Supplemental Information

Similar documents
Supporting Information

TCSPC at Wavelengths from 900 nm to 1700 nm

PCS-150 / PCI-200 High Speed Boxcar Modules

IR Antibunching Measurements with id201 InGaAs Gated SPAD Detectors

Instrument response function. Left linear scale, right logarithmic scale. FWHM is 120 ps.

Time-Correlated Single Photon Counting

High collection efficiency MCPs for photon counting detectors

Optical Receivers Theory and Operation

Supporting Information for: Getting to the (Square) Root of the Problem: How to Make Non-Coherent Pumped Upconversion Linear

Spectroscopy of Ruby Fluorescence Physics Advanced Physics Lab - Summer 2018 Don Heiman, Northeastern University, 1/12/2018

Design Coordination of Pre-amp EDFAs and PIN Photon Detectors For Use in Telecommunications Optical Receivers

Fast Raman Spectral Imaging Using Chirped Femtosecond Lasers

Elimination of Self-Pulsations in Dual-Clad, Ytterbium-Doped Fiber Lasers

Measuring Kinetics of Luminescence with TDS 744 oscilloscope

Fluorescence Lifetime Measurements of BODIPY and Alexa Dyes on ChronosFD and K2

Simple setup for nano-second time-resolved spectroscopic measurements by a digital storage oscilloscope

Photon Counters SR430 5 ns multichannel scaler/averager

Lecture 18: Photodetectors

TCSPC measurements with the InGaAs/InP Single- photon counter

COMPONENTS OF OPTICAL INSTRUMENTS. Chapter 7 UV, Visible and IR Instruments

COMPONENTS OF OPTICAL INSTRUMENTS. Topics

Chemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES

An 8-Channel Parallel Multispectral TCSPC FLIM System

2018 Conference on Laboratory Instruction Beyond the First Year. Quick Summary

Instruction manual and data sheet ipca h

SUPPLEMENTARY INFORMATION

DCS-120. Confocal Scanning FLIM Systems. Based on bh s Multidimensional Megapixel FLIM Technology

Single-photon excitation of morphology dependent resonance

Solea. Supercontinuum Laser. Applications

SUPPLEMENTARY INFORMATION

Lecture 21. Wind Lidar (3) Direct Detection Doppler Lidar

Wide-Field TCSPC FLIM with bh SPC-150 N TCSPC System and Photek FGN Detector

High Average Power, High Repetition Rate Side-Pumped Nd:YVO 4 Slab Laser

Supplementary Information for

Silicon Avalanche Photodiode SAR-/SARP-Series

Characterisation of SiPM Index :

Non-Descanned FLIM Detection in Multiphoton Microscopes

PMT tests at UMD. Vlasios Vasileiou Version st May 2006

arxiv:hep-ex/ v1 19 Apr 2002

Direct Measurement of Optical Cross-talk in Silicon Photomultipliers Using Light Emission Microscopy

ECE 340 Lecture 29 : LEDs and Lasers Class Outline:

Silicon Photomultiplier

Nd:YSO resonator array Transmission spectrum (a. u.) Supplementary Figure 1. An array of nano-beam resonators fabricated in Nd:YSO.

Key Questions. What is an LED and how does it work? How does a laser work? How does a semiconductor laser work? ECE 340 Lecture 29 : LEDs and Lasers

Experiment 2B Integrated Laboratory Experiment DETERMINATION OF RIBOFLAVIN: A COMPARISON OF TECHNIQUES PART B. MOLECULAR FLUORESCENCE SPECTROSCOPY

David Jameson 4/4/2018

Detectors for microscopy - CCDs, APDs and PMTs. Antonia Göhler. Nov 2014

Cavity QED with quantum dots in semiconductor microcavities

Graphene electro-optic modulator with 30 GHz bandwidth

Basic Instrumentation

The DCS-120 Confocal Scanning FLIM System

You won t be able to measure the incident power precisely. The readout of the power would be lower than the real incident power.

