Factor Correction in Single Phase AC-DC Converter

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM I (EE, EN, EC, CE)] QUIZ TEST-3 (Session: ) Time: 1 Hour ELECTRICAL ENGINEE

Power. Power is the rate of using energy in joules per second 1 joule per second Is 1 Watt

Chapter 7. Copyright The McGraw-Hill Companies, Inc. Permission required for reproduction or display.

PRUDENT PRACTICES TO IMPROVE POWER FACTOR AND REDUCE POWER LOSS.

POWER FACTOR CORRECTION OF MACHINE LABORATORY AND CNC MACHINE BY USING IPFC CONTROLLER

FGJTCFWP"KPUVKVWVG"QH"VGEJPQNQI[" FGRCTVOGPV"QH"GNGEVTKECN"GPIKPGGTKPI" VGG"246"JKIJ"XQNVCIG"GPIKPGGTKPI

Sizing Generators for Leading Power Factor

Application Guidance Notes: Technical Information from Cummins Generator Technologies

Maintaining Voltage-Current Phase Relationships in Power Quality Monitoring Systems

Power Factor Correction of Inductive Loads using PLC

TRANSFORMER OPERATION

Thyristorised Automatic Power Factor

Experiment 45. Three-Phase Circuits. G 1. a. Using your Power Supply and AC Voltmeter connect the circuit shown OBJECTIVE

ENERGY SAVINGS THROUGH POWER CONDITIONING WITH THE PowerGUARD SYSTEM

Power Factor Correction Using SCR and Microcontroller

Power Factor Improvement Using Static VAR Compensator

Power Factor improved by Variable Speed AC Drives By Mauri Peltola, ABB Oy, Drives

APPLICATION NOTE - 018

CHAPTER 4 HARMONICS AND POWER FACTOR

Monitoring And Control Over Power Factor By Using Pic Micro-Controller

ELECTROMAGNETIC INDUCTION AND ALTERNATING CURRENT (Assignment)

Downloaded from / 1

Transformer & Induction M/C

Alternating Current Page 1 30

Reducing Total Harmonic Distortion with Variable Frequency Drives

Power System Analysis Prof. A. K. Sinha Department of Electrical Engineering Indian institute of Technology, Kharagpur

Influence of Switching Elements on Harmonics and Power Factor Improvement

A Single Phase Power Factor Correction Using Programmable Interface Circuit

Hours / 100 Marks Seat No.

Practical Transformer on Load

HARMONICS CAUSES AND EFFECTS

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT

CHAPTER 2. Basic Concepts, Three-Phase Review, and Per Unit

Design and Implementation of Economical Power Factor Transducer

A Thyristor Controlled Three Winding Transformer as a Static Var Compensator

Power Factor and Power Factor Correction

RESONANT TRANSFORMER

148 Electric Machines

Harmonic control devices

HIGH VOLTAGE ENGINEERING(FEEE6402) LECTURER-24

TUNED AMPLIFIERS 5.1 Introduction: Coil Losses:

ELECTRONIC CONTROL OF A.C. MOTORS

2.0 AC CIRCUITS 2.1 AC VOLTAGE AND CURRENT CALCULATIONS. ECE 4501 Power Systems Laboratory Manual Rev OBJECTIVE

Chapter L Power factor correction and harmonic filtering

~=E.i!=h. Pre-certification Transformers

International Journal of Advance Engineering and Research Development AUTOMATIC POWER FACTOR CONTROL USING ARDUINO UNO

ECET Modern Power

The Discussion of this exercise covers the following points: Phasor diagrams related to active and reactive power

DSP-BASED CURRENT SHARING OF AVERAGE CURRENT CONTROLLED TWO-CELL INTERLEAVED BOOST POWER FACTOR CORRECTION CONVERTER

Practical Tricks with Transformers. Larry Weinstein K0NA

CHAPTER 4. Distribution Transformers

ECE 2006 University of Minnesota Duluth Lab 11. AC Circuits

University of Pennsylvania Department of Electrical and Systems Engineering. ESE 206: Electrical Circuits and Systems II - Lab

Power Factor Improvement Using Thyristor Switched Capacitor Using Microcontroller Kacholiya Saurabh 1, Phapale Sudhir 2, Satpute Yuvraj 3, Kale.S.