SUPPLEMENTARY INFORMATION

Supplementary Figures

Luminous Equivalent of Radiation

Principles of Fluorescence Techniques 2014 Urbana-Champaign, Illinois April 7-10, 2014

Multi-wavelength TCSPC lifetime imaging Wolfgang Becker a, Axel Bergmann a, Christoph Biskup b, Thomas Zimmer b, Nikolaj Klöcker c, Klaus Benndorf b

David Jameson 3/23/2015

Optical Receiver Operation With High Internal Gain of GaP and GaAsP/GaP Light-emitting diodes

Photodiode: LECTURE-5

LABORATÓRIUMI GYAKORLAT SILLABUSZ SYLLABUS OF A PRACTICAL DEMONSTRATION. financed by the program

Supplementary Information:

DETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response

Application Notes Photoconductive Cells

The Weber Conference on Advanced Fluorescence Microscopy Techniques December 12-17, 2011 Buenos Aires

Advancement in development of photomultipliers dedicated to new scintillators studies.

Study of monitoring system of a calibration laser for the itop detector at Belle II

Low threshold continuous wave Raman silicon laser

LASER Transmitters 1 OBJECTIVE 2 PRE-LAB

PERFORMANCE OF THE CMS ECAL LASER MONITORING SOURCE IN THE TEST BEAM

PET Detectors. William W. Moses Lawrence Berkeley National Laboratory March 26, 2002

SINPHOS SINGLE PHOTON SPECTROMETER FOR BIOMEDICAL APPLICATION

DCS-120. Confocal Scanning FLIM Systems. Based on bh s Multidimensional Megapixel FLIM Technology

Solid State Photomultiplier: Noise Parameters of Photodetectors with Internal Discrete Amplification

Synchronization in Chaotic Vertical-Cavity Surface-Emitting Semiconductor Lasers

Lecture 9 External Modulators and Detectors

Direct Measurement of Optical Cross-talk in Silicon Photomultipliers Using Light Emission Microscopy

Examination Optoelectronic Communication Technology. April 11, Name: Student ID number: OCT1 1: OCT 2: OCT 3: OCT 4: Total: Grade:

Highly Sensitive Filter-Less Fluorescence Detection Method Using an Avalanche Photodiode

Abstract No. 32. Arne Bengtson and Tania Irebo. Swerea KIMAB AB, Isafjordsgatan 28A, SE Kista, Sweden

Understanding the Magnetic Resonance Spectrum of Nitrogen Vacancy Centers in an Ensemble of Randomly-Oriented Nanodiamonds, Supporting Information

Chapter 3 OPTICAL SOURCES AND DETECTORS

High resolution cavity-enhanced absorption spectroscopy with a mode comb.

Administrative details:

DEVELOPMENT OF CW AND Q-SWITCHED DIODE PUMPED ND: YVO 4 LASER

SHM-180 Eight Channel Sample & Hold Module

Characterizing a single photon detector

Boston Electronics Corporation 91 Boylston Street, Brookline MA USA (800) or (617) fax (617)

University of Pennsylvania Center for Sensor Technologies Philadelphia, PA SUNFEST REU Program

Picosecond Time Analyzer Applications in...

A Narrow-Band Tunable Diode Laser System with Grating Feedback

PERFORMANCE OF PHOTODIGM S DBR SEMICONDUCTOR LASERS FOR PICOSECOND AND NANOSECOND PULSING APPLICATIONS

Design and Simulation of N-Substrate Reverse Type Ingaasp/Inp Avalanche Photodiode

INSTRUMENTATION BREADBOARDING (VERSION 1.3)

FIBER OPTICS. Prof. R.K. Shevgaonkar. Department of Electrical Engineering. Indian Institute of Technology, Bombay. Lecture: 18.

Laser Induced Ignition with Resonant Multiphoton Absorption in Oxygen

Fiber-Optic Communication Systems

Vertical External Cavity Surface Emitting Laser

InP-based Waveguide Photodetector with Integrated Photon Multiplication

Redefining Measurement ID101 OEM Visible Photon Counter

Transcription:

Optically Activated Delayed Fluorescence Blake C. Fleischer, Jeffrey T. Petty, Jung-Cheng Hsiang, Robert M. Dickson, * School of Chemistry & Biochemistry and Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, GA 30332-0400 and Department of Chemistry, Furman University, Greenville, SC Supplemental Information *Email: dickson@chemistry.gatech.edu Fluorescence spectra and lifetimes Fluorescence excitation and emission spectra were recorded on a fluorescence spectrophotometer Figure S1. Fluorescence excitation and emission spectra for 630 nm emitters. (Photon Technology International QM-4/2006), and are shown in Figure S1. The excitation peak matches the previously published absorption spectrum of this emitter, with a maximum near 560nm. 1 Fluorescence lifetimes under 560nm pulsed LED excitation were recorded on an Edinburgh Instruments Lifespec with an MCP PMT as a detector (Figure S2). A single 2.2ns lifetime is extracted from a reconvolution fit with the measured instrument response function. The IRF, lifetime data, and reconvolution fit are all plotted in Figure S2.

Figure S2. Time-correlated single photon counting-collected fluorescence lifetime of 630nm emitting Ag nanocluster in aqueous solution. Pulsed 560nm LED excitation at 5 MHz was used to excite emission. Emission was collected through a 20nm bandwidth filter centered at 630nm. Photon arrival times relative to the laser trigger are plotted in red. The instrument response function is the black curve (right y-axis), and the reconvolution fit is overplotted as the blue line on top of the red fluorescence data. A single exponential lifetime of 2.2ns is obtained from the fit.

Figure S3. Semi-log plot of Figure 1.

Figure S4. Excitation and emission spectra of SR101 used as background for data presented in Figure 6 of the manuscript. Excitation was at 560nm, collecting emission through a 590nm long pass and 694nm short pass filter. The quantum yield of SR101 is 0.9 and the peak extinction coefficient is 139,000 M -1 cm -1. 2

Mathematica Simulation Optimization Simulations were performed using initial photophysical parameters and experimental conditions derived from continuous wave enhancement studies. 1 Excitation using pulsed 532 nm primary excitation and either continuous wave (CW) or pulsed 803 nm secondary excitation were incorporated into the simulation. The rate matrix in equation 1 (main text) was exponentiated using either the pulsed-cw or pulsed-pulsed excitation conditions as indicated in the text. In each case, a fully populated ground state was used as the initial condition. Simulations were run varying both Φ "#$%& ' & and Φ "#$%( ' & (keeping them the equal to each other) while holding the σ %& and σ %( constant and different by a factor of 4 to reflect the 4-fold different measured slopes ( σ %& Φ "#$%& ' & and σ %( Φ "#$%( ' & ). S1 populations were used as surrogates of fluorescence, and decays outside the initial fluorescent lifetime were fit with biexponential decays. For each secondary-cw simulation, many different secondary powers were used with a given set of photophysical parameters, and fits of dark state decay vs secondary excitation intensity were compared to experimental values. Pulsed-pulsed excitations were also simulated using 1 ns pulse widths (the simulation time step) and 45 ns delays between primary and secondary pulses. For a given set of conditions, the ratio of primary- to secondary-induced fluorescence was compared to the dark state populations from the pulsed-cw secondary excitation intensity decays. Results from both were scaled proportionally to match experiment. Background Free Fluorescence Concentration Recovery Nanomolar solutions of Ag clusters and Sulforhodamine 101 (S101) dye were used to demonstrate concentration recovery using optically activated delayed fluorescence (OADF). A 10 MHz pulsed 560 nm diode laser (680 W/cm 2 ) was used for primary excitation and a CW 803-nm fiber-coupled diode laser (190 kw/cm 2 ) was used as secondary illumination. Emission was collected with an avalanche photodiode and time correlated single photon counting was performed with a Becker- Hickl SPC-630 card. Matlab (Mathworks, r2015a) was used to analyze the collected single photon counting data files and filter photons arriving in specific time windows after the primary pulse, allowing for time-gating to be executed in the analysis. (1) Hsiang, J. C.; Fleischer, B. C.; Dickson, R. M., Dark State-Modulated Fluorescence Correlation Spectroscopy for Quantitative Signal Recovery. J. Phys. Chem. Lett. 2016, 7, 2496-2501. (2) Birge, R. R., Kodak Laser Dyes. In Kodak Publication JJ-169, Eastman Kodak Company: Rochester, NY, 1987.