CHIEF ENGINEER REG III/2 MARINE ELECTROTECHNOLOGY

SECTION 4 TRANSFORMERS. Yilu (Ellen) Liu. Associate Professor Electrical Engineering Department Virginia Tech University

Address for Correspondence

CHAPTER 2. Transformers. Dr Gamal Sowilam

How Harmonics have led to 6 Power Factor Misconceptions

VALLIAMMAI ENGINEERING COLLEGE

Reg. No. : BASIC ELECTRICAL TECHNOLOGY (ELE 101)

Module 7. Transformer. Version 2 EE IIT, Kharagpur

SRI VIDYA COLLEGE OF ENGG AND TECH

Generator Advanced Concepts

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

WALJAT COLLEGES OF APPLIED SCIENCES In academic partnership with BIRLA INSTITUTE OF TECHNOLOGY Question Bank Course: EC Session:

Spring 2000 EE361: MIDTERM EXAM 1

Automatic Power Factor Correction by Using Synchronous Condenser with Continuous Monitoring.

Technical News. Part 2: Harmonics. The link between harmonics and power factor. Industrial Electrical and Automation Products, Systems and Solutions

Transformers. gpmacademics.weebly.com

An induced emf is the negative of a changing magnetic field. Similarly, a self-induced emf would be found by

Volume I Issue VI 2012 September-2012 ISSN

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

ENGINEERING. Unit 4 Principles of electrical and electronic engineering Suite. Cambridge TECHNICALS LEVEL 3

Experiment No. Experiments for First Year Electrical Engg Lab

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

UNIVERSITY OF TECHNOLOGY By: Fadhil A. Hasan ELECTRICAL MACHINES

STATCOM WITH POD CONTROLLER FOR REACTIVE POWER COMPENSATION Vijai Jairaj 1, Vishnu.J 2 and Sreenath.N.R 3

Alternating Current Study Guide. Preface. This module is DIFFICULT.

Single-Phase Transformation Review

IMPROVING POWER QUALITY AND ENHANCING THE LIFE OF POWER EQUIPMENT, IN RAILWAY TSSs

Effects of Harmonic Distortion I

Voltage Compensation of AC Transmission Lines Using a STATCOM

Contents. Core information about Unit

Power Quality Monitoring and Power Metering Tutorial

POWER FACTOR CORRECTION AND HARMONIC CURRENT REDUCTION IN DUAL FEEDBACK PWM CONTROLLED AC/DC DRIVES.

Transcription:

Simulation & Hardware Implementation of APFC Meter to Boost Up Power Factor Maintain by Industry. Bhargav Jayswal 1, Vivek Khushwaha 2, Prof. Pushpa Bhatiya 3 1.2 B. E Electrical Engineering, Vadodara Institute of Engineering, Vadodara, Gujarat, India 3: Assistant Professor in Electrical Engineering Department, Vadodara Institute of Engineering, Vadodara, Gujarat, India ---------------------------------------------------------------------***--------------------------------------------------------------------- Abstract - In recent years, the power quality of the ac system has become great concern due to the rapidly increased numbers of electronic equipment, power electronics and high voltage power system. most of the commercial and industrial installation in the country has large electrical loads which are severally inductive in nature causing lagging power factor which gives heavy penalties to consumer by electricity board. This situation is taken care by APFC.Automatic Power factor correction is the capacity of absorbing the reactive power produced by a load. In case of fixed loads, this can be done manually by switching of capacitors, however in case of rapidly varying and scattered loads it becomes difficult to maintain a high power factor by manually switching on/off the capacitors in proportion to variation of load within an installation. This drawback is overcome by using an APFC panel. In this paper measuring of power factor from load is done by Arduino and trigger required capacitors in order to compensate reactive power and bring power factor near to unity. Key Words: Power factor, reactive power Arduino, Penalty, capacitor bank, APFC Meter. 1. INTRODUCTION The low power factor leads to the increase in the load current, increase in power loss, and decrease in efficiency of efficiency of the overall system. In previous various method use for power factor correction in all this method, the switching of the capacitor is manual. In this paper we are using a method of the reactive power compensation by capacitor switching with automatic control using Arduino. 1.1 POWER FACTOR THEROY A) Types of power: Active Power: The actual amount of power being used, or dissipated, in a circuit is called the true power. It is measured in watts and is symbolized mathematically by the capital letter P. Active power is a function of circuit s dissipative element, such as resistances(r). Reactive Power: Reactive loads such as inductors and capacitors dissipate zero power, but the fact that they drop voltage and draw current gives the perception that they do dissipate power. This dissipated power is called the reactive power and is measured in Volt-Amps-Reactive (VAR) and is symbolized by the capital letter Q, and it is the function of circuit s reactance (X). Figure 1: Power Triangle Apparent Power: The combination of the active and reactive power is called apparent power. It is the product of a circuit s voltage and current, without reference to phase angle. Apparent power is measured in Volt-Amps (VA) and is symbolized by the capital letter S. Apparent power is a function of a circuit s total impedance (Z). 1.2 Power Factor Power factor is the ratio between the active power (kw) to the total apparent power (kva) consumed by an a.c. electrical equipment or a complete electrical installation. Power Factor (PF) = Active power / Apparent power It is a measure of how efficiently electrical power is converted into useful work output. The ideal power factor is unity, or one. Anything less than one means that extra power is required to achieve the actual task at hand. A poor power factor can be the result of either a significant phase difference between the voltage and current at the load terminals, or it can be due to a high harmonic content or distorted current waveform. A poor power factor due to an inductive load can be improved by the addition of power factor correction. Power factor is the relation between current and voltage. So power factor is also defined as the cosine of the phase difference between current and voltage. It can be mathematically expressed as cosø, where ø is the phase difference between current and voltage. 2018, IRJET Impact Factor value: 6.171 ISO 9001:2008 Certified Journal Page 3757

Basically AC power circuits, have resistive loads (like heaters) or inductive loads (like choke) or capacitive loads (like power supplies). Depending upon the loads the current phasor can be in-phase with voltage, lagging the voltage or leading the voltage. Figure 2: Phasor diagram for purely resistive load For purely resistive load current is in phase with the voltage. Therefore, phase difference ø=0. Thus giving power factor, cosø=1. Hence the power factor for purely resistive load is unity. Figure 3: Phasor diagram for purely inductive load. In a purely inductive circuit, the current lags the voltage. Therefore, the phase difference between current and voltage ø=90. Hence power factor is lagging. inductive load includes transformers, induction choke, and induction generators, high intensity discharge lighting. These inductive loads constitute your distribution system. This increase in reactive power results in large angle between KW and KVA. This large angle decreases the power factor. The efficiency of inductive equipment and system power factor will vary depending on its manufacturer, design, size and age. Most inductive equipment has a nameplate with operating data, including its power factor at rated load. 1.4 Power factor correction Capacitive power factor correction is applied to circuits which include induction choke as a means of reducing the inductive component of the current and thereby reduce the losses in the supply. There should be no effect on the operation of the choke itself. An induction choke draws current from the supply that is made up of resistive components and inductive components. The current due to the leakage reactance is dependent on the total current drawn by the choke, but the magnetizing current is independent of the load on the choke. The magnetizing current will typically be between 20% and 60% of the rated full load current of the choke. The magnetizing current is the current that establishes the flux in the iron and is very necessary if the choke is going to operate. The magnetizing current does not actually contribute to the actual work output of the choke. It is a catalyst that allows the choke to work properly. The magnetizing current and the leakage reactance can be considered as the passenger components of current that will not affect that the power drawn by the choke, but contribute to the power dissipated in the supply and distribution system. 1.5 Disadvantages of Low Power Factor i) Large Line Losses (Copper Losses): Line Losses is directly proportional to the square of current I2 therefore, larger the current, the greater the line losses. ii) Large kva rating and size of electrical equipment s: Power factor is inversely proportional to the kva i.e. CosФ = kw / kva Therefore, lower the power factor, the larger the kva rating of machines also, the larger the kva rating of machines, the larger the size of machines, the larger the cost of machines. In a purely capacitive circuit, the current leads the voltage therefore the phase difference between current and voltage ø=90.thus the power factor is said to be leading. 1.3 Causes of Low Power Factor Low Power factor is caused by inductive loads. Inductive loads require the current to create a magnetic field that produces the desired work. The result is an increase in reactive and apparent power and a decrease in the power factor, or efficiency, of a system. Since the power factor is defined as the ratio of KW to KVA, we see that low power factor results when KW is small in relation to KVA. An iii) Greater conductor size and cost: In case of low power factor, current will be increased, thus to transmit this high current, we need the larger size of conductor. Also, the cost of large size of conductor will be increased. iv) Poor voltage regulation and large voltage drop: Voltage drop = V = IZ. With low power factor, current will be increased. So the larger the current, the larger the voltage drop. In case of low power factor there would be large voltage drop which cause low voltage regulation. 2018, IRJET Impact Factor value: 6.171 ISO 9001:2008 Certified Journal Page 3758

v) Low efficiency: In case of low power factor, there would be large voltage drop and large line losses and this will cause the system or equipment efficiency too low. Due to low power factor, there would be large line losses; therefore, alternator needs high excitation, thus, generation efficiency would be low. these capacitors reduce the lagging nature of the load by giving leading currents to it. The number of capacitors switching depends on the value of the power factor very low power factor needs all the capacitor, whereas high power factor needs none of those. 2.1 Hardware vi) Penalty from electric power supply Electrical power Supply Company imposes a penalty of power factor below 0.95 lagging in electric power bill. So industries must improve power factor above 0.95. 2) PROPOSED SYSTEM Arduino is used in this project as a central processing unit to calculate the power factor and to switch the capacitors. The working of this project is explained with the help of the below block diagram. Fig 2.2 The proposed work can be explained in the form of block diagram as shown in figure 2.2 It comprises of following 7 blocks CT & PT Comparator unit Fig 2.1 It uses a potential transformer to supply the voltage to the Resistor divider network (like zero voltage crossing circuit), which detects the zero crossing of the voltage wave form. These voltage pulses from the operational amplifier are applied to the Arduino as interrupt signals. Similarly, a current transformer is used here to give the current wave to the Resistor divider network wherein the operational amplifier output is enabled for every 10 ms by comparing the zero position of the current with the predefined setting. This signal is also applied to the Arduino as an interrupt signal. The Arduino finds time elapse between these two interrupts and substitutes it in a certain equation for calculating the power factor. If this power factor value is above 0.96 then the Arduino doesn t send any command signals to the relay driver to switch the capacitors on. But, if it is less than 0.96, then the Arduino sends command signals to the relay driver so that the capacitor bank on. Therefore, Resistor divider network Arduino LCD Relay Capacitor bank 2.1.1 Voltage & current measurement unit Current transformer (CT) is connected series with line, and Potential transformer (PT) is connected parallel with supply line. CT & PT are used to step down the voltage and current for resistor divider network. 2.1.2 Comparator unit It compares the value of voltage and current from CT and PT and gives this value to Arduino. 2018, IRJET Impact Factor value: 6.171 ISO 9001:2008 Certified Journal Page 3759

2.1.3 Resistor divider network Resistor voltage dividers are commonly used to create reference voltages, or to reduce the magnitude of a voltage so it can be measured. A simple example of a voltage divider is two resistors connected in series, with the input voltage applied across the resistor pair and the output voltage emerging from the connection between them. 2.1.4 LCD An Arduino program must interact with the outside world using input and output devices that Communicate directly with a human being. One of the most common devices attached to an Arduino is a Liquid crystal display. Some of the most common LCDs connected to the Arduino are 16x2 and 20x2 displays. 2.1.5 Relay Relay outputs are provided which operate to connect or disconnect the capacitor banks depending upon of the power factor conditions. 2.1.6 Capacitor bank Capacitor bank is an assembly of number of capacitors which are used to contribute KVAr in the electrical system and finally improve the power factor. Shunt capacitors bank are arrangements of series/paralleled connected units. 2.1.7 SOFTWARE REQUIREMENT Arduino sketch software 2.2 RESULTS Inductive Load 3 CONCLUSIONS Fig.2.4: After P.F.C. It can be concluded that power factor correction technique can be applied to the industries, power systems and also house hold to make them stable and due to that the system becomes stable and efficiency of the systems as well as the The authors can acknowledge any person/authorities in this section. This is not mandatory. apparatus increases. When the detected power absorbed by the load is greater than the compensator rating, the power factor will not be corrected to unity but certainly, will be improved and the apparent power supplied by the AC supply will be reduced. They achieve better power quality by reducing the apparent power drawn from the AC supply and minimizing the power transmission losses. Hence the efficiency of the systems as well as the apparatus increases. REFERENCES [1] Sapna Khanchi & Vijay Kumar Garg, Power Factor Improvement of Induction Motor by using Capacitors, International Journal of Engineering Trends & Technology (IJETT), Volume 4, issued 7- July 2013. [2] Jain Sandesh, Thakur Shivendra Singh and Phulambrikar S.P., Improve Power Factor and Reduce the Harmonic Distortion of the System, International Journal of Advanced Research in Computer Science and Software Engineeriong. Volume 1(5), issued November 2012. Fig.2.3: Before PFC [3] JBV Subrahmanyam, S.Radha Krishna Reddy, P.K. Sahoo, N.Madhukar Reddy, C.Sashidhar, A Novel Method for Improvement of Power Factor in Wind Mill Power station International Journal of 2018, IRJET Impact Factor value: 6.171 ISO 9001:2008 Certified Journal Page 3760

Engineering Technology and Advanced Engineering, Volume 2, issue 2 February 2012. [4] Abhinav Sharma, Shavet Sharma, Parveen Lehana & Saleem Khan, To Analysis the Effect of Combination Load on the Power Factor, International Journal of Advanced Research in Computer Science and Software Engineering, volume 3, issue 8, August 2013. [5] Anant Kumar Tiwari, Automatic Power Factor Correction Using Capacitive Bank, International Journal of Engineering Research and Applications, Volume 4, issued February 2014. BIOGRAPHIES Bhargav Jayswal, I am a final year student of Electrical. Dept.in Vadodara institute of engineering, Vadodara. Vivek Khushwaha, I am a final year student of Electrical. Dept.in Vadodara institute of engineering, Vadodara Prof.Pushpa Bhatiya I am Assistant Professor in the Department of Electrical Engineering, in Vadodara institute of engineering, Vadodara 2018, IRJET Impact Factor value: 6.171 ISO 9001:2008 Certified Journal Page 3